메뉴 건너뛰기




Volumn 17, Issue 3, 2010, Pages 799-807

On the frequency domain dielectric response of oil-paper insulation at low temperatures

Author keywords

Conductivity; Dielectric spectroscopy; Frequency domain; Low temperatures; Moisture content; Oil paper insulation; Poles

Indexed keywords

FREQUENCY DOMAINS; LOW TEMPERATURES; MOISTURE CONTENT; MOISTURE CONTENTS; OIL PAPER INSULATION;

EID: 77954188676     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5492253     Document Type: Article
Times cited : (147)

References (21)
  • 1
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    • T. K. Saha, "Review of Modern Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers", IEEE Trans. Dielectr. Electr. Insul. Vol.10, pp. 903-917, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul , vol.10 , pp. 903-917
    • Saha, T.K.1
  • 3
    • 70449668091 scopus 로고    scopus 로고
    • Application of petroleum-based oil in power transformer
    • Eds.: N. David and T. Michel, Nova Science Publishers, Inc., ISBN: 978-1- 60456-700-707
    • I. Fofana and J. Sabau, "Application of Petroleum-based oil in Power Transformer", 23 pages, In Natural Gas Research Progress, Eds.: N. David and T. Michel, Nova Science Publishers, Inc., ISBN: 978-1- 60456-700-707, 2008.
    • (2008) Natural Gas Research Progress , pp. 23
    • Fofana, I.1    Sabau, J.2
  • 4
    • 33847155852 scopus 로고    scopus 로고
    • Application of modern techniques for the condition assessment of power transformers
    • Presented at, Paris, France
    • M. de Nigris, R. Passaglia, R. Berti, L. Bergonzi and R. Maggi, "Application of modern techniques for the condition assessment of power transformers", Presented at the CIGRE Session 2004, Paper A2- 207, Paris, France, 2004.
    • (2004) The CIGRE Session 2004
    • De Nigris, M.1    Passaglia, R.2    Berti, R.3    Bergonzi, L.4    Maggi, R.5
  • 5
    • 0242720703 scopus 로고    scopus 로고
    • Dielectric spectroscopy in time and frequency domain for HV Power equipment, Part I: Theoretical considerations
    • W.S. Zaengl, "Dielectric Spectroscopy in Time and Frequency Domain for HV Power Equipment, Part I: Theoretical Considerations", IEEE Electr. Insul. Mag., Vol.19, No.5, pp. 5-19, 2003.
    • (2003) IEEE Electr. Insul. Mag. , vol.19 , Issue.5 , pp. 5-19
    • Zaengl, W.S.1
  • 6
    • 1242330865 scopus 로고    scopus 로고
    • Application of dielectric spectroscopy in time and frequency domain for HV power equipment
    • W.S. Zaengl, "Application of Dielectric Spectroscopy in Time and Frequency Domain for HV Power Equipment", IEEE Electr. Insul. Mag., Vol.19, No.6, pp. 9-22, 2003.
    • (2003) IEEE Electr. Insul. Mag. , vol.19 , Issue.6 , pp. 9-22
    • Zaengl, W.S.1
  • 7
    • 0141996608 scopus 로고    scopus 로고
    • Dielectric response methods for diagnostics of power transformers
    • Cigre Task Force 15.01.09
    • Cigre Task Force 15.01.09: "Dielectric Response Methods for Diagnostics of Power Transformers", Electra, No.202, pp. 25-36, 2002.
    • (2002) Electra , Issue.202 , pp. 25-36
  • 8
    • 49449107140 scopus 로고    scopus 로고
    • Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions
    • A. Seytashmehr, I. Fofana, C. Eichler, A. Akbari, H. Borsi and E. Gockenbach, "Dielectric Spectroscopic Measurements on Transformer Oil-Paper Insulation under Controlled Laboratory Conditions", IEEE Trans. Dielectr. Electr. Insul., Vol.15, pp. 1100-1111, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , pp. 1100-1111
    • Seytashmehr, A.1    Fofana, I.2    Eichler, C.3    Akbari, A.4    Borsi, H.5    Gockenbach, E.6
  • 9
    • 77954200893 scopus 로고    scopus 로고
    • Insulation Diagnostics Spectrometer IDA, Eldarv. 4, SE-187 75 Täby, Sweden
    • Insulation Diagnostics Spectrometer IDA, Programma Electric AB, Eldarv. 4, SE-187 75 Täby, Sweden.
    • Programma Electric AB
  • 10
    • 77954182027 scopus 로고    scopus 로고
    • available at:
    • Weidmann, Electrical Technology, "Diamond Pattern Paper datasheet", available at: www.weidmann-electrical.com, 2008.
    • (2008) Diamond Pattern Paper Datasheet
  • 12
    • 79953655525 scopus 로고    scopus 로고
    • The latest on-site non-destructive technique for insulation analysis of electrical power apparatus
    • Presented at, Sacramento, USA
    • A.B. Supatra, "The Latest On-Site Non-Destructive Technique for Insulation Analysis of Electrical Power Apparatus", Presented at the 2004 Weidmann-ACTI Annual Technical Conference, Sacramento, USA, 2004.
    • (2004) The 2004 Weidmann-ACTI Annual Technical Conference
    • Supatra, A.B.1
  • 13
    • 37749022981 scopus 로고    scopus 로고
    • Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system
    • T. K. Saha and P. Purkait, "Investigations of Temperature Effects on the Dielectric Response Measurements of Transformer Oil-Paper Insulation System", IEEE Trans. Power Delivery, Vol.23, pp. 252-260, 2008.
    • (2008) IEEE Trans. Power Delivery , vol.23 , pp. 252-260
    • Saha, T.K.1    Purkait, P.2
  • 14
    • 12544251886 scopus 로고    scopus 로고
    • Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements
    • T. K. Saha P. Purkait and F. Müller, "Deriving an Equivalent Circuit of Transformers Insulation for Understanding the Dielectric Response Measurements", IEEE Trans. Power Delivery, Vol.20, pp. 149-157, 2006.
    • (2006) IEEE Trans. Power Delivery , vol.20 , pp. 149-157
    • Saha, T.K.1    Purkait, P.2    Müller, F.3
  • 15
    • 1842550651 scopus 로고    scopus 로고
    • Dielectric diagnosis of water content in transformer insulation systems
    • A. Küchler and T. Bedel, "Dielectric diagnosis of water content in transformer insulation systems", European. Trans. Electr. Power, Vol.11, No.1, pp. 65-68, 2001.
    • (2001) European. Trans. Electr. Power , vol.11 , Issue.1 , pp. 65-68
    • Küchler, A.1    Bedel, T.2
  • 16
    • 0029717938 scopus 로고    scopus 로고
    • Time domain measurements of dielectric response in oil-paper insulation systems
    • Montreal, Qc, Canada
    • V. der Houhanessian and W. S. Zaengl, "Time domain measurements of dielectric response in oil-paper insulation systems", IEEE Intern. Sympos. Electr. Insul. (ISEI), Montreal, Qc, Canada, pp. 47-52, 1996.
    • (1996) IEEE Intern. Sympos. Electr. Insul. (ISEI) , pp. 47-52
    • Der Houhanessian, V.1    Zaengl, W.S.2
  • 18
    • 12544259182 scopus 로고    scopus 로고
    • Modeling of dielectric measurements on power transforms
    • Paris, France, Paper No. 15/103
    • U. Gafvert, G. Frimpong, and J. Fuhr, "Modeling of dielectric measurements on power transforms", CIGRE, Paris, France, Paper No. 15/103, 1998.
    • (1998) CIGRE
    • Gafvert, U.1    Frimpong, G.2    Fuhr, J.3
  • 21
    • 0032251894 scopus 로고    scopus 로고
    • Convergence properties of the nelder-mead simplex method in low dimensions
    • J.C. Lagarias, J. A. Reeds, M. H. Wright, and P. E. Wright, "Convergence Properties of the Nelder-Mead Simplex Method in Low Dimensions," SIAM J. Optimization, Vol.9, pp. 112-147, 1998.
    • (1998) SIAM J. Optimization , vol.9 , pp. 112-147
    • Lagarias, J.C.1    Reeds, J.A.2    Wright, M.H.3    Wright, P.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.