1
-
-
0031030467
-
Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure
-
Guyton DC, Barlow MR, Besselievre TR. Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure. Crit Care Med 1997;25:91-4
-
(1997)
Crit Care Med
, vol.25
, pp. 91-94
-
-
Guyton, D.C.1
Barlow, M.R.2
Besselievre, T.R.3
-
2
-
-
3142737545
-
Tracheal rupture complicating emergency endotracheal intubation
-
Fan CM, Ko PC, Tsai K, Chiang W, Chang Y, Chen W, Yuan A. Tracheal rupture complicating emergency endotracheal intubation. Am J Emerg Med 2004;22:289-93
-
(2004)
Am J Emerg Med
, vol.22
, pp. 289-293
-
-
Fan, C.M.1
Ko, P.C.2
Tsai, K.3
Chiang, W.4
Chang, Y.5
Chen, W.6
Yuan, A.7
-
3
-
-
0033833858
-
Obstructive fibrinous tracheal pseudomembrane: A potentially fatal complication of tracheal intubation
-
Deslee G, Brichet A, Lebuffe G, Copin MC, Ramon P, Marquette CH. Obstructive fibrinous tracheal pseudomembrane: a potentially fatal complication of tracheal intubation. Am J Respir Crit Care Med 2000;162:1169-71
-
(2000)
Am J Respir Crit Care Med
, vol.162
, pp. 1169-1171
-
-
Deslee, G.1
Brichet, A.2
Lebuffe, G.3
Copin, M.C.4
Ramon, P.5
Marquette, C.H.6
-
4
-
-
0033957774
-
Acute tracheal rupture related to endotracheal intubation: Case report
-
Harris R, Joseph A. Acute tracheal rupture related to endotracheal intubation: case report. J Emerg Med 2000;18:35-9
-
(2000)
J Emerg Med
, vol.18
, pp. 35-39
-
-
Harris, R.1
Joseph, A.2
-
5
-
-
0036210961
-
Iatrogenic rupture of the tracheobronchial tree
-
Hofmann HS, Rettig G, Radke J, Neef H, Silber RE. Iatrogenic rupture of the tracheobronchial tree. Eur J Cardiothorac Surg 2002;21:649-52
-
(2002)
Eur J Cardiothorac Surg
, vol.21
, pp. 649-652
-
-
Hofmann, H.S.1
Rettig, G.2
Radke, J.3
Neef, H.4
Silber, R.E.5
-
6
-
-
0035960145
-
The accurate measurement of endotracheal tube cuff pressures
-
Ganner C. The accurate measurement of endotracheal tube cuff pressures. Br J Nurs 2001;10:1127-34
-
(2001)
Br J Nurs
, vol.10
, pp. 1127-1134
-
-
Ganner, C.1
-
7
-
-
0025677458
-
Endotracheal tube cuff pressure assessment: Pitfalls of finger estimation and need for objective measurement
-
Fernandez R, Blanch L, Mancebo J, Bonsoms N, Artigas A. Endotracheal tube cuff pressure assessment: pitfalls of finger estimation and need for objective measurement. Crit Care Med 1990;18:1423-6
-
(1990)
Crit Care Med
, vol.18
, pp. 1423-1426
-
-
Fernandez, R.1
Blanch, L.2
Mancebo, J.3
Bonsoms, N.4
Artigas, A.5
-
8
-
-
0036491274
-
Control of the endotracheal cuff balloon pressure as a method of preventing laryngotracheal lesions in critically ill intubated patients
-
Granja C, Faraldo S, Laguna P, Gois L. Control of the endotracheal cuff balloon pressure as a method of preventing laryngotracheal lesions in critically ill intubated patients. Rev Esp Anestesiol Reanim 2002;49:137-40
-
(2002)
Rev Esp Anestesiol Reanim
, vol.49
, pp. 137-140
-
-
Granja, C.1
Faraldo, S.2
Laguna, P.3
Gois, L.4
-
9
-
-
65349150556
-
Variations in endotracheal cuff pressure in intubated critically ill patients: Prevalence and risk factors
-
Nseir S, Brisson H, Marquette CH, Chaud P, Di Pompeo C, Diarra M, Durocher A. Variations in endotracheal cuff pressure in intubated critically ill patients: prevalence and risk factors. Eur J Anaesthesiol 2009;26:229-34
-
(2009)
Eur J Anaesthesiol
, vol.26
, pp. 229-234
-
-
Nseir, S.1
Brisson, H.2
Marquette, C.H.3
Chaud, P.4
Di Pompeo, C.5
Diarra, M.6
Durocher, A.7
-
10
-
-
33144483083
-
Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques
-
Hoffman RJ, Parwani V, Hahn IH. Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques. Am J Emerg Med 2006;24:139-43
-
(2006)
Am J Emerg Med
, vol.24
, pp. 139-143
-
-
Hoffman, R.J.1
Parwani, V.2
Hahn, I.H.3
-
11
-
-
36549019479
-
Continuous control of endotracheal cuff pressure and tracheal wall damage: A randomized controlled animal study
-
Nseir S, Duguet A, Copin MC, De Jonckheere J, Zhang M, Similowski T, Marquette CH. Continuous control of endotracheal cuff pressure and tracheal wall damage: a randomized controlled animal study. Crit Care 2007;11:R109
-
(2007)
Crit Care
, vol.11
-
-
Nseir, S.1
Duguet, A.2
Copin, M.C.3
De Jonckheere, J.4
Zhang, M.5
Similowski, T.6
Marquette, C.H.7
-
12
-
-
17144451348
-
Cuff pressure in endotracheal intubation: Should it be routinely measured?
-
Curiel Garcia JA, Guerrero-Romero F, Rodriguez-Moran M. Cuff pressure in endotracheal intubation: should it be routinely measured? [in Spanish]. Gac Med Mex 2001;137:179-82
-
(2001)
Gac Med Mex
, vol.137
, pp. 179-182
-
-
Curiel Garcia, J.A.1
Guerrero-Romero, F.2
Rodriguez-Moran, M.3
-
13
-
-
0034756234
-
Intracuff pressure and tracheal morbidity: Influence of filling cuff with saline during nitrous oxide anesthesia
-
Combes X, Schauviliege F, Peyrouset O, Motamed C, Kirov K, Dhonneur G, Duvaldestin P. Intracuff pressure and tracheal morbidity: influence of filling cuff with saline during nitrous oxide anesthesia. Anesthesiology 2001;95:1120-4
-
(2001)
Anesthesiology
, vol.95
, pp. 1120-1124
-
-
Combes, X.1
Schauviliege, F.2
Peyrouset, O.3
Motamed, C.4
Kirov, K.5
Dhonneur, G.6
Duvaldestin, P.7
-
14
-
-
65549150399
-
Assessment of endotracheal cuff pressure by continuous monitoring: A pilot study
-
Sole ML, Penoyer DA, Su X, Jimenez E, Kalita SJ, Poalillo E, Byers JF, Bennett M, Ludy JE. Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study. Am J Crit Care 2009;18:133-43
-
(2009)
Am J Crit Care
, vol.18
, pp. 133-143
-
-
Sole, M.L.1
Penoyer, D.A.2
Su, X.3
Jimenez, E.4
Kalita, S.J.5
Poalillo, E.6
Byers, J.F.7
Bennett, M.8
Ludy, J.E.9
-
15
-
-
33845186646
-
Endotracheal intracuff pressures in the ED and prehospital setting: Is there a problem?
-
Svenson JE, Lindsay MB, O'Connor JE. Endotracheal intracuff pressures in the ED and prehospital setting: is there a problem? Am J Emerg Med 2007;25:53-6
-
(2007)
Am J Emerg Med
, vol.25
, pp. 53-56
-
-
Svenson, J.E.1
Lindsay, M.B.2
O'connor, J.E.3
|