In vivo dosimetry: Intercomparison between p-type based and n-type based diodes for the 16-25 MV energy range

Author keywords

Diodes; Entrance dose measurements; In vivo dosimetry; Photon beams

Indexed keywords

DOSIMETRY; TEMPERATURE DISTRIBUTION; X RAYS;

EID: 0034047521     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.599013     Document Type: Article
Times cited : (34)

References (24)
  • 1
  • 2
    • 0025166575 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
    • G. Leunens, J. Van Dam, A. Dutreix, and E. van der Schueren, "Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure," Radiother. Oncol. 17, 141-151 (1990).
    • (1990) Radiother. Oncol. , vol.17 , pp. 141-151
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van Der Schueren, E.4
  • 3
    • 0025110912 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose
    • G. Leunens, J. Van Dam, A. Dutreix, and E. van der Schueren, "Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose," Radiother. Oncol. 19, 73-87 (1990).
    • (1990) Radiother. Oncol. , vol.19 , pp. 73-87
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van Der Schueren, E.4
  • 5
    • 0028958815 scopus 로고
    • Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry
    • A. Noel, P. Aletti, P. Bey, and L. Malissard, "Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry," Radiother. Oncol. 34, 144-151 (1995).
    • (1995) Radiother. Oncol. , vol.34 , pp. 144-151
    • Noel, A.1    Aletti, P.2    Bey, P.3    Malissard, L.4
  • 6
    • 0031971860 scopus 로고    scopus 로고
    • The implementation of in vivo dosimetry in a small radiotherapy department
    • M. Voordeckers, H. Goossens, J. Rutten, and W. Van den Bogaert, "The implementation of in vivo dosimetry in a small radiotherapy department," Radiother. Oncol. 47, 45-48 (1998).
    • (1998) Radiother. Oncol. , vol.47 , pp. 45-48
    • Voordeckers, M.1    Goossens, H.2    Rutten, J.3    Van Den Bogaert, W.4
  • 8
    • 0025685514 scopus 로고
    • Correlation between temperature and dose rate dependence of semiconductor response: Influence of accumualted dose
    • Van Dam, G. Leunens, and A. Dutreix, "Correlation between temperature and dose rate dependence of semiconductor response: Influence of accumualted dose," Radiother. Oncol. 19, 345-351 (1990).
    • (1990) Radiother. Oncol. , vol.19 , pp. 345-351
    • Van Dam1    Leunens, G.2    Dutreix, A.3
  • 9
    • 0021043262 scopus 로고
    • Effects of radiation damage on p-type silicon detectors
    • G. Rikner and E. Grusell, "Effects of radiation damage on p-type silicon detectors," Phys. Med. Biol. 28, 1261-1267 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1261-1267
    • Rikner, G.1    Grusell, E.2
  • 10
    • 0022538071 scopus 로고
    • Evaluation of temperature effects in p-type silicon detectors
    • E. Grusell and G. Rikner, "Evaluation of temperature effects in p-type silicon detectors," Phys. Med. Biol. 31, 527-534 (1986).
    • (1986) Phys. Med. Biol. , vol.31 , pp. 527-534
    • Grusell, E.1    Rikner, G.2
  • 11
    • 0027212572 scopus 로고
    • Linearity with dose rate of low resistivity p-type silicon semiconductor detectors
    • E. Grusell and G. Rickner, "Linearity with dose rate of low resistivity p-type silicon semiconductor detectors," Phys. Med. Biol. 38, 785-792 (1993).
    • (1993) Phys. Med. Biol. , vol.38 , pp. 785-792
    • Grusell, E.1    Rickner, G.2
  • 12
    • 84907110099 scopus 로고
    • Radiation damage induced dose rate nonlinearity in a n-type silicon detector
    • E. Grusell and G. Rickner, "Radiation damage induced dose rate nonlinearity in a n-type silicon detector," Acta Radiol.: Oncol. 23, 465-469 (1984).
    • (1984) Acta Radiol.: Oncol. , vol.23 , pp. 465-469
    • Grusell, E.1    Rickner, G.2
  • 13
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • M. Essers and B. J. Mijnheer, "In vivo dosimetry during external photon beam radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 43, 245-249 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , pp. 245-249
    • Essers, M.1    Mijnheer, B.J.2
  • 14
    • 0029376597 scopus 로고
    • A patient dose verification program using diode detectors
    • C. Li, L. S. Lamel, and D. Tom, "A patient dose verification program using diode detectors," Med. Dosim. 20, 209-214 (1995).
    • (1995) Med. Dosim. , vol.20 , pp. 209-214
    • Li, C.1    Lamel, L.S.2    Tom, D.3
  • 15
    • 0030981989 scopus 로고    scopus 로고
    • Characterization of the response of commercial diode detectors used for in vivo dosimetry
    • R. J. Meiler and M. B. Podgorsak, "Characterization of the response of commercial diode detectors used for in vivo dosimetry," Med. Dosim. 22, 31-37 (1997).
    • (1997) Med. Dosim. , vol.22 , pp. 31-37
    • Meiler, R.J.1    Podgorsak, M.B.2
  • 16
    • 0342611201 scopus 로고    scopus 로고
    • Dosimetric evaluation of a plastic water phantom for high energy photon beam use
    • N. Jornet, T. Eudaldo, Ma. D. Carabante, and M. Ribas, "Dosimetric evaluation of a plastic water phantom for high energy photon beam use," Radiother. Oncol. 51, S40 (1999).
    • (1999) Radiother. Oncol. , vol.51
    • Jornet, N.1    Eudaldo, T.2    Carabante, Ma.D.3    Ribas, M.4
  • 17
    • 0029874870 scopus 로고    scopus 로고
    • Calibration of semiconductor detectors for dose assessment in total body irradiation
    • N. Jornet, M. Ribas, and T. Eudaldo, "Calibration of semiconductor detectors for dose assessment in total body irradiation," Radiother. Oncol. 38, 247-251 (1996).
    • (1996) Radiother. Oncol. , vol.38 , pp. 247-251
    • Jornet, N.1    Ribas, M.2    Eudaldo, T.3
  • 18
    • 0030887102 scopus 로고    scopus 로고
    • Dose perturbations due to in vivo dosimetry with diodes
    • R. Alecu, J. J. Feldemeier, and M. Alecu, "Dose perturbations due to in vivo dosimetry with diodes," Radiother. Oncol. 42, 289-291 (1997).
    • (1997) Radiother. Oncol. , vol.42 , pp. 289-291
    • Alecu, R.1    Feldemeier, J.J.2    Alecu, M.3
  • 19
    • 0031909961 scopus 로고    scopus 로고
    • max and diode readings for small field sizes and small SSDs of 15 MV photon beams
    • max and diode readings for small field sizes and small SSDs of 15 MV photon beams," Med. Phys. 25, 245-246 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 245-246
    • Wierzbicki, J.G.1    Waid, D.S.2
  • 20
  • 21
    • 0025960367 scopus 로고
    • Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes
    • S. Heukelom, J. H. Lanson, and B. J. Mijnheer, "Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes," Phys. Med. Biol. 36, 47-59 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 47-59
    • Heukelom, S.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 22
    • 33744637499 scopus 로고
    • In vivo dosimetry during the treatment of parotid gland tumors
    • M. Essers et al., "In vivo dosimetry during the treatment of parotid gland tumors," Radiother. Oncol. 30, 154-162 (1994).
    • (1994) Radiother. Oncol. , vol.30 , pp. 154-162
    • Essers, M.1
  • 24
    • 0030940762 scopus 로고    scopus 로고
    • The effect of dose rate dependence of p-type silicon detectors on linac relative dosimetry
    • D. Wilkins, X. Allen Li, Joanna Cygler, and Lee Gerig, "The effect of dose rate dependence of p-type silicon detectors on linac relative dosimetry," Med. Phys. 24, 879-881 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 879-881
    • Wilkins, D.1    Allen Li, X.2    Cygler, J.3    Gerig, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.