메뉴 건너뛰기




Volumn 10, Issue 11, 2017, Pages

Study on quantitative correlations between the ageing condition of transformer cellulose insulation and the large time constant obtained from the extended debye model

Author keywords

Ageing effect; Large time constant; Polarization depolarization current; Quantitative correlation; Transformer cellulose insulation; Water effect

Indexed keywords

CELLULOSE; CURVE FITTING; DEPOLARIZATION; INSULATING MATERIALS; INSULATION; PAPER; PHONONS; POLARIZATION;

EID: 85036453589     PISSN: None     EISSN: 19961073     Source Type: Journal    
DOI: 10.3390/en10111842     Document Type: Article
Times cited : (28)

References (31)
  • 1
    • 79956307299 scopus 로고    scopus 로고
    • Fuzzy information granulated particle swarm optimisation-support vector machine regression for the trend forecasting of dissolved gases in oil-filled transformers
    • CrossRef
    • Liao, R.; Zheng, H.; Grzybowski, S.; Yang, L.; Tang, C; Zhang, Y. Fuzzy information granulated particle swarm optimisation-support vector machine regression for the trend forecasting of dissolved gases in oil-filled transformers. IET Electr. Power Appl. 2011, 5, 230-237. [CrossRef]
    • (2011) IET Electr. Power Appl. , vol.5 , pp. 230-237
    • Liao, R.1    Zheng, H.2    Grzybowski, S.3    Yang, L.4    Tang, C.5    Zhang, Y.6
  • 2
    • 84872123341 scopus 로고    scopus 로고
    • Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation
    • CrossRef
    • Koch, M.; Prevost, T. Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation. IEEE Trans. Dielectr. Electr. Insul. 2012, 19, 1908-1915. [CrossRef]
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , pp. 1908-1915
    • Koch, M.1    Prevost, T.2
  • 4
    • 0036880503 scopus 로고    scopus 로고
    • Review of condition assessment of power transformers in service
    • CrossRef
    • Wang, M.; Vandermaar, A.J.; Srivastava, K.D. Review of condition assessment of power transformers in service. IEEE Electr. Insul. Mag. 2002, 18, 12-15. [CrossRef]
    • (2002) IEEE Electr. Insul. Mag. , vol.18 , pp. 12-15
    • Wang, M.1    Vandermaar, A.J.2    Srivastava, K.D.3
  • 5
    • 77952030632 scopus 로고    scopus 로고
    • A comparative study of thermal aging of transformer insulation paper impregnated in natural ester and in mineral oil
    • CrossRef
    • Liao, R.; Liang, S.; Sun, C; Yang, L.; Sun, H. A comparative study of thermal aging of transformer insulation paper impregnated in natural ester and in mineral oil. Eur. Trans. Electr. Power 2010, 20, 518-533. [CrossRef]
    • (2010) Eur. Trans. Electr. Power , vol.20 , pp. 518-533
    • Liao, R.1    Liang, S.2    Sun, C.3    Yang, L.4    Sun, H.5
  • 7
    • 84946033977 scopus 로고    scopus 로고
    • Effect of loads and other key factors on oil-transformer ageing: Sustainability benefits and challenges
    • CrossRef
    • Godina, R.; Rodrigues, E.M.G.; Matias, J.C.O.; Catalão, J.P.S. Effect of loads and other key factors on oil-transformer ageing: Sustainability benefits and challenges. Energies 2015, 8, 12147-12186. [CrossRef]
    • (2015) Energies , vol.8 , pp. 12147-12186
    • Godina, R.1    Rodrigues, E.M.G.2    Matias, J.C.O.3    Catalão, J.P.S.4
  • 8
    • 84907389815 scopus 로고    scopus 로고
    • Induced voltages ratio-based algorithm for fault detection, and faulted phase and winding identification of a three-winding power transformer
    • CrossRef
    • Lee, B.E.; Park, J.W.; Crossley, P.A.; Kang, YC. Induced voltages ratio-based algorithm for fault detection, and faulted phase and winding identification of a three-winding power transformer. Energies 2014, 7, 6031-6049. [CrossRef]
    • (2014) Energies , vol.7 , pp. 6031-6049
    • Lee, B.E.1    Park, J.W.2    Crossley, P.A.3    Kang, Y.C.4
  • 9
    • 84956627431 scopus 로고    scopus 로고
    • Reliability analysis and overload capability assessment of oil-immersed power transformers
    • CrossRef
    • Wang, C; Wu, J.; Wang, J.; Zhao, W Reliability analysis and overload capability assessment of oil-immersed power transformers. Energies 2016, 9, 43. [CrossRef]
    • (2016) Energies , vol.9 , pp. 43
    • Wang, C.1    Wu, J.2    Wang, J.3    Zhao, W.4
  • 10
    • 85033237269 scopus 로고    scopus 로고
    • Transformer paper expected life estimation using ANFIS based on oil characteristics and dissolved gases (case study: Indonesian transformers)
    • CrossRef
    • Prasojo, A.; Diwyacitta, K.; Gumilang, H. Transformer paper expected life estimation using ANFIS based on oil characteristics and dissolved gases (case study: Indonesian transformers). Energies 2017, 10, 1135. [CrossRef]
    • (2017) Energies , vol.10 , pp. 1135
    • Prasojo, A.1    Diwyacitta, K.2    Gumilang, H.3
  • 11
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    • CrossRef
    • Saha, T.K. Review of modern diagnostic techniques for assessing insulation condition in aged transformers. IEEE Trans. Dielectr. Electr. Insul. 2003, 10, 903-917. [CrossRef]
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , pp. 903-917
    • Saha, T.K.1
  • 12
    • 33847704075 scopus 로고    scopus 로고
    • Dielectric response of mineral oil impregnated cellulose and the impact of aging
    • CrossRef
    • Linhjell, D.; Lundgaard, L.E.; Gafvert, U. Dielectric response of mineral oil impregnated cellulose and the impact of aging. IEEE Trans. Dielectr. Electr. Insul. 2007, 14, 156-169. [CrossRef]
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , pp. 156-169
    • Linhjell, D.1    Lundgaard, L.E.2    Gafvert, U.3
  • 13
    • 84862649874 scopus 로고    scopus 로고
    • Quantitative analysis of ageing condition of oil-paper insulation by frequency domain spectroscopy
    • CrossRef
    • Liao, R.; Hao, J.; Chen, G.; Yang, L. Quantitative analysis of ageing condition of oil-Paper insulation by frequency domain spectroscopy. IEEE Trans. Dielectr. Electr. Insul. 2012, 19, 821-830. [CrossRef]
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , pp. 821-830
    • Liao, R.1    Hao, J.2    Chen, G.3    Yang, L.4
  • 14
    • 37749022981 scopus 로고    scopus 로고
    • Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system
    • CrossRef
    • Saha, T.K.; Purkait, P. Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system. IEEE Trans. Power Deliv. 2008, 23, 252-260. [CrossRef]
    • (2008) IEEE Trans. Power Deliv. , vol.23 , pp. 252-260
    • Saha, T.K.1    Purkait, P.2
  • 15
    • 0037250619 scopus 로고    scopus 로고
    • Experience with return voltage measurements for assessing insulation conditions in service-aged transformers
    • CrossRef
    • Saha, T.K.; Zheng, T.Y. Experience with return voltage measurements for assessing insulation conditions in service-aged transformers. IEEE Trans. Power Deliv. 2003, 18, 128-135. [CrossRef]
    • (2003) IEEE Trans. Power Deliv. , vol.18 , pp. 128-135
    • Saha, T.K.1    Zheng, T.Y.2
  • 16
    • 84862917368 scopus 로고    scopus 로고
    • Novel characteristic parameters for oil-paper insulation assessment from differential time-domain spectroscopy based on polarization and depolarization current measurement
    • CrossRef
    • We, J.; Zhang, G.; Xu, H.; Peng, H.; Wang, S.; Dong, M. Novel characteristic parameters for oil-paper insulation assessment from differential time-domain spectroscopy based on polarization and depolarization current measurement. IEEE Trans. Dielectr. Electr. Insul. 2011, 18, 1918-1928. [CrossRef]
    • (2011) IEEE Trans. Dielectr. Electr. Insul. , vol.18 , pp. 1918-1928
    • We, J.1    Zhang, G.2    Xu, H.3    Peng, H.4    Wang, S.5    Dong, M.6
  • 17
    • 1842529229 scopus 로고    scopus 로고
    • Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers
    • CrossRef
    • Saha, T.K.; Purkait, P. Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers. IEEE Trans. Dielectr. Electr. Insul. 2004, 11, 144-154. [CrossRef]
    • (2004) IEEE Trans. Dielectr. Electr. Insul. , vol.11 , pp. 144-154
    • Saha, T.K.1    Purkait, P.2
  • 18
    • 0242720703 scopus 로고    scopus 로고
    • Dielectric spectroscopy in time and frequency domain for HV power equipment, Part I: Theoretical considerations
    • CrossRef
    • Zaengl, W.S. Dielectric spectroscopy in time and frequency domain for HV power equipment, Part I: Theoretical considerations. IEEE Electr. Insul. Mag. 2003, 19, 9-22. [CrossRef]
    • (2003) IEEE Electr. Insul. Mag. , vol.19 , pp. 9-22
    • Zaengl, W.S.1
  • 19
    • 84924495875 scopus 로고    scopus 로고
    • Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of water content in paper-oil insulation system
    • CrossRef
    • Liao, R.; Liu, J.; Yang, L.; Gao, J.; Zhang, Y; Lv, Y; Zheng, H. Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of water content in paper-oil insulation system. IET Electr. Power Appl. 2015, 9, 213-222. [CrossRef]
    • (2015) IET Electr. Power Appl. , vol.9 , pp. 213-222
    • Liao, R.1    Liu, J.2    Yang, L.3    Gao, J.4    Zhang, Y.5    Lv, Y.6    Zheng, H.7
  • 20
    • 85015291576 scopus 로고    scopus 로고
    • Modelling the low-frequency dielectric response test of insulation oil
    • CrossRef
    • Wang, D.; Zhou, L.; Chen, X.; Jiang, J.; Wang, L. Modelling the low-frequency dielectric response test of insulation oil. IET Electr. Power Appl. 2017, 11, 323-330. [CrossRef]
    • (2017) IET Electr. Power Appl. , vol.11 , pp. 323-330
    • Wang, D.1    Zhou, L.2    Chen, X.3    Jiang, J.4    Wang, L.5
  • 21
    • 33646398368 scopus 로고    scopus 로고
    • Dielectric response studies on insulating system of high voltage rotating machines
    • CrossRef
    • Farahani, M.; Borsi, H.; Gockenbach, E. Dielectric response studies on insulating system of high voltage rotating machines. IEEE Trans. Dielectr. Electr. Insul. 2006, 13, 383-393. [CrossRef]
    • (2006) IEEE Trans. Dielectr. Electr. Insul. , vol.13 , pp. 383-393
    • Farahani, M.1    Borsi, H.2    Gockenbach, E.3
  • 22
    • 84877315999 scopus 로고    scopus 로고
    • On the feasibility of using poles computed from frequency domain spectroscopy to assess oil impregnated paper insulation conditions
    • CrossRef
    • Hadjadj, Y; Meghnefi, F.; Fofana, I.; Ezzaidi, H. On the feasibility of using poles computed from frequency domain spectroscopy to assess oil impregnated paper insulation conditions. Energies 2013, 6, 2204-2220. [CrossRef]
    • (2013) Energies , vol.6 , pp. 2204-2220
    • Hadjadj, Y.1    Meghnefi, F.2    Fofana, I.3    Ezzaidi, H.4
  • 24
    • 84887093015 scopus 로고    scopus 로고
    • Assessment of non-uniform aging of cellulose dielectric using system poles of a modified extended debye model for oil-paper insulation of transformers
    • CrossRef
    • Baral, A.; Chakravorti, S. Assessment of non-uniform aging of cellulose dielectric using system Poles of a modified extended Debye model for oil-paper insulation of transformers. IEEE Trans. Dielectr. Electr. Insul. 2013, 20, 1922-1933. [CrossRef]
    • (2013) IEEE Trans. Dielectr. Electr. Insul. , vol.20 , pp. 1922-1933
    • Baral, A.1    Chakravorti, S.2
  • 25
    • 84903147097 scopus 로고    scopus 로고
    • Prediction of water present in cellulosic part of power transformer insulation using transfer function of modified extended debye model
    • CrossRef
    • Baral, A.; Chakravorti, S. Prediction of water present in cellulosic part of power transformer insulation using transfer function of modified extended Debye model. IEEE Trans. Dielectr. Electr. Insul. 2014, 21, 1368-1375. [CrossRef]
    • (2014) IEEE Trans. Dielectr. Electr. Insul. , vol.21 , pp. 1368-1375
    • Baral, A.1    Chakravorti, S.2
  • 26
    • 84863178401 scopus 로고    scopus 로고
    • Quantitative analysis ageing condition of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current
    • Hao, J.; Liao, R.; Chen, G.; Ma, Z.; Yang, L. Quantitative analysis ageing condition of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current. IEEE Trans. Dielectr. Electr. Insul. 2012, 19, 188-199.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , pp. 188-199
    • Hao, J.1    Liao, R.2    Chen, G.3    Ma, Z.4    Yang, L.5
  • 27
    • 85036475470 scopus 로고    scopus 로고
    • Grey relational analysis for insulation condition assessment of power transformers based upon conventional dielectric response measurement
    • CrossRef
    • Liu, J.; Zheng, H.; Zhang, Y.; Wei, H.; Liao, R. Grey relational analysis for insulation condition assessment of power transformers based upon conventional dielectric response measurement. Energies 2017, 10, 1526. [CrossRef]
    • (2017) Energies , vol.10 , pp. 1526
    • Liu, J.1    Zheng, H.2    Zhang, Y.3    Wei, H.4    Liao, R.5
  • 29
    • 12544251886 scopus 로고    scopus 로고
    • Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements
    • CrossRef
    • Saha, T.K.; Purkait, P.; Müller, F. Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements. IEEE Trans. Power Deliv. 2005, 20, 149-157. [CrossRef]
    • (2005) IEEE Trans. Power Deliv. , vol.20 , pp. 149-157
    • Saha, T.K.1    Purkait, P.2    Müller, F.3
  • 30
    • 84927732936 scopus 로고    scopus 로고
    • Condition evaluation for aging state of transformer oil-paper insulation based on time-frequency domain dielectric characteristics
    • CrossRef
    • Liu, J.; Liao, R.; Zhang, Y.; Gong, C.; Wang, C.; Gao, J. Condition evaluation for aging state of transformer oil-paper insulation based on time-frequency domain dielectric characteristics. Electr. Power Compon. Syst. 2015, 43, 759-769. [CrossRef]
    • (2015) Electr. Power Compon. Syst. , vol.43 , pp. 759-769
    • Liu, J.1    Liao, R.2    Zhang, Y.3    Gong, C.4    Wang, C.5    Gao, J.6
  • 31
    • 70449112672 scopus 로고    scopus 로고
    • Low temperature and water effects on polarization and depolarization currents of oil-paper insulation
    • CrossRef
    • Fofana, I.; Hemmatjoua, H.; Farzaneh, M. Low temperature and water effects on polarization and depolarization currents of oil-paper insulation. Electr. Power Compon. Syst. 2010, 80, 91-97. [CrossRef]
    • (2010) Electr. Power Compon. Syst. , vol.80 , pp. 91-97
    • Fofana, I.1    Hemmatjoua, H.2    Farzaneh, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.