메뉴 건너뛰기




Volumn 11, Issue 1, 2015, Pages 114-128

A methodology for prioritizing water mains rehabilitation in Egypt

Author keywords

GIS technology; Multi criteria model; Rehabilitation technology Simos procedure; Water mains deterioration

Indexed keywords


EID: 85142925255     PISSN: 16874048     EISSN: 20909934     Source Type: Journal    
DOI: 10.1016/j.hbrcj.2014.03.002     Document Type: Article
Times cited : (24)

References (22)
  • 1
    • 85142922144 scopus 로고    scopus 로고
    • Best Practices, The National Guide to Sustainable Municipal Infrastructure, Ottawa, Canada
    • Best Practices. Deterioration and inspection of water distribution systems. The National Guide to Sustainable Municipal Infrastructure, Ottawa, Canada, 2003, 1(1).
    • (2003) Deterioration and inspection of water distribution systems , vol.1 , Issue.1
  • 2
    • 0018318075 scopus 로고
    • An analytic approach to scheduling pipe replacement
    • U.ShamirC.D.D.HowardAn analytic approach to scheduling pipe replacementJ. Am. Water Works Assoc.7151979248258
    • (1979) J. Am. Water Works Assoc. , vol.71 , Issue.5 , pp. 248-258
    • Shamir, U.1    Howard, C.D.D.2
  • 6
    • 57249106515 scopus 로고    scopus 로고
    • A methodology to estimate remaining service life of grey iron water mains
    • B.RajaniJ.MakarA methodology to estimate remaining service life of grey iron water mainsNation. Res. Council Canada200012591272
    • (2000) Nation. Res. Council Canada , pp. 1259-1272
    • Rajani, B.1    Makar, J.2
  • 7
    • 33646167815 scopus 로고    scopus 로고
    • Condition rating model for underground infrastructure sustainable water mains
    • H.Al-BarqawiT.ZayedCondition rating model for underground infrastructure sustainable water mainsJ. Perform. Constr. Facilit.2022006126135
    • (2006) J. Perform. Constr. Facilit. , vol.20 , Issue.2 , pp. 126-135
    • Al-Barqawi, H.1    Zayed, T.2
  • 8
  • 9
    • 0035170558 scopus 로고    scopus 로고
    • Comprehensive review of structural deterioration of water mains: physically based model
    • B.RajaniY.KlienerComprehensive review of structural deterioration of water mains: physically based modelUrb. Water332001151164
    • (2001) Urb. Water , vol.3 , Issue.3 , pp. 151-164
    • Rajani, B.1    Kliener, Y.2
  • 10
    • 79251493560 scopus 로고    scopus 로고
    • Selection of technologies for the rehabilitation or replacement of sections of a water distribution system
    • Ottawa, Canada
    • Best Practices. Selection of technologies for the rehabilitation or replacement of sections of a water distribution system. The National Guide to Sustainable Municipal Infrastructure, Ottawa, Canada, 2003, 1.
    • (2003) . the National Guide to Sustainable Municipal Infrastructure , vol.1
  • 11
  • 12
    • 84962017451 scopus 로고    scopus 로고
    • Factors influencing sub-contractors selection in construction projects
    • M.MarzoukA.A.KherbawyM.KhalifaFactors influencing sub-contractors selection in construction projectsHBRC J.922013150158
    • (2013) HBRC J. , vol.9 , Issue.2 , pp. 150-158
    • Marzouk, M.1    Kherbawy, A.A.2    Khalifa, M.3
  • 13
    • 84872929350 scopus 로고    scopus 로고
    • Feasibility study of industrial projects using Simos’ procedure
    • M.MarzoukO.AmerM.El SaidFeasibility study of industrial projects using Simos’ procedureJ. Civil Eng. Manage.19120135968
    • (2013) J. Civil Eng. Manage. , vol.19 , Issue.1 , pp. 59-68
    • Marzouk, M.1    Amer, O.2    El Said, M.3
  • 15
    • 85142926758 scopus 로고    scopus 로고
    • Prioritizing pipe rehabilitation projects
    • R.MegB.CrystalPrioritizing pipe rehabilitation projectsNC Curr. Summ.20118487
    • (2011) NC Curr. Summ. , pp. 84-87
    • Meg, R.1    Crystal, B.2
  • 17
    • 84884641923 scopus 로고    scopus 로고
    • Modeling fund allocation to water main rehabilitation projects
    • E.MohamedT.ZayedModeling fund allocation to water main rehabilitation projectsJ. Perform. Constr. Facilit.2752013646655
    • (2013) J. Perform. Constr. Facilit. , vol.27 , Issue.5 , pp. 646-655
    • Mohamed, E.1    Zayed, T.2
  • 19
    • 10644239020 scopus 로고    scopus 로고
    • Fuzzy-based method to evaluate soil corrosivity for prediction of water main deterioration
    • R.SadiqB.RajaniY.KleinerFuzzy-based method to evaluate soil corrosivity for prediction of water main deteriorationJ. Infrastruct. Syst.1042004149156
    • (2004) J. Infrastruct. Syst. , vol.10 , Issue.4 , pp. 149-156
    • Sadiq, R.1    Rajani, B.2    Kleiner, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.