-
1
-
-
0037006146
-
Minimally invasive treatment of osteoporotic vertebral body compression fractures
-
10.1016/S1529-9430(01)00166-8 14588292
-
SR Garfin MA Reilley 2002 Minimally invasive treatment of osteoporotic vertebral body compression fractures Spine J 2 76 80 10.1016/S1529-9430(01) 00166-8 14588292
-
(2002)
Spine J
, vol.2
, pp. 76-80
-
-
Garfin, S.R.1
Reilley, M.A.2
-
2
-
-
0035879089
-
New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
-
DOI 10.1097/00007632-200107150-00002
-
SR Garfin HA Yuan MA Reiley 2001 New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures Spine 26 1511 5 1:STN:280:DC%2BD3Mvht1Onsw%3D%3D 10.1097/00007632- 200107150-00002 11462078 (Pubitemid 32646119)
-
(2001)
Spine
, vol.26
, Issue.14
, pp. 1511-1515
-
-
Garfin, S.R.1
Yuan, H.A.2
Reiley, M.A.3
-
3
-
-
4243169329
-
Vertebroplasty and kyphoplasty: Do fluoroscopy operators know about radiation dose, and should they want to know?
-
Seibert JA. Vertebroplasty and kyphoplasty: do fluoroscopy operators know about radiation dose, and should they want to know? Radiology. 2004 232(3):633-4.
-
(2004)
Radiology
, vol.232
, Issue.3
, pp. 633-634
-
-
Seibert, J.A.1
-
4
-
-
0027979920
-
Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy
-
1:STN:280:DyaK2c7ovFCktQ%3D%3D 8141070
-
A Gangi BA Kastler JL Dietemann 1994 Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy AJNR Am J Neuroradiol 15 1 83 6 1:STN:280:DyaK2c7ovFCktQ%3D%3D 8141070
-
(1994)
AJNR Am J Neuroradiol
, vol.15
, Issue.1
, pp. 83-6
-
-
Gangi, A.1
Kastler, B.A.2
Dietemann, J.L.3
-
5
-
-
0028883284
-
Radiation risk and exposure of radiologists and patients during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA)
-
J Karppinen T Parvianinen A Servomaa, et al. 1995 Radiation risk and exposure of radiologists and patients during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA) Radiat Prot Dosim 57 481 5
-
(1995)
Radiat Prot Dosim
, vol.57
, pp. 481-5
-
-
Karppinen, J.1
Parvianinen, T.2
Servomaa, A.3
-
6
-
-
0141563573
-
Occupational exposure from common fluoroscopic projections used in orthopaedic surgery
-
12954827
-
N Theocharopoulos K Perisinakis J Damilakis, et al. 2003 Occupational exposure from common fluoroscopic projections used in orthopaedic surgery J Bone Joint Surg Am 85 1698 703 12954827
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 1698-703
-
-
Theocharopoulos, N.1
Perisinakis, K.2
Damilakis, J.3
-
7
-
-
0027369899
-
Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control
-
1:STN:280:DyaK2c%2FjsF2ruw%3D%3D 10.1259/0007-1285-66-790-899 8220973
-
KE Goldstone IH Wright B Cohen 1993 Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control Br J Radiol 66 790 899 901 1:STN:280:DyaK2c%2FjsF2ruw%3D%3D 10.1259/0007-1285-66-790- 899 8220973
-
(1993)
Br J Radiol
, vol.66
, Issue.790
, pp. 899-901
-
-
Goldstone, K.E.1
Wright, I.H.2
Cohen, B.3
-
8
-
-
23944475576
-
Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: A prospective study
-
DOI 10.1097/01.brs.0000174121.48306.16
-
R Harstall PF Heini RL Mini R Orler 2005 Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study Spine 30 16 1893 8 10.1097/01.brs.0000174121.48306.16 16103862 (Pubitemid 41208837)
-
(2005)
Spine
, vol.30
, Issue.16
, pp. 1893-1898
-
-
Harstall, R.1
Heini, P.F.2
Mini, R.L.3
Orler, R.4
-
10
-
-
0029832236
-
Guidance with real-time CT fluoroscopy: Early clinical experience
-
1:STN:280:DyaK28zkslylsQ%3D%3D 8756943
-
K Katada R Kato H Anno, et al. 1996 Guidance with real-time CT fluoroscopy: early clinical experience Radiology 200 851 6 1:STN:280: DyaK28zkslylsQ%3D%3D 8756943
-
(1996)
Radiology
, vol.200
, pp. 851-6
-
-
Katada, K.1
Kato, R.2
Anno, H.3
-
11
-
-
33847666024
-
CT fluoroscopy shielding: Decreases in scattered radiation for the patient and operator
-
DOI 10.1097/01.RVI.0000244847.63204.5f, PII 0000251820061200000023
-
Z Neeman SA Dromi S Sarin BJ Wood 2006 CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator J Vasc Interv Radiol 17 1999 2004 10.1097/01.RVI.0000244847.63204.5F 17185699 (Pubitemid 46360685)
-
(2006)
Journal of Vascular and Interventional Radiology
, vol.17
, Issue.12
, pp. 1999-2004
-
-
Neeman, Z.1
Dromi, S.A.2
Sarin, S.3
Wood, B.J.4
-
12
-
-
0032849473
-
CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure
-
1:STN:280:DyaK1MvgslKluw%3D%3D 10478231
-
SG Silverman K Tuncali DF Adams RD Nawfel KH Zou PF Judy 1999 CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure Radiology 212 3 673 81 1:STN:280:DyaK1MvgslKluw%3D%3D 10478231
-
(1999)
Radiology
, vol.212
, Issue.3
, pp. 673-81
-
-
Silverman, S.G.1
Tuncali, K.2
Adams, D.F.3
Nawfel, R.D.4
Zou, K.H.5
Judy, P.F.6
-
13
-
-
0030801524
-
Vertebroplasties percutannées: Technique et indications
-
1:STN:280:DyaK2sznvFSlsQ%3D%3D 9303944
-
J Chiras C Depriester A Weill H Deramond 1997 Vertebroplasties percutannées: technique et indications J Neuroradiol 24 45 59 1:STN:280:DyaK2sznvFSlsQ%3D%3D 9303944
-
(1997)
J Neuroradiol
, vol.24
, pp. 45-59
-
-
Chiras, J.1
Depriester, C.2
Weill, A.3
Deramond, H.4
-
14
-
-
0034978126
-
CT fluoroscopy-guided interventional procedures: Techniques and radiation dose to radiologists
-
1:STN:280:DC%2BD3MzmsVOquw%3D%3D 11425990
-
EK Paulson DH Sheafor DS Enterline HP McAdams TT Yoshizumi 2001 CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists Radiology 220 1 161 7 1:STN:280:DC%2BD3MzmsVOquw%3D%3D 11425990
-
(2001)
Radiology
, vol.220
, Issue.1
, pp. 161-7
-
-
Paulson, E.K.1
Sheafor, D.H.2
Enterline, D.S.3
McAdams, H.P.4
Yoshizumi, T.T.5
-
15
-
-
0033770977
-
Effect of the learning process on procedure times and radiation exposure for CT fluoroscopy-guided percutaneous biopsy procedures
-
1:STN:280:DC%2BD3cvptVajuw%3D%3D 10.1016/S1051-0443(07)61367-0 11041482
-
D Gianfelice L Lepanto P Perreault C Chartrand-Lefebvre PC Milette 2000 Effect of the learning process on procedure times and radiation exposure for CT fluoroscopy-guided percutaneous biopsy procedures J Vasc Interv Radiol 11 9 1217 21 1:STN:280:DC%2BD3cvptVajuw%3D%3D 10.1016/S1051-0443(07)61367-0 11041482
-
(2000)
J Vasc Interv Radiol
, vol.11
, Issue.9
, pp. 1217-21
-
-
Gianfelice, D.1
Lepanto, L.2
Perreault, P.3
Chartrand-Lefebvre, C.4
Milette, P.C.5
-
17
-
-
11144355934
-
Radiation dose in vertebroplasty
-
DOI 10.1007/s00234-003-1156-0
-
A Mehdizade KO Lovblad KE Wilhelm T Somon SG Wetzel AD Kelekis H Yilmaz G Abdo JB Martin JM Viera DA Rüfenacht 2004 Radiation dose in vertebroplasty Neuroradiology 46 3 243 5 1:STN:280:DC%2BD2c7ktFGgtw%3D%3D 10.1007/s00234-003- 1156-0 14968269 (Pubitemid 38477396)
-
(2004)
Neuroradiology
, vol.46
, Issue.3
, pp. 243-245
-
-
Mehdizade, A.1
Lovblad, K.O.2
Wilhelm, K.E.3
Somon, T.4
Wetzel, S.G.5
Kelekis, A.D.6
Yilmaz, H.7
Abdo, G.8
Martin, J.B.9
Viera, J.M.10
Rufenacht, D.A.11
-
18
-
-
0038275749
-
Radiation dose to the operator during vertebroplasty: Prospective comparison of the use of 1-cc syringes versus an injection device
-
12812967
-
DF Kallmes E O SS Roy RG Piccolo WF Marx JK Lee ME Jensen 2003 Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device AJNR Am J Neuroradiol 24 6 1257 60 12812967
-
(2003)
AJNR Am J Neuroradiol
, vol.24
, Issue.6
, pp. 1257-60
-
-
Kallmes, D.F.1
Roy, S.S.2
Piccolo, R.G.3
Marx, W.F.4
Lee, J.K.5
Jensen, M.E.6
-
19
-
-
33750588368
-
Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: Methods and techniques
-
1:STN:280:DC%2BD283mt1WgtQ%3D%3D 16687529
-
AO Ortiz V Natarajan DR Gregorius S Pollack 2006 Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: methods and techniques AJNR Am J Neuroradiol 27 5 989 94 1:STN:280:DC%2BD283mt1WgtQ%3D%3D 16687529
-
(2006)
AJNR Am J Neuroradiol
, vol.27
, Issue.5
, pp. 989-94
-
-
Ortiz, A.O.1
Natarajan, V.2
Gregorius, D.R.3
Pollack, S.4
|