메뉴 건너뛰기




Volumn 84, Issue 1, 2018, Pages 124-125

Time to monitor cuff pressures and to start "thinking supraglottic"

Author keywords

[No Author keywords available]

Indexed keywords

ASPIRATION; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; BLOOD PRESSURE REGULATION; ENDOTRACHEAL INTUBATION; HUMAN; LETTER; MORBIDITY; SORE THROAT; ANESTHESIA; ANESTHESIOLOGY; PHARYNGITIS; PROSPECTIVE STUDY;

EID: 85040696763     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: 10.23736/S0375-9393.17.12094-8     Document Type: Letter
Times cited : (7)

References (6)
  • 1
    • 85020749472 scopus 로고    scopus 로고
    • Causes of sore throat after intubation: A prospective observational study of multiple anaesthesia variables
    • Levin PD, Chrysostomos C, Ibarra CA, Ledot S, Naito D, Weissman C, et al. Causes of sore throat after intubation: A prospective observational study of multiple anaesthesia variables. Minerva Anestesiol 2017;83:582-9.
    • (2017) Minerva Anestesiol , vol.83 , pp. 582-589
    • Levin, P.D.1    Chrysostomos, C.2    Ibarra, C.A.3    Ledot, S.4    Naito, D.5    Weissman, C.6
  • 2
    • 78149470999 scopus 로고    scopus 로고
    • Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: A multicenter study
    • L iu J, Zhang X, Gong W, Li S, Wang F, Fu S, et al. Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: A multicenter study. Anesth Analg 2010;111:1133-7.
    • (2010) Anesth Analg , vol.111 , pp. 1133-1137
    • Liu, J.1    Zhang, X.2    Gong, W.3    Li, S.4    Wang, F.5    Fu, S.6
  • 3
    • 84986271721 scopus 로고    scopus 로고
    • Digital palpation of the pilot balloon vs. Continuous manometry for controlling the intracuff pressure in laryngeal mask airways
    • Hensel M, Güldenpfennig T, Schmidt A, Krumm M, Kerner T, Kox WJ. Digital palpation of the pilot balloon vs. continuous manometry for controlling the intracuff pressure in laryngeal mask airways. Anaesthesia 2016;71:1169-76.
    • (2016) Anaesthesia , vol.71 , pp. 1169-1176
    • Hensel, M.1    Güldenpfennig, T.2    Schmidt, A.3    Krumm, M.4    Kerner, T.5    Kox, W.J.6
  • 4
    • 84857373257 scopus 로고    scopus 로고
    • The role of the endotracheal tube cuff in microaspiration
    • Hamilton VA , Grap MJ. The role of the endotracheal tube cuff in microaspiration. Heart Lung 2012;41:167-72.
    • (2012) Heart Lung , vol.41 , pp. 167-172
    • Hamilton, V.A.1    Grap, M.J.2
  • 5
    • 0041343203 scopus 로고    scopus 로고
    • Is routine endotracheal intubation as safe as we think or wish?
    • Maktabi MA, Smith RB, Todd MM. Is routine endotracheal intubation as safe as we think or wish?. Anesthesiology 2003;99:247-8.
    • (2003) Anesthesiology , vol.99 , pp. 247-248
    • Ma, M.1    Smith, R.B.2    Todd, M.M.3
  • 6
    • 85018522530 scopus 로고    scopus 로고
    • Supraglottic airway devices: The search for the best insertion technique or the time to change our point of view?
    • S orbello M, Petrini F. Supraglottic airway devices: The search for the best insertion technique or the time to change our point of view?. Turk J Anaesthesiol Reanim 2017;45:76-82.
    • (2017) Turk J Anaesthesiol Reanim , vol.45 , pp. 76-82
    • Sorbello, M.1    Petrini, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.