1
-
-
84859617261
-
Positron emission tomography
-
Dilsizian and G.M. Pohost, eds., 2nd ed., Blackwell, Hoboken, NJ
-
S.L. Bacharach, “Positron emission tomography,” In: V. Dilsizian and G.M. Pohost, eds., Cardiac CT, PET and MR, 2nd ed., pp. 3-29, Blackwell, Hoboken, NJ, 2010.
-
(2010)
Cardiac CT, PET and MR
, pp. 3-29
-
-
Bacharach, S.L.1
-
2
-
-
84871085103
-
Photo-detectors for time of flight positron emission tomography (ToF-PET)
-
V.C. Spanoudaki and C.S. Levin, “Photo-detectors for time of flight positron emission tomography (ToF-PET),” Sensors (Basel), Vol. 10, pp. 10484-10505, 2010.
-
(2010)
Sensors (Basel)
, vol.10
, pp. 10484-10505
-
-
Spanoudaki, V.C.1
Levin, C.S.2
-
3
-
-
85063306750
-
Does time-of-flight improve image quality in the heart
-
R.G. Wells and R.A. deKemp, “Does time-of-flight improve image quality in the heart,” Journal of Nuclear Cardiology, pp. 1-4, 2017.
-
(2017)
Journal of Nuclear Cardiology
, pp. 1-4
-
-
Wells, R.G.1
deKemp, R.A.2
-
4
-
-
84976402078
-
Characterization of the vereos digital photon counting PET system
-
M. Miller, J. Zhang, K. Binzel, J. Griesmer, T. Laurence, M. Narayanan, D. Natarajamani, S. Wang, and M. Knopp, “Characterization of the vereos digital photon counting PET system,” Journal of Nuclear Medicine, Vol. 56, p. 434, 2015.
-
(2015)
Journal of Nuclear Medicine
, vol.56
, pp. 434
-
-
Miller, M.1
Zhang, J.2
Binzel, K.3
Griesmer, J.4
Laurence, T.5
Narayanan, M.6
Natarajamani, D.7
Wang, S.8
Knopp, M.9
-
5
-
-
84982855936
-
Design features and mutual compatibility studies of the time-of-flight PET capable GE SIGNA PET/MR system
-
C.S. Levin, S.H. Maramraju, M.M. Khalighi, T.W. Deller, G. Delso, and F. Jansen, “Design features and mutual compatibility studies of the time-of-flight PET capable GE SIGNA PET/MR system,” IEEE Transactions on Medical Imaging, Vol. 35, No. 8, pp. 1907-1914, 2016.
-
(2016)
IEEE Transactions on Medical Imaging
, vol.35
, Issue.8
, pp. 1907-1914
-
-
Levin, C.S.1
Maramraju, S.H.2
Khalighi, M.M.3
Deller, T.W.4
Delso, G.5
Jansen, F.6
-
7
-
-
85049743671
-
-
March
-
P. Fischer, I. Sacco, R. Dohle, M. Ritzert, and C. Piemonte, “Final report SUBLIMA, WP3—PET/MR detector cubes,” March 2015. http://www.sublima-pet-mr.eu
-
(2015)
Final report SUBLIMA, WP3—PET/MR detector cubes
-
-
Fischer, P.1
Sacco, I.2
Dohle, R.3
Ritzert, M.4
Piemonte, C.5
-
8
-
-
85049742605
-
Very compact, water-cooled SiPM module for PET/MRT applications
-
Friedrichshafen, Germany, September 14-16
-
R. Dohle, T. Rittweg, V. Chernyshev, E. Beyer, J. Goßler, I. Sacco, and P. Fischer, “Very compact, water-cooled SiPM module for PET/MRT applications,” Proceedings EMPC, Friedrichshafen, Germany, September 14-16, 2015.
-
(2015)
Proceedings EMPC
-
-
Dohle, R.1
Rittweg, T.2
Chernyshev, V.3
Beyer, E.4
Goßler, J.5
Sacco, I.6
Fischer, P.7
-
9
-
-
85112132958
-
Development of highly integrated PET/MR detector modules
-
Ph.D. dissertation, Heidelberg University, Heidelberg, November 9, 2016. [10] Y. Mizuno, I. Soga, S. Hirose, O. Tsuboi, and T. Iwai, “Si microchannel cooler integrated with high power amplifiers for base station of mobile communication systems, Proceedings 61st ECTC, Lake Buena Vista, FL, May 31-June 3
-
I. Sacco, “Development of highly integrated PET/MR detector modules,” Ph.D. dissertation, Heidelberg University, Heidelberg, November 9, 2016. [10] Y. Mizuno, I. Soga, S. Hirose, O. Tsuboi, and T. Iwai, “Si microchannel cooler integrated with high power amplifiers for base station of mobile communication systems,” Proceedings 61st ECTC, Lake Buena Vista, FL, pp. 1541-1546, May 31-June 3, 2011.
-
(2011)
, pp. 1541-1546
-
-
Sacco, I.1
-
10
-
-
34249887919
-
A practical implementation of silicon microchannel coolers for high power chips
-
E.G. Colgan, B. Furman, M. Gaynes, W. Graham, N. LaBianca, J.H. Magerlein, R.J. Polastre, M.B. Rothwell, R.J. Bezama, R. Choudhary, K. Marston, H. Toy, J. Wakil, J. Zitz, and R. Schmidt, “A practical implementation of silicon microchannel coolers for high power chips,” IEEE Transactions on Components and Packaging Technologies, Vol. 30, No. 2, pp. 218-225, 2007.
-
(2007)
IEEE Transactions on Components and Packaging Technologies
, vol.30
, Issue.2
, pp. 218-225
-
-
Colgan, E.G.1
Furman, B.2
Gaynes, M.3
Graham, W.4
LaBianca, N.5
Magerlein, J.H.6
Polastre, R.J.7
Rothwell, M.B.8
Bezama, R.J.9
Choudhary, R.10
Marston, K.11
Toy, H.12
Wakil, J.13
Zitz, J.14
Schmidt, R.15
-
11
-
-
85091206132
-
High density interconnect NUV-HD SiPMs: performance assessment (#3284)
-
M-15, Atlanta, GA, October 27
-
A. Ferri, F. Acerbi, A. Gola, D. Krabe, T. Lichtenegger, G. Paternoster, C. Piemonte, and M. Stich, “High density interconnect NUV-HD SiPMs: performance assessment (#3284),” IEEE Nuclear Science Symposium & Medical Imaging Conference, MIC Poster Session III, M-15, Atlanta, GA, October 27, 2017.
-
(2017)
IEEE Nuclear Science Symposium & Medical Imaging Conference, MIC Poster Session III
-
-
Ferri, A.1
Acerbi, F.2
Gola, A.3
Krabe, D.4
Lichtenegger, T.5
Paternoster, G.6
Piemonte, C.7
Stich, M.8
-
12
-
-
78651300152
-
Adapted assembly processes for flip-chip technology with solder bumps of 50 mm or 40 mm diameter
-
Berlin, Germany, September 13-16
-
R. Dohle, F. Schüßler, J. Goßler, T. Oppert, and J. Franke, “Adapted assembly processes for flip-chip technology with solder bumps of 50 mm or 40 mm diameter,” 3rd Electronic Systems-Integration Technology Conference, Berlin, Germany, September 13-16, 2010.
-
(2010)
3rd Electronic Systems-Integration Technology Conference
-
-
Dohle, R.1
Schüßler, F.2
Goßler, J.3
Oppert, T.4
Franke, J.5
-
13
-
-
84879958538
-
Accelerated life tests of flip-chips with solder balls down to 30 mm diameter
-
Long Beach, California, October 9-13
-
R. Dohle, S. Härter, J. Goßler, and J. Franke, “Accelerated life tests of flip-chips with solder balls down to 30 mm diameter,” 44th International Symposium on Microelectronics, Long Beach, California, October 9-13, 2011.
-
(2011)
44th International Symposium on Microelectronics
-
-
Dohle, R.1
Härter, S.2
Goßler, J.3
Franke, J.4
-
14
-
-
84959362829
-
Development of new scintillators for medical applications
-
P. Lecoq, “Development of new scintillators for medical applications,” Nuclear Instruments and Methods in Physics Research A, Vol. 809, pp. 130-139, 2016.
-
(2016)
Nuclear Instruments and Methods in Physics Research A
, vol.809
, pp. 130-139
-
-
Lecoq, P.1
-
15
-
-
84928207526
-
Recent R&D trends in inorganic single-crystal scintillator materials for radiation detection
-
M. Nikl and A. Yoshikawa, “Recent R&D trends in inorganic single-crystal scintillator materials for radiation detection,” Advanced Optical Materials, Vol. 3, No. 4, pp. 463-481, 2015.
-
(2015)
Advanced Optical Materials
, vol.3
, Issue.4
, pp. 463-481
-
-
Nikl, M.1
Yoshikawa, A.2
-
16
-
-
84930958818
-
Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca
-
M.V. Nemallapudi, S. Gundacker, P. Lecoq, E. Auffray, A. Ferri, A. Gola, and C. Piemonte, “Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca,” Physics in Medicine and Biology, Vol. 60, pp. 4635-4649, 2015.
-
(2015)
Physics in Medicine and Biology
, vol.60
, pp. 4635-4649
-
-
Nemallapudi, M.V.1
Gundacker, S.2
Lecoq, P.3
Auffray, E.4
Ferri, A.5
Gola, A.6
Piemonte, C.7
-
17
-
-
85091216969
-
Realizing PET systems with 100 ps FWHM coincidence timing resolution
-
San Diego, California, United States, August 28-September 1
-
J. Cates and C.S. Levin, “Realizing PET systems with 100 ps FWHM coincidence timing resolution,” SPIE Optical Engineering and Applications, Proceedings of SPIE Volume 9969, Radiation Detectors, Systems and Applications XVII, San Diego, California, United States, August 28-September 1, 2016.
-
(2016)
SPIE Optical Engineering and Applications, Proceedings of SPIE Volume 9969, Radiation Detectors, Systems and Applications XVII
-
-
Cates, J.1
Levin, C.S.2
-
18
-
-
84880920904
-
Characterization of the first FBK high-density cell silicon photomultiplier technology
-
C. Piemonte, A. Ferri, A. Gola, T. Pro, N. Serra, A. Tarolli, and N. Zorzi, “Characterization of the first FBK high-density cell silicon photomultiplier technology,” IEEE Transactions on Electron Devices, Vol. 60, No. 8, pp. 2567-2573, 2013.
-
(2013)
IEEE Transactions on Electron Devices
, vol.60
, Issue.8
, pp. 2567-2573
-
-
Piemonte, C.1
Ferri, A.2
Gola, A.3
Pro, T.4
Serra, N.5
Tarolli, A.6
Zorzi, N.7
-
19
-
-
84906262104
-
Performance of FBK high-density SiPMs in scintillation spectrometry
-
M. Grodzicka, M. Moszynski, ´ T. Szczesniak, ´ A. Ferri, C. Piemonte, M. Szawłowski, A. Gola, K. Grodzicki, and A. Tarolli, “Performance of FBK high-density SiPMs in scintillation spectrometry,” Journal of Instrumentation, Vol. 9, pp. 1-18, 2014.
-
(2014)
Journal of Instrumentation
, vol.9
, pp. 1-18
-
-
Grodzicka, M.1
Moszynski, M.2
Szczesniak, T.3
Ferri, A.4
Piemonte, C.5
Szawłowski, M.6
Gola, A.7
Grodzicki, K.8
Tarolli, A.9
-
21
-
-
84902212337
-
Enhancement of hotspot cooling with diamond heat spreader on Cu microchannel heat sink for GaN on Si device
-
Y. Han, B.L. Lau, X. Zhang, Y.C. Leong, and K.F. Choo, “Enhancement of hotspot cooling with diamond heat spreader on Cu microchannel heat sink for GaN on Si device,” IEEE Transactions on Components, Packaging, and Manufacturing Technology, Vol. 4, No. 6, pp. 983-990, 2014.
-
(2014)
IEEE Transactions on Components, Packaging, and Manufacturing Technology
, vol.4
, Issue.6
, pp. 983-990
-
-
Han, Y.1
Lau, B.L.2
Zhang, X.3
Leong, Y.C.4
Choo, K.F.5
-
22
-
-
85030753743
-
Monolithic integration of a micropin-fin heat sink in a 28-nm FPGA
-
T.E. Sarvey, Y. Zhang, C. Cheung, R. Gutala, A. Rahman, A. Dasu, and M.S. Bakir, “Monolithic integration of a micropin-fin heat sink in a 28-nm FPGA,” IEEE Transactions on Components, Packaging, and Manufacturing Technology, Vol. 7, No. 10, pp. 1617-1624, 2017.
-
(2017)
IEEE Transactions on Components, Packaging, and Manufacturing Technology
, vol.7
, Issue.10
, pp. 1617-1624
-
-
Sarvey, T.E.1
Zhang, Y.2
Cheung, C.3
Gutala, R.4
Rahman, A.5
Dasu, A.6
Bakir, M.S.7
-
23
-
-
79958037890
-
Focus on time-of-flight PET: the benefits of improved time resolution
-
M. Conti, “Focus on time-of-flight PET: the benefits of improved time resolution,” European Journal of Nuclear Medicine and Molecular Imaging, Vol. 38, No. 6, pp. 1147-1157, 2011.
-
(2011)
European Journal of Nuclear Medicine and Molecular Imaging
, vol.38
, Issue.6
, pp. 1147-1157
-
-
Conti, M.1
-
24
-
-
40449116151
-
Benefit of time-of-flight in PET: experimental and clinical results
-
J. Karp, S. Surti, M. Daube-Witherspoon, and G. Muehllehner, “Benefit of time-of-flight in PET: experimental and clinical results,” Journal of Nuclear Medicine, No. 49, p. 462f, 2008.
-
(2008)
Journal of Nuclear Medicine
, Issue.49
, pp. 462f
-
-
Karp, J.1
Surti, S.2
Daube-Witherspoon, M.3
Muehllehner, G.4
-
25
-
-
0142126690
-
Time of flight in PET revisited
-
W.W. Moses, “Time of flight in PET revisited,” IEEE Transactions on Nuclear Science, Vol. 50, No. 5, pp. 1325-1330, 2003.
-
(2003)
IEEE Transactions on Nuclear Science
, vol.50
, Issue.5
, pp. 1325-1330
-
-
Moses, W.W.1
-
26
-
-
33646388372
-
Investigation of time-of-flight benefit 3-D PET
-
S. Surti, J. Karp, L. Popescu, M. Daube-Witherspoon, and M. Werner, “Investigation of time-of-flight benefit 3-D PET,” IEEE Transactions on Medical Imaging, Vol. 25, No. 5, pp. 529-538, 2006.
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, Issue.5
, pp. 529-538
-
-
Surti, S.1
Karp, J.2
Popescu, L.3
Daube-Witherspoon, M.4
Werner, M.5
-
27
-
-
85091224209
-
Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in admistered activity in cardiac PET studies
-
I.S. Armstrong, C.M. Tonge, and P. Arumugam, “Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in admistered activity in cardiac PET studies,” Journal of Nuclear Cardiology, pp. 1-8, 2017.
-
(2017)
Journal of Nuclear Cardiology
, pp. 1-8
-
-
Armstrong, I.S.1
Tonge, C.M.2
Arumugam, P.3
-
28
-
-
69349096036
-
Exposure to low-dose ionizing radiation from medical imaging procedures
-
R. Fazel, H.M. Krumholz, Y. Wang, J.S. Ross, J. Chen, H.H. Ting, N.D. Shah, K. Nasir, A.J. Einstein, and B.K. Nallamothu, “Exposure to low-dose ionizing radiation from medical imaging procedures,” The New England Journal of Medicine, Vol. 361, pp. 849-857, 2009.
-
(2009)
The New England Journal of Medicine
, vol.361
, pp. 849-857
-
-
Fazel, R.1
Krumholz, H.M.2
Wang, Y.3
Ross, J.S.4
Chen, J.5
Ting, H.H.6
Shah, N.D.7
Nasir, K.8
Einstein, A.J.9
Nallamothu, B.K.10
-
29
-
-
84940399378
-
Dose optimization in TOF-PET/MR compared to TOF-PET/CT
-
M.A. Queiroz, G. Delso, S. Wollenweber, T. Deller, K. Zeimpekis, M. Huellner, F. de Galiza Barbosa, G. von Schulthess, and P. Veit-Haibach, “Dose optimization in TOF-PET/MR compared to TOF-PET/CT,” PLoS One, Vol. 10, No. 7, pp. e0128842, 2015.
-
(2015)
PLoS One
, vol.10
, Issue.7
, pp. e0128842
-
-
Queiroz, M.A.1
Delso, G.2
Wollenweber, S.3
Deller, T.4
Zeimpekis, K.5
Huellner, M.6
de Galiza Barbosa, F.7
von Schulthess, G.8
Veit-Haibach, P.9
-
31
-
-
85014439058
-
Pediatric nuclear medicine and its development as a specialty
-
I.R. Bielsa, “Pediatric nuclear medicine and its development as a specialty,” Seminars in Nuclear Medicine, Vol. 47, No. 2, pp. 102-109, 2017.
-
(2017)
Seminars in Nuclear Medicine
, vol.47
, Issue.2
, pp. 102-109
-
-
Bielsa, I.R.1
-
32
-
-
85012095868
-
A sub-millimeter resolution detector module for small-animal PET applications
-
I. Sacco, R. Dohle, P. Fischer, A. Gola, C. Piemonte, and M. Ritzert, “A sub-millimeter resolution detector module for small-animal PET applications,” Journal of Instrumentation: An IOP and SISSA Journal, Vol. 12, No. 1, C01006, 2017.
-
(2017)
Journal of Instrumentation: An IOP and SISSA Journal
, vol.12
, Issue.1
, pp. C01006
-
-
Sacco, I.1
Dohle, R.2
Fischer, P.3
Gola, A.4
Piemonte, C.5
Ritzert, M.6
-
33
-
-
85009455165
-
New-generation small animal positron emission tomography system for molecular imaging
-
S. Abbaszadeh and C.S. Levin, “New-generation small animal positron emission tomography system for molecular imaging,” Journal of Medical Imaging (Bellingham, Wash.), Vol. 4, No. 1, p. 011008, 2017.
-
(2017)
Journal of Medical Imaging (Bellingham, Wash.)
, vol.4
, Issue.1
, pp. 011008
-
-
Abbaszadeh, S.1
Levin, C.S.2
-
34
-
-
79952792137
-
Improvement in lesion detection with whole-body oncologic time-of-flight PET
-
G. El Fakhri, S. Surti, C.M. Trott, J. Scheuermann, and J.S. Karp, “Improvement in lesion detection with whole-body oncologic time-of-flight PET,” Journal of Nuclear Medicine, Vol. 52, No. 3, pp. 347-353, 2011.
-
(2011)
Journal of Nuclear Medicine
, vol.52
, Issue.3
, pp. 347-353
-
-
El Fakhri, G.1
Surti, S.2
Trott, C.M.3
Scheuermann, J.4
Karp, J.S.5
-
35
-
-
85017564618
-
Technical and instrumentational foundations of PET/MRI
-
I. Rausch, H.H. Quick, J. Cal-Conzalez, B. Sattler, R. Boellard, and T. Beyer, “Technical and instrumentational foundations of PET/MRI,” European Journal of Radiology, Vol. 94, pp. A3-A13, 2017.
-
(2017)
European Journal of Radiology
, vol.94
, pp. A3-A13
-
-
Rausch, I.1
Quick, H.H.2
Cal-Conzalez, J.3
Sattler, B.4
Boellard, R.5
Beyer, T.6
-
36
-
-
85058447152
-
Applications of innovative SiPM-based PVT scintillator detectors
-
Atlanta, Georgia, October 23
-
M. Meshkian, C. Allwork, U. Gendotti, M. Ellis, and P. Schotanus, “Applications of innovative SiPM-based PVT scintillator detectors,” Nuclear Science Symposium, session “Instrumentation for Homeland and National Security,” Atlanta, Georgia, October 23, 2017.
-
(2017)
Nuclear Science Symposium, session “Instrumentation for Homeland and National Security
-
-
Meshkian, M.1
Allwork, C.2
Gendotti, U.3
Ellis, M.4
Schotanus, P.5
-
37
-
-
85021098741
-
Ultra-high cell density silicon photomultipliers with high detection efficiency
-
May 1
-
F. Acerbi, A. Gola, V.V. Regazzoni, G. Paternoster, G. Borghi, C. Piemonte, and N. Zorzi, “Ultra-high cell density silicon photomultipliers with high detection efficiency,” Proceedings SPIE #2959, Advanced Photon Counting Techniques XI, Vol. 10212, May 1, 2017.
-
(2017)
Proceedings SPIE #2959, Advanced Photon Counting Techniques XI
, vol.10212
-
-
Acerbi, F.1
Gola, A.2
Regazzoni, V.V.3
Paternoster, G.4
Borghi, G.5
Piemonte, C.6
Zorzi, N.7
-
38
-
-
84990241589
-
Clinical application of PET/MRI in oncology
-
H. Sotoudeh, A. Sharma, K.J. Fowler, and J. McConathy, “Clinical application of PET/MRI in oncology,” Journal of Magnetic Resonance Imaging, Vol. 44, No. 2, pp. 265-276, 2016.
-
(2016)
Journal of Magnetic Resonance Imaging
, vol.44
, Issue.2
, pp. 265-276
-
-
Sotoudeh, H.1
Sharma, A.2
Fowler, K.J.3
McConathy, J.4
-
39
-
-
84964053167
-
Positron emission tomography
-
A. Del Guerra, N. Belcari, and M. Bisogni, “Positron emission tomography,” Rivista del Nuovo Cimento, Vol. 39, No. 4, pp. 156-182, 2016.
-
(2016)
Rivista del Nuovo Cimento
, vol.39
, Issue.4
, pp. 156-182
-
-
Del Guerra, A.1
Belcari, N.2
Bisogni, M.3
-
40
-
-
85039848632
-
Image-derived input function estimation on a TOF-enabled PET/MR for cerebral blood flow mapping
-
M.M. Khalighi, T.W. Deller, A.P. Fan, P.K. Gulaka, B. Shen, P. Singh, J.H. Park, F.T. Chin, and G. Zaharchuk, “Image-derived input function estimation on a TOF-enabled PET/MR for cerebral blood flow mapping,” Journal of Cerebral Blood Flow and Metabolism, Vol. 38, pp. 126-135, 2017.
-
(2017)
Journal of Cerebral Blood Flow and Metabolism
, vol.38
, pp. 126-135
-
-
Khalighi, M.M.1
Deller, T.W.2
Fan, A.P.3
Gulaka, P.K.4
Shen, B.5
Singh, P.6
Park, J.H.7
Chin, F.T.8
Zaharchuk, G.9
-
41
-
-
85083839265
-
Current status and future direction of PET/MR in cardiology
-
A. Masuda and Y. Takeishi, “Current status and future direction of PET/MR in cardiology,” Annals of Nuclear Cardiology, Vol. 3, No. 1, pp. 73-79, 2017.
-
(2017)
Annals of Nuclear Cardiology
, vol.3
, Issue.1
, pp. 73-79
-
-
Masuda, A.1
Takeishi, Y.2
-
42
-
-
85091221665
-
An integrated circuit read-out for TOF-PET detectors for PET/MRI
-
San Diego, California, United States, September 19
-
I. Sacco, C.-M. Chang, B. Lee, M. Ritzert, P. Fischer, and C. S. Levin, “An integrated circuit read-out for TOF-PET detectors for PET/MRI,” Proceedings SPIE 10393, Radiation Detectors in Medicine, Industry, and National Security, San Diego, California, United States, September 19, 2017.
-
(2017)
Proceedings SPIE 10393, Radiation Detectors in Medicine, Industry, and National Security
-
-
Sacco, I.1
Chang, C.-M.2
Lee, B.3
Ritzert, M.4
Fischer, P.5
Levin, C. S.6
-
43
-
-
85091219919
-
Medical imaging and diagnostics: current status and future trends
-
San Diego, CA, January 23
-
S. Chandra and F. Peechta, “Medical imaging and diagnostics: current status and future trends,” Keynote Presentation at IMAPS Advanced Technology Workshop on Advanced Packaging for Medical Microelectronics, San Diego, CA, January 23, 2018.
-
(2018)
Keynote Presentation at IMAPS Advanced Technology Workshop on Advanced Packaging for Medical Microelectronics
-
-
Chandra, S.1
Peechta, F.2
|