메뉴 건너뛰기




Volumn 198, Issue 2, 2000, Pages 82-87

Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy

Author keywords

Actin; Cytoskeleton; Fluorescence microscopy; Interference; Lateral resolution; Moire microscopy; Optical transfer function; Patterned excitation; Resolution; Structured illumination; Super resolution; Wide field microscopy

Indexed keywords

DIFFRACTION; FLUORESCENCE; OPTICAL TRANSFER FUNCTION; PROTEINS;

EID: 0034028826     PISSN: 00222720     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2818.2000.00710.x     Document Type: Article
Times cited : (3147)

References (17)
  • 1
    • 60049098657 scopus 로고
    • Beiträge zur theorie des mikroskops und der mikroskopischen wahrnehmung
    • Abbe, E. (1873) Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung. Arkiv. Mikroskop. Anat. 9, 413-468.
    • (1873) Arkiv. Mikroskop. Anat. , vol.9 , pp. 413-468
    • Abbe, E.1
  • 3
    • 0013644380 scopus 로고
    • Three-dimensional imaging of biological specimens with standing wave fluorescence microscopy
    • Bailey, B., Krishnamurthi, V., Farkas, D.L., Taylor, D.L. & Lanni, F. (1994) Three-dimensional imaging of biological specimens with standing wave fluorescence microscopy. Proc. SPIE, 2184, 208-213.
    • (1994) Proc. SPIE , vol.2184 , pp. 208-213
    • Bailey, B.1    Krishnamurthi, V.2    Farkas, D.L.3    Taylor, D.L.4    Lanni, F.5
  • 4
    • 0029640071 scopus 로고
    • Super-resolution three-dimensional images of fluorescence in cells with minimal light exposure
    • Carrington, W.A., Lynch, R.M., Moore, E.D.W., Isenberg, G., Fogarty, K.E. & Fay, F.S. (1995) Super-resolution three-dimensional images of fluorescence in cells with minimal light exposure. Science, 268, 1483-1487.
    • (1995) Science , vol.268 , pp. 1483-1487
    • Carrington, W.A.1    Lynch, R.M.2    Moore, E.D.W.3    Isenberg, G.4    Fogarty, K.E.5    Fay, F.S.6
  • 5
    • 84975598368 scopus 로고
    • Confocal fluorescent microscopy with a finite-sized circular detector
    • Gu, M. & Sheppard, C.J.R. (1992) Confocal fluorescent microscopy with a finite-sized circular detector. J. Opt. Soc. Am. A, 9, 151-153.
    • (1992) J. Opt. Soc. Am. A , vol.9 , pp. 151-153
    • Gu, M.1    Sheppard, C.J.R.2
  • 6
    • 0032871413 scopus 로고    scopus 로고
    • Extended resolution fluorescence microscopy
    • Gustafsson, M.G.L. (1999) Extended resolution fluorescence microscopy. Curr. Opin. Struct. Biol. 9, 627-634.
    • (1999) Curr. Opin. Struct. Biol. , vol.9 , pp. 627-634
    • Gustafsson, M.G.L.1
  • 7
    • 0029213489 scopus 로고
    • Sevenfold improvement of axial resolution in 3D widefield microscopy using two objective lenses
    • Gustafsson, M.G.L., Agard, D.A. & Sedat, J.W. (1995) Sevenfold improvement of axial resolution in 3D widefield microscopy using two objective lenses. Proc. SPIE, 2412, 147-156.
    • (1995) Proc. SPIE , vol.2412 , pp. 147-156
    • Gustafsson, M.G.L.1    Agard, D.A.2    Sedat, J.W.3
  • 9
    • 0032864460 scopus 로고    scopus 로고
    • 3D widefield light microscopy with better than 100 nm axial resolution
    • Gustafsson, M.G.L., Agard, D.A. & Sedat, J.W. (1999) 3D widefield light microscopy with better than 100 nm axial resolution. J. Microsc. 195, 10-16.
    • (1999) J. Microsc. , vol.195 , pp. 10-16
    • Gustafsson, M.G.L.1    Agard, D.A.2    Sedat, J.W.3
  • 10
    • 0032639282 scopus 로고    scopus 로고
    • Laterally modulated excitation microscopy: Improvement of resolution by using a diffraction grating
    • Heintzmann, R. & Cremer, C. (1998) Laterally modulated excitation microscopy: improvement of resolution by using a diffraction grating. Proc. SPIE, 3568, 185-195.
    • (1998) Proc. SPIE , vol.3568 , pp. 185-195
    • Heintzmann, R.1    Cremer, C.2
  • 11
    • 0032607671 scopus 로고    scopus 로고
    • Sub-diffraction resolution in far-field fluorescence microscopy
    • Klar, T.A. & Hell, S.W. (1999) Sub-diffraction resolution in far-field fluorescence microscopy. Opt. Lett, 24, 954-956.
    • (1999) Opt. Lett , vol.24 , pp. 954-956
    • Klar, T.A.1    Hell, S.W.2
  • 12
    • 85169172405 scopus 로고
    • US patent 3013467
    • Minsky, M. (1961) US patent 3013467.
    • (1961)
    • Minsky, M.1
  • 13
    • 0000412790 scopus 로고    scopus 로고
    • Method of obtaining optical sectioning by using structured light in a conventional microscope
    • Neil, M.A.A., Juškaitis, R. & Wilson, T. (1997) Method of obtaining optical sectioning by using structured light in a conventional microscope. Opt. Lett. 22, 1905-1907.
    • (1997) Opt. Lett. , vol.22 , pp. 1905-1907
    • Neil, M.A.A.1    Juškaitis, R.2    Wilson, T.3
  • 14
    • 0032119068 scopus 로고    scopus 로고
    • Real time 3D fluorescence microscopy by two beam interference illumination
    • Neil, M.A.A., Juškaitis, R. & Wilson, T. (1998) Real time 3D fluorescence microscopy by two beam interference illumination. Opt. Commun. 153, 1-4.
    • (1998) Opt. Commun. , vol.153 , pp. 1-4
    • Neil, M.A.A.1    Juškaitis, R.2    Wilson, T.3
  • 17
    • 0001463169 scopus 로고
    • The role of the pinhole in confocal imaging system
    • (ed. by J. B. Pawley). Plenum Press, New York
    • Wilson, T. (1995) The role of the pinhole in confocal imaging system. Handbook of Biological Confocal Microscopy (ed. by J. B. Pawley), pp. 167-182. Plenum Press, New York.
    • (1995) Handbook of Biological Confocal Microscopy , pp. 167-182
    • Wilson, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.