메뉴 건너뛰기




Volumn 11, Issue 5, 2017, Pages 1036-1044

Consensus Statement on Inpatient Use of Continuous Glucose Monitoring

Author keywords

continuous glucose monitor; diabetes; glucose; hospital; hypoglycemia; inpatient

Indexed keywords

PARACETAMOL;

EID: 85028656362     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296817706151     Document Type: Article
Times cited : (99)

References (44)
  • 1
    • 85012969799 scopus 로고    scopus 로고
    • Round table discussion on inpatient use of continuous glucose monitoring at the international hospital diabetes meeting
    • PRIDE Investigators. doi: 10.1177/1932296816656380
    • Wallia A, Umpierrez GE, Nasraway SA, Klonoff DC, PRIDE Investigators. round table discussion on inpatient use of continuous glucose monitoring at the international hospital diabetes meeting. J Diabetes Sci Technol. 2016; 10 (5): 1174-1181. doi: 10.1177/1932296816656380.
    • (2016) J Diabetes Sci Technol , vol.10 , Issue.5 , pp. 1174-1181
    • Wallia, A.1    Umpierrez, G.E.2    Nasraway, S.A.3    Klonoff, D.C.4
  • 3
    • 84655163194 scopus 로고    scopus 로고
    • Continuous measurement of glucose: Facts and challenges
    • Rice MJ, Coursin DB., Continuous measurement of glucose: facts and challenges. Anesthesiology. 2012; 116 (1): 199-204.
    • (2012) Anesthesiology , vol.116 , Issue.1 , pp. 199-204
    • Rice, M.J.1    Coursin, D.B.2
  • 4
    • 84962521367 scopus 로고    scopus 로고
    • Continuous glucose monitoring in patients undergoing extracorporeal ventricular assist therapy
    • Gottschalk A, Welp HA, Leser L, Lanckohr C, Wempe C, Ellger B., Continuous glucose monitoring in patients undergoing extracorporeal ventricular assist therapy. PLOS ONE. 2016; 11 (3): e0148778.
    • (2016) PLOS ONE , vol.11 , Issue.3 , pp. e0148778
    • Gottschalk, A.1    Welp, H.A.2    Leser, L.3    Lanckohr, C.4    Wempe, C.5    Ellger, B.6
  • 5
    • 85009448130 scopus 로고    scopus 로고
    • Glucose control in the ICU: A continuing story
    • Preiser JC, Chase JG, Hovorka R, et al. Glucose control in the ICU: a continuing story. J Diabetes Sci Technol. 2016; 10 (6): 1372-1381.
    • (2016) J Diabetes Sci Technol , vol.10 , Issue.6 , pp. 1372-1381
    • Preiser, J.C.1    Chase, J.G.2    Hovorka, R.3
  • 6
    • 85010008105 scopus 로고    scopus 로고
    • The clinical benefits and accuracy of continuous glucose monitoring systems in critically Ill patients - A systematic scoping review
    • van Steen SC, Rijkenberg S, Limpens J, et al. The clinical benefits and accuracy of continuous glucose monitoring systems in critically Ill patients-a systematic scoping review. Sensors (Basel). 2017; 17 (1).
    • (2017) Sensors (Basel) , vol.17 , Issue.1
    • Van Steen, S.C.1    Rijkenberg, S.2    Limpens, J.3
  • 7
    • 33746595198 scopus 로고    scopus 로고
    • Intensive insulin therapy in the intensive care unit: Assessment by continuous glucose monitoring
    • De Block C, Manuel-Y-Keenoy B, Van Gaal L, Rogiers P,. Intensive insulin therapy in the intensive care unit: assessment by continuous glucose monitoring. Diabetes Care. 2006; 29 (8): 1750-1756.
    • (2006) Diabetes Care , vol.29 , Issue.8 , pp. 1750-1756
    • De Block, C.1    Manuel-Y-Keenoy, B.2    Van Gaal, L.3    Rogiers, P.4
  • 8
    • 67650838755 scopus 로고    scopus 로고
    • Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    • Holzinger U, Warszawska J, Kitzberger R, Herkner H, Metnitz PG, Madl C., Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring. Intensive Care Med. 2009; 35 (8): 1383-1389. doi: 10.1007/s00134-009-1471-y.
    • (2009) Intensive Care Med , vol.35 , Issue.8 , pp. 1383-1389
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3    Herkner, H.4    Metnitz, P.G.5    Madl, C.6
  • 9
    • 77953062418 scopus 로고    scopus 로고
    • Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units
    • Rabiee A, Andreasik V, Abu-Hamdah R, et al. Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units. Diabetes Sci Technol. 2009; 3 (4): 951-959.
    • (2009) Diabetes Sci Technol , vol.3 , Issue.4 , pp. 951-959
    • Rabiee, A.1    Andreasik, V.2    Abu-Hamdah, R.3
  • 10
    • 77649259538 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring in critically ill patients: A prospective randomized trial
    • Holzinger U, Warszawska J, Kitzberger R, et al. Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial. Diabetes Care. 2010; 33 (3): 467-472.
    • (2010) Diabetes Care , vol.33 , Issue.3 , pp. 467-472
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3
  • 11
    • 84874850149 scopus 로고    scopus 로고
    • The use of continuous glucose monitoring combined with computer-based eMPC algorithm for tight glucose control in cardiosurgical ICU
    • Kopecky P, Mraz M, Blaha J, et al. The use of continuous glucose monitoring combined with computer-based eMPC algorithm for tight glucose control in cardiosurgical ICU. Biomed Res Int. 2013; 2013: 186439.
    • (2013) Biomed Res Int , vol.2013 , pp. 186439
    • Kopecky, P.1    Mraz, M.2    Blaha, J.3
  • 12
    • 84907016433 scopus 로고    scopus 로고
    • Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: A randomized controlled trial
    • Boom DT, Sechterberger MK, Rijkenberg S, et al. Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial. Crit Care. 2014; 18 (4): 453.
    • (2014) Crit Care , vol.18 , Issue.4 , pp. 453
    • Boom, D.T.1    Sechterberger, M.K.2    Rijkenberg, S.3
  • 13
    • 84947930389 scopus 로고    scopus 로고
    • Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit
    • Kosiborod M, Gottlieb RK, Sekella JA, et al. Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit. BMJ Open Diabetes Res Care. 2014; 2 (1): e000037.
    • (2014) BMJ Open Diabetes Res Care , vol.2 , Issue.1 , pp. e000037
    • Kosiborod, M.1    Gottlieb, R.K.2    Sekella, J.A.3
  • 14
    • 84892653845 scopus 로고    scopus 로고
    • Accuracy of subcutaneous continuous glucose monitoring in critically ill adults: Improved sensor performance with enhanced calibrations
    • Leelarathna L, English SW, Thabit H, et al. Accuracy of subcutaneous continuous glucose monitoring in critically ill adults: improved sensor performance with enhanced calibrations. Diabetes Technol Ther. 2014; 16 (2): 97-101.
    • (2014) Diabetes Technol Ther , vol.16 , Issue.2 , pp. 97-101
    • Leelarathna, L.1    English, S.W.2    Thabit, H.3
  • 16
    • 84906043660 scopus 로고    scopus 로고
    • Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device
    • Umbrello M, Salice V, Spanu P, et al. Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device. Clin Nutr. 2014; 33 (5): 867-871. doi: 10.1016/j.clnu.2013.10.007.
    • (2014) Clin Nutr , vol.33 , Issue.5 , pp. 867-871
    • Umbrello, M.1    Salice, V.2    Spanu, P.3
  • 17
    • 84947938892 scopus 로고    scopus 로고
    • Accuracy of intra-arterial and subcutaneous continuous glucose monitoring in postoperative cardiac surgery patients in the ICU
    • Sechterberger MK, van der Voort PH, Strasma PJ, DeVries JH., Accuracy of intra-arterial and subcutaneous continuous glucose monitoring in postoperative cardiac surgery patients in the ICU. J Diabetes Sci Technol. 2015; 9 (3): 663-667.
    • (2015) J Diabetes Sci Technol , vol.9 , Issue.3 , pp. 663-667
    • Sechterberger, M.K.1    Van Der Voort, P.H.2    Strasma, P.J.3    DeVries, J.H.4
  • 18
    • 84978532532 scopus 로고    scopus 로고
    • Results of a near continuous glucose monitoring technology in surgical intensive care and trauma
    • Nohra E, Buckman S, Bochicchio K, et al. Results of a near continuous glucose monitoring technology in surgical intensive care and trauma. Contemp Clin Trials. 2016; 50: 1-4. doi: 10.1016/j.cct.2016.07.007.
    • (2016) Contemp Clin Trials , vol.50 , pp. 1-4
    • Nohra, E.1    Buckman, S.2    Bochicchio, K.3
  • 19
    • 84978971634 scopus 로고    scopus 로고
    • Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: A prospective clinical trial
    • Wollersheim T, Engelhardt LJ, Pachulla J, et al. Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial. Ann Intensive Care. 2016; 6 (1): 70.
    • (2016) Ann Intensive Care , vol.6 , Issue.1 , pp. 70
    • Wollersheim, T.1    Engelhardt, L.J.2    Pachulla, J.3
  • 20
    • 85009250142 scopus 로고    scopus 로고
    • Accuracy of 2 different continuous glucose monitoring systems in patients undergoing cardiac surgery
    • Schierenbeck F, Franco-Cereceda A, Liska J., Accuracy of 2 different continuous glucose monitoring systems in patients undergoing cardiac surgery. J Diabetes Sci Technol. 2017; 11 (1): 108-116.
    • (2017) J Diabetes Sci Technol , vol.11 , Issue.1 , pp. 108-116
    • Schierenbeck, F.1    Franco-Cereceda, A.2    Liska, J.3
  • 21
    • 77957297901 scopus 로고    scopus 로고
    • Continuous glucose monitors prove highly accurate in critically ill children
    • Bridges BC, Preissig CM, Maher KO, Rigby MR., Continuous glucose monitors prove highly accurate in critically ill children. Crit Care. 2010; 14 (5): R176.
    • (2010) Crit Care , vol.14 , Issue.5 , pp. R176
    • Bridges, B.C.1    Preissig, C.M.2    Maher, K.O.3    Rigby, M.R.4
  • 22
    • 84948661975 scopus 로고    scopus 로고
    • Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study
    • Prabhudesai S, Kanjani A, Bhagat I, Ravikumar KG, Ramachandran B., Accuracy of a real-time continuous glucose monitoring system in children with septic shock: a pilot study. Indian J Crit Care Med. 2015; 19 (11): 642-647.
    • (2015) Indian J Crit Care Med , vol.19 , Issue.11 , pp. 642-647
    • Prabhudesai, S.1    Kanjani, A.2    Bhagat, I.3    Ravikumar, K.G.4    Ramachandran, B.5
  • 23
    • 54749134550 scopus 로고    scopus 로고
    • Continuous glucose sensors: Continuing questions about clinical accuracy
    • Clarke WL, Kovatchev B., Continuous glucose sensors: continuing questions about clinical accuracy. J Diabetes Sci Technol. 2007; 1 (5): 669-675.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.5 , pp. 669-675
    • Clarke, W.L.1    Kovatchev, B.2
  • 24
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • Dungan K, Chapman J, Braithwaite SS, Buse J., Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care. 2007; 30 (2): 403-409.
    • (2007) Diabetes Care , vol.30 , Issue.2 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3    Buse, J.4
  • 25
    • 85009509196 scopus 로고    scopus 로고
    • Cybersecurity standard for connected diabetes devices
    • Klonoff DC., Cybersecurity standard for connected diabetes devices. J Diabetes Sci Technol. 2016; 3 (10): 623-626.
    • (2016) J Diabetes Sci Technol , vol.3 , Issue.10 , pp. 623-626
    • Klonoff, D.C.1
  • 26
    • 63849229179 scopus 로고    scopus 로고
    • The NICE-SUGAR (Normoglycaemia in Intensive Care Evaluation and Survival Using Glucose Algorithm Regulation) study: Statistical analysis plan
    • Committee NSM, Committee SSE
    • Finfer S, Heritier S, Committee NSM, Committee SSE. The NICE-SUGAR (Normoglycaemia in Intensive Care Evaluation and Survival Using Glucose Algorithm Regulation) study: statistical analysis plan. Crit Care Resusc. 2009; 11 (1): 46-57.
    • (2009) Crit Care Resusc , vol.11 , Issue.1 , pp. 46-57
    • Finfer, S.1    Heritier, S.2
  • 27
    • 84855512361 scopus 로고    scopus 로고
    • Management of hyperglycemia in hospitalized patients in non-critical care setting: An endocrine society clinical practice guideline
    • Umpierrez GE, Hellman R, Korytkowski MT, et al. Management of hyperglycemia in hospitalized patients in non-critical care setting: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2012; 97 (1): 16-38.
    • (2012) J Clin Endocrinol Metab , vol.97 , Issue.1 , pp. 16-38
    • Umpierrez, G.E.1    Hellman, R.2    Korytkowski, M.T.3
  • 28
    • 75549091263 scopus 로고    scopus 로고
    • Statement by an American Association of Clinical Endocrinologists/American College of Endocrinology consensus panel on type 2 diabetes mellitus: An algorithm for glycemic control
    • Rodbard HW, Jellinger PS, Davidson JA, et al. Statement by an American Association of Clinical Endocrinologists/American College of Endocrinology consensus panel on type 2 diabetes mellitus: an algorithm for glycemic control. Endocr Pract. 2009; 15 (6): 540-559.
    • (2009) Endocr Pract , vol.15 , Issue.6 , pp. 540-559
    • Rodbard, H.W.1    Jellinger, P.S.2    Davidson, J.A.3
  • 29
    • 84870225739 scopus 로고    scopus 로고
    • Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients
    • Jacobi J, Bircher N, Krinsley J, et al. Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients. Crit Care Med. 2012; 40 (12): 3251-3276.
    • (2012) Crit Care Med , vol.40 , Issue.12 , pp. 3251-3276
    • Jacobi, J.1    Bircher, N.2    Krinsley, J.3
  • 30
    • 0035829852 scopus 로고    scopus 로고
    • Intensive insulin therapy in critically ill patients
    • van den Berghe G, Wouters P, Weekers F, et al. Intensive insulin therapy in critically ill patients. N Engl J Med. 2001; 345 (19): 1359-1367.
    • (2001) N Engl J Med , vol.345 , Issue.19 , pp. 1359-1367
    • Van Den Berghe, G.1    Wouters, P.2    Weekers, F.3
  • 31
    • 63249128249 scopus 로고    scopus 로고
    • Intensive versus conventional glucose control in critically ill patients
    • NICE-SUGAR Study Investigators, doi: 10.1056/NEJMoa0810625
    • NICE-SUGAR Study Investigators, Finder S, Chittack DR, et al. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009; 360 (13): 1283-1297. doi: 10.1056/NEJMoa0810625.
    • (2009) N Engl J Med , vol.360 , Issue.13 , pp. 1283-1297
    • Finder, S.1    Chittack, D.R.2
  • 32
    • 84902303827 scopus 로고    scopus 로고
    • Continuous glucose control in the ICU: Report of a 2013 round table meeting
    • Wernerman J, Desaive T, Finfer S, et al. Continuous glucose control in the ICU: report of a 2013 round table meeting. Crit Care. 2014; 18 (3): 226.
    • (2014) Crit Care , vol.18 , Issue.3 , pp. 226
    • Wernerman, J.1    Desaive, T.2    Finfer, S.3
  • 33
    • 84955266456 scopus 로고    scopus 로고
    • Predisposing factors for hypoglycemia and its relation with mortality in critically Ill patients undergoing insulin therapy in an intensive care unit
    • Mahmoodpoor A, Hamishehkar H, Beigmohammadi M, et al. Predisposing factors for hypoglycemia and its relation with mortality in critically Ill patients undergoing insulin therapy in an intensive care unit. Anesth Pain Med. 2016; 6 (1): e33849. doi: 10.5812/aapm.33849.
    • (2016) Anesth Pain Med , vol.6 , Issue.1 , pp. e33849
    • Mahmoodpoor, A.1    Hamishehkar, H.2    Beigmohammadi, M.3
  • 34
    • 33845257074 scopus 로고    scopus 로고
    • Evaluation of nursing work effort and perceptions about blood glucose testing in tight glycemic control
    • Aragon D., Evaluation of nursing work effort and perceptions about blood glucose testing in tight glycemic control. Am J Crit Care. 2006; 15 (4): 370-377.
    • (2006) Am J Crit Care , vol.15 , Issue.4 , pp. 370-377
    • Aragon, D.1
  • 35
    • 84910017396 scopus 로고    scopus 로고
    • The high burden of inpatient diabetes mellitus: The Melbourne Public Hospitals Diabetes Inpatient Audit
    • Bach LA, Ekinci E, Engler D, et al. The high burden of inpatient diabetes mellitus: the Melbourne Public Hospitals Diabetes Inpatient Audit. Med J Aust. 2014; 201 (6): 334-338.
    • (2014) Med J Aust , vol.201 , Issue.6 , pp. 334-338
    • Bach, L.A.1    Ekinci, E.2    Engler, D.3
  • 36
    • 84875149936 scopus 로고    scopus 로고
    • Brief report: Comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin
    • Burt MG, Roberts GW, Aguilar-Loza NR, Stranks SN., Brief report: Comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin. Diabetes Technol Ther. 2013; 15 (3): 241-245. doi: 10.1089/dia.2012.0282.
    • (2013) Diabetes Technol Ther , vol.15 , Issue.3 , pp. 241-245
    • Burt, M.G.1    Roberts, G.W.2    Aguilar-Loza, N.R.3    Stranks, S.N.4
  • 37
    • 77951118509 scopus 로고    scopus 로고
    • Continuous glucose monitoring in subjects after simultaneous pancreas-kidney and kidney-alone transplantation
    • Rodríguez LM, Knight RJ, Heptulla RA., Continuous glucose monitoring in subjects after simultaneous pancreas-kidney and kidney-alone transplantation. Diabetes Technol Ther. 2010; 12 (5): 347-351. doi: 10.1089/dia.2009.0157.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.5 , pp. 347-351
    • Rodríguez, L.M.1    Knight, R.J.2    Heptulla, R.A.3
  • 38
    • 85009281992 scopus 로고    scopus 로고
    • Continuous glucose monitoring versus capillary point-of-care testing for inpatient glycemic control in type 2 diabetes patients hospitalized in the general ward and treated with a basal bolus insulin regimen
    • Gómez AM, Umpierrez GE, Muñoz OM, et al. Continuous glucose monitoring versus capillary point-of-care testing for inpatient glycemic control in type 2 diabetes patients hospitalized in the general ward and treated with a basal bolus insulin regimen. J Diabetes Sci Technol. 2015; 10 (2): 325-329. doi: 10.1177/1932296815602905.
    • (2015) J Diabetes Sci Technol , vol.10 , Issue.2 , pp. 325-329
    • Gómez, A.M.1    Umpierrez, G.E.2    Muñoz, O.M.3
  • 39
    • 84900810008 scopus 로고    scopus 로고
    • Continuous glucose monitoring in newborn infants: How do errors in calibration measurements affect detected hypoglycemia
    • Thomas F, Signal M, Harris DL, et al. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia. J Diabetes Sci Technol. 2014; 8 (3): 543-550.
    • (2014) J Diabetes Sci Technol , vol.8 , Issue.3 , pp. 543-550
    • Thomas, F.1    Signal, M.2    Harris, D.L.3
  • 40
    • 84908164031 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
    • Wong JC, Foster NC, Maahs DM, et al. Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry. Diabetes Care. 2014; 37 (10): 2702-2709.
    • (2014) Diabetes Care , vol.37 , Issue.10 , pp. 2702-2709
    • Wong, J.C.1    Foster, N.C.2    Maahs, D.M.3
  • 41
    • 85009268766 scopus 로고    scopus 로고
    • Impact of frequent and persistent use of continuous glucose monitoring (CGM) on hypoglycemia fear, frequency of emergency medical treatment, and SMBG frequency after one year
    • Chamberlain JJ, Dopita D, Gilgen E, Neuman A., Impact of frequent and persistent use of continuous glucose monitoring (CGM) on hypoglycemia fear, frequency of emergency medical treatment, and SMBG frequency after one year. J Diabetes Sci Technol. 2016; 10 (2): 383-388.
    • (2016) J Diabetes Sci Technol , vol.10 , Issue.2 , pp. 383-388
    • Chamberlain, J.J.1    Dopita, D.2    Gilgen, E.3    Neuman, A.4
  • 42
    • 85009291150 scopus 로고    scopus 로고
    • The impact of real-time continuous glucose monitoring in patients 65 years and older
    • Polonsky WH, Peters AL, Hessler D., The impact of real-time continuous glucose monitoring in patients 65 years and older. J Diabetes Sci Technol. 2016; 10 (4): 892-897.
    • (2016) J Diabetes Sci Technol , vol.10 , Issue.4 , pp. 892-897
    • Polonsky, W.H.1    Peters, A.L.2    Hessler, D.3
  • 43
    • 84873189381 scopus 로고    scopus 로고
    • Determinants of the accuracy of continuous glucose monitoring in non-critically ill patients with heart failure or severe hyperglycemia
    • Dungan KM, Han W, Miele A, Zeidan T, Weiland K., Determinants of the accuracy of continuous glucose monitoring in non-critically ill patients with heart failure or severe hyperglycemia. J Diabetes Sci Technol. 2012; 6 (4): 884-891.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.4 , pp. 884-891
    • Dungan, K.M.1    Han, W.2    Miele, A.3    Zeidan, T.4    Weiland, K.5
  • 44
    • 85010640828 scopus 로고    scopus 로고
    • US Food and Drug Administration. Available at: Accessed January 9, 2017
    • US Food and Drug Administration. FDA approves first automated insulin delivery device for type 1 diabetes. 2016. Available at: http://www.fda.gov/NewsEvents/Newsroom/PressAnnouncements/ucm522974.htm. Accessed January 9, 2017.
    • (2016) FDA Approves First Automated Insulin Delivery Device for Type 1 Diabetes


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.