메뉴 건너뛰기




Volumn 25, Issue 8, 1998, Pages 1411-1418

Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields

Author keywords

Asymmetric collimators; Dose computation; Dosimetry; Dynamic wedge; Off axis

Indexed keywords

DOSIMETRY;

EID: 0031816944     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598313     Document Type: Article
Times cited : (39)

References (14)
  • 1
    • 0018134649 scopus 로고
    • Wedge shaped dose distributions by computer-controlled collimator motion
    • P. K. Kijewski, L. M. Chin, and B. E. Bjarngard, "Wedge shaped dose distributions by computer-controlled collimator motion," Med. Phys. 5, 426-429 (1978).
    • (1978) Med. Phys. , vol.5 , pp. 426-429
    • Kijewski, P.K.1    Chin, L.M.2    Bjarngard, B.E.3
  • 2
    • 0025177031 scopus 로고
    • Dynamic wedge field techniques through computer-controlled collimator motion
    • D. D. Leavitt, M. Martin, J. H. Moeller, and W. L. Lee, "Dynamic wedge field techniques through computer-controlled collimator motion," Med. Phys. 17, 87-91 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 87-91
    • Leavitt, D.D.1    Martin, M.2    Moeller, J.H.3    Lee, W.L.4
  • 4
    • 0028930359 scopus 로고
    • Beam data measurements for dynamic wedges on Varian 600C (6-MV) and 2100C (6- and 10-MV) linear accelerators
    • A. M. Bidmead, A. J Garton, and P. J. Childs, "Beam data measurements for dynamic wedges on Varian 600C (6-MV) and 2100C (6- and 10-MV) linear accelerators," Phys. Med. Biol. 40, 393-411 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 393-411
    • Bidmead, A.M.1    Garton, A.J.2    Childs, P.J.3
  • 5
    • 0029160598 scopus 로고
    • Radiotherapy treatment planning with dynamic wedges - An algorithm for generating wedge factors and beam data
    • S. J. Thomas and K. R. Foster, "Radiotherapy treatment planning with dynamic wedges - an algorithm for generating wedge factors and beam data," Phys. Med. Biol. 40, 1421-1433 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1421-1433
    • Thomas, S.J.1    Foster, K.R.2
  • 6
    • 0029947690 scopus 로고    scopus 로고
    • Characterizing output for dynamic wedges
    • C Liu, T. C. Zhu, and J. R. Palta, "Characterizing output for dynamic wedges," Med Phys. 23, 1213-1218 (1996).
    • (1996) Med Phys. , vol.23 , pp. 1213-1218
    • Liu, C.1    Zhu, T.C.2    Palta, J.R.3
  • 8
    • 0022363185 scopus 로고
    • Effective wedge angles with a universal wedge
    • P. L. Petti and R. L. Siddon, "Effective wedge angles with a universal wedge," Phys. Med. Biol. 30, 985-991 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 985-991
    • Petti, P.L.1    Siddon, R.L.2
  • 9
    • 0005165613 scopus 로고
    • Calculation of dynamically-wedged isodose distributions from segmented treatment tables and open-field measurements
    • T. J. Waldron, A. L. Boyer, and N. H. Wells, "Calculation of dynamically-wedged isodose distributions from segmented treatment tables and open-field measurements," Med. Phys. 21, 873 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 873
    • Waldron, T.J.1    Boyer, A.L.2    Wells, N.H.3
  • 13
    • 0029840312 scopus 로고    scopus 로고
    • Implementation of the Varian EDW into a commercial RTP system
    • A. W. Beavis, S. J. Weston, and V. J. Whitton, "Implementation of the Varian EDW into a commercial RTP system," Phys. Med. Biol. 41, 1691-1704 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1691-1704
    • Beavis, A.W.1    Weston, S.J.2    Whitton, V.J.3
  • 14
    • 0029126903 scopus 로고
    • Calculation of monitor units for asymmetric photon fields
    • J P. Gibbons and F. M Khan, "Calculation of monitor units for asymmetric photon fields," Med Phys. 22, 1451-1457 (1993).
    • (1993) Med Phys. , vol.22 , pp. 1451-1457
    • Gibbons, J.P.1    Khan, F.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.