메뉴 건너뛰기




Volumn 53, Issue 7, 1997, Pages 2485-2494

Pitfalls in the synthesis and biological evaluation of sialyl-Lewis(x) mimetics as potential selectin antagonists

Author keywords

[No Author keywords available]

Indexed keywords

ENDOTHELIAL LEUKOCYTE ADHESION MOLECULE 1; PADGEM PROTEIN; SIALIC ACID DERIVATIVE;

EID: 0031575593     PISSN: 00404020     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0040-4020(96)01178-7     Document Type: Article
Times cited : (42)

References (48)
  • 3
    • 0029994497 scopus 로고    scopus 로고
    • 2. Selectins in cell adhesion: a) Mousa, S.A., Drugs of the Future 1996, 21, 283-289;
    • (1996) Drugs of the Future , vol.21 , pp. 283-289
    • Mousa, S.A.1
  • 4
    • 0002670839 scopus 로고    scopus 로고
    • Ed.: Horton, M.A., CRC Press, Boca Raton/Fla
    • b) Watson, S.R., Adhes.Recept.Ther.Targets 1996, 61-73, Ed.: Horton, M.A., CRC Press, Boca Raton/Fla.;
    • (1996) Adhes.Recept.Ther.Targets , pp. 61-73
    • Watson, S.R.1
  • 6
    • 0027982876 scopus 로고
    • d) Springer, T.A., Cell 1994, 76, 301-314.
    • (1994) Cell , vol.76 , pp. 301-314
    • Springer, T.A.1
  • 19
    • 85047671408 scopus 로고
    • e) Kaila, N., Yu, H.-A., Xiang, Y., ibid 1995, 36, 5503-5506; Yuen, C.T., Bezouska, K., O'Brien, J., Stoll, M., Lemoine, R., Lubineau, A., Kiso, M., Hasegawa, A., Bockovich, J., Nicolaou, K.C., Feizi, J., J.Biol.Chem. 1994, 269, 1595-1598.
    • (1995) , vol.36 , pp. 5503-5506
    • Kaila, N.1    Yu, H.-A.2    Xiang, Y.3
  • 40
    • 85069097627 scopus 로고    scopus 로고
    • Resins were thoroughly washed with methanol and water before use. The solution of neutralized 12 was then filtered through a one-way syringe membrane (0.2 μM) before chromatography
    • 8. Resins were thoroughly washed with methanol and water before use. The solution of neutralized 12 was then filtered through a one-way syringe membrane (0.2 μM) before chromatography.
  • 41
    • 85069101941 scopus 로고    scopus 로고
    • The discrepancy in biological activity was observed fortuitously after a synthesis batch had been reproduced on a larger scale according to method A. Attempts to exclude trace impurities released from the anion exchange resins by means of techniques to separation according to molecular size (Biogel, Sephadex) may not be fully successful, since the material released from the resins exhibits a rather broad molecular weight distribution, including small polyanionic fragments (gel permeation chromatography)
    • 9. The discrepancy in biological activity was observed fortuitously after a synthesis batch had been reproduced on a larger scale according to method A. Attempts to exclude trace impurities released from the anion exchange resins by means of techniques to separation according to molecular size (Biogel, Sephadex) may not be fully successful, since the material released from the resins exhibits a rather broad molecular weight distribution, including small polyanionic fragments (gel permeation chromatography).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.