메뉴 건너뛰기




Volumn 8, Issue 1, 2018, Pages

Erratum to: Closed-type pre-treatment device for point-of-care testing of sputum (Scientific Reports, (2018), 8, 1, (16508), 10.1038/s41598-018-34781-1);Closed-type pre-treatment device for point-of-care testing of sputum

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOSAFETY; DIAGNOSIS; EXTRACTION; GENOME; HUMAN; HUMAN TISSUE; LIQUEFACTION; MICROORGANISM DETECTION; POINT OF CARE TESTING; SPUTUM;

EID: 85056102070     PISSN: None     EISSN: 20452322     Source Type: Journal    
DOI: 10.1038/s41598-018-36359-3     Document Type: Erratum
Times cited : (5)

References (23)
  • 1
    • 85028066593 scopus 로고    scopus 로고
    • Estimates of the global, regional, and national morbidity, mortality, and aetiologies of lower respiratory tract infections in 195 countries: A systematic analysis for the Global Burden of Disease Study
    • 2015
    • GBD 2015 LRI Collaborators, Estimates of the global, regional, and national morbidity, mortality, and aetiologies of lower respiratory tract infections in 195 countries: a systematic analysis for the Global Burden of Disease Study. Lancet Infect Dis. 2017, 17, 1133–1161 (2015)
    • (2017) Lancet Infect Dis , vol.17 , pp. 1133-1161
  • 2
    • 84958161929 scopus 로고    scopus 로고
    • Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination
    • COI: 1:STN:280:DC%2BC28vksFagtw%3D%3D
    • Otter, J. A. et al. Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination. J Hosp Infect. 92, 235–250 (2016)
    • (2016) J Hosp Infect. , vol.92 , pp. 235-250
    • Otter, J.A.1
  • 3
    • 84906567651 scopus 로고    scopus 로고
    • Middle East respiratory syndrome (MERS): a new zoonotic viral pneumonia
    • Cunha, C. B. & Opal, S. M. Middle East respiratory syndrome (MERS): a new zoonotic viral pneumonia. Virulence. 5, 650–654 (2014)
    • (2014) Virulence. , vol.5 , pp. 650-654
    • Cunha, C.B.1    Opal, S.M.2
  • 4
    • 85021854596 scopus 로고    scopus 로고
    • Evaluation of an automated protocol for efficient and reliable DNA extraction of dietary samples
    • Wallinger, C. et al. Evaluation of an automated protocol for efficient and reliable DNA extraction of dietary samples. Ecol Evol. 7, 6382–6389 (2017)
    • (2017) Ecol Evol. , vol.7 , pp. 6382-6389
    • Wallinger, C.1
  • 5
    • 84961728785 scopus 로고    scopus 로고
    • Comparison of an automated nucleic acid extraction system with the column-based procedure
    • COI: 1:CAS:528:DC%2BC1cXlsVKltrY%3D
    • Frickmann, H. et al. Comparison of an automated nucleic acid extraction system with the column-based procedure. Eur J Microbiol Immunol (Bp). 5, 94–102 (2015)
    • (2015) Eur J Microbiol Immunol (Bp). , vol.5 , pp. 94-102
    • Frickmann, H.1
  • 6
    • 0034750371 scopus 로고    scopus 로고
    • Multicenter study of a commercial, automated polymerase chain reaction system for the rapid detection of mycobacterium tuberculosis in respiratory specimens in routine clinical practice
    • COI: 1:CAS:528:DC%2BD38XitFeltA%3D%3D
    • Bogard, M. et al. Multicenter study of a commercial, automated polymerase chain reaction system for the rapid detection of mycobacterium tuberculosis in respiratory specimens in routine clinical practice. Eur J Clin Microbiol Infect Dis. 20, 724–731 (2001)
    • (2001) Eur J Clin Microbiol Infect Dis. , vol.20 , pp. 724-731
    • Bogard, M.1
  • 7
    • 85018672424 scopus 로고    scopus 로고
    • Multiplexed Point-of-Care Testing – xPOCT
    • COI: 1:CAS:528:DC%2BC2sXmtFGns70%3D
    • Dincer, C. et al. Multiplexed Point-of-Care Testing – xPOCT. Trends Biotechnol. 35, 728–742 (2017)
    • (2017) Trends Biotechnol. , vol.35 , pp. 728-742
    • Dincer, C.1
  • 8
    • 85030719506 scopus 로고    scopus 로고
    • A paper/polymer hybrid CD-like microfluidic SpinChip integrated with DNA-functionalized graphene oxide nanosensors for multiplex qLAMP detection
    • COI: 1:CAS:528:DC%2BC2sXhtFSls73M
    • Dou, M. et al. A paper/polymer hybrid CD-like microfluidic SpinChip integrated with DNA-functionalized graphene oxide nanosensors for multiplex qLAMP detection. Chem Commun. 53, 10886–10889 (2017)
    • (2017) Chem Commun. , vol.53 , pp. 10886-10889
    • Dou, M.1
  • 9
    • 85021997178 scopus 로고    scopus 로고
    • A sensitive colorimetric assay system for nucleic acid detection based on isothermal signal amplification technology
    • COI: 1:CAS:528:DC%2BC2sXhtFCgsrnL
    • Hu, B. et al. A sensitive colorimetric assay system for nucleic acid detection based on isothermal signal amplification technology. Anal Bioanal Chem. 409, 4819–4825 (2017)
    • (2017) Anal Bioanal Chem. , vol.409 , pp. 4819-4825
    • Hu, B.1
  • 10
    • 85016172166 scopus 로고    scopus 로고
    • Evaluation of Alere i RSV for Rapid Detection of Respiratory Syncytial Virus in Children Hospitalized with Acute Respiratory Tract Infection
    • COI: 1:CAS:528:DC%2BC1cXktFGrsLk%3D
    • Peters, R. M. et al. Evaluation of Alere i RSV for Rapid Detection of Respiratory Syncytial Virus in Children Hospitalized with Acute Respiratory Tract Infection. J Clin Microbiol. 55, 1032–1036 (2017)
    • (2017) J Clin Microbiol. , vol.55 , pp. 1032-1036
    • Peters, R.M.1
  • 11
    • 84942318761 scopus 로고    scopus 로고
    • An acoustofluidic sputum liquefier
    • COI: 1:CAS:528:DC%2BC2MXhtVWjt73E
    • Huang, P. H. et al. An acoustofluidic sputum liquefier. Lab Chip. 15, 3125–313 (2015)
    • (2015) Lab Chip. , vol.15 , pp. 3125-3313
    • Huang, P.H.1
  • 12
    • 84955315178 scopus 로고    scopus 로고
    • Pilot study of a rapid and minimally instrumented sputum sample preparation method for molecular diagnosis of tuberculosis
    • COI: 1:CAS:528:DC%2BC28Xht1erur0%3D
    • Ferguson, T. M. et al. Pilot study of a rapid and minimally instrumented sputum sample preparation method for molecular diagnosis of tuberculosis. Sci Rep. 6, 19541 (2016)
    • (2016) Sci Rep. , vol.6
    • Ferguson, T.M.1
  • 13
    • 84940092686 scopus 로고    scopus 로고
    • Evaluation of the Efficiency of the Sample Inactivation Reagent in the Abbott RealTime MTB Assay for Inactivation of Mycobacterium tuberculosis
    • COI: 1:CAS:528:DC%2BC28Xls1ygsL0%3D
    • Qi, C. et al. Evaluation of the Efficiency of the Sample Inactivation Reagent in the Abbott RealTime MTB Assay for Inactivation of Mycobacterium tuberculosis. J Clin Microbiol. 53, 3001–3002 (2015)
    • (2015) J Clin Microbiol. , vol.53 , pp. 3001-3002
    • Qi, C.1
  • 14
    • 84928742813 scopus 로고    scopus 로고
    • Electromechanical cell lysis using a portable audio device: enabling challenging sample preparation at the point-of-care
    • COI: 1:CAS:528:DC%2BC2MXktlKjsb4%3D
    • Buser, J. R. et al. Electromechanical cell lysis using a portable audio device: enabling challenging sample preparation at the point-of-care. Lab Chip. 15, 1994–1997 (2015)
    • (2015) Lab Chip. , vol.15 , pp. 1994-1997
    • Buser, J.R.1
  • 15
    • 0036669964 scopus 로고    scopus 로고
    • Laboratory diagnosis and biosafety issues of biological warfare agents
    • COI: 1:CAS:528:DC%2BD38XnsFyru7c%3D
    • Nulens, E. & Voss, A. Laboratory diagnosis and biosafety issues of biological warfare agents. Clin Microbiol Infect. 8, 455–466 (2002)
    • (2002) Clin Microbiol Infect. , vol.8 , pp. 455-466
    • Nulens, E.1    Voss, A.2
  • 16
    • 0141800047 scopus 로고    scopus 로고
    • Comparison of three methods for differential cell count in induced sputum
    • Saraiva-Romanholo, B. M. et al. Comparison of three methods for differential cell count in induced sputum. Chest 124, 1060–1066 (2003)
    • (2003) Chest , vol.124 , pp. 1060-1066
    • Saraiva-Romanholo, B.M.1
  • 17
    • 84922432058 scopus 로고    scopus 로고
    • Does the duration of lysis affect the sensitivity of the in vitro alkaline comet assay?
    • COI: 1:CAS:528:DC%2BC2MXjvFansb8%3D
    • Enciso, J. M. et al. Does the duration of lysis affect the sensitivity of the in vitro alkaline comet assay? Mutagenesis. 30, 21–28 (2015)
    • (2015) Mutagenesis. , vol.30 , pp. 21-28
    • Enciso, J.M.1
  • 18
    • 85017163877 scopus 로고    scopus 로고
    • Paper-based device with on-chip reagent storage for rapid extraction of DNA from biological samples
    • COI: 1:CAS:528:DC%2BC2sXlsleitb0%3D
    • Tang, R. et al. Paper-based device with on-chip reagent storage for rapid extraction of DNA from biological samples. Microchimica Acta. 184, 2141–2150 (2017)
    • (2017) Microchimica Acta. , vol.184 , pp. 2141-2150
    • Tang, R.1
  • 19
    • 85016455810 scopus 로고    scopus 로고
    • Fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection
    • COI: 1:CAS:528:DC%2BC2sXjvVygsL8%3D
    • Tang, A. et al. Fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection. Lab Chip. 17, 1270–1279 (2017)
    • (2017) Lab Chip. , vol.17 , pp. 1270-1279
    • Tang, A.1
  • 20
    • 84923097199 scopus 로고    scopus 로고
    • A simple and rapid DNA extraction method from whole blood for highly sensitive detection and quantitation of HIV-1 proviral DNA by real-time PCR
    • COI: 1:CAS:528:DC%2BC2MXjtVSgs7Y%3D
    • McFall, S. M. et al. A simple and rapid DNA extraction method from whole blood for highly sensitive detection and quantitation of HIV-1 proviral DNA by real-time PCR. J Virol Methods. 214, 37–42 (2015)
    • (2015) J Virol Methods. , vol.214 , pp. 37-42
    • McFall, S.M.1
  • 21
    • 0035999838 scopus 로고    scopus 로고
    • Optimizing sputum methodology
    • COI: 1:STN:280:DC%2BD383lsFShuw%3D%3D
    • Erin, E. M. et al. Optimizing sputum methodology. Clinical & Experimental Allergy 32, 653–657 (2002)
    • (2002) Clinical & Experimental Allergy , vol.32 , pp. 653-657
    • Erin, E.M.1
  • 22
    • 0141800047 scopus 로고    scopus 로고
    • Comparison of three methods for differential cell count in induced sputum
    • Saraiva-Romanholo, B. M. et al. Comparison of three methods for differential cell count in induced sputum. Chest 124(3), 1060–1066 (2003)
    • (2003) Chest , vol.124 , Issue.3 , pp. 1060-1066
    • Saraiva-Romanholo, B.M.1
  • 23
    • 85012069832 scopus 로고    scopus 로고
    • Detection of Mycobacterium chelonae, Mycobacterium abscessus Group, and Mycobacterium fortuitum Complex by a Multiplex Real-Time PCR Directly from Clinical Samples Using the BD MAX System
    • COI: 1:CAS:528:DC%2BC2sXisF2ltLY%3D
    • Rocchetti, T. T. et al. Detection of Mycobacterium chelonae, Mycobacterium abscessus Group, and Mycobacterium fortuitum Complex by a Multiplex Real-Time PCR Directly from Clinical Samples Using the BD MAX System. The Journal of Molecular Diagnostics 19(2), 295–302 (2017)
    • (2017) The Journal of Molecular Diagnostics , vol.19 , Issue.2 , pp. 295-302
    • Rocchetti, T.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.