메뉴 건너뛰기




Volumn 27, Issue 8, 2000, Pages 1732-1738

Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery

Author keywords

Enhanced dynamic wedge; Gated radiotherapy; IMRT; Linear accelerator

Indexed keywords

LINEAR ACCELERATORS;

EID: 0033849941     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1287110     Document Type: Article
Times cited : (55)

References (21)
  • 2
    • 0033048691 scopus 로고    scopus 로고
    • Clinical and financial issues for intensity-modulated radiation therapy delivery
    • W. Grant III and S. Y. Woo, "Clinical and financial issues for intensity-modulated radiation therapy delivery," Semin. Radiat. Oncol. 9, 99-107 (1999).
    • (1999) Semin. Radiat. Oncol. , vol.9 , pp. 99-107
    • Grant W. III1    Woo, S.Y.2
  • 3
    • 0033013069 scopus 로고    scopus 로고
    • Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems
    • L. J. Verhey, "Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems," Semin. Radiat. Oncol. 9, 78-98 (1999).
    • (1999) Semin. Radiat. Oncol. , vol.9 , pp. 78-98
    • Verhey, L.J.1
  • 5
    • 0032972221 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy with dynamic multileaf collimators
    • A. L. Boyer and C. X. Yu, "Intensity-modulated radiation therapy with dynamic multileaf collimators," Semin. Radiat. Oncol. 9, 48-59 (1999).
    • (1999) Semin. Radiat. Oncol. , vol.9 , pp. 48-59
    • Boyer, A.L.1    Yu, C.X.2
  • 6
    • 0033556637 scopus 로고    scopus 로고
    • A non-invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease
    • J. S. Tsai, M. J. Engler, M. N. Ling, J. K. Wu, B. Kramer, T. Dipetrillo, and D. E. Wazer, "A non-invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease," Int. J. Radiat. Oncol., Biol., Phys. 43, 455-467 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , pp. 455-467
    • Tsai, J.S.1    Engler, M.J.2    Ling, M.N.3    Wu, J.K.4    Kramer, B.5    Dipetrillo, T.6    Wazer, D.E.7
  • 7
    • 0031695241 scopus 로고    scopus 로고
    • Inverse planning with constraints to generate smoothed intensity-modulated beams
    • S. Webb, D. J. Convery, and P. M. Evans, "Inverse planning with constraints to generate smoothed intensity-modulated beams," Phys. Med. Biol. 43, 2785-2794 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2785-2794
    • Webb, S.1    Convery, D.J.2    Evans, P.M.3
  • 8
    • 0031762329 scopus 로고    scopus 로고
    • Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
    • T. LoSasso, C. S. Chui, and C. S. Ling, "Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy," Med. Phys. 25, 1919-1927 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1919-1927
    • LoSasso, T.1    Chui, C.S.2    Ling, C.S.3
  • 9
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique
    • M. Partridge, P. M. Evans, A. Mosleh-Shirazi, and D. Convery, "Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique," Med. Phys. 25, 1872-1879 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1872-1879
    • Partridge, M.1    Evans, P.M.2    Mosleh-Shirazi, A.3    Convery, D.4
  • 10
    • 2642683174 scopus 로고    scopus 로고
    • An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion
    • J. Lof, B. K. Lind, and A. Brahme, "An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion," Phys. Med. Biol. 43, 1605-1628 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1605-1628
    • Lof, J.1    Lind, B.K.2    Brahme, A.3
  • 13
    • 0034006554 scopus 로고    scopus 로고
    • Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center
    • H. D. Kubo, P. M. Len, S. Minohara, and H. Mostafavi, "Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center," Med. Phys. 27, 346-353 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 346-353
    • Kubo, H.D.1    Len, P.M.2    Minohara, S.3    Mostafavi, H.4
  • 14
    • 0032692401 scopus 로고    scopus 로고
    • Potential role of a prototype amorphous silicon array electronic portal imaging device in breathing gated radiation treatment
    • H. D. Kubo, E. G. Shapiro, and E. J. Seppi, "Potential role of a prototype amorphous silicon array electronic portal imaging device in breathing gated radiation treatment," Med. Phys. 26, 2410-2414 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2410-2414
    • Kubo, H.D.1    Shapiro, E.G.2    Seppi, E.J.3
  • 15
    • 33744554563 scopus 로고    scopus 로고
    • Breathing synchronized radiotherapy at the University of California Davis Cancer Center
    • abstract
    • H. Kubo, P. Len, S. Minohara, and H. Mostofavi, "Breathing synchronized radiotherapy at the University of California Davis Cancer Center," Med. Phys. 26, 1106 (1999) (abstract).
    • (1999) Med. Phys. , vol.26 , pp. 1106
    • Kubo, H.1    Len, P.2    Minohara, S.3    Mostofavi, H.4
  • 16
    • 84947921917 scopus 로고    scopus 로고
    • Clinical experience of breathing synchronized radiotherapy at the University of California Davis Cancer Center
    • abstract
    • H. D. Kubo, P. M. Len, L. Wang, B. R. Leigh, and H. Mostofavi, "Clinical experience of breathing synchronized radiotherapy at the University of California Davis Cancer Center," Int. J. Radial. Oncol., Biol., Phys. 45, 204 (1999) (abstract).
    • (1999) Int. J. Radial. Oncol., Biol., Phys. , vol.45 , pp. 204
    • Kubo, H.D.1    Len, P.M.2    Wang, L.3    Leigh, B.R.4    Mostofavi, H.5
  • 17
    • 0033002415 scopus 로고    scopus 로고
    • Dosimetric advantages of enhanced dynamic wedge in small field irradiation for the treatment of macular degeneration
    • T. Edlund, D. D. Leavitt, and F. A. Gibbs, Jr., "Dosimetric advantages of enhanced dynamic wedge in small field irradiation for the treatment of macular degeneration," Med. Dosim. 24, 21-26 (1999).
    • (1999) Med. Dosim. , vol.24 , pp. 21-26
    • Edlund, T.1    Leavitt, D.D.2    Gibbs F.A., Jr.3
  • 18
    • 0032912080 scopus 로고    scopus 로고
    • The 'equivalent wedge' implementation of the Varian Enhanced Dynamic Wedge (EDW) into a treatment planning system
    • S. Papatheodorou, S. Zefkili, and J. C. Rosenwald, "The 'equivalent wedge' implementation of the Varian Enhanced Dynamic Wedge (EDW) into a treatment planning system," Phys. Med. Biol. 44, 509-524 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 509-524
    • Papatheodorou, S.1    Zefkili, S.2    Rosenwald, J.C.3
  • 19
    • 0031816944 scopus 로고    scopus 로고
    • Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields
    • J. P. Gibbons, "Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields," Med. Phys. 25, 1411-1418 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1411-1418
    • Gibbons, J.P.1
  • 21
    • 0031951215 scopus 로고    scopus 로고
    • Characterizing output for the Varian enhanced dynamic wedge field
    • C. Liu, Z. Li, and J. R. Palta, "Characterizing output for the Varian enhanced dynamic wedge field," Med. Phys. 25, 64-70 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 64-70
    • Liu, C.1    Li, Z.2    Palta, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.