메뉴 건너뛰기




Volumn 2, Issue 3, 2011, Pages 376-381

Low-Power 2-MHz Pulsed-Wave Transcranial Ultrasound Reduces Ischemic Brain Damage in Rats

Author keywords

Brain edema reduction; Cerebral ischemia; Microcirculation; Transcranial ultrasound

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; BRAIN HEMORRHAGE; BRAIN INFARCTION SIZE; BRAIN ISCHEMIA; CAROTID ARTERY OBSTRUCTION; CONTROLLED STUDY; MIDDLE CEREBRAL ARTERY OCCLUSION; NONHUMAN; PRIORITY JOURNAL; PULSE WAVE; RAT; ULTRASOUND;

EID: 85027934618     PISSN: 18684483     EISSN: 1868601X     Source Type: Journal    
DOI: 10.1007/s12975-011-0080-6     Document Type: Article
Times cited : (11)

References (32)
  • 1
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke
    • The National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group
    • The National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. Tissue plasminogen activator for acute ischemic stroke. N Engl J Med. 1995; 333: 1581-7.
    • (1995) N Engl J Med , vol.333 , pp. 1581-1587
  • 2
    • 52649165720 scopus 로고    scopus 로고
    • Thrombolysis with alteplase 3 to 4.5 h after acute ischemic stroke
    • Hacke W, Kaste M, Bluhmki E, et al. Thrombolysis with alteplase 3 to 4. 5 h after acute ischemic stroke. N Engl J Med. 2008; 359: 1317-29.
    • (2008) N Engl J Med , vol.359 , pp. 1317-1329
    • Hacke, W.1    Kaste, M.2    Bluhmki, E.3
  • 3
    • 41249090658 scopus 로고    scopus 로고
    • National US estimates of recombinant tissue plasminogen activator use: ICD-9 codes substantially underestimate
    • Kleindorfer D, Lindsell CJ, Brass L, Koroshetz W, Broderick JP. National US estimates of recombinant tissue plasminogen activator use: ICD-9 codes substantially underestimate. Stroke. 2008; 39: 924-8.
    • (2008) Stroke , vol.39 , pp. 924-928
    • Kleindorfer, D.1    Lindsell, C.J.2    Brass, L.3    Koroshetz, W.4    Broderick, J.P.5
  • 4
    • 7644242450 scopus 로고    scopus 로고
    • Ultrasound identification and lysis of clots
    • Alexandrov AV. Ultrasound identification and lysis of clots. Stroke. 2004; 35: 2722-5.
    • (2004) Stroke , vol.35 , pp. 2722-2725
    • Alexandrov, A.V.1
  • 5
    • 0027286644 scopus 로고
    • Characterization of ultrasound-potentiated fibrinolysis in vitro
    • Blinc A, Francis CW, Trudnowski JL, Carstensen EL. Characterization of ultrasound-potentiated fibrinolysis in vitro. Blood. 1993; 81: 2636-43.
    • (1993) Blood , vol.81 , pp. 2636-2643
    • Blinc, A.1    Francis, C.W.2    Trudnowski, J.L.3    Carstensen, E.L.4
  • 6
    • 39749112732 scopus 로고    scopus 로고
    • Ultrasound-enhanced tissue plasminogen activator thrombolysis in an in vitro porcine clot model
    • Holland CK, Vaidya SS, Datta S, Coussios CC, Shaw GJ. Ultrasound-enhanced tissue plasminogen activator thrombolysis in an in vitro porcine clot model. Thromb Res. 2008; 121: 663-73.
    • (2008) Thromb Res , vol.121 , pp. 663-673
    • Holland, C.K.1    Vaidya, S.S.2    Datta, S.3    Coussios, C.C.4    Shaw, G.J.5
  • 7
    • 41249097807 scopus 로고    scopus 로고
    • Effective and safe conditions of low-frequency transcranial ultrasound thrombolysis for acute ischemic stroke. Neurologic and histologic evaluation in a rat middle cerebral artery stroke model
    • Saguchi T, Onoue H, Urashima M, Ishibashi T, Abe T, Furuhata H. Effective and safe conditions of low-frequency transcranial ultrasound thrombolysis for acute ischemic stroke. Neurologic and histologic evaluation in a rat middle cerebral artery stroke model. Stroke. 2008; 39: 1007-11.
    • (2008) Stroke , vol.39 , pp. 1007-1011
    • Saguchi, T.1    Onoue, H.2    Urashima, M.3    Ishibashi, T.4    Abe, T.5    Furuhata, H.6
  • 9
    • 2342462270 scopus 로고    scopus 로고
    • Efficacy of sonothrombolysis in a rat model of embolic ischemic stroke
    • Daffertshofer M, Huang Z, Fatar M, et al. Efficacy of sonothrombolysis in a rat model of embolic ischemic stroke. Neurosci Lett. 2004; 361: 115-9.
    • (2004) Neurosci Lett , vol.361 , pp. 115-119
    • Daffertshofer, M.1    Huang, Z.2    Fatar, M.3
  • 10
    • 0028964470 scopus 로고
    • Ultrasound accelerates transport of recombinant tissue plasminogen activator into clots
    • Francis CW, Blinc A, Lee S, Cox C. Ultrasound accelerates transport of recombinant tissue plasminogen activator into clots. Ultrasound Med Biol. 1995; 21: 419-24.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 419-424
    • Francis, C.W.1    Blinc, A.2    Lee, S.3    Cox, C.4
  • 11
    • 33746269049 scopus 로고    scopus 로고
    • Correlation of cavitation with ultrasound enhancement of thrombolysis
    • Datta S, Coussios CC, McAdory LE, et al. Correlation of cavitation with ultrasound enhancement of thrombolysis. Ultrasound Med Biol. 2006; 32: 1257-67.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1257-1267
    • Datta, S.1    Coussios, C.C.2    McAdory, L.E.3
  • 12
    • 0034099863 scopus 로고    scopus 로고
    • High rate of complete recanalization and dramatic clinical recovery during TPA infusion when continuously monitored by 2 MHz transcranial Doppler monitoring
    • Alexandrov AV, Demchuk AM, Felberg RA, et al. High rate of complete recanalization and dramatic clinical recovery during TPA infusion when continuously monitored by 2 MHz transcranial Doppler monitoring. Stroke. 2000; 31: 610-4.
    • (2000) Stroke , vol.31 , pp. 610-614
    • Alexandrov, A.V.1    Demchuk, A.M.2    Felberg, R.A.3
  • 13
    • 0037766220 scopus 로고    scopus 로고
    • Effect of ultrasound on thrombolysis of middle cerebral artery occlusion
    • Eggers J, Koch B, Meyer K, König I, Seidel G. Effect of ultrasound on thrombolysis of middle cerebral artery occlusion. Ann Neurol. 2003; 53: 797-800.
    • (2003) Ann Neurol , vol.53 , pp. 797-800
    • Eggers, J.1    Koch, B.2    Meyer, K.3    König, I.4    Seidel, G.5
  • 14
    • 8644230974 scopus 로고    scopus 로고
    • Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke
    • Alexandrov AV, Molina CA, Grotta JC, et al. Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke. N Engl J Med. 2004; 351: 2170-8.
    • (2004) N Engl J Med , vol.351 , pp. 2170-2178
    • Alexandrov, A.V.1    Molina, C.A.2    Grotta, J.C.3
  • 15
    • 15244339173 scopus 로고    scopus 로고
    • Sonothrombolysis in acute ischemic stroke for patients ineligible for rt-PA
    • Eggers J, Seidel G, Koch B, König IR. Sonothrombolysis in acute ischemic stroke for patients ineligible for rt-PA. Neurology. 2005; 64: 1052-4.
    • (2005) Neurology , vol.64 , pp. 1052-1054
    • Eggers, J.1    Seidel, G.2    Koch, B.3    König, I.R.4
  • 16
    • 0036161168 scopus 로고    scopus 로고
    • High rate of recanalization of middle cerebral artery occlusion during 2-MHz transcranial color-coded Doppler continuous monitoring without thrombolytic drug
    • Cintas P, Le Traon AP, Larrue V. High rate of recanalization of middle cerebral artery occlusion during 2-MHz transcranial color-coded Doppler continuous monitoring without thrombolytic drug. Stroke. 2002; 33: 626-8.
    • (2002) Stroke , vol.33 , pp. 626-628
    • Cintas, P.1    Le Traon, A.P.2    Larrue, V.3
  • 17
    • 49849100560 scopus 로고    scopus 로고
    • Effect of combined ultrasound and microbubbles treatment in an experimental model of cerebral ischemia
    • Fatar M, Stroick M, Griebe M, et al. Effect of combined ultrasound and microbubbles treatment in an experimental model of cerebral ischemia. Ultrasound Med Biol. 2008; 34: 1414-20.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 1414-1420
    • Fatar, M.1    Stroick, M.2    Griebe, M.3
  • 18
    • 77957986957 scopus 로고    scopus 로고
    • Ultrasound-assisted thrombolysis for stroke therapy: better thrombus break-up with bubbles
    • Hitchcock KE, Holland CK. Ultrasound-assisted thrombolysis for stroke therapy: better thrombus break-up with bubbles. Stroke. 2010; 41: 50-3.
    • (2010) Stroke , vol.41 , pp. 50-53
    • Hitchcock, K.E.1    Holland, C.K.2
  • 19
    • 85028097752 scopus 로고    scopus 로고
    • US National Institutes of Health Guide for the Care and Use of Laboratory Animals (NIH Publication No 85-23, revised 1996)
    • US National Institutes of Health Guide for the Care and Use of Laboratory Animals (NIH Publication No 85-23, revised 1996).
  • 20
    • 0029882764 scopus 로고    scopus 로고
    • An alternative method for the quantitation of neuronal damage after experimental middle cerebral artery occlusion in rats: analysis of behavioral deficit
    • Aronowski J, Samways E, Strong R, Rhoades HM, Grotta JC. An alternative method for the quantitation of neuronal damage after experimental middle cerebral artery occlusion in rats: analysis of behavioral deficit. J Cereb Blood Flow Metab. 1996; 16: 705-13.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 705-713
    • Aronowski, J.1    Samways, E.2    Strong, R.3    Rhoades, H.M.4    Grotta, J.C.5
  • 21
    • 33846045133 scopus 로고    scopus 로고
    • Practice standards for transcranial Doppler ultrasound: part I-test performance. American Society of Neuroimaging Practice Guidelines Committee
    • Alexandrov AV, Sloan MA, Wong LK, et al. Practice standards for transcranial Doppler ultrasound: part I-test performance. American Society of Neuroimaging Practice Guidelines Committee. J Neuroimaging. 2007; 17: 11-8.
    • (2007) J Neuroimaging , vol.17 , pp. 11-18
    • Alexandrov, A.V.1    Sloan, M.A.2    Wong, L.K.3
  • 22
    • 0028143448 scopus 로고
    • A graded bioassay for determination of brain rescue from experimental acute ischemia
    • Aronowski J, Ostrow P, Samways E, Strong R, Zivin JA, Grotta JC. A graded bioassay for determination of brain rescue from experimental acute ischemia. Stroke. 1994; 25: 2235-40.
    • (1994) Stroke , vol.25 , pp. 2235-2240
    • Aronowski, J.1    Ostrow, P.2    Samways, E.3    Strong, R.4    Zivin, J.A.5    Grotta, J.C.6
  • 23
    • 77449126716 scopus 로고    scopus 로고
    • Safety and efficacy of ultrasound- enhanced thrombolysis: a comprehensive review and meta-analysis of randomized and nonrandomized studies
    • Tsivgoulis G, Eggers J, Ribo M, et al. Safety and efficacy of ultrasound- enhanced thrombolysis: a comprehensive review and meta-analysis of randomized and nonrandomized studies. Stroke. 2010; 41: 280-7.
    • (2010) Stroke , vol.41 , pp. 280-287
    • Tsivgoulis, G.1    Eggers, J.2    Ribo, M.3
  • 25
    • 33947525764 scopus 로고    scopus 로고
    • Therapeutic application of 20-kHz transcranial ultrasound in an embolic middle cerebral artery occlusion model in rats: safety concerns
    • Wilhelm-Schwenkmezger T, Pittermann P, Zajonz K, Kempski O, Dieterich M, Nedelmann M. Therapeutic application of 20-kHz transcranial ultrasound in an embolic middle cerebral artery occlusion model in rats: safety concerns. Stroke. 2007; 38: 1031-5.
    • (2007) Stroke , vol.38 , pp. 1031-1035
    • Wilhelm-Schwenkmezger, T.1    Pittermann, P.2    Zajonz, K.3    Kempski, O.4    Dieterich, M.5    Nedelmann, M.6
  • 26
    • 0002143429 scopus 로고
    • Transmission of ultrasound through the temporal bone
    • R. Aaslid (Ed.), Wien: Springer
    • Grolimund P. Transmission of ultrasound through the temporal bone. In: Aaslid R, editor. Transcranial Doppler sonography. Wien: Springer; 1986. p. 10-21.
    • (1986) Transcranial Doppler Sonography , pp. 10-21
    • Grolimund, P.1
  • 27
    • 19944427615 scopus 로고    scopus 로고
    • Can a commercial diagnostic ultrasound device accelerate thrombolysis? An in vitro skull model
    • Pfaffenberger S, Devcic-Kuhar B, Kollmann C, et al. Can a commercial diagnostic ultrasound device accelerate thrombolysis? An in vitro skull model. Stroke. 2005; 36: 124-8.
    • (2005) Stroke , vol.36 , pp. 124-128
    • Pfaffenberger, S.1    Devcic-Kuhar, B.2    Kollmann, C.3
  • 28
    • 0028297529 scopus 로고
    • Catheter-delivered high intensity, low frequency ultrasound induces vasdodilation in vivo
    • Steffen W, Cumberland D, Gaines P, et al. Catheter-delivered high intensity, low frequency ultrasound induces vasdodilation in vivo. Eur Heart J. 1994; 15: 369-76.
    • (1994) Eur Heart J , vol.15 , pp. 369-376
    • Steffen, W.1    Cumberland, D.2    Gaines, P.3
  • 29
    • 0026094180 scopus 로고
    • Ultrasound energy: effects on vascular function and integrity
    • Fischell TA, Abbas MA, Grant GW, Siegel RJ. Ultrasound energy: effects on vascular function and integrity. Circulation. 1991; 84: 1783-95.
    • (1991) Circulation , vol.84 , pp. 1783-1795
    • Fischell, T.A.1    Abbas, M.A.2    Grant, G.W.3    Siegel, R.J.4
  • 30
    • 0034674020 scopus 로고    scopus 로고
    • Effect of 40-kHz ultrasound on acute thrombotic ischemia in a rabbit femoral artery thrombosis model: enhancement of thrombolysis and improvement in capillary muscle perfusion
    • Suchkova VN, Baggs RB, Francis CW. Effect of 40-kHz ultrasound on acute thrombotic ischemia in a rabbit femoral artery thrombosis model: enhancement of thrombolysis and improvement in capillary muscle perfusion. Circulation. 2000; 101: 2296-301.
    • (2000) Circulation , vol.101 , pp. 2296-2301
    • Suchkova, V.N.1    Baggs, R.B.2    Francis, C.W.3
  • 31
    • 0036845533 scopus 로고    scopus 로고
    • Ultrasound improves tissue perfusion in ischemic tissue through a nitric oxide dependent mechanism
    • Suchkova VN, Baggs RB, Sahni SK, Francis CW. Ultrasound improves tissue perfusion in ischemic tissue through a nitric oxide dependent mechanism. Thromb Haemost. 2002; 88: 865-70.
    • (2002) Thromb Haemost , vol.88 , pp. 865-870
    • Suchkova, V.N.1    Baggs, R.B.2    Sahni, S.K.3    Francis, C.W.4
  • 32
    • 0029072762 scopus 로고
    • Flow-mediated endothelial mechanotransduction
    • Davics PF. Flow-mediated endothelial mechanotransduction. Physiol Rev. 1995; 75: 519-60.
    • (1995) Physiol Rev , vol.75 , pp. 519-560
    • Davics, P.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.