메뉴 건너뛰기




Volumn 57, Issue 9, 2017, Pages 2174-2181

Residual risk of bacterial contamination of platelets: six years of experience with sterility testing

Author keywords

[No Author keywords available]

Indexed keywords

THROMBOCYTE CONCENTRATE;

EID: 85021339267     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/trf.14202     Document Type: Article
Times cited : (63)

References (45)
  • 1
    • 85028679790 scopus 로고    scopus 로고
    • Fatalities reported to FDA following blood collection and transfusion
    • US Food and Drug Administration (FDA). Fatalities reported to FDA following blood collection and transfusion. Annual summary for Fiscal Year 2015 [cited 2017 Jan 11]. Available from: http://www.fda.gov/downloads/BiologicsBloodVaccines/SafetyAvailability/ReportaProblem/TransfusionDonationFatalities/UCM518148.pdf.
    • (2015) Annual summary for Fiscal Year 2015
  • 2
    • 84958078760 scopus 로고    scopus 로고
    • Detection of septic transfusion reactions to platelet transfusions by active and passive surveillance
    • Hong H, Xiao W, Lazarus HM, Good CE, Maitta RW, Jacobs MR. Detection of septic transfusion reactions to platelet transfusions by active and passive surveillance. Blood 2016;127:496-02.
    • (2016) Blood , vol.127 , pp. 402-496
    • Hong, H.1    Xiao, W.2    Lazarus, H.M.3    Good, C.E.4    Maitta, R.W.5    Jacobs, M.R.6
  • 3
    • 84926227351 scopus 로고    scopus 로고
    • Platelet concentrates: reducing the risk of transfusion-transmitted bacterial infections
    • de Korte D, Marcelis JH. Platelet concentrates: reducing the risk of transfusion-transmitted bacterial infections. Int J Clin Transfus Med 2014;2:24-37.
    • (2014) Int J Clin Transfus Med , vol.2 , pp. 24-37
    • de Korte, D.1    Marcelis, J.H.2
  • 4
    • 84876530203 scopus 로고    scopus 로고
    • Bacterial contamination
    • In, Popovsky MA, editor,, Bethesda (MD), American Association of Blood Banks, p
    • Ramirez-Arcos S, Goldman M. Bacterial contamination. In: Popovsky MA, editor, Transfusion reactions. Bethesda (MD): American Association of Blood Banks; 2012. p. 153-81.
    • (2012) Transfusion reactions , pp. 153-181
    • Ramirez-Arcos, S.1    Goldman, M.2
  • 5
    • 84896528444 scopus 로고    scopus 로고
    • Bacterial contamination in platelet concentrates
    • Pietersz RN, Reesink HW, Panzer S, et al. Bacterial contamination in platelet concentrates. Vox Sang 2014;106:256-83.
    • (2014) Vox Sang , vol.106 , pp. 256-283
    • Pietersz, R.N.1    Reesink, H.W.2    Panzer, S.3
  • 6
    • 84943814022 scopus 로고    scopus 로고
    • Fatal false-negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm-positive Staphylococcus epidermidis: a case report
    • Kou Y, Pagotto F, Hannach B, Ramírez-Arcos S. Fatal false-negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm-positive Staphylococcus epidermidis: a case report. Transfusion 2015;55:2384-9.
    • (2015) Transfusion , vol.55 , pp. 2384-2389
    • Kou, Y.1    Pagotto, F.2    Hannach, B.3    Ramírez-Arcos, S.4
  • 7
    • 84870530804 scopus 로고    scopus 로고
    • Detection of bacterial contamination in platelet concentrates using flow cytometry and real-time PCR methods
    • Vollmer T, Kleesiek K, Dreier J. Detection of bacterial contamination in platelet concentrates using flow cytometry and real-time PCR methods. Methods Mol Biol 2013;943:91-103.
    • (2013) Methods Mol Biol , vol.943 , pp. 91-103
    • Vollmer, T.1    Kleesiek, K.2    Dreier, J.3
  • 8
    • 84876149832 scopus 로고    scopus 로고
    • Routine use of a rapid test to detect bacteria at the time of issue for nonleukoreduced, whole blood-derived platelets
    • Harm SK, Delaney M, Charapata M, Aubuchon JP, Truilzi DJ, Yazer MH. Routine use of a rapid test to detect bacteria at the time of issue for nonleukoreduced, whole blood-derived platelets. Transfusion 2013;53:843-50.
    • (2013) Transfusion , vol.53 , pp. 843-850
    • Harm, S.K.1    Delaney, M.2    Charapata, M.3    Aubuchon, J.P.4    Truilzi, D.J.5    Yazer, M.H.6
  • 9
    • 84902182647 scopus 로고    scopus 로고
    • Evaluation of a rapid colorimetric assay for detection of bacterial contamination in apheresis and pooled random-donor platelet units
    • Heaton WA, Good CE, Galloway-Haskins R, Yomtovian RA, Jacobs MR. Evaluation of a rapid colorimetric assay for detection of bacterial contamination in apheresis and pooled random-donor platelet units. Transfusion 2014;54:1634-41.
    • (2014) Transfusion , vol.54 , pp. 1634-1641
    • Heaton, W.A.1    Good, C.E.2    Galloway-Haskins, R.3    Yomtovian, R.A.4    Jacobs, M.R.5
  • 11
    • 85018662245 scopus 로고    scopus 로고
    • Bacterial screening of platelet components by National Health Service Blood and Transplant, an effective risk reduction measure
    • McDonald C, Allen J, Brailsford S, et al. Bacterial screening of platelet components by National Health Service Blood and Transplant, an effective risk reduction measure. Transfusion 2017;57:1122–31.
    • (2017) Transfusion , vol.57 , pp. 1122-1131
    • McDonald, C.1    Allen, J.2    Brailsford, S.3
  • 12
    • 77955443000 scopus 로고    scopus 로고
    • Evaluation of the BacT/ALERT 3D system for the implementation of in-house quality control sterility testing at Canadian Blood Services
    • den Admirant M, Ramírez-Arcos S
    • Mastronardi C, Perkins H, Derksen P, den Admirant M, Ramírez-Arcos S. Evaluation of the BacT/ALERT 3D system for the implementation of in-house quality control sterility testing at Canadian Blood Services. Clin Chem Lab Med 2010;48:1179-87.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1179-1187
    • Mastronardi, C.1    Perkins, H.2    Derksen, P.3
  • 13
    • 55349110645 scopus 로고    scopus 로고
    • Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production
    • Levin E, Culibrk B, Gyöngyössy-Issa MI, et al. Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production. Transfusion 2008;48:2331-7.
    • (2008) Transfusion , vol.48 , pp. 2331-2337
    • Levin, E.1    Culibrk, B.2    Gyöngyössy-Issa, M.I.3
  • 14
    • 80053188319 scopus 로고    scopus 로고
    • Bacterial contamination in platelets: incremental improvements drive down but do not eliminate risk
    • Jenkins C, Ramírez-Arcos S, Goldman M, Devine DV. Bacterial contamination in platelets: incremental improvements drive down but do not eliminate risk. Transfusion 2011;51:2555-65.
    • (2011) Transfusion , vol.51 , pp. 2555-2565
    • Jenkins, C.1    Ramírez-Arcos, S.2    Goldman, M.3    Devine, D.V.4
  • 15
    • 68149131080 scopus 로고    scopus 로고
    • Limiting and detecting bacterial contamination of apheresis platelets: inlet-line diversion and increased culture volume improve component safety
    • Eder AF, Kennedy JM, Dy BA, et al. Limiting and detecting bacterial contamination of apheresis platelets: inlet-line diversion and increased culture volume improve component safety. Transfusion 2009;49:1554-63.
    • (2009) Transfusion , vol.49 , pp. 1554-1563
    • Eder, A.F.1    Kennedy, J.M.2    Dy, B.A.3
  • 16
    • 84890797438 scopus 로고    scopus 로고
    • Bacterial culture of apheresis platelets: a mathematical model of the residual rate of contamination based on unconfirmed positive results
    • Benjamin RJ, Dy B, Perez J, Eder AF, Wagner SJ. Bacterial culture of apheresis platelets: a mathematical model of the residual rate of contamination based on unconfirmed positive results. Vox Sang 2014;106:23-30.
    • (2014) Vox Sang , vol.106 , pp. 23-30
    • Benjamin, R.J.1    Dy, B.2    Perez, J.3    Eder, A.F.4    Wagner, S.J.5
  • 18
    • 85011683943 scopus 로고    scopus 로고
    • Canadian Standards Association (CSA)., Mississauga (ON), Canadian Standards Association
    • Canadian Standards Association (CSA). CSA Standard-Z902-15-blood and blood components. Mississauga (ON): Canadian Standards Association; 2015.
    • (2015) CSA Standard-Z902-15-blood and blood components
  • 19
    • 34547097245 scopus 로고    scopus 로고
    • The residual risk of sepsis: modelling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates
    • Benjamin RJ, Wagner SJ. The residual risk of sepsis: modelling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates. Transfusion 2007;47:1381-9.
    • (2007) Transfusion , vol.47 , pp. 1381-1389
    • Benjamin, R.J.1    Wagner, S.J.2
  • 20
    • 78650800995 scopus 로고    scopus 로고
    • Screening of platelets for bacterial contamination at the Welsh Blood Service
    • Pearce S, Rowe GP, Field SP. Screening of platelets for bacterial contamination at the Welsh Blood Service. Transfus Med 2011;21:25-32.
    • (2011) Transfus Med , vol.21 , pp. 25-32
    • Pearce, S.1    Rowe, G.P.2    Field, S.P.3
  • 21
    • 77649202190 scopus 로고    scopus 로고
    • Screening of single-donor apheresis platelets for bacterial contamination: the PASSPORT study results
    • Dumont LJ, Kleinman S, Murphy JR, et al. Screening of single-donor apheresis platelets for bacterial contamination: the PASSPORT study results. Transfusion 2010;50:589-99.
    • (2010) Transfusion , vol.50 , pp. 589-599
    • Dumont, L.J.1    Kleinman, S.2    Murphy, J.R.3
  • 23
    • 14944356669 scopus 로고    scopus 로고
    • Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results
    • Larsen CP, Ezligini F, Hermansen NO, Kjeldsen-Kragh J. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results. Vox Sang 2005;88:93-7.
    • (2005) Vox Sang , vol.88 , pp. 93-97
    • Larsen, C.P.1    Ezligini, F.2    Hermansen, N.O.3    Kjeldsen-Kragh, J.4
  • 24
    • 44849122863 scopus 로고    scopus 로고
    • Screening platelet concentrates for bacterial contamination: low numbers of bacteria and slow growth in contaminated units mandate an alternative approach to product safety
    • Murphy WG, Foley M, Doherty C, et al. Screening platelet concentrates for bacterial contamination: low numbers of bacteria and slow growth in contaminated units mandate an alternative approach to product safety. Vox Sang 2008;95:13-9.
    • (2008) Vox Sang , vol.95 , pp. 13-19
    • Murphy, W.G.1    Foley, M.2    Doherty, C.3
  • 25
    • 83555176242 scopus 로고    scopus 로고
    • Bacterial screening of outdated buffy coat platelet pools using a culture system and a rapid immunoassay
    • Ramírez-Arcos S, Kou Y, Mastronardi C, Perkins H, Goldman M. Bacterial screening of outdated buffy coat platelet pools using a culture system and a rapid immunoassay. Transfusion 2011;51:2566-72.
    • (2011) Transfusion , vol.51 , pp. 2566-2572
    • Ramírez-Arcos, S.1    Kou, Y.2    Mastronardi, C.3    Perkins, H.4    Goldman, M.5
  • 26
    • 84922991012 scopus 로고    scopus 로고
    • Metabolomic analysis of platelets during storage: a comparison between apheresis- and buffy coat-derived platelet concentrates
    • Paglia G, Sigurjónsson ÓE, Rolfsson Ó, et al. Metabolomic analysis of platelets during storage: a comparison between apheresis- and buffy coat-derived platelet concentrates. Transfusion 2015; 55:301-13.
    • (2015) Transfusion , vol.55 , pp. 301-313
    • Paglia, G.1    Sigurjónsson, Ó.E.2    Rolfsson, Ó.3
  • 27
    • 84978686259 scopus 로고    scopus 로고
    • Bacterial survival and distribution during buffy coat platelet production
    • Taha M, Kalab M, Yi QL, et al. Bacterial survival and distribution during buffy coat platelet production. Vox Sang 2016;111:333-40.
    • (2016) Vox Sang , vol.111 , pp. 333-340
    • Taha, M.1    Kalab, M.2    Yi, Q.L.3
  • 28
    • 40749162766 scopus 로고    scopus 로고
    • Propionibacterium acnes lacks the capability to proliferate in platelet concentrates
    • Störmer M, Kleesiek K, Dreier J. Propionibacterium acnes lacks the capability to proliferate in platelet concentrates. Vox Sang 2008;94:193-01.
    • (2008) Vox Sang , vol.94 , pp. 101-193
    • Störmer, M.1    Kleesiek, K.2    Dreier, J.3
  • 29
    • 84859753444 scopus 로고    scopus 로고
    • Strict anaerobic Staphylococcus saccharolyticus isolates recovered from contaminated platelet concentrates fail to multiply during platelet storage
    • Ali H, Rood IG, de Korte D, Ramírez-Acros S. Strict anaerobic Staphylococcus saccharolyticus isolates recovered from contaminated platelet concentrates fail to multiply during platelet storage. Transfusion 2012;52:916-7.
    • (2012) Transfusion , vol.52 , pp. 916-917
    • Ali, H.1    Rood, I.G.2    de Korte, D.3    Ramírez-Acros, S.4
  • 30
    • 0034521176 scopus 로고    scopus 로고
    • Bacterial contamination of platelet concentrates by Propionibacterium acnes [article in French]
    • Schneider T, Brevière D, Taillefer MF, Pujol-Rey A, Huart JJ. Bacterial contamination of platelet concentrates by Propionibacterium acnes [article in French]. Transfus Clin Biol 2000;7:540-6.
    • (2000) Transfus Clin Biol , vol.7 , pp. 540-546
    • Schneider, T.1    Brevière, D.2    Taillefer, M.F.3    Pujol-Rey, A.4    Huart, J.J.5
  • 31
    • 0032030971 scopus 로고    scopus 로고
    • Fatal Clostridium perfringens sepsis from a pooled platelet transfusion
    • McDonald CP, Hartley S, Orchard K, et al. Fatal Clostridium perfringens sepsis from a pooled platelet transfusion. Transfus Med 1998;8:19-22.
    • (1998) Transfus Med , vol.8 , pp. 19-22
    • McDonald, C.P.1    Hartley, S.2    Orchard, K.3
  • 32
    • 84899472022 scopus 로고    scopus 로고
    • Clostridium perfringens in apheresis platelets: an unusual contaminant underscores the importance of clinical vigilance for septic transfusion reactions (CME)
    • Eder AF, Meena-Leist CE, Hapip CA, Dy BA, Benjamin RJ, Wagner SJ. Clostridium perfringens in apheresis platelets: an unusual contaminant underscores the importance of clinical vigilance for septic transfusion reactions (CME). Transfusion 2014;54:857-62.
    • (2014) Transfusion , vol.54 , pp. 857-862
    • Eder, A.F.1    Meena-Leist, C.E.2    Hapip, C.A.3    Dy, B.A.4    Benjamin, R.J.5    Wagner, S.J.6
  • 33
    • 85028661396 scopus 로고    scopus 로고
    • Fatalities reported to FDA following blood collection and transfusion
    • US Food and Drug Administration (FDA). Fatalities reported to FDA following blood collection and transfusion. Annual summary for Fiscal Year 2010. [cited 2017 Jan 09]. Available from: http://www.fda.gov/downloads/BiologicsBloodVaccines/SafetyAvailability/ReportaProblem/TransfusionDonationFatalities/UCM254860.pdf.
    • (2010) Annual summary for Fiscal Year 2010
  • 35
    • 85018643097 scopus 로고    scopus 로고
    • Yield of proportionate ≥3.8% sample volume of mother bag on bacterial contamination detection in Trima apheresis platelet collections
    • Kamel H, Bravo MD, Townseed M, et al. Yield of proportionate ≥3.8% sample volume of mother bag on bacterial contamination detection in Trima apheresis platelet collections. Transfusion 2015;55:181A.
    • (2015) Transfusion , vol.55 , pp. 181A
    • Kamel, H.1    Bravo, M.D.2    Townseed, M.3
  • 36
    • 33644866009 scopus 로고    scopus 로고
    • Platelet senescent cultures and the predictive value of an early culture [letter]
    • Brecher ME, Hay SN. Platelet senescent cultures and the predictive value of an early culture [letter]. Transfusion 2006;46:311-2.
    • (2006) Transfusion , vol.46 , pp. 311-312
    • Brecher, M.E.1    Hay, S.N.2
  • 37
    • 50849119062 scopus 로고    scopus 로고
    • Bacterial detection in apheresis platelets: blood systems experience with a two-bottle and one-bottle culture system
    • Su LL, Kamel HT, Custer B, et al. Bacterial detection in apheresis platelets: blood systems experience with a two-bottle and one-bottle culture system. Transfusion 2010;48:1842-52.
    • (2010) Transfusion , vol.48 , pp. 1842-1852
    • Su, L.L.1    Kamel, H.T.2    Custer, B.3
  • 38
    • 83555165450 scopus 로고    scopus 로고
    • Evaluation of the elimination of the anaerobic bottle in the testing of plateletpheresis in a blood center. Abstract SP466
    • Corvino T, Strauss D, Lessig M. Evaluation of the elimination of the anaerobic bottle in the testing of plateletpheresis in a blood center. Abstract SP466. Transfusion 2009;49s:227A.
    • (2009) Transfusion , vol.49s , pp. 227A
    • Corvino, T.1    Strauss, D.2    Lessig, M.3
  • 39
    • 84858295091 scopus 로고    scopus 로고
    • Serratia marcescens strains implicated in adverse transfusion reactions form biofilms in platelet concentrates and demonstrate reduced detection by automated culture
    • Greco-Stewart VS, Brown EE, Parr C, et al. Serratia marcescens strains implicated in adverse transfusion reactions form biofilms in platelet concentrates and demonstrate reduced detection by automated culture. Vox Sang 2012;102:212-20.
    • (2012) Vox Sang , vol.102 , pp. 212-220
    • Greco-Stewart, V.S.1    Brown, E.E.2    Parr, C.3
  • 40
    • 42549114908 scopus 로고    scopus 로고
    • Relationship between bacterial load, species virulence, and transfusion reaction with transfusion of bacterially contaminated platelets
    • Jacobs MR, Good CE, Lazarus HM, Yomtovian RA. Relationship between bacterial load, species virulence, and transfusion reaction with transfusion of bacterially contaminated platelets. Clin Infect Dis 2008;46:1214-20.
    • (2008) Clin Infect Dis , vol.46 , pp. 1214-1220
    • Jacobs, M.R.1    Good, C.E.2    Lazarus, H.M.3    Yomtovian, R.A.4
  • 41
    • 85013277051 scopus 로고    scopus 로고
    • Septic transfusion case caused by a platelet pool with visible clotting due to contamination with Staphylococcus aureus
    • Loza-Correa M, Kou Y, Taha M, et al. Septic transfusion case caused by a platelet pool with visible clotting due to contamination with Staphylococcus aureus. Transfusion 2017;57:1299-303.
    • (2017) Transfusion , vol.57 , pp. 1299-1303
    • Loza-Correa, M.1    Kou, Y.2    Taha, M.3
  • 42
    • 85018626233 scopus 로고    scopus 로고
    • Improved bacterial culture of platelet product: preliminary results after implementation of a two-bottle system with 48-hour sampling. Abstract S62-030I
    • Delage G, Bernier F, Beaudoin J, Thibault S, Dion J, Gagne L. Improved bacterial culture of platelet product: preliminary results after implementation of a two-bottle system with 48-hour sampling. Abstract S62-030I. Transfusion 2016;56(S4):28A.
    • (2016) Transfusion , vol.56S4 , pp. 28A
    • Delage, G.1    Bernier, F.2    Beaudoin, J.3    Thibault, S.4    Dion, J.5    Gagne, L.6
  • 43
    • 84904612751 scopus 로고    scopus 로고
    • Bacterial screening of platelet concentrates on day 2 and 3 with flow cytometry: the optimal sampling time point?
    • Vollmer T, Schottstedt V, Bux J, Walther-Wenke G, Knabbe C, Dreier J. Bacterial screening of platelet concentrates on day 2 and 3 with flow cytometry: the optimal sampling time point? Blood Transfus 2014;12:388-95.
    • (2014) Blood Transfus , vol.12 , pp. 388-395
    • Vollmer, T.1    Schottstedt, V.2    Bux, J.3    Walther-Wenke, G.4    Knabbe, C.5    Dreier, J.6
  • 44
    • 85028674376 scopus 로고    scopus 로고
    • Swissmedic haemovigilance annual report, [cited 2017 Jan 10]. Available from
    • Amsler L, Jutzi M. Swissmedic haemovigilance annual report 2015 [cited 2017 Jan 10]. Available from: https://www.swissmedic.ch/suchen/index.html?q=intercept&lang=en&search=.
    • (2015)
    • Amsler, L.1    Jutzi, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.