메뉴 건너뛰기




Volumn 33, Issue 8, 2002, Pages 723-727

Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CONTROLLED STUDY; FEMALE; FEMUR; GONAD; HAND; HUMAN; INTERMETHOD COMPARISON; INTRAMEDULLARY NAIL; INTRAMEDULLARY NAILING; LEG FRACTURE; MAJOR CLINICAL STUDY; MALE; OCCUPATIONAL EXPOSURE; OPERATION DURATION; PRIORITY JOURNAL; RADIATION EXPOSURE; RADIATION HAZARD; RADIATION SCATTERING; SURGEON; TIBIA;

EID: 0036788370     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0020-1383(02)00042-6     Document Type: Article
Times cited : (76)

References (20)
  • 1
    • 0023987998 scopus 로고
    • Friends of the earth. The response of the International Commission on Radiological Protection to calls for a reduction in the dose limits of radiation workers and members of the public
    • Friends of the earth. The response of the International Commission on Radiological Protection to calls for a reduction in the dose limits of radiation workers and members of the public. Int Rad Biol 1988;53:679-82.
    • (1988) Int Rad Biol , vol.53 , pp. 679-682
  • 2
    • 0010552002 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection, No. 60
    • International Commission on Radiological Protection. 1990 Recommendations of the International Commission on Radiological Protection, No. 60. ICRP 1990;21:72-9.
    • (1990) ICRP , vol.21 , pp. 72-79
  • 3
    • 0020684975 scopus 로고
    • Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures
    • Miller M.E., Davis M.L., MacClean C.R., Davis J.G., Smith B.L., Humphries J.R. Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. J. Bone Joint Surg. [Am.]. 65:1983;1-4.
    • (1983) J. Bone Joint Surg. [Am.] , vol.65 , pp. 1-4
    • Miller, M.E.1    Davis, M.L.2    MacClean, C.R.3    Davis, J.G.4    Smith, B.L.5    Humphries, J.R.6
  • 4
    • 0015364028 scopus 로고
    • Scattered radiation from a tissue-equivalent phantom for X-rays from 50 to 300 kVp
    • Trout E.D., Kelley J.P. Scattered radiation from a tissue-equivalent phantom for X-rays from 50 to 300 kVp. Radiology. 104:1972;161-169.
    • (1972) Radiology , vol.104 , pp. 161-169
    • Trout, E.D.1    Kelley, J.P.2
  • 5
    • 0019453564 scopus 로고
    • Central-axis depth dose data for diagnostic radiology
    • Harrison R.M. Central-axis depth dose data for diagnostic radiology. Phys. Med. Biol. 26:1981;657-670.
    • (1981) Phys. Med. Biol. , vol.26 , pp. 657-670
    • Harrison, R.M.1
  • 6
    • 0020659087 scopus 로고
    • Strahlungsmeesungen bei Verriegelungsnagelungen
    • Dosch J.C., Dupuis M., Beck G. Strahlungsmeesungen bei Verriegelungsnagelungen. Hefte Unfallheilk. 161:1983;36-38.
    • (1983) Hefte Unfallheilk , vol.161 , pp. 36-38
    • Dosch, J.C.1    Dupuis, M.2    Beck, G.3
  • 7
    • 0018841697 scopus 로고
    • Irradiation of the surgeon during pinning of femoral fractures
    • Giachino A.A., Cheng M. Irradiation of the surgeon during pinning of femoral fractures. J. Bone Joint Surg. [Br.]. 62:1980;227-229.
    • (1980) J. Bone Joint Surg. [Br.] , vol.62 , pp. 227-229
    • Giachino, A.A.1    Cheng, M.2
  • 8
    • 0026605655 scopus 로고
    • Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures
    • Coetzee J.C., Van Der Merwe E.J. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures. S. Afr. Med. J. 81:1992;312-314.
    • (1992) S. Afr. Med. J. , vol.81 , pp. 312-314
    • Coetzee, J.C.1    Van Der Merwe, E.J.2
  • 10
    • 0023761647 scopus 로고
    • Radiation dosage during AO locking femoral nailing
    • Sugarman ID, Adam I, Bunker TD. Radiation dosage during AO locking femoral nailing. Injury 1988;336-38.
    • (1988) Injury , pp. 336-338
    • Sugarman, I.D.1    Adam, I.2    Bunker, T.D.3
  • 11
    • 0023278854 scopus 로고
    • Radiation exposure to the surgeon during closed interlocking intramedullary nailing
    • Levin P.E., Schoen R.W. Jr., Browner B.D. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J. Bone Joint Surg. [Am.]. 69:1993;761-766.
    • (1993) J. Bone Joint Surg. [Am.] , vol.69 , pp. 761-766
    • Levin, P.E.1    Schoen R.W., Jr.2    Browner, B.D.3
  • 12
    • 0030433735 scopus 로고    scopus 로고
    • Complications following the use of the Marchetti flexible intramedullary nail
    • Hargreaves D.G., Warren P.J., Pereira J.A., Hollingdale J.P. Complications following the use of the Marchetti flexible intramedullary nail. Injury. 27:1996;735.
    • (1996) Injury , vol.27 , pp. 735
    • Hargreaves, D.G.1    Warren, P.J.2    Pereira, J.A.3    Hollingdale, J.P.4
  • 13
    • 0034292926 scopus 로고    scopus 로고
    • Closed intramedullary tibial nailing using the Marchetti-Vincenzi nail: Its use in closed and open fractures
    • De Smet K., Mostert A.K., De Witte J., De Brauwer V., Verdonk R. Closed intramedullary tibial nailing using the Marchetti-Vincenzi nail: its use in closed and open fractures. Injury. 31(8):2000;597-603.
    • (2000) Injury , vol.31 , Issue.8 , pp. 597-603
    • De Smet, K.1    Mostert, A.K.2    De Witte, J.3    De Brauwer, V.4    Verdonk, R.5
  • 15
    • 0030077848 scopus 로고    scopus 로고
    • Radiation dosage from use of the image intensifier in orthopaedic surgery
    • Lo N.N., Goh P.S., Khong K.S. Radiation dosage from use of the image intensifier in orthopaedic surgery. Singapore Med. J. 37:1996;69-71.
    • (1996) Singapore Med. J. , vol.37 , pp. 69-71
    • Lo, N.N.1    Goh, P.S.2    Khong, K.S.3
  • 16
    • 0023222981 scopus 로고
    • Interlocking medullary nails - Radiation doses in distal targeting
    • Skjeldal S., Backe S. Interlocking medullary nails - radiation doses in distal targeting. Arch. Orthop. Tr. Surg. 106:1987;179-181.
    • (1987) Arch. Orthop. Tr. Surg. , vol.106 , pp. 179-181
    • Skjeldal, S.1    Backe, S.2
  • 17
    • 0032127086 scopus 로고    scopus 로고
    • Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing
    • Muller L.P., Suffner J., Wenda K., Mohr W., Rommens P.M. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury. 29:1998;461-468.
    • (1998) Injury , vol.29 , pp. 461-468
    • Muller, L.P.1    Suffner, J.2    Wenda, K.3    Mohr, W.4    Rommens, P.M.5
  • 18
    • 0017763627 scopus 로고
    • Ionising radiation and the induction of clinically significant disease in the human thyroid gland
    • Maxon H.R., Thomas S.R., Saenger E.L., Buncher C.R., Kereiakes J.G. Ionising radiation and the induction of clinically significant disease in the human thyroid gland. Am J. Med. 63:1977;967-978.
    • (1977) Am J. Med. , vol.63 , pp. 967-978
    • Maxon, H.R.1    Thomas, S.R.2    Saenger, E.L.3    Buncher, C.R.4    Kereiakes, J.G.5
  • 19
    • 84960950194 scopus 로고
    • A clinical study of radiation cataracts and the relationship to dose
    • Merriam G.R. Jr., Focht E.F. A clinical study of radiation cataracts and the relationship to dose. Am. J. Roentgenol. 77:1957;759-785.
    • (1957) Am. J. Roentgenol. , vol.77 , pp. 759-785
    • Merriam G.R., Jr.1    Focht, E.F.2
  • 20
    • 0021343937 scopus 로고
    • Radiation exposure to an orthopaedic surgeon
    • Barry T.P. Radiation exposure to an orthopaedic surgeon. Clin. Orthop. 182:1984;160-164.
    • (1984) Clin. Orthop. , vol.182 , pp. 160-164
    • Barry, T.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.