메뉴 건너뛰기




Volumn 17, Issue 10, 2019, Pages 5609-5629

Damage assessment and the effectiveness of prevention: the response of ordinary unreinforced masonry buildings in Norcia during the Central Italy 2016–2017 seismic sequence

Author keywords

Damage; Masonry aggregates; Seismic sequence; Strengthening interventions; Usability

Indexed keywords

AGGREGATES; DAMAGE DETECTION; MASONRY CONSTRUCTION; MASONRY MATERIALS; ROOFS; SURVEYS;

EID: 85051749519     PISSN: 1570761X     EISSN: 15731456     Source Type: Journal    
DOI: 10.1007/s10518-018-0448-z     Document Type: Article
Times cited : (71)

References (29)
  • 3
    • 84856850810 scopus 로고    scopus 로고
    • FRPRCS-10, in conjunction with the ACI Spring 2011 convention; Tampa, FL; 2 April 2011 through 4 April 2011; Code 88497, ACI SP-275, ACI SP-275-44, 275
    • Balsamo A, Di Ludovico M, Prota A, Manfredi G (2011) Masonry Walls Strengthened with Innovative Composites. American Concrete Institute, ACI Special Publication, 10th International symposium on fiber-reinforced polymer reinforcement for concrete structures 2011, FRPRCS-10, in conjunction with the ACI Spring 2011 convention; Tampa, FL; 2 April 2011 through 4 April 2011; Code 88497, ACI SP-275, ACI SP-275-44, vol 2(275 SP), pp 769–786. ISBN:0-87031-412-2
    • (2011) 10Th International Symposium on Fiber-Reinforced Polymer Reinforcement for Concrete Structures 2011 , vol.2 , pp. 769-786
    • Balsamo, A.1    Di Ludovico, M.2    Prota, A.3    Manfredi, G.4
  • 4
  • 5
    • 85052599736 scopus 로고    scopus 로고
    • Alcune considerazioni in materia di analisi e di interventi sugli edifici in muratura in zona sismica
    • Genova 25–29 gennaio 2004, in Italian
    • Borri A, De Maria A (2004b) Alcune considerazioni in materia di analisi e di interventi sugli edifici in muratura in zona sismica. In: XI Congresso Nazionale “L’ingegneria Sismica in Italia”, Genova 25–29 gennaio 2004, pp H1-4 (in Italian)
    • (2004) XI Congresso Nazionale “L’ingegneria Sismica in Italia” , pp. 1-4
    • Borri, A.1    de Maria, A.2
  • 6
    • 84938291630 scopus 로고    scopus 로고
    • A method for the analysis and classification of historic masonry
    • Borri A, Corradi M, Castori G, De Maria A (2015) A method for the analysis and classification of historic masonry. Bull Earthq Eng 13:2647–2665. 10.1007/s10518-015-9731-4
    • (2015) Bull Earthq Eng , vol.13 , pp. 2647-2665
    • Borri, A.1    Corradi, M.2    Castori, G.3    De Maria, A.4
  • 7
    • 85073490817 scopus 로고    scopus 로고
    • and Mediterranean area 760 B.C.—1500
    • Catalogue of strong earthquake in Italy 461 B.C.— 1997 and Mediterranean area 760 B.C.—1500
    • (1997)
  • 9
    • 84994316249 scopus 로고    scopus 로고
    • Estimation of repair costs for RC and masonry residential buildings based on damage data collected by post-earthquake visual inspection
    • De Martino G, Di Ludovico M, Prota A, Moroni C, Manfredi G, Dolce M (2017) Estimation of repair costs for RC and masonry residential buildings based on damage data collected by post-earthquake visual inspection. Bull Earthq Eng 15(4):1681–1706. 10.1007/s10518-016-0039-9
    • (2017) Bull Earthq Eng , vol.15 , Issue.4 , pp. 1681-1706
    • De Martino, G.1    Di Ludovico, M.2    Prota, A.3    Moroni, C.4    Manfredi, G.5    Dolce, M.6
  • 10
    • 84981214236 scopus 로고    scopus 로고
    • Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake—part II: “heavy damage” reconstruction
    • Di Ludovico M, Prota A, Moroni C, Manfredi G, Dolce M (2017a) Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake—part II: “heavy damage” reconstruction. Bull Earthq Eng 15(2):693–729. 10.1007/s10518-016-9979-3
    • (2017) Bull Earthq Eng , vol.15 , Issue.2 , pp. 693-729
    • Di Ludovico, M.1    Prota, A.2    Moroni, C.3    Manfredi, G.4    Dolce, M.5
  • 11
    • 84957718099 scopus 로고    scopus 로고
    • Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake: part I—“light damage” reconstruction
    • Di Ludovico M, Prota A, Moroni C, Manfredi G, Dolce M (2017b) Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake: part I—“light damage” reconstruction. Bull Earthq Eng 15(2):667–692. 10.1007/s10518-016-9877-8
    • (2017) Bull Earthq Eng , vol.15 , Issue.2 , pp. 667-692
    • Di Ludovico, M.1    Prota, A.2    Moroni, C.3    Manfredi, G.4    Dolce, M.5
  • 14
    • 84928492166 scopus 로고    scopus 로고
    • Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes
    • Gattesco N, Boem I (2015) Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes. Constr Build Mater 88:94–104. 10.1016/j.conbuildmat.2015.04.014
    • (2015) Constr Build Mater , vol.88 , pp. 94-104
    • Gattesco, N.1    Boem, I.2
  • 15
    • 85073482327 scopus 로고    scopus 로고
    • Law n. 64, February 2, 1974 Official Gazette n. 76 of 21/03/1974, Legge n. 64 del 2 Febbraio 1974, G.U. n. 76 del 21/03/1974, Provvedimenti per le costruzioni con particolari prescrizioni per le zone sismiche, in Italian
    • Law n. 64, February 2, 1974 Official Gazette n. 76 of 21/03/1974, “Provisions for constructions with particular regulations for seismic zones”—Legge n. 64 del 2 Febbraio 1974 (G.U. n. 76 del 21/03/1974) “Provvedimenti per le costruzioni con particolari prescrizioni per le zone sismiche” (in Italian)
    • Provisions for constructions with particular regulations for seismic zones
  • 17
    • 84961999822 scopus 로고    scopus 로고
    • Out-of-plane experimental behaviour of T-shaped full scale masonry wall strengthened with composite connections “reconstruction
    • Maddaloni G, Di Ludovico M, Balsamo A, Prota A (2016) Out-of-plane experimental behaviour of T-shaped full scale masonry wall strengthened with composite connections “reconstruction”. Compos B 93(2016):328–343. 10.1016/j.compositesb.2016.03.026
    • (2016) Compos B , vol.93 , Issue.2016 , pp. 328-343
    • Maddaloni, G.1    Di Ludovico, M.2    Balsamo, A.3    Prota, A.4
  • 18
    • 85026816043 scopus 로고    scopus 로고
    • Analysis of the population assistance and returning home in the reconstruction process of the 2009 L’Aquila Earthquake
    • Mannella A, Di Ludovico M, Sabino A, Prota A, Dolce M, Manfredi G (2017) Analysis of the population assistance and returning home in the reconstruction process of the 2009 L’Aquila Earthquake. Sustainability 9(8):1395. 10.3390/su9081395
    • (2017) Sustainability , vol.9 , Issue.8 , pp. 1395
    • Mannella, A.1    Di Ludovico, M.2    Sabino, A.3    Prota, A.4    Dolce, M.5    Manfredi, G.6
  • 19
    • 85073486476 scopus 로고
    • March 3, 1975 Official Gazette n. 93 of 08/04/1975, Decreto Ministeriale del 3 Marzo, (G.U. n. 93 del 08/04/1975) “Approvazione delle Norme tecniche per le costruzioni in zone sismiche” (in Italian)
    • Ministerial Decree, March 3, 1975 Official Gazette n. 93 of 08/04/1975, “Approval of technical guidelines for construction in seismic zones”—Decreto Ministeriale del 3 Marzo 1975 (G.U. n. 93 del 08/04/1975) “Approvazione delle Norme tecniche per le costruzioni in zone sismiche” (in Italian)
    • (1975) Approval of Technical Guidelines for Construction in Seismic Zones
  • 21
    • 85015810992 scopus 로고    scopus 로고
    • Seismic strengthening of masonry vaults with abutments using textile-reinforced mortar
    • Ramaglia G, Lignola GP, Balsamo A, Prota A, Manfredi G (2017) Seismic strengthening of masonry vaults with abutments using textile-reinforced mortar. J Compos Constr. 10.1061/(asce)cc.1943-5614.0000733
    • (2017) J Compos Constr
    • Ramaglia, G.1    Lignola, G.P.2    Balsamo, A.3    Prota, A.4    Manfredi, G.5
  • 22
    • 85073482765 scopus 로고
    • Technical provisions and methodology for repair and strengthening works of buildings damaged by earthquake (art. 38 L:R. 1/7/81 n. 34) - Regione dell’Umbria, Direttive tecniche ed esemplificazione delle metodologie di interventi per la riparazione ed il consolidamento degli edifici danneggiati da eventi sismici (art. 38 L:R. 1/7/81 n. 34) (in Italian)
    • Regione Umbria, 1981—Technical provisions and methodology for repair and strengthening works of buildings damaged by earthquake (art. 38 L:R. 1/7/81 n. 34) - Regione dell’Umbria, Direttive tecniche ed esemplificazione delle metodologie di interventi per la riparazione ed il consolidamento degli edifici danneggiati da eventi sismici (art. 38 L:R. 1/7/81 n. 34) (in Italian)
    • (1981)
  • 23
    • 85073483083 scopus 로고
    • Royal Decree n.193 del 18/04/1909, December 28, 1908 and others listed in the R.D. 15 April 1909. G.U of the Kingdom of Italy n.95 of 22/04/1909”—R.D., Regio Decreto n.193 del 18/04/1909, Norme tecniche ed igieniche obbligatorie per le riparazioni ricostruzioni e nuove costruzioni degli edifici pubblici e privati nei luoghi colpiti dal terremoto del 28 dicembre 1908 e da altri precedenti elencati nel R.D. 15 aprile 1909. G.U del Regno d’Italia n.95 del 22/04/1909 (in Italian)
    • Royal Decree n.193 del 18/04/1909, “Technical guidelines and hygienic standards for repairing and new constructions of public and private buildings in areas affected by the earthquake of December 28, 1908 and others listed in the R.D. 15 April 1909. G.U of the Kingdom of Italy n.95 of 22/04/1909”—R.D., 1909, Regio Decreto n.193 del 18/04/1909, Norme tecniche ed igieniche obbligatorie per le riparazioni ricostruzioni e nuove costruzioni degli edifici pubblici e privati nei luoghi colpiti dal terremoto del 28 dicembre 1908 e da altri precedenti elencati nel R.D. 15 aprile 1909. G.U del Regno d’Italia n.95 del 22/04/1909 (in Italian)
    • (1909) Technical Guidelines and Hygienic Standards for Repairing and New Constructions of Public and Private Buildings in Areas Affected by the Earthquake
  • 24
    • 85073488858 scopus 로고    scopus 로고
    • Royal Legislative Decree n. 573 of 29/4/1915 which concerns the technical and hygienic standards for building in the areas affected by the earthquake of 13 January 1915, G.U. of the Kingdom of Italy n. 117 of 11/5/1915—Regio Decreto Legge n. 573 del 29/4/1915 Che riguarda le norme tecniche ed igieniche da osservarsi per i lavori edilizi nelle località colpite dal terremoto del 13 gennaio 1915. G.U. del Regno d’Italia n. 117 dell’11/5/1915, in Italian
    • Royal Legislative Decree n. 573 of 29/4/1915 which concerns the technical and hygienic standards for building in the areas affected by the earthquake of 13 January 1915. G.U. of the Kingdom of Italy n. 117 of 11/5/1915—Regio Decreto Legge n. 573 del 29/4/1915 Che riguarda le norme tecniche ed igieniche da osservarsi per i lavori edilizi nelle località colpite dal terremoto del 13 gennaio 1915. G.U. del Regno d’Italia n. 117 dell’11/5/1915 (in Italian)
  • 25
    • 84989914825 scopus 로고    scopus 로고
    • An experimental study on the influence of composite materials used to reinforce masonry ring beams
    • Sisti R, Corradi M, Borri A (2016) An experimental study on the influence of composite materials used to reinforce masonry ring beams. Constr Build Mater 122(2016):231–241. 10.1016/j.conbuildmat.2016.06.120
    • (2016) Constr Build Mater , vol.122 , Issue.2016 , pp. 231-241
    • Sisti, R.1    Corradi, M.2    Borri, A.3
  • 26
    • 85045954464 scopus 로고    scopus 로고
    • Seismic behaviour of ordinary masonry buildings during the 2016 Central Italy earthquakes
    • Sorrentino L, da Porto F, Magenes G, Penna A (2018) Seismic behaviour of ordinary masonry buildings during the 2016 Central Italy earthquakes. Bull Earthq Eng. 10.1007/s10518-018-0370-4
    • (2018) Bull Earthq Eng
    • Sorrentino, L.1    da Porto, F.2    Magenes, G.3    Penna, A.4
  • 27
    • 84870440092 scopus 로고
    • Report ZMRK, Institute for Testing and Research in Materials and Structures, Ljubljiana, Slovenia
    • Tomaževic M (1978) The computer program POR. Report ZMRK, Institute for Testing and Research in Materials and Structures, Ljubljiana, Slovenia
    • (1978) The Computer Program POR
    • Tomaževic, M.1
  • 28
    • 0036787062 scopus 로고    scopus 로고
    • Shear behavior of masonry panels strengthened by FRP laminates
    • Valluzzi MR, Tinazzi D, Modena C (2002) Shear behavior of masonry panels strengthened by FRP laminates. Constr Build Mater 16:409–416. 10.1016/S0950-0618(02)00043-0
    • (2002) Constr Build Mater , vol.16 , pp. 409-416
    • Valluzzi, M.R.1    Tinazzi, D.2    Modena, C.3
  • 29
    • 85035800043 scopus 로고    scopus 로고
    • Simplified survey form of unreinforced masonry buildings calibrated on data from the 2009 L’Aquila earthquake
    • Zucconi M, Ferlito R, Sorrentino L (2018) Simplified survey form of unreinforced masonry buildings calibrated on data from the 2009 L’Aquila earthquake. Bull Earthq Eng 16(7):2877–2911. 10.1007/s10518-017-0283-7
    • (2018) Bull Earthq Eng , vol.16 , Issue.7 , pp. 2877-2911
    • Zucconi, M.1    Ferlito, R.2    Sorrentino, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.