메뉴 건너뛰기




Volumn 17, Issue S1, 2015, Pages e65-e74

The soft tissue immunologic response to hydroxyapatite-coated transmucosal implant surfaces: A study in humans

Author keywords

Dental implant; Gene expression; Human; Hydroxyapatite; Nanotopography; Osseointegration

Indexed keywords

BIOCOMPATIBLE COATED MATERIAL; BIOMATERIAL; HYDROXYAPATITE; TITANIUM; TOOTH IMPLANT;

EID: 85027921002     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/cid.12128     Document Type: Article
Times cited : (18)

References (35)
  • 1
    • 84867625141 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years
    • Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res 2012; 23(Suppl 6):22-38.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 22-38
    • Pjetursson, B.E.1    Thoma, D.2    Jung, R.3    Zwahlen, M.4    Zembic, A.5
  • 2
    • 84867590569 scopus 로고    scopus 로고
    • Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years
    • Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 2012; 23(Suppl 6):2-21.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 2-21
    • Jung, R.E.1    Zembic, A.2    Pjetursson, B.E.3    Zwahlen, M.4    Thoma, D.S.5
  • 3
    • 84871707650 scopus 로고    scopus 로고
    • A within-implant comparison to evaluate the concept of platform switching: a randomised controlled trial
    • Vandeweghe S, De Bruyn H. A within-implant comparison to evaluate the concept of platform switching: a randomised controlled trial. Eur J Oral Implantol 2012; 5:253-262.
    • (2012) Eur J Oral Implantol , vol.5 , pp. 253-262
    • Vandeweghe, S.1    De Bruyn, H.2
  • 4
    • 77649207617 scopus 로고    scopus 로고
    • Biologic width and morphologic characteristics of soft tissues around immediately loaded implants: studies performed on human autopsy specimens
    • Romanos GE, Traini T, Johansson CB, Piattelli A. Biologic width and morphologic characteristics of soft tissues around immediately loaded implants: studies performed on human autopsy specimens. J Periodontol 2010; 81:70-78.
    • (2010) J Periodontol , vol.81 , pp. 70-78
    • Romanos, G.E.1    Traini, T.2    Johansson, C.B.3    Piattelli, A.4
  • 5
    • 68549092607 scopus 로고    scopus 로고
    • Effects of titanium surface topography on bone integration: a systematic review
    • Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 2009; 20(Suppl 4):172-184.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 172-184
    • Wennerberg, A.1    Albrektsson, T.2
  • 6
    • 65549134300 scopus 로고    scopus 로고
    • Biomimetics: lessons from nature-an overview
    • Bhushan B. Biomimetics: lessons from nature-an overview. Philos Trans R Soc A 2009; 367:1445-1486.
    • (2009) Philos Trans R Soc A , vol.367 , pp. 1445-1486
    • Bhushan, B.1
  • 7
    • 84863867366 scopus 로고    scopus 로고
    • Enhanced implant integration with hierarchically structured implants: a pilot study in rabbits
    • Johansson CB, Gretzer C, Jimbo R, Mattisson I, Ahlberg E. Enhanced implant integration with hierarchically structured implants: a pilot study in rabbits. Clin Oral Implants Res 2012; 23:943-953.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 943-953
    • Johansson, C.B.1    Gretzer, C.2    Jimbo, R.3    Mattisson, I.4    Ahlberg, E.5
  • 8
    • 79960951914 scopus 로고    scopus 로고
    • Nanoporous TiO(2) thin film on titanium oral implants for enhanced human soft tissue adhesion: a light and electron microscopy study
    • Wennerberg A, Frojd V, Olsson M, etal. Nanoporous TiO(2) thin film on titanium oral implants for enhanced human soft tissue adhesion: a light and electron microscopy study. Clin Implant Dent Relat Res 2011; 13:184-196.
    • (2011) Clin Implant Dent Relat Res , vol.13 , pp. 184-196
    • Wennerberg, A.1    Frojd, V.2    Olsson, M.3
  • 10
    • 81555203192 scopus 로고    scopus 로고
    • Genetic responses to nanostructured calcium-phosphate-coated implants
    • Jimbo R, Xue Y, Hayashi M, etal. Genetic responses to nanostructured calcium-phosphate-coated implants. J Dent Res 2011; 90:1422-1427.
    • (2011) J Dent Res , vol.90 , pp. 1422-1427
    • Jimbo, R.1    Xue, Y.2    Hayashi, M.3
  • 11
    • 80055113844 scopus 로고    scopus 로고
    • Histological and three-dimensional evaluation of osseointegration to nanostructured calcium phosphate-coated implants
    • Jimbo R, Coelho PG, Vandeweghe S, etal. Histological and three-dimensional evaluation of osseointegration to nanostructured calcium phosphate-coated implants. Acta Biomater 2011; 7:4229-4234.
    • (2011) Acta Biomater , vol.7 , pp. 4229-4234
    • Jimbo, R.1    Coelho, P.G.2    Vandeweghe, S.3
  • 13
    • 84872922693 scopus 로고    scopus 로고
    • Nano hydroxyapatite-coated implants improve bone nanomechanical properties
    • Jimbo R, Coelho PG, Bryington M, etal. Nano hydroxyapatite-coated implants improve bone nanomechanical properties. J Dent Res 2012; 91:1172-1177.
    • (2012) J Dent Res , vol.91 , pp. 1172-1177
    • Jimbo, R.1    Coelho, P.G.2    Bryington, M.3
  • 14
    • 0034167079 scopus 로고    scopus 로고
    • Effect of a ceramic and a non-ceramic hydroxyapatite on cell growth and procollagen synthesis of cultured human gingival fibroblasts
    • Ruano R, Jaeger RG, Jaeger MM. Effect of a ceramic and a non-ceramic hydroxyapatite on cell growth and procollagen synthesis of cultured human gingival fibroblasts. J Periodontol 2000; 71:540-545.
    • (2000) J Periodontol , vol.71 , pp. 540-545
    • Ruano, R.1    Jaeger, R.G.2    Jaeger, M.M.3
  • 16
    • 84862220992 scopus 로고    scopus 로고
    • A systematic review on the association between genetic predisposition and dental implant biological complications
    • Dereka X, Mardas N, Chin S, Petrie A, Donos N. A systematic review on the association between genetic predisposition and dental implant biological complications. Clin Oral Implants Res 2012; 23:775-788.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 775-788
    • Dereka, X.1    Mardas, N.2    Chin, S.3    Petrie, A.4    Donos, N.5
  • 17
    • 78349308676 scopus 로고    scopus 로고
    • Proinflammatory cytokines in the crevicular fluid of patients with peri-implantitis
    • Javed F, Al-Hezaimi K, Salameh Z, Almas K, Romanos GE. Proinflammatory cytokines in the crevicular fluid of patients with peri-implantitis. Cytokine 2011; 53:8-12.
    • (2011) Cytokine , vol.53 , pp. 8-12
    • Javed, F.1    Al-Hezaimi, K.2    Salameh, Z.3    Almas, K.4    Romanos, G.E.5
  • 18
    • 77952238280 scopus 로고    scopus 로고
    • Proinflammatory cytokines (IL-1beta and TNF-alpha) and chemokines (IL-8 and MIP-1alpha) as markers of peri-implant tissue condition
    • Petkovic AB, Matic SM, Stamatovic NV, etal. Proinflammatory cytokines (IL-1beta and TNF-alpha) and chemokines (IL-8 and MIP-1alpha) as markers of peri-implant tissue condition. Int J Oral Maxillofac Surg 2010; 39:478-485.
    • (2010) Int J Oral Maxillofac Surg , vol.39 , pp. 478-485
    • Petkovic, A.B.1    Matic, S.M.2    Stamatovic, N.V.3
  • 19
    • 45449087921 scopus 로고    scopus 로고
    • qBase relative quantification framework and software for management and automated analysis of real-time quantitative PCR data
    • Hellemans J, Mortier G, De Paepe A, Speleman F, Vandesompele J. qBase relative quantification framework and software for management and automated analysis of real-time quantitative PCR data. Genome Biol 2007; 8:R19.
    • (2007) Genome Biol , vol.8 , pp. R19
    • Hellemans, J.1    Mortier, G.2    De Paepe, A.3    Speleman, F.4    Vandesompele, J.5
  • 20
    • 64149097786 scopus 로고    scopus 로고
    • The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
    • Bustin SA, Benes V, Garson JA, etal. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clin Chem 2009; 55:611-622.
    • (2009) Clin Chem , vol.55 , pp. 611-622
    • Bustin, S.A.1    Benes, V.2    Garson, J.A.3
  • 21
    • 84863902016 scopus 로고    scopus 로고
    • The effects of laser microtexturing of the dental implant collar on crestal bone levels and peri-implant health
    • Botos S, Yousef H, Zweig B, Flinton R, Weiner S. The effects of laser microtexturing of the dental implant collar on crestal bone levels and peri-implant health. Int J Oral Maxillofac Implants 2011; 26:492-498.
    • (2011) Int J Oral Maxillofac Implants , vol.26 , pp. 492-498
    • Botos, S.1    Yousef, H.2    Zweig, B.3    Flinton, R.4    Weiner, S.5
  • 23
    • 44949111488 scopus 로고    scopus 로고
    • The mucosal barrier at implant abutments of different materials
    • Welander M, Abrahamsson I, Berglundh T. The mucosal barrier at implant abutments of different materials. Clin Oral Implants Res 2008; 19:635-641.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 635-641
    • Welander, M.1    Abrahamsson, I.2    Berglundh, T.3
  • 24
    • 0032160238 scopus 로고    scopus 로고
    • The mucosal attachment at different abutments. An experimental study in dogs
    • Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol 1998; 25:721-727.
    • (1998) J Clin Periodontol , vol.25 , pp. 721-727
    • Abrahamsson, I.1    Berglundh, T.2    Glantz, P.O.3    Lindhe, J.4
  • 25
    • 1842558690 scopus 로고    scopus 로고
    • Customized implant abutment copings to achieve biologic, mechanical, and esthetic objectives
    • Rieder CE. Customized implant abutment copings to achieve biologic, mechanical, and esthetic objectives. Int J Periodontics Restorative Dent 1996; 16:20-29.
    • (1996) Int J Periodontics Restorative Dent , vol.16 , pp. 20-29
    • Rieder, C.E.1
  • 26
    • 20744454724 scopus 로고    scopus 로고
    • Periimplant soft tissue barrier at experimental one-piece mini-implants with different surface topography in humans: a light-microscopic overview and histometric analysis
    • Glauser R, Schupbach P, Gottlow J, Hammerle CH. Periimplant soft tissue barrier at experimental one-piece mini-implants with different surface topography in humans: a light-microscopic overview and histometric analysis. Clin Implant Dent Relat Res 2005; 7(Suppl 1):S44-S51.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. S44-S51
    • Glauser, R.1    Schupbach, P.2    Gottlow, J.3    Hammerle, C.H.4
  • 27
    • 77953252287 scopus 로고    scopus 로고
    • Influence of transmucosal designs of three one-piece implant systems on early tissue responses: a histometric study in beagle dogs
    • Kim S, Oh KC, Han DH, etal. Influence of transmucosal designs of three one-piece implant systems on early tissue responses: a histometric study in beagle dogs. Int J Oral Maxillofac Implants 2010; 25:309-314.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 309-314
    • Kim, S.1    Oh, K.C.2    Han, D.H.3
  • 28
    • 80053035354 scopus 로고    scopus 로고
    • Influence of a machined collar on crestal bone changes around titanium implants: a histometric study in the canine mandible
    • Hermann JS, Jones AA, Bakaeen LG, Buser D, Schoolfield JD, Cochran DL. Influence of a machined collar on crestal bone changes around titanium implants: a histometric study in the canine mandible. J Periodontol 2011; 82:1329-1338.
    • (2011) J Periodontol , vol.82 , pp. 1329-1338
    • Hermann, J.S.1    Jones, A.A.2    Bakaeen, L.G.3    Buser, D.4    Schoolfield, J.D.5    Cochran, D.L.6
  • 29
    • 0036617089 scopus 로고    scopus 로고
    • Difference in penetration of horseradish peroxidase tracer as a foreign substance into the peri-implant or junctional epithelium of rat gingivae
    • Ikeda H, Shiraiwa M, Yamaza T, etal. Difference in penetration of horseradish peroxidase tracer as a foreign substance into the peri-implant or junctional epithelium of rat gingivae. Clin Oral Implants Res 2002; 13:243-251.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 243-251
    • Ikeda, H.1    Shiraiwa, M.2    Yamaza, T.3
  • 31
    • 84865991802 scopus 로고    scopus 로고
    • On crestal/marginal bone loss around dental implants
    • Albrektsson T, Buser D, Sennerby L. On crestal/marginal bone loss around dental implants. Int J Prosthodont 2012; 25:320-322.
    • (2012) Int J Prosthodont , vol.25 , pp. 320-322
    • Albrektsson, T.1    Buser, D.2    Sennerby, L.3
  • 32
    • 0033134979 scopus 로고    scopus 로고
    • Effects of hydroxylapatite coating crystallinity on biosolubility, cell attachment efficiency and proliferation in vitro
    • Chou L, Marek B, Wagner WR. Effects of hydroxylapatite coating crystallinity on biosolubility, cell attachment efficiency and proliferation in vitro. Biomaterials 1999; 20:977-985.
    • (1999) Biomaterials , vol.20 , pp. 977-985
    • Chou, L.1    Marek, B.2    Wagner, W.R.3
  • 33
    • 0026785147 scopus 로고
    • Permucosal implantation pilot study with HA-coated dental implant in dogs
    • Lin H, Van't Veen SJ, Klein CP. Permucosal implantation pilot study with HA-coated dental implant in dogs. Biomaterials 1992; 13:825-831.
    • (1992) Biomaterials , vol.13 , pp. 825-831
    • Lin, H.1    Van't Veen, S.J.2    Klein, C.P.3
  • 34
    • 0028533297 scopus 로고
    • Dissolution/reprecipitation and protein adsorption studies of calcium phosphate coatings by FT-IR/ATR techniques
    • Ong JL, Chittur KK, Lucas LC. Dissolution/reprecipitation and protein adsorption studies of calcium phosphate coatings by FT-IR/ATR techniques. J Biomed Mater Res 1994; 28:1337-1346.
    • (1994) J Biomed Mater Res , vol.28 , pp. 1337-1346
    • Ong, J.L.1    Chittur, K.K.2    Lucas, L.C.3
  • 35
    • 80052388134 scopus 로고
    • Is the Vroman effect of importance in the interaction of blood with artificial materials?
    • Leonard E, Vroman L. Is the Vroman effect of importance in the interaction of blood with artificial materials? J Biomater Sci Polym Ed 1992; 3:95-107.
    • (1992) J Biomater Sci Polym Ed , vol.3 , pp. 95-107
    • Leonard, E.1    Vroman, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.