메뉴 건너뛰기




Volumn 213, Issue 2, 1999, Pages 455-460

Computed radiography versus screen-film radiography: Detection of pulmonary edema in a rabbit model that simulates neonatal pulmonary infiltrates

Author keywords

Computed tomography (CT), comparative studies; Lung, fluid; Radiography, comparative studies; Radiography, in infants and children; Radiography, storage phosphor

Indexed keywords

OLEIC ACID; PHOSPHORUS;

EID: 0032738191     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.213.2.r99nv15455     Document Type: Article
Times cited : (15)

References (18)
  • 1
    • 0024764470 scopus 로고
    • Clinical assessment of phosphor-plate computed radiography: Equipment, strategy, and methods
    • Hillman BJ, Fajardo LL. Clinical assessment of phosphor-plate computed radiography: equipment, strategy, and methods. J Digit Imaging 1989; 2:220-227.
    • (1989) J Digit Imaging , vol.2 , pp. 220-227
    • Hillman, B.J.1    Fajardo, L.L.2
  • 2
    • 0026699292 scopus 로고
    • Comparison of computerized digital and screen-film radiography: Response to variation in imaging kVp
    • Broderick NJ, Long B, Dreesen RG, et al. Comparison of computerized digital and screen-film radiography: response to variation in imaging kVp. Pediatr Radiol 1992; 22:346-349.
    • (1992) Pediatr Radiol , vol.22 , pp. 346-349
    • Broderick, N.J.1    Long, B.2    Dreesen, R.G.3
  • 3
    • 0027502706 scopus 로고
    • Phosphor plate computed radiography: Response to variation in mAs at fixed kVp in an animal model - Potential for neonatal imaging
    • Broderick NJ, Long B, Dreesen RG, et al. Phosphor plate computed radiography: response to variation in mAs at fixed kVp in an animal model - potential for neonatal imaging. Clin Radiol 1993; 47:39-45.
    • (1993) Clin Radiol , vol.47 , pp. 39-45
    • Broderick, N.J.1    Long, B.2    Dreesen, R.G.3
  • 5
    • 0031908617 scopus 로고    scopus 로고
    • Digital radiography in paediatrics: Radiation dose considerations and magnitude of possible dose reduction
    • Hufton AP, Doyle SM, Carty HL. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction. Br J Radiol 1998; 71:186-199.
    • (1998) Br J Radiol , vol.71 , pp. 186-199
    • Hufton, A.P.1    Doyle, S.M.2    Carty, H.L.3
  • 6
    • 0024530652 scopus 로고
    • Use of computed radiography in respiratory distress syndrome in the neonatal nursery
    • Nakano Y, Odagiri K. Use of computed radiography in respiratory distress syndrome in the neonatal nursery. Pediatr Radiol 1989; 19:167-168.
    • (1989) Pediatr Radiol , vol.19 , pp. 167-168
    • Nakano, Y.1    Odagiri, K.2
  • 7
    • 0028746750 scopus 로고
    • Storage phosphor images in the neonatal intensive care unit: A multiobserver preference study
    • Pearce D, Freedman M, Einar VP, et al. Storage phosphor images in the neonatal intensive care unit: a multiobserver preference study. Proc Med Imaging 1994; 2166: 111-118.
    • (1994) Proc Med Imaging , vol.2166 , pp. 111-118
    • Pearce, D.1    Freedman, M.2    Einar, V.P.3
  • 8
    • 0031202739 scopus 로고    scopus 로고
    • Reduction of patient exposure in pediatric radiology
    • Roehrig H, Krupinski EA, Hulett R. Reduction of patient exposure in pediatric radiology. Acad Radiol 1997; 4:547-557.
    • (1997) Acad Radiol , vol.4 , pp. 547-557
    • Roehrig, H.1    Krupinski, E.A.2    Hulett, R.3
  • 9
    • 0028287641 scopus 로고
    • Rabbit pneumothorax: Feasibility of an animal model to simulate neonatal pneumothorax
    • Don S, Cohen MD, Kruger RA, et al. Rabbit pneumothorax: feasibility of an animal model to simulate neonatal pneumothorax. Invest Radiol 1994; 29:558-563.
    • (1994) Invest Radiol , vol.29 , pp. 558-563
    • Don, S.1    Cohen, M.D.2    Kruger, R.A.3
  • 10
    • 0028944972 scopus 로고
    • Volume detection threshold: Quantitative comparison of computed radiography and screen-film radiography in detection of pneumothoraces in an animal model that simulates the neonate
    • Don S, Cohen MD, Kruger RA, et al. Volume detection threshold: quantitative comparison of computed radiography and screen-film radiography in detection of pneumothoraces in an animal model that simulates the neonate. Radiology 1995; 194:727-730.
    • (1995) Radiology , vol.194 , pp. 727-730
    • Don, S.1    Cohen, M.D.2    Kruger, R.A.3
  • 11
    • 0017333137 scopus 로고
    • Embolic pneumopathy induced by oleic acid: A systematic morphologic study
    • Derks CM, Jacobovitz-Derks D. Embolic pneumopathy induced by oleic acid: a systematic morphologic study. Am J Pathol 1977; 87:143-158.
    • (1977) Am J Pathol , vol.87 , pp. 143-158
    • Derks, C.M.1    Jacobovitz-Derks, D.2
  • 16
    • 0020608258 scopus 로고
    • Radiation doses to neonates requiring intensive care
    • Robinson A, Dellagrammaticas HD. Radiation doses to neonates requiring intensive care. Br J Radiol 1983; 56:397-400.
    • (1983) Br J Radiol , vol.56 , pp. 397-400
    • Robinson, A.1    Dellagrammaticas, H.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.