메뉴 건너뛰기




Volumn 48, Issue 8, 2017, Pages 1727-1734

The Great Unknown—A systematic literature review about risk associated with intraoperative imaging during orthopaedic surgeries

Author keywords

Effective dose; Equivalent dose; Fluoroscopy; Ionizing radiation; Minimal invasive surgery; Occupational risk; Orthopaedic surgery; Radiation exposure

Indexed keywords

FLUOROSCOPY; FOOT SURGERY; HAND SURGERY; HIP SURGERY; HUMAN; INTRAOPERATIVE PERIOD; IONIZING RADIATION; KYPHOPLASTY; OCCUPATIONAL HAZARD; ORTHOPEDIC SURGEON; ORTHOPEDIC SURGERY; PERCUTANEOUS VERTEBROPLASTY; PRIORITY JOURNAL; RADIATION EXPOSURE; RADIATION PROTECTION; REVIEW; RISK ASSESSMENT; SYSTEMATIC REVIEW; TRAUMATOLOGY; OCCUPATIONAL EXPOSURE; PRACTICE GUIDELINE; PREVENTION AND CONTROL; PROCEDURES; PROTOCOL COMPLIANCE; RADIATION DOSE; RADIATION INJURY; UTILIZATION;

EID: 85021200750     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2017.04.041     Document Type: Review
Times cited : (54)

References (72)
  • 2
    • 18744389169 scopus 로고    scopus 로고
    • Occupational radiation exposure to the surgeon
    • Singer, G., Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 13 (2005), 69–76.
    • (2005) J Am Acad Orthop Surg , vol.13 , pp. 69-76
    • Singer, G.1
  • 3
    • 85027483347 scopus 로고    scopus 로고
    • United Nations Scientific Committee on the Effects of Atomic Radiation UNSCEAR 2012 Report to the General Assembly, with scientific annexes A and B. Fifty-ninth session (21–25 May 2012) A/67/45.
    • United Nations Scientific Committee on the Effects of Atomic Radiation UNSCEAR 2012 Report to the General Assembly, with scientific annexes A and B. Fifty-ninth session (21–25 May 2012) A/67/45.
  • 4
    • 84863101376 scopus 로고    scopus 로고
    • ICRP Publication 117 Radiological protection in fluoroscopically guided procedures performed outside the imaging department
    • Rehani, M.M., Ciraj-Bjelac, O., Vano, E., Miller, D.L., Walsh, S., Giordano, B.D., et al. ICRP Publication 117 Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40 (2010), 1–102.
    • (2010) Ann ICRP , vol.40 , pp. 1-102
    • Rehani, M.M.1    Ciraj-Bjelac, O.2    Vano, E.3    Miller, D.L.4    Walsh, S.5    Giordano, B.D.6
  • 5
    • 20444448133 scopus 로고    scopus 로고
    • Somatic DNA damage in interventional cardiologists: a case-control study
    • Andreassi, M.G., Cioppa, A., Botto, N., Joksic, G., Manfredi, S., Federici, C., et al. Somatic DNA damage in interventional cardiologists: a case-control study. FASEB J 19 (2005), 998–999.
    • (2005) FASEB J , vol.19 , pp. 998-999
    • Andreassi, M.G.1    Cioppa, A.2    Botto, N.3    Joksic, G.4    Manfredi, S.5    Federici, C.6
  • 6
    • 77955975621 scopus 로고    scopus 로고
    • Biological effects of low-dose ionizing radiation exposure on interventional cardiologists
    • Zakeri, F., Hirobe, T., Akbari Noghabi, K., Biological effects of low-dose ionizing radiation exposure on interventional cardiologists. Occup Med (Lond) 60 (2010), 464–469.
    • (2010) Occup Med (Lond) , vol.60 , pp. 464-469
    • Zakeri, F.1    Hirobe, T.2    Akbari Noghabi, K.3
  • 10
    • 51749085638 scopus 로고    scopus 로고
    • Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists
    • Chodick, G., Bekiroglu, N., Hauptmann, M., Alexander, B.H., Freedman, D.M., Doody, M.M., et al. Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists. Am J Epidemiol 168 (2008), 620–631.
    • (2008) Am J Epidemiol , vol.168 , pp. 620-631
    • Chodick, G.1    Bekiroglu, N.2    Hauptmann, M.3    Alexander, B.H.4    Freedman, D.M.5    Doody, M.M.6
  • 14
    • 79959470062 scopus 로고    scopus 로고
    • Fluoroscopic exposure in modern spinal surgery
    • Fransen, P., Fluoroscopic exposure in modern spinal surgery. Acta Orthop Belg 77 (2011), 386–389.
    • (2011) Acta Orthop Belg , vol.77 , pp. 386-389
    • Fransen, P.1
  • 15
    • 0037932662 scopus 로고    scopus 로고
    • Radiation dosage in orthopedics – a comparison of computer-assisted procedures
    • Gebhard, F., Kraus, M., Schneider, E., Arand, M., Kinzl, L., Hebecker, A., et al. Radiation dosage in orthopedics – a comparison of computer-assisted procedures. Unfallchirurg 106 (2003), 492–497.
    • (2003) Unfallchirurg , vol.106 , pp. 492-497
    • Gebhard, F.1    Kraus, M.2    Schneider, E.3    Arand, M.4    Kinzl, L.5    Hebecker, A.6
  • 16
    • 45949103909 scopus 로고    scopus 로고
    • Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery
    • Kim, C.W., Lee, Y.P., Taylor, W., Oygar, A., Kim, W.K., Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J 8 (2008), 584–590.
    • (2008) Spine J , vol.8 , pp. 584-590
    • Kim, C.W.1    Lee, Y.P.2    Taylor, W.3    Oygar, A.4    Kim, W.K.5
  • 17
    • 0037624000 scopus 로고    scopus 로고
    • Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose
    • Kruger, R., Faciszewski, T., Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose. Spine 28 (2003), 1608–1613.
    • (2003) Spine , vol.28 , pp. 1608-1613
    • Kruger, R.1    Faciszewski, T.2
  • 18
    • 84881236844 scopus 로고    scopus 로고
    • Operating room radiation exposure in cone beam computed tomography-based, image-guided spinal surgery: clinical article
    • Nottmeier, E.W., Pirris, S.M., Edwards, S., Kimes, S., Bowman, C., Nelson, K.L., Operating room radiation exposure in cone beam computed tomography-based, image-guided spinal surgery: clinical article. J Neurosurg Spine 19 (2013), 226–231.
    • (2013) J Neurosurg Spine , vol.19 , pp. 226-231
    • Nottmeier, E.W.1    Pirris, S.M.2    Edwards, S.3    Kimes, S.4    Bowman, C.5    Nelson, K.L.6
  • 20
    • 8444234679 scopus 로고    scopus 로고
    • The need to protect the thyroid gland during image intensifier use in orthopaedic procedures
    • Devalia, K.L., Guha, A., Devadoss, V.G., The need to protect the thyroid gland during image intensifier use in orthopaedic procedures. Acta Orthop Belg 70 (2004), 474–477.
    • (2004) Acta Orthop Belg , vol.70 , pp. 474-477
    • Devalia, K.L.1    Guha, A.2    Devadoss, V.G.3
  • 21
    • 67650915535 scopus 로고    scopus 로고
    • Optimising use of the mini C-arm in foot and ankle surgery
    • Gangopadhyay, S., Scammell, B.E., Optimising use of the mini C-arm in foot and ankle surgery. Foot Ankle Surg 15 (2009), 139–143.
    • (2009) Foot Ankle Surg , vol.15 , pp. 139-143
    • Gangopadhyay, S.1    Scammell, B.E.2
  • 22
    • 0036090783 scopus 로고    scopus 로고
    • Radiation exposure using laser aiming guide in orthopaedic procedures
    • Harris, I., Walker, P.M., Trieu, L., Radiation exposure using laser aiming guide in orthopaedic procedures. ANZ J Surg 72 (2002), 349–351.
    • (2002) ANZ J Surg , vol.72 , pp. 349-351
    • Harris, I.1    Walker, P.M.2    Trieu, L.3
  • 23
    • 0036788370 scopus 로고    scopus 로고
    • Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb
    • Madan, S., Blakeway, C., Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb. Injury 33 (2002), 723–727.
    • (2002) Injury , vol.33 , pp. 723-727
    • Madan, S.1    Blakeway, C.2
  • 24
    • 37849053955 scopus 로고    scopus 로고
    • A comparison of radiation exposure with the conventional versus mini C arm in orthopedic extremity surgery
    • Shoaib, A., Rethnam, U., Bansal, R., De, A., Makwana, N., A comparison of radiation exposure with the conventional versus mini C arm in orthopedic extremity surgery. Foot Ankle Int 29 (2008), 58–61.
    • (2008) Foot Ankle Int , vol.29 , pp. 58-61
    • Shoaib, A.1    Rethnam, U.2    Bansal, R.3    De, A.4    Makwana, N.5
  • 25
    • 0034873912 scopus 로고    scopus 로고
    • Scattered radiation during fixation of hip fractures. Is distance alone enough protection?
    • Alonso, J.A., Shaw, D.L., Maxwell, A., McGill, G.P., Hart, G.C., Scattered radiation during fixation of hip fractures. Is distance alone enough protection?. J Bone Joint Surg Br 83 (2001), 815–818.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 815-818
    • Alonso, J.A.1    Shaw, D.L.2    Maxwell, A.3    McGill, G.P.4    Hart, G.C.5
  • 28
    • 79551565903 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during open lumbar microdiscectomy and minimally invasive microdiscectomy: a prospective, controlled trial
    • Mariscalco, M.W., Yamashita, T., Steinmetz, M.P., Krishnaney, A.A., Lieberman, I.H., Mroz, T.E., Radiation exposure to the surgeon during open lumbar microdiscectomy and minimally invasive microdiscectomy: a prospective, controlled trial. Spine (Phila Pa 1976) 36 (2011), 255–260.
    • (2011) Spine (Phila Pa 1976) , vol.36 , pp. 255-260
    • Mariscalco, M.W.1    Yamashita, T.2    Steinmetz, M.P.3    Krishnaney, A.A.4    Lieberman, I.H.5    Mroz, T.E.6
  • 29
    • 84879397068 scopus 로고    scopus 로고
    • Evaluation of operator radioprotection using a new injection device during vertebroplasty
    • Nguyen-Kim, L., Fargeot, C., Beaussier, H., Payen, S., Chiras, J., Evaluation of operator radioprotection using a new injection device during vertebroplasty. Interv Neuroradiol 19 (2013), 173–179.
    • (2013) Interv Neuroradiol , vol.19 , pp. 173-179
    • Nguyen-Kim, L.1    Fargeot, C.2    Beaussier, H.3    Payen, S.4    Chiras, J.5
  • 30
    • 33646590640 scopus 로고    scopus 로고
    • Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training
    • Oddy, M.J., Aldam, C.H., Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training. Ann R Coll Surg Eng 88 (2006), 297–301.
    • (2006) Ann R Coll Surg Eng , vol.88 , pp. 297-301
    • Oddy, M.J.1    Aldam, C.H.2
  • 32
    • 84874430888 scopus 로고    scopus 로고
    • Computer navigation in orthopedic trauma: safer surgeries with less irradiation and more precision
    • Akins, R., Abdelgawad, A.A., Kanlic, E.M., Computer navigation in orthopedic trauma: safer surgeries with less irradiation and more precision. J Surg Orthop Adv 21 (2012), 187–197.
    • (2012) J Surg Orthop Adv , vol.21 , pp. 187-197
    • Akins, R.1    Abdelgawad, A.A.2    Kanlic, E.M.3
  • 33
    • 84900394026 scopus 로고    scopus 로고
    • Occupational hazards for pregnant or lactating women in the orthopaedic operating room
    • Downes, J., Rauk, P.N., Vanheest, A.E., Occupational hazards for pregnant or lactating women in the orthopaedic operating room. J Am Acad Orthop Surg 22 (2014), 326–332.
    • (2014) J Am Acad Orthop Surg , vol.22 , pp. 326-332
    • Downes, J.1    Rauk, P.N.2    Vanheest, A.E.3
  • 34
    • 79953037213 scopus 로고    scopus 로고
    • X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room
    • Dresing, K., X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room. Oper Orthop Traumatol 23 (2011), 70–78.
    • (2011) Oper Orthop Traumatol , vol.23 , pp. 70-78
    • Dresing, K.1
  • 36
    • 0343674725 scopus 로고    scopus 로고
    • The effects, risks, and guidelines for radiation use in orthopaedic surgery
    • Herscovici, D. Jr., Sanders, R.W., The effects, risks, and guidelines for radiation use in orthopaedic surgery. Clin Orthop Relat Res 375 (2000), 126–132.
    • (2000) Clin Orthop Relat Res , vol.375 , pp. 126-132
    • Herscovici, D.1    Sanders, R.W.2
  • 38
    • 84873022977 scopus 로고    scopus 로고
    • Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review
    • Kesavachandran, C.N., Haamann, F., Nienhaus, A., Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review. Eur J Med Res, 17, 2012, 28.
    • (2012) Eur J Med Res , vol.17 , pp. 28
    • Kesavachandran, C.N.1    Haamann, F.2    Nienhaus, A.3
  • 39
    • 84861488891 scopus 로고    scopus 로고
    • A review of image-guided spinal surgery
    • Nottmeier, E.W., A review of image-guided spinal surgery. J Neurosurg Sci 56 (2012), 35–47.
    • (2012) J Neurosurg Sci , vol.56 , pp. 35-47
    • Nottmeier, E.W.1
  • 40
    • 84855556949 scopus 로고    scopus 로고
    • Occupational radiation exposure and pregnancy in orthopaedics
    • Uzoigwe, C.E., Middleton, R.G., Occupational radiation exposure and pregnancy in orthopaedics. J Bone Joint Surg Br 94 (2012), 23–27.
    • (2012) J Bone Joint Surg Br , vol.94 , pp. 23-27
    • Uzoigwe, C.E.1    Middleton, R.G.2
  • 41
    • 84901261284 scopus 로고    scopus 로고
    • Does less invasive spine surgery result in increased radiation exposure? A systematic review
    • Yu, E., Khan, S.N., Does less invasive spine surgery result in increased radiation exposure? A systematic review. Clin Orthop Relat Res 472 (2014), 1738–1748.
    • (2014) Clin Orthop Relat Res , vol.472 , pp. 1738-1748
    • Yu, E.1    Khan, S.N.2
  • 42
    • 78549283763 scopus 로고    scopus 로고
    • Dual guidance (CT and fluoroscopy) vertebroplasty: radiation dose to radiologists. How much and where?
    • Amoretti, N., Lesbats, V., Marcy, P.Y., Hauger, O., Amoretti, M.E., Maratos, Y., et al. Dual guidance (CT and fluoroscopy) vertebroplasty: radiation dose to radiologists. How much and where?. Skeletal Radiol 39 (2010), 1229–1235.
    • (2010) Skeletal Radiol , vol.39 , pp. 1229-1235
    • Amoretti, N.1    Lesbats, V.2    Marcy, P.Y.3    Hauger, O.4    Amoretti, M.E.5    Maratos, Y.6
  • 43
    • 84884157464 scopus 로고    scopus 로고
    • Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures
    • Struelens, L., Schoonjans, W., Schils, F., De Smedt, K., Vanhavere, F., Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures. J Radiol Prot 33 (2013), 635–645.
    • (2013) J Radiol Prot , vol.33 , pp. 635-645
    • Struelens, L.1    Schoonjans, W.2    Schils, F.3    De Smedt, K.4    Vanhavere, F.5
  • 44
    • 23944475576 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study
    • Harstall, R., Heini, P.F., Mini, R.L., Orler, R., Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine (Phila Pa 1976) 30 (2005), 1893–1898.
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 1893-1898
    • Harstall, R.1    Heini, P.F.2    Mini, R.L.3    Orler, R.4
  • 45
    • 84881557243 scopus 로고    scopus 로고
    • The surgeon's real dose exposure during balloon kyphoplasty procedure and evaluation of the cement delivery system: a prospective study
    • Schils, F., Schoojans, W., Struelens, L., The surgeon's real dose exposure during balloon kyphoplasty procedure and evaluation of the cement delivery system: a prospective study. Eur Spine J 22 (2013), 1758–1764.
    • (2013) Eur Spine J , vol.22 , pp. 1758-1764
    • Schils, F.1    Schoojans, W.2    Struelens, L.3
  • 46
    • 33644904046 scopus 로고    scopus 로고
    • Surgeon's radiation exposure during percutaneous vertebroplasty
    • Synowitz, M., Kiwit, J., Surgeon's radiation exposure during percutaneous vertebroplasty. J Neurosurg Spine 4 (2006), 106–109.
    • (2006) J Neurosurg Spine , vol.4 , pp. 106-109
    • Synowitz, M.1    Kiwit, J.2
  • 47
    • 41949113413 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon and the patient during kyphoplasty
    • Mroz, T.E., Yamashita, T., Davros, W.J., Lieberman, I.H., Radiation exposure to the surgeon and the patient during kyphoplasty. J Spinal Disord Tech 21 (2008), 96–100.
    • (2008) J Spinal Disord Tech , vol.21 , pp. 96-100
    • Mroz, T.E.1    Yamashita, T.2    Davros, W.J.3    Lieberman, I.H.4
  • 48
    • 66949137794 scopus 로고    scopus 로고
    • Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure
    • von Wrangel, A., Cederblad, A., Rodriguez-Catarino, M., Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure. Acta Radiol 50 (2009), 490–496.
    • (2009) Acta Radiol , vol.50 , pp. 490-496
    • von Wrangel, A.1    Cederblad, A.2    Rodriguez-Catarino, M.3
  • 49
    • 84872476327 scopus 로고    scopus 로고
    • Comparing radiation exposure during percutaneous vertebroplasty using one- vs: two-fluoroscopic technique
    • Li, Y.Y., Huang, T.J., Cheng, C.C., Wu, M.H., Lee, C.Y., Comparing radiation exposure during percutaneous vertebroplasty using one- vs: two-fluoroscopic technique. BMC Musculoskelet Disord, 14, 2013, 38.
    • (2013) BMC Musculoskelet Disord , vol.14 , pp. 38
    • Li, Y.Y.1    Huang, T.J.2    Cheng, C.C.3    Wu, M.H.4    Lee, C.Y.5
  • 50
    • 84864451582 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system
    • Abdullah, K.G., Bishop, F.S., Lubelski, D., Steinmetz, M.P., Benzel, E.C., Mroz, T.E., Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system. Spine (Phila Pa 1976) 37 (2012), E1074–E1078.
    • (2012) Spine (Phila Pa 1976) , vol.37 , pp. E1074-E1078
    • Abdullah, K.G.1    Bishop, F.S.2    Lubelski, D.3    Steinmetz, M.P.4    Benzel, E.C.5    Mroz, T.E.6
  • 51
    • 84861575929 scopus 로고    scopus 로고
    • Surgeon radiation exposure in cone beam computed tomography-based, image-guided spinal surgery
    • Nottmeier, E.W., Bowman, C., Nelson, K.L., Surgeon radiation exposure in cone beam computed tomography-based, image-guided spinal surgery. Int J Med Robot 8 (2012), 196–200.
    • (2012) Int J Med Robot , vol.8 , pp. 196-200
    • Nottmeier, E.W.1    Bowman, C.2    Nelson, K.L.3
  • 52
    • 84876416562 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study
    • Ul Haque, M., Shufflebarger, H.L., O'Brien, M., Macagno, A., Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study. Spine (Phila Pa 1976) 38 (2013), 617–625.
    • (2013) Spine (Phila Pa 1976) , vol.38 , pp. 617-625
    • Ul Haque, M.1    Shufflebarger, H.L.2    O'Brien, M.3    Macagno, A.4
  • 53
    • 84876416562 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study
    • Ahn, Y., Kim, C.H., Lee, J.H., Lee, S.H., Kim, J.S., Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study. Spine (Phila Pa 1976) 38 (2013), 617–625.
    • (2013) Spine (Phila Pa 1976) , vol.38 , pp. 617-625
    • Ahn, Y.1    Kim, C.H.2    Lee, J.H.3    Lee, S.H.4    Kim, J.S.5
  • 54
    • 34848919537 scopus 로고    scopus 로고
    • Measurement of the dose of radiation to the surgeon during surgery to the foot and ankle
    • Singh, P.J., Perera, N.S., Dega, R., Measurement of the dose of radiation to the surgeon during surgery to the foot and ankle. J Bone Joint Surg Br 89 (2007), 1060–1063.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 1060-1063
    • Singh, P.J.1    Perera, N.S.2    Dega, R.3
  • 55
    • 33646523172 scopus 로고    scopus 로고
    • Radiation exposure of the hands and thyroid gland during percutaneous wiring of wrist and hand procedures
    • Bahari, S., Morris, S., Broe, D., Taylor, C., Lenehan, B., McElwain, J., Radiation exposure of the hands and thyroid gland during percutaneous wiring of wrist and hand procedures. Acta Orthop Belg 72 (2006), 194–198.
    • (2006) Acta Orthop Belg , vol.72 , pp. 194-198
    • Bahari, S.1    Morris, S.2    Broe, D.3    Taylor, C.4    Lenehan, B.5    McElwain, J.6
  • 56
    • 22544432535 scopus 로고    scopus 로고
    • Radiation exposure to the hands from mini C-arm fluoroscopy
    • Singer, G., Radiation exposure to the hands from mini C-arm fluoroscopy. J Hand Surg Am 30 (2005), 795–797.
    • (2005) J Hand Surg Am , vol.30 , pp. 795-797
    • Singer, G.1
  • 57
    • 79953735033 scopus 로고    scopus 로고
    • Hand and body radiation exposure with the use of mini C-arm fluoroscopy
    • Tuohy, C.J., Weikert, D.R., Watson, J.T., Lee, D.H., Hand and body radiation exposure with the use of mini C-arm fluoroscopy. J Hand Surg Am 36 (2011), 632–638.
    • (2011) J Hand Surg Am , vol.36 , pp. 632-638
    • Tuohy, C.J.1    Weikert, D.R.2    Watson, J.T.3    Lee, D.H.4
  • 58
    • 79953759421 scopus 로고    scopus 로고
    • Exposure from the large C-arm versus the mini C-arm using hand/wrist and elbow phantoms
    • Singer, G., Herron, B., Herron, D., Exposure from the large C-arm versus the mini C-arm using hand/wrist and elbow phantoms. J Hand Surg Am 36 (2011), 628–631.
    • (2011) J Hand Surg Am , vol.36 , pp. 628-631
    • Singer, G.1    Herron, B.2    Herron, D.3
  • 59
    • 72349091132 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy
    • Mechlenburg, I., Daugaard, H., Soballe, K., Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy. Int Orthop 33 (2009), 1747–1751.
    • (2009) Int Orthop , vol.33 , pp. 1747-1751
    • Mechlenburg, I.1    Daugaard, H.2    Soballe, K.3
  • 60
    • 84858137760 scopus 로고    scopus 로고
    • Risk of ionising radiation to trainee orthopaedic surgeons
    • Khan, I.A., Kamalasekaran, S., Fazal, M.A., Risk of ionising radiation to trainee orthopaedic surgeons. Acta Orthop Belg 78 (2012), 106–110.
    • (2012) Acta Orthop Belg , vol.78 , pp. 106-110
    • Khan, I.A.1    Kamalasekaran, S.2    Fazal, M.A.3
  • 61
    • 11244271466 scopus 로고    scopus 로고
    • Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study
    • Blattert, T.R., Fill, U.A., Kunz, E., Panzer, W., Weckbach, A., Regulla, D.F., Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study. Arch Orthop Trauma Surg 124 (2004), 659–664.
    • (2004) Arch Orthop Trauma Surg , vol.124 , pp. 659-664
    • Blattert, T.R.1    Fill, U.A.2    Kunz, E.3    Panzer, W.4    Weckbach, A.5    Regulla, D.F.6
  • 62
    • 21244434304 scopus 로고    scopus 로고
    • Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk?
    • Hafez, M.A., Smith, R.M., Matthews, S.J., Kalap, G., Sherman, K.P., Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk?. Arch Orthop Trauma Surg 125 (2005), 330–335.
    • (2005) Arch Orthop Trauma Surg , vol.125 , pp. 330-335
    • Hafez, M.A.1    Smith, R.M.2    Matthews, S.J.3    Kalap, G.4    Sherman, K.P.5
  • 63
    • 0037899040 scopus 로고    scopus 로고
    • Which one is at risk in intraoperative fluoroscopy? Assistant surgeon or orthopaedic surgeon?
    • Tasbas, B.A., Yagmurlu, M.F., Bayrakci, K., Ucaner, A., Heybeli, M., Which one is at risk in intraoperative fluoroscopy? Assistant surgeon or orthopaedic surgeon?. Arch Orthop Trauma Surg 123 (2003), 242–244.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 242-244
    • Tasbas, B.A.1    Yagmurlu, M.F.2    Bayrakci, K.3    Ucaner, A.4    Heybeli, M.5
  • 64
    • 84866469324 scopus 로고    scopus 로고
    • Radiation dose to surgeons in theatre
    • van der Merwe, B., Radiation dose to surgeons in theatre. S Afr J Surg 50 (2012), 26–29.
    • (2012) S Afr J Surg , vol.50 , pp. 26-29
    • van der Merwe, B.1
  • 66
    • 33750588368 scopus 로고    scopus 로고
    • Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: methods and techniques
    • Ortiz, A.O., Natarajan, V., Gregorius, D.R., Pollack, S., Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: methods and techniques. AJNR Am J Neuroradiol 27 (2006), 989–994.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 989-994
    • Ortiz, A.O.1    Natarajan, V.2    Gregorius, D.R.3    Pollack, S.4
  • 67
    • 33751574499 scopus 로고    scopus 로고
    • Exposure of the thyroid to radiation during routine orthopaedic procedures
    • Devalia, K.L., Peter, V.K., Madanur, M.A., Braithwaite, I.J., Exposure of the thyroid to radiation during routine orthopaedic procedures. Acta Orthop Belg 72 (2006), 615–620.
    • (2006) Acta Orthop Belg , vol.72 , pp. 615-620
    • Devalia, K.L.1    Peter, V.K.2    Madanur, M.A.3    Braithwaite, I.J.4
  • 68
    • 84884498411 scopus 로고    scopus 로고
    • Leaded eyeglasses substantially reduce radiation exposure of the surgeon's eyes during acquisition of typical fluoroscopic views of the hip and pelvis
    • Burns, S., Thornton, R., Dauer, L.T., Quinn, B., Miodownik, D., Hak, D.J., Leaded eyeglasses substantially reduce radiation exposure of the surgeon's eyes during acquisition of typical fluoroscopic views of the hip and pelvis. J Bone Joint Surg Am 95 (2013), 1307–1311.
    • (2013) J Bone Joint Surg Am , vol.95 , pp. 1307-1311
    • Burns, S.1    Thornton, R.2    Dauer, L.T.3    Quinn, B.4    Miodownik, D.5    Hak, D.J.6
  • 69
    • 58849164909 scopus 로고    scopus 로고
    • Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion
    • Bindal, R.K., Glaze, S., Ognoskie, M., Tunner, V., Malone, R., Ghosh, S., Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 9 (2008), 570–573.
    • (2008) J Neurosurg Spine , vol.9 , pp. 570-573
    • Bindal, R.K.1    Glaze, S.2    Ognoskie, M.3    Tunner, V.4    Malone, R.5    Ghosh, S.6
  • 70
    • 84880760129 scopus 로고    scopus 로고
    • Young Investigator Award winner: how safe is lateral lumbar interbody fusion for the surgeon? A prospective in vivo radiation exposure study
    • Taher, F., Hughes, A.P., Sama, A.A., Zeldin, R., Schneider, R., Holodny, E.I., et al. Young Investigator Award winner: how safe is lateral lumbar interbody fusion for the surgeon? A prospective in vivo radiation exposure study. Spine (Phila Pa 1976) 38 (2013), 1386–1392.
    • (2013) Spine (Phila Pa 1976) , vol.38 , pp. 1386-1392
    • Taher, F.1    Hughes, A.P.2    Sama, A.A.3    Zeldin, R.4    Schneider, R.5    Holodny, E.I.6
  • 71
    • 20444437186 scopus 로고    scopus 로고
    • Radiation scattering to the primary surgeon during closed locked femoral nailing
    • Mahaisavariya, B., Songcharoen, P., Riansuwan, K., Radiation scattering to the primary surgeon during closed locked femoral nailing. J Med Assoc Thai 88 (2005), 252–255.
    • (2005) J Med Assoc Thai , vol.88 , pp. 252-255
    • Mahaisavariya, B.1    Songcharoen, P.2    Riansuwan, K.3
  • 72
    • 77649165384 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during femoral interlocking nailing under fluoroscopic imaging
    • Muzaffar, T.S., Imran, Y., Iskandar, M.A., Zakaria, A., Radiation exposure to the surgeon during femoral interlocking nailing under fluoroscopic imaging. Med J Malaysia 60:Suppl. C (2005), 26–29.
    • (2005) Med J Malaysia , vol.60 , pp. 26-29
    • Muzaffar, T.S.1    Imran, Y.2    Iskandar, M.A.3    Zakaria, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.