메뉴 건너뛰기




Volumn 201, Issue 1, 1996, Pages 45-50

Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions

Author keywords

Phantoms; Radiography, digital; Radiography, technology; Receiver operating characteristic curve (ROC); Thorax, radiography

Indexed keywords

ARTICLE; CONTRAST ENHANCEMENT; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; IMAGE ANALYSIS; IMAGE QUALITY; PHANTOM; PRIORITY JOURNAL;

EID: 0029790337     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.201.1.8816519     Document Type: Article
Times cited : (61)

References (18)
  • 1
    • 0027396187 scopus 로고
    • Portable chest imaging: Comparison of storage phosphor digital, asmmetric screen-film, and conventional screen-film systems
    • Niklason LT, Chan HP, Cascade PN, Chang CL, Chees PW, Mathews JF. Portable chest imaging: comparison of storage phosphor digital, asmmetric screen-film, and conventional screen-film systems. Radiology 1993; 186:387-393.
    • (1993) Radiology , vol.186 , pp. 387-393
    • Niklason, L.T.1    Chan, H.P.2    Cascade, P.N.3    Chang, C.L.4    Chees, P.W.5    Mathews, J.F.6
  • 2
    • 0026606935 scopus 로고
    • Threshold perception performance with computed and screen-film radiography: Implications for chest-radiography
    • Dobbins JT III, Rice JJ, Beam CA, Ravin CE. Threshold perception performance with computed and screen-film radiography: implications for chest-radiography. Radiology 1992; 183:179-187.
    • (1992) Radiology , vol.183 , pp. 179-187
    • Dobbins III, J.T.1    Rice, J.J.2    Beam, C.A.3    Ravin, C.E.4
  • 3
    • 0028957128 scopus 로고
    • Technical evaluation of a digital chest radiography system that uses a selenium detector
    • Chotas HG, Floyd CE, Ravin CE. Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology 1995; 195:264-270.
    • (1995) Radiology , vol.195 , pp. 264-270
    • Chotas, H.G.1    Floyd, C.E.2    Ravin, C.E.3
  • 4
    • 0028227069 scopus 로고
    • Image quality of a digital chest radiography system based on a selenium detector
    • Neitzel U, Maack I, Günther-Kohfahl S. Image quality of a digital chest radiography system based on a selenium detector. Med Phys 1994; 21:509-516.
    • (1994) Med Phys , vol.21 , pp. 509-516
    • Neitzel, U.1    Maack, I.2    Günther-Kohfahl, S.3
  • 5
    • 0026752629 scopus 로고
    • Impact of hard-copy size on observer performance in digital chest radiography
    • Schaefer CM, Prokop M, Oestmann JW, et al. Impact of hard-copy size on observer performance in digital chest radiography. Radiology 1992; 184:77-81.
    • (1992) Radiology , vol.184 , pp. 77-81
    • Schaefer, C.M.1    Prokop, M.2    Oestmann, J.W.3
  • 6
    • 0027231117 scopus 로고
    • Improved parameters for unsharp mask filtering of digital chest radiographs
    • Prokop M, Schaefer CM, Oestmann JW, Galanski M. Improved parameters for unsharp mask filtering of digital chest radiographs. Radiology 1993; 187:521-526.
    • (1993) Radiology , vol.187 , pp. 521-526
    • Prokop, M.1    Schaefer, C.M.2    Oestmann, J.W.3    Galanski, M.4
  • 7
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz C. Basic principles of ROC analysis. Semin Nucl Med 1987; 8:283-298.
    • (1987) Semin Nucl Med , vol.8 , pp. 283-298
    • Metz, C.1
  • 9
    • 38649132833 scopus 로고
    • Maximum likelihood estimation of parameters of signal detection theory and determination of confidence intervals: Rating-method data
    • Dorfman DD, Alf E. Maximum likelihood estimation of parameters of signal detection theory and determination of confidence intervals: rating-method data. J Math Psychol 1969; 6:487-486.
    • (1969) J Math Psychol , vol.6 , pp. 487-1486
    • Dorfman, D.D.1    Alf, E.2
  • 10
    • 0026664983 scopus 로고
    • Receiver operating characteristic rating analysis: Generalization to the population of readers and patients with the jackknife method
    • Dorfman DD, Berbaum KS, Metz CE. Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method. Invest Radiol 1992; 27:723-731.
    • (1992) Invest Radiol , vol.27 , pp. 723-731
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 11
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • Que W, Rowlands JA. X-ray imaging using amorphous selenium: inherent spatial resolution. Med Phys 1995; 22:365-374.
    • (1995) Med Phys , vol.22 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 12
    • 0000543598 scopus 로고
    • Digital radiography of the chest: State of the art
    • Souto M, Malagari KS, Tucker D, et al. Digital radiography of the chest: state of the art. Eur Radiol 1994; 4:281-297.
    • (1994) Eur Radiol , vol.4 , pp. 281-297
    • Souto, M.1    Malagari, K.S.2    Tucker, D.3
  • 13
    • 0021998968 scopus 로고
    • Investigation of basic imaging properties in digital radiography. IV. Effect of unsharp masking on the detection of simple patterns
    • Loo LD, Doi K, Metz CE. Investigation of basic imaging properties in digital radiography. IV. Effect of unsharp masking on the detection of simple patterns. Med Phys 1985; 12:209-214.
    • (1985) Med Phys , vol.12 , pp. 209-214
    • Loo, L.D.1    Doi, K.2    Metz, C.E.3
  • 14
    • 0024422658 scopus 로고
    • High-frequency edge enhancement in the detection of fine pulmonary lines: Parity between storage phosphor digital images and conventional chest images
    • Oestmann JW, Greene RE, Rubens JR, et al. High-frequency edge enhancement in the detection of fine pulmonary lines: parity between storage phosphor digital images and conventional chest images. Invest Radiol 1989; 24:643-646.
    • (1989) Invest Radiol , vol.24 , pp. 643-646
    • Oestmann, J.W.1    Greene, R.E.2    Rubens, J.R.3
  • 15
    • 0027398152 scopus 로고
    • A new asymmetric screen-film combination for conventional chest radiography: Evaluation in 50 patients
    • Swensen SJ, Gray JE, Brown LR, et al. A new asymmetric screen-film combination for conventional chest radiography: evaluation in 50 patients. AJR 1993; 160:483-486.
    • (1993) AJR , vol.160 , pp. 483-486
    • Swensen, S.J.1    Gray, J.E.2    Brown, L.R.3
  • 16
    • 0025008969 scopus 로고
    • Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease
    • Schaefer CM, Greene R, Oestmann JW, et al. Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease. Radiology 1990; 174:207-210.
    • (1990) Radiology , vol.174 , pp. 207-210
    • Schaefer, C.M.1    Greene, R.2    Oestmann, J.W.3
  • 17
    • 0003994609 scopus 로고
    • Clinical evaluation of a new digital chest imaging system
    • Heesewijk JPM, de Valois JC. Clinical evaluation of a new digital chest imaging system. Eur Radiol 1995; 5:83-87.
    • (1995) Eur Radiol , vol.5 , pp. 83-87
    • Heesewijk, J.P.M.1    De Valois, J.C.2
  • 18
    • 0028738064 scopus 로고
    • Evaluation of a selenium based digital chest radiography system
    • Floyd CE, Chotas HG, Ravin CE. Evaluation of a selenium based digital chest radiography system. SPIE Phys Med Imaging 1994; 2163:110-116.
    • (1994) SPIE Phys Med Imaging , vol.2163 , pp. 110-116
    • Floyd, C.E.1    Chotas, H.G.2    Ravin, C.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.