Volumn 19, Issue 6, 2012, Pages 1908-1915

Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation

Author keywords

Aging; Conduction; Dielectric Frequency Response; Dielectric Response; Insulation; Moisture; Oil Conductivity; Polarization; Power Factor; Water Content

Indexed keywords

CONDITION ASSESSMENTS; DIELECTRIC FREQUENCY RESPONSE; DIELECTRIC RESPONSE; DIELECTRIC RESPONSE MEASUREMENTS; ESTIMATION OF PROPERTIES; FREQUENCY RANGES; INSULATION MATERIALS; OIL CONDUCTIVITY; OIL-PAPER INSULATION SYSTEM; OIL-PAPERS; POWER FACTORS; PROPER MODELING; SOLID INSULATION; TEST METHOD; TRANSFORMER INSULATION; WIDE FREQUENCY RANGE;

EID: 84872123341     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2012.6396947     Document Type: Article
Times cited : (130)

References (11)
  • 4
    • 51849112512 scopus 로고    scopus 로고
    • A fast and reliable dielectric diagnostic method to determine moisture in power transformers
    • Paper E1-2, Beijing, China
    • M. Koch and M. Krüger, "A fast and reliable dielectric diagnostic method to determine moisture in power transformers", IEEE Int'l. Conf. Condition Monitoring and Diagnosis (CMD), paper E1-2, Beijing, China, 2008
    • (2008) IEEE int'L. Conf. Condition Monitoring and Diagnosis (CMD)
    • Koch, M.1    Krüger, M.2
  • 7
    • 33847691642 scopus 로고    scopus 로고
    • Ph.D. degree thesis, Dep. of Materials and Manufacturing Technology, Chalmers University of Technology, Gothenburg, 2006
    • C. Ekanayake, "Diagnosis of Moisture in Transformer Insulation, Ph.D. degree thesis, Dep. of Materials and Manufacturing Technology, Chalmers University of Technology, Gothenburg, 2006.
    • Diagnosis of Moisture in Transformer Insulation
    • Ekanayake, C.1
  • 8
    • 77950187671 scopus 로고    scopus 로고
    • Ageing performance and moisture solubility of vegetable oils for power transformers
    • S. Tenbohlen and M. Koch, "Ageing performance and moisture solubility of vegetable oils for power transformers", IEEE Trans. Power Delivery, Vol. 25, pp. 825-830, 2010.
    • (2010) IEEE Trans. Power Delivery , vol.25 , pp. 825-830
    • Tenbohlen, S.1    Koch, M.2
  • 9
    • 84887057950 scopus 로고    scopus 로고
    • The negative dissipation factor and the interpretation of the dielectric response of power transformers
    • ISH, Paper A-2, Cape Town
    • M. Koch and M. Krueger, "The negative dissipation factor and the interpretation of the dielectric response of power transformers", Int'l. Sympos. High Voltage Engineering, ISH, Paper A-2, Cape Town, 2009.
    • (2009) Int'L. Sympos. High Voltage Engineering
    • Koch, M.1    Krueger, M.2
  • 10
    • 77957360758 scopus 로고    scopus 로고
    • Information within the dielectric response of power transformers for wide frequency ranges
    • San Diego, CA, USA
    • M. Jaya, T. Leibfried, and M. Koch, "Information within the dielectric response of power transformers for wide frequency ranges", IEEE Int'l. Sympos. Electr. Insul. (ISEI), San Diego, CA, USA, pp. 1-5, 2010.
    • (2010) IEEE int'L. Sympos. Electr. Insul. (ISEI) , pp. 1-5
    • Jaya, M.1    Leibfried, T.2    Koch, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.