메뉴 건너뛰기




Volumn 44, Issue 11, 1997, Pages 1107-1113

Automated feedback control of body temperature for small animal studies with MR microscopy

Author keywords

Body temperature control; Computer control; Feedback control; Magnetic resonance microscopy; Rodents

Indexed keywords

ALGORITHMS; COMPUTER CONTROL; FEEDBACK CONTROL; IMAGE QUALITY; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; TEMPERATURE CONTROL; THERMISTORS;

EID: 0031281541     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.641338     Document Type: Article
Times cited : (33)

References (17)
  • 1
    • 0001797111 scopus 로고
    • Artifacts in magnetic resonance imaging,"
    • R. M. Henkelman.Artifacts in magnetic resonance imaging," Rev. Magn. Reson. Med., vol. 2, pp. 1-126, 1987.
    • (1987) Rev. Magn. Reson. Med. , vol.2 , pp. 1-126
    • Henkelman, R.M.1
  • 4
    • 0028508850 scopus 로고
    • MR imaging instrumentation and image artifacts,"
    • J. A. Patton.MR imaging instrumentation and image artifacts," Radiographics, vol. 14, pp. 1083-1096, 1994.
    • (1994) Radiographics , vol.14 , pp. 1083-1096
    • Patton, J.A.1
  • 5
    • 0025039543 scopus 로고
    • W. L. Lin, R. B. Roemer, and K. Hynynen, Theoretical and experimental evaluation of a temperature controller for scanned focused ultrasound hyperthermia," Med. Phys., vol. 17, pp. 615-625, 1990.
    • (1990) Med. Phys. , vol.17 , pp. 615-625
    • Lin L, W.1    Roemer, R.B.2    Hynynen, K.3    Theoretical4
  • 6
    • 0026102119 scopus 로고
    • A microprocessor-regulated constant voltage, current, wattage, and temperature electrophoresis power supply,"
    • D. W. Mincey, K. J. Kuzior, L. H. Alien, J. S. Frease, and I. N. Strasser.A microprocessor-regulated constant voltage, current, wattage, and temperature electrophoresis power supply," Anal. Biochem., vol. 193, pp. 168-172, 1991.
    • (1991) Anal. Biochem. , vol.193 , pp. 168-172
    • Mincey, D.W.1    Kuzior, K.J.2    Alien, L.H.3    Frease, J.S.4    Strasser, I.N.5
  • 10
    • 0029996579 scopus 로고    scopus 로고
    • A new in-vivo method for quantitative analysis of stroke lesions using diffusion-weighted magnetic resonance microscopy,"
    • W. L. Hall, H. Benveniste, L. W. Hedlund, and G. A. Johnson.A new in-vivo method for quantitative analysis of stroke lesions using diffusion-weighted magnetic resonance microscopy," Neurolmage, vol. 3, pp. 158-166, 1996.
    • (1996) Neurolmage , vol.3 , pp. 158-166
    • Hall, W.L.1    Benveniste, H.2    Hedlund, L.W.3    Johnson, G.A.4
  • 12
    • 0029030687 scopus 로고
    • MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil,"
    • R. M. Summers, L. W. Hedlund, G. P. Cofer, M. B. Gottsman, J. F. Manibo, and G. A. Johnson.MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil," Magn. Reson. Med., vol. 33, pp. 785-789, 1995.
    • (1995) Magn. Reson. Med. , vol.33 , pp. 785-789
    • Summers, R.M.1    Hedlund, L.W.2    Cofer, G.P.3    Gottsman, M.B.4    Manibo, J.F.5    Johnson, G.A.6
  • 13
    • 0027161930 scopus 로고
    • Diffusionweighted MR microscopy with fast spin-echo,"
    • C. F. Beaulieu, X. Zhou, G. P. Cofer, and G. A. Johnson.Diffusionweighted MR microscopy with fast spin-echo," Magn. Reson. Med., vol. 30, pp. 201-206, 1993.
    • (1993) Magn. Reson. Med. , vol.30 , pp. 201-206
    • Beaulieu, C.F.1    Zhou, X.2    Cofer, G.P.3    Johnson, G.A.4
  • 16
    • 0028283069 scopus 로고
    • Studies on bromobenzene-induced hepatotoxicity using invivo MR microscopy with surgically implanted RF coils,"
    • X. Zhou, R. R. Maronpot, G. P. Gofer, L. W. Hedlund, and G. A. Johnson.Studies on bromobenzene-induced hepatotoxicity using invivo MR microscopy with surgically implanted RF coils," Magn. Reson. Med., vol. 31, pp. 619-627, 1994.
    • (1994) Magn. Reson. Med. , vol.31 , pp. 619-627
    • Zhou, X.1    Maronpot, R.R.2    Gofer, G.P.3    Hedlund, L.W.4    Johnson, G.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.