메뉴 건너뛰기




Volumn , Issue , 2007, Pages 563-565

Aluminium printed circuit board technology for biomedical micro-devices

Author keywords

Aluminium; Biomedical microdevice; Lab on a Chip; Microfluidics; PCB

Indexed keywords

ALUMINUM; BIOCOMPATIBILITY; TIMING CIRCUITS;

EID: 85088678286     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (7)
  • 1
    • 0037096666 scopus 로고    scopus 로고
    • Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
    • D.R. Reyes et al., Micro Total Analysis Systems. 1. Introduction, Theory, and Technology, Anal. Chem., 74, pp. 2623, (2002).
    • (2002) Anal. Chem , vol.74 , pp. 2623
    • Reyes, D.R.1
  • 2
    • 0035443367 scopus 로고    scopus 로고
    • Fluidic Microsystems based on printed circuit board technology
    • A. Wego et al., Fluidic Microsystems based on printed circuit board technology, J. Micromech. Microeng., 11, pp. 528, (2001).
    • (2001) J. Micromech. Microeng , vol.11 , pp. 528
    • Wego, A.1
  • 3
    • 0035305074 scopus 로고    scopus 로고
    • An Integrated Micro Cooling System for Electronic Circuits
    • J. Schütze et al., An Integrated Micro Cooling System for Electronic Circuits, IEEE Transactions on industrial electronics, 48, pp. 281, (2001).
    • (2001) IEEE Transactions on industrial electronics , vol.48 , pp. 281
    • Schütze, J.1
  • 4
    • 0035251495 scopus 로고    scopus 로고
    • Miniature valveless pumps based on printed circuit board technique
    • N.T. Nguyen, X. Huang, Miniature valveless pumps based on printed circuit board technique, Sensors and Actuators A, 88, pp. 104, (2001).
    • (2001) Sensors and Actuators A , vol.88 , pp. 104
    • Nguyen, N.T.1    Huang, X.2
  • 5
    • 0034667772 scopus 로고    scopus 로고
    • Supra-agonist peptides enhance the reactivation of memory CTL responses
    • F. Micheletti et al., Supra-agonist peptides enhance the reactivation of memory CTL responses, J. Immunol., 165, pp. 4264, (2000).
    • (2000) J. Immunol , vol.165 , pp. 4264
    • Micheletti, F.1
  • 6
    • 0030889206 scopus 로고    scopus 로고
    • Human cytotoxic T lymphocyte responses to Epstein-Barr virus infection
    • A.B. Rickinson and D.J. Moss, Human cytotoxic T lymphocyte responses to Epstein-Barr virus infection, Annu. Rev. Immunol., 15, pp. 405, (1997).
    • (1997) Annu. Rev. Immunol , vol.15 , pp. 405
    • Rickinson, A.B.1    Moss, D.J.2
  • 7
    • 50049118753 scopus 로고    scopus 로고
    • An integrated electronic meniscus sensor for measurement of evaporative flow
    • D. Gazzola et al., An integrated electronic meniscus sensor for measurement of evaporative flow, Transducers Conference, (2007).
    • (2007) Transducers Conference