5
-
-
0005275605
-
Non-linear multiscale processing in digital chest radiography: Results of a patient study with simulated chest lesions
-
abstract 1319
-
(2000)
Europ Radiol
, vol.10
, Issue.SUPPL. 2
-
-
Dencker, E.1
Stahl, M.2
Dippels3
-
8
-
-
0032738191
-
Computed radiography versus screen-film radiography: Detection of pulmonary edema in a rabbit model that simulates neonatal pulmonary infiltrates
-
(1999)
Radiology
, vol.213
, pp. 455-460
-
-
Don, S.1
Hildebolt, C.2
Sharp, T.3
-
11
-
-
0032812524
-
Experimental comparison of noise and resolution for 2 K and 4 K storage phosphor radiography systems
-
(1999)
Med Phys
, vol.26
, pp. 1612-1623
-
-
Flynn, M.J.1
Samei, E.2
-
13
-
-
0026609825
-
Erkennbarkeit zentralvenöser katheter bei einsatz der digitalen lumineszenzradiographie in der intensivmedizinischen radiologie
-
(1992)
RÖFO
, vol.156
, pp. 68-72
-
-
Galanski, M.1
Prokop, M.2
Thorns, E.3
-
14
-
-
0033985984
-
Digital radiography versus conventional radiography in chest imaging: Diagnostic performance of a large area silicon flat panel detector in a clinical CT controlled study
-
(2000)
AJR
, vol.174
, pp. 75-80
-
-
Garmer, M.1
Hennigs, S.P.2
Jager, H.J.3
-
15
-
-
0033801477
-
Digital chest radiography with a selenium based flat panel detector versus a storage phosphor system: Comparison of soft copy images
-
(2000)
AJR
, vol.175
, pp. 1013-1018
-
-
Goo, J.M.1
Im, J.G.2
Kim, J.H.3
-
16
-
-
0002800914
-
Digitale radiographie mit einem elektronischen flachdetektor: Erste klinische erfahrungen in der skelettdiagnostik
-
(1999)
Kontrast
, vol.13
, pp. 2-13
-
-
Hamers, S.1
Freyschmidt, J.2
-
17
-
-
0011671287
-
Dosiseinsparung beim thoraxbild: Vergleich von aufnahmen mit empfindlichkeitsklassen 400 und 640 an einem volldigitalen thoraxarbeitsplatz mit flachbilddetektor
-
abstract VO 283
-
(2000)
RÖFO
, vol.172
, Issue.S
-
-
Hausmann, J.1
Aretz, K.2
Kampschulte, A.3
-
21
-
-
0029242713
-
Interpretation of subtle interstitial chest abnormalities: Conventional radiography versus high resolution storage phosphor radiography, a preliminary study
-
(1995)
J Digit Imaging
, vol.8
, Issue.SUPPL. 1
, pp. 31-36
-
-
Ikezoe, J.1
Kohno, N.2
Kido, S.3
-
31
-
-
0002436029
-
Systeme für die digitale Röntgenbildgebung
-
Ewen K (Hrsg). Referenzreihe Radiologische Diagnostik, Hrsg. U. Mödder. Thieme, Stuttgart
-
(1998)
Moderne Bildgebung
-
-
Neitzel, U.1
-
32
-
-
0026689155
-
Grids or air gaps for scatter reduction in digital radiography: A model calculation
-
(1992)
Med Phys
, vol.19
, pp. 475-481
-
-
Neitzel, U.1
-
33
-
-
0031961309
-
Subtile pulmonary abnormalities: Detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies
-
(1998)
Radiology
, vol.207
, pp. 237-242
-
-
Otto, D.1
Bernhardt, T.M.2
Rapp-Bernhardt, U.3
-
37
-
-
0002164792
-
Erkennbarkeit simulierter Lungenerkrankungen mit dem Silizium-Festkörperdetektor unter Berücksichtigung der Dosisreduktion im Vergleich zum aysmmetrischen Film-Folien-System
-
abstract VO 287
-
(2000)
RÖFO
, vol.172
, Issue.SUPPL.
-
-
Rapp-Bernhardt, U.1
Bernhardt, T.M.2
Krause, U.W.3
-
42
-
-
0031969647
-
Detection of simulated chest lesions with normal and reduced radiation dose: Comparison of conventional screen-film radiography and a flat panel x-ray detector based on amorphous silicon
-
(1998)
Invest Radiol
, vol.33
, pp. 98-103
-
-
Strotzer, M.1
Gmeinwieser, J.K.2
Volk, M.3
-
45
-
-
0030901667
-
Chest radiography: Depiction of normal anatomy and pathologic structures with selenium based digital radiography versus conventional screen-film radiography
-
(1997)
Radiology
, vol.203
, pp. 197-201
-
-
Woodard, P.K.1
Slone, R.M.2
Gierada, D.S.3
-
46
-
-
0031453264
-
Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a prototype real time detector
-
(1997)
Med Phys
, vol.24
, pp. 1834-1843
-
-
Zhao, W.1
Blevis, I.2
German, S.3
|