-
1
-
-
33748192085
-
Multimodality in vivo imaging systems: Twice the power or Double the Trouble?
-
Cherry, S. R. (2006). “Multimodality in vivo imaging systems: Twice the power or Double the Trouble?” Annual Review Biomedical Engineering 8: 35-62.
-
(2006)
Annual Review Biomedical Engineering
, vol.8
, pp. 35-62
-
-
Cherry, S.R.1
-
2
-
-
52149092821
-
Multimodality molecular imaging
-
Tian, J., J. Bai, X. P. Yan, S. L. Bao, Y. H. Li, W. Liang & X. Yang (2008). “Multimodality molecular imaging”, IEEE Engineering in Medicine and Biology Magazine, 27(5): 48-57.
-
(2008)
IEEE Engineering in Medicine and Biology Magazine
, vol.27
, Issue.5
, pp. 48-57
-
-
Tian, J.1
Bai, J.2
Yan, X.P.3
Bao, S.L.4
Li, Y.H.5
Liang, W.6
Yang, X.7
-
3
-
-
40049100060
-
An outlook on the CT research and development
-
Wang, G., H. Y. Yu & B. D. Man (2008). “An outlook on the CT research and development”, Medical Physics 35(3): 1051-1064.
-
(2008)
Medical Physics
, vol.35
, Issue.3
, pp. 1051-1064
-
-
Wang, G.1
Yu, H.Y.2
Man, B.D.3
-
4
-
-
34250708569
-
Whole-Body optical imaging in animal models to assess cancer development and progression
-
Kaijzel, E. L., G. v. d. Pluijm & C. W. G. M. Löwik (2007). “Whole-Body optical imaging in animal models to assess cancer development and progression”, Clinical Cancer Research 13(12): 3490-3497.
-
(2007)
Clinical Cancer Research
, vol.13
, Issue.12
, pp. 3490-3497
-
-
Kaijzel, E.L.1
Pluijm, G.V.D.2
Löwik, C.W.G.M.3
-
6
-
-
21444441373
-
Looking and listening to light: The evolution of whole body photonic imaging
-
Ntziachristos, V., J. Ripoll, L. V. Wang & R. Weisslder (2005). “Looking and listening to light: The evolution of whole body photonic imaging”, Nature Biotechnology 23(3): 313-320.
-
(2005)
Nature Biotechnology
, vol.23
, Issue.3
, pp. 313-320
-
-
Ntziachristos, V.1
Ripoll, J.2
Wang, L.V.3
Weisslder, R.4
-
7
-
-
41649110649
-
Imaging in the era of molecular oncology
-
Weissleder, R. & M. J. Pittet (2008). “Imaging in the era of molecular oncology”, Nature 4(52): 580-589.
-
(2008)
Nature
, vol.4
, Issue.52
, pp. 580-589
-
-
Weissleder, R.1
Pittet, M.J.2
-
8
-
-
33750709693
-
Recent development in bioluminescence tomography
-
Wang, G., W. X. Cong, Y. Li, W. M. Han, K. Durairaj, X. Qian, H. Shen, M. Jiang, T. Zhou, J. Cheng, J. Tian, Y. Lü, H. Li & J. Luo (2006). “Recent development in bioluminescence tomography”, Current Medical Imaging Reviews 2: 453-457.
-
(2006)
Current Medical Imaging Reviews
, vol.2
, pp. 453-457
-
-
Wang, G.1
Cong, W.X.2
Li, Y.3
Han, W.M.4
Durairaj, K.5
Qian, X.6
Shen, H.7
Jiang, M.8
Zhou, T.9
Cheng, J.10
Tian, J.11
Lü, Y.12
Li, H.13
Luo, J.14
-
9
-
-
38449095359
-
Overview of bioluminescence tomography—a new molecular imaging modality
-
Wang, G., W. X. Cong, H. Shen, X. Qian, M. Henry & Y. Wang (2008). “Overview of bioluminescence tomography—a new molecular imaging modality”, Frontiers in Bioscience 13: 1281-1293.
-
(2008)
Frontiers in Bioscience
, vol.13
, pp. 1281-1293
-
-
Wang, G.1
Cong, W.X.2
Shen, H.3
Qian, X.4
Henry, M.5
Wang, Y.6
-
10
-
-
4043105065
-
Uniqueness theorems in bioluminescence tomography
-
Wang, G., Y. Li & M. Jiang (2004). “Uniqueness theorems in bioluminescence tomography”, Medical Physics 31(8): 2289-2299.
-
(2004)
Medical Physics
, vol.31
, Issue.8
, pp. 2289-2299
-
-
Wang, G.1
Li, Y.2
Jiang, M.3
-
11
-
-
24044542348
-
Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: A computer simulation feasibility study
-
Alexandrakis, G., F. R. Rannou & A. F. Chatziioannou (2005). “Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study”, Physics in Medicine Biology 50: 4225-4241.
-
(2005)
Physics in Medicine Biology
, vol.50
, pp. 4225-4241
-
-
Alexandrakis, G.1
Rannou, F.R.2
Chatziioannou, A.F.3
-
12
-
-
24944438742
-
Practical reconstruction method for bioluminescence tomography
-
Cong, W. X., G. Wang, D. Kumar, Y. Liu, M. Jiang, L. Wang, E. Hoffman, G. McLennan, P. McCray, J. Zabner & A. Cong (2005). “Practical reconstruction method for bioluminescence tomography”, Optics Express 13(18): 6756-6771.
-
(2005)
Optics Express
, vol.13
, Issue.18
, pp. 6756-6771
-
-
Cong, W.X.1
Wang, G.2
Kumar, D.3
Liu, Y.4
Jiang, M.5
Wang, L.6
Hoffman, E.7
McLennan, G.8
McCray, P.9
Zabner, J.10
Cong, A.11
-
13
-
-
33747799016
-
In vivo mouse studies with bioluminescence tomography
-
G. Wang, W. X. Cong, K. Durairaj, X. Qian, H. Shen, P. Sinn, E. Hoffman, G. McLennan & M. Henry (2006). “In vivo mouse studies with bioluminescence tomography”, Optics Express 14(17): 7801-7809.
-
(2006)
Optics Express
, vol.14
, Issue.17
, pp. 7801-7809
-
-
Wang, G.1
Cong, W.X.2
Durairaj, K.3
Qian, X.4
Shen, H.5
Sinn, P.6
Hoffman, E.7
McLennan, G.8
Henry, M.9
-
14
-
-
34047138989
-
MicroCT-guided bioluminescence tomography based on the adaptive finite element tomographic algorithm”
-
Lu, Y. J., J. Tian, W. X. Cong, G. Wang & D. Kumar (2006). “MicroCT-guided bioluminescence tomography based on the adaptive finite element tomographic algorithm”, Proceedings of the 28th IEEE EMBS Annual International Conference: 381-384.
-
(2006)
Proceedings of the 28Th IEEE EMBS Annual International Conference
, pp. 381-384
-
-
Lu, Y.J.1
Tian, J.2
Cong, W.X.3
Wang, G.4
Kumar, D.5
-
15
-
-
66449124999
-
Source reconstruction for spectrally-resolved bioluminescence tomography with sparse a priori information
-
Lu, Y. J., X. Q. Zhang, A. Douraghy, D. Stout, J. Tian, T. F. Chan & A. F. Chatziioannou (2009). “Source reconstruction for spectrally-resolved bioluminescence tomography with sparse a priori information”, Optics Express 17(10): 8062-8080.
-
(2009)
Optics Express
, vol.17
, Issue.10
, pp. 8062-8080
-
-
Lu, Y.J.1
Zhang, X.Q.2
Douraghy, A.3
Stout, D.4
Tian, J.5
Chan, T.F.6
Chatziioannou, A.F.7
-
16
-
-
67650296218
-
Registration of planar bioluminescence to magnetic resonance and X-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms
-
Beattie, B. J., A. D. Klose, C. H. Le, V. A. Longo, K. Dobrenkov, J. Vider, J. A. Koutcher & R. G. Blasberg (2009). “Registration of planar bioluminescence to magnetic resonance and X-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms”, Journal of Biomedical Optics 14(2): 024045.
-
(2009)
Journal of Biomedical Optics
, vol.14
, Issue.2
-
-
Beattie, B.J.1
Klose, A.D.2
Le, C.H.3
Longo, V.A.4
Dobrenkov, K.5
Vider, J.6
Koutcher, J.A.7
Blasberg, R.G.8
-
18
-
-
0021445363
-
Practical cone-beam algorithm
-
Feldkamp, L., L. Davis & J. Kress (1984). “Practical cone-beam algorithm”, Journal of the Optical Society of America A: Optics, Image Science and Vision 1(6): 612-619.
-
(1984)
Journal of the Optical Society of America A: Optics, Image Science and Vision
, vol.1
, Issue.6
, pp. 612-619
-
-
Feldkamp, L.1
Davis, L.2
Kress, J.3
-
19
-
-
39049121564
-
Quantitative bioluminescence tomography guided by diffuse optical tomography
-
Zhang, Q., L. Yin, Y. Tan, Z. Yuan & H. Jiang (2008). “Quantitative bioluminescence tomography guided by diffuse optical tomography”, Optics Express 16(3): 1481-1486.
-
(2008)
Optics Express
, vol.16
, Issue.3
, pp. 1481-1486
-
-
Zhang, Q.1
Yin, L.2
Tan, Y.3
Yuan, Z.4
Jiang, H.5
-
20
-
-
0032879583
-
Molecular imaging: Exploring the next frontier
-
Weissleder, R. (1999). “Molecular imaging: Exploring the next frontier”, Radiology 212(3): 609-614.
-
(1999)
Radiology
, vol.212
, Issue.3
, pp. 609-614
-
-
Weissleder, R.1
-
22
-
-
62149093158
-
BUSINESS OFFICE FEATURE: Life Science Technologies: Molecular Imaging”, No Swiss Army Approach
-
Calef, U. (2009). “BUSINESS OFFICE FEATURE: Life Science Technologies: Molecular Imaging”, No Swiss Army Approach Science 323(5919): 1364.
-
(2009)
Science
, vol.323
, Issue.5919
, pp. 1364
-
-
Calef, U.1
-
24
-
-
42149142396
-
MRI-Coupled spectrally-resolved fluorescence tomography for in vivo Imaging
-
Davis, S. C., et al. (2008). “MRI-Coupled spectrally-resolved fluorescence tomography for in vivo Imaging”, Multimodal Biomedical Imaging 6850: K8500-K8500.
-
(2008)
Multimodal Biomedical Imaging
, vol.6850
, pp. K8500-K8500
-
-
Davis, S.C.1
-
25
-
-
34047095433
-
Broad-spectrum multi-modality image registration: From PET, CT, and MRI to autoradiography, microscopy, and beyond
-
Zanzonico, P. B. (2006). “Broad-spectrum multi-modality image registration: From PET, CT, and MRI to autoradiography, microscopy, and beyond”, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 1-15: 6372-6376.
-
(2006)
28Th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 1-15
, pp. 6372-6376
-
-
Zanzonico, P.B.1
-
27
-
-
58149302701
-
Hybrid FMT-CT imaging of amyloid-beta plaques in a murine Alzheimer’s disease model
-
Hyde, D., et al. (2009). “Hybrid FMT-CT imaging of amyloid-beta plaques in a murine Alzheimer’s disease model”, Neuroimage 44(4): 1304-1311.
-
(2009)
Neuroimage
, vol.44
, Issue.4
, pp. 1304-1311
-
-
Hyde, D.1
-
28
-
-
62449222043
-
Multimodal imaging and treatment of bone metastasis
-
Kaijzel, E. L., et al. (2009). “Multimodal imaging and treatment of bone metastasis”, Clinical & Experimental Metastasis 26(4): 371-379.
-
(2009)
Clinical & Experimental Metastasis
, vol.26
, Issue.4
, pp. 371-379
-
-
Kaijzel, E.L.1
-
29
-
-
22944492084
-
Coregistered tomographic X-ray and optical breast imaging: Initial results
-
Zhang, Q., et al. (2005). “Coregistered tomographic X-ray and optical breast imaging: initial results”, Journal of Biomedical Optics 10(2).
-
(2005)
Journal of Biomedical Optics
, vol.10
, Issue.2
-
-
Zhang, Q.1
-
30
-
-
51749123138
-
Registration of 3D CT and 2D flat images of mouse via affine transformation
-
Xia, Z., et al. (2008). “Registration of 3D CT and 2D flat images of mouse via affine transformation”, IEEE Transactions on Information Technology in Biomedicine 12(5): 569-578.
-
(2008)
IEEE Transactions on Information Technology in Biomedicine
, vol.12
, Issue.5
, pp. 569-578
-
-
Xia, Z.1
-
31
-
-
37249026777
-
Registration of 3D FMT and CT images of mouse via affine transformation with Bayesian iterative closest points
-
Zheng, X., et al. (2007). “Registration of 3D FMT and CT images of mouse via affine transformation with Bayesian iterative closest points”, Advances in Neural Networks Proceedings 4492: 1140-1149.
-
(2007)
Advances in Neural Networks Proceedings
, vol.4492
, pp. 1140-1149
-
-
Zheng, X.1
-
32
-
-
71449083364
-
Registration of 3D FMT and CT images of mouse via affine transformation using Sequential Monte Carlo
-
Xia, Z., et al. (2007). “Registration of 3D FMT and CT images of mouse via affine transformation using Sequential Monte Carlo”, Computational Models for Life Sciences 952: 48-56.
-
(2007)
Computational Models for Life Sciences
, vol.952
, pp. 48-56
-
-
Xia, Z.1
-
33
-
-
57849131258
-
FPGA Electronics for OPET: A dual-modality optical and positron emission tomography
-
Douraghy, A., et al. (2008). “FPGA Electronics for OPET: A dual-modality optical and positron emission tomography”, IEEE Transactions on Nuclear Science 55(5): 2541-2545.
-
(2008)
IEEE Transactions on Nuclear Science
, vol.55
, Issue.5
, pp. 2541-2545
-
-
Douraghy, A.1
-
34
-
-
0035103741
-
Medical image registration
-
Hill, D. L., P. G. Batchelor, M. Holden, et al. (2001). “Medical image registration”, Physics in Medicine and Biology 46(3): R1-45.
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.3
, pp. R1-45
-
-
Hill, D.L.1
Batchelor, P.G.2
Holden, M.3
-
35
-
-
0035739242
-
Automated CT marker segmentation for image registration in radionuclide therapy
-
Papavasileiou, P., G. D. Flux, M. A. Flower, et al. (2001). “Automated CT marker segmentation for image registration in radionuclide therapy”, Physics in Medicine and Biology 46(12) N269-279.
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.12
, pp. N269-N279
-
-
Papavasileiou, P.1
Flux, G.D.2
Flower, M.A.3
-
36
-
-
0032008619
-
A survey of medical image registration
-
Maintz, J. B. & M. A. Viergever (1998). “A survey of medical image registration”, Medical Image Analysis 2(1): 1-36.
-
(1998)
Medical Image Analysis
, vol.2
, Issue.1
, pp. 1-36
-
-
Maintz, J.B.1
Viergever, M.A.2
-
37
-
-
0024555624
-
A reference system for neuroanatomical localization on functional reconstructed cerebral images
-
Wilson, M. W. & J. M. Mountz (1989). “A reference system for neuroanatomical localization on functional reconstructed cerebral images”, Journal of Computer Assisted Tomography 13(1): 174-178.
-
(1989)
Journal of Computer Assisted Tomography
, vol.13
, Issue.1
, pp. 174-178
-
-
Wilson, M.W.1
Mountz, J.M.2
-
38
-
-
0023639789
-
Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors
-
Schad, L. R., R. Boesecke, W. Schlege, et al. (1987). “Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors”, Journal of Computer Assisted Tomography 11(6): 948-954.
-
(1987)
Journal of Computer Assisted Tomography
, vol.11
, Issue.6
, pp. 948-954
-
-
Schad, L.R.1
Boesecke, R.2
Schlege, W.3
-
39
-
-
0023212697
-
Computed imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses
-
Apuzzo, M. L., P. T. Chandrasoma, D. Cohen, et al. (1987). “Computed imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses”, Neurosurgery 20(6): 930-937.
-
(1987)
Neurosurgery
, vol.20
, Issue.6
, pp. 930-937
-
-
Apuzzo, M.L.1
Chandrasoma, P.T.2
Cohen, D.3
-
40
-
-
0025689391
-
Program for PET image alignment: Effects on calculated differences in cerebral metabolic rates for glucose
-
Phillips, R. L., E. D. London, J. M. Links, et al. (1990). “Program for PET image alignment: effects on calculated differences in cerebral metabolic rates for glucose”, Journal of Nuclear Medicine 31(12): 2052-2057.
-
(1990)
Journal of Nuclear Medicine
, vol.31
, Issue.12
, pp. 2052-2057
-
-
Phillips, R.L.1
London, E.D.2
Links, J.M.3
-
41
-
-
0025216840
-
Multimodality imaging of brain structures for stereotactic surgery
-
Zhang, J., M. F. Levesque, C. L. Wilson, et al. (1990). “Multimodality imaging of brain structures for stereotactic surgery”, Radiology 175(2): 435-441.
-
(1990)
Radiology
, vol.175
, Issue.2
, pp. 435-441
-
-
Zhang, J.1
Levesque, M.F.2
Wilson, C.L.3
-
42
-
-
33744816221
-
Learning based non-rigid multi-modal image registration using Kullback-Leibler divergence”, Medical Image Computing and
-
Guetter, C., C. Xu, F. Sauer, et al. (2005). “Learning based non-rigid multi-modal image registration using Kullback-Leibler divergence”, Medical Image Computing and Computer-Assisted Intervention, palm Springs, CA, 3750(2): 255-262.
-
(2005)
Computer-Assisted Intervention, Palm Springs, CA
, vol.3750
, Issue.2
, pp. 255-262
-
-
Guetter, C.1
Xu, C.2
Sauer, F.3
-
43
-
-
79551689248
-
Registration of cardiac SPECT/CT data through weighted intensity co-occurrence priors
-
Guetter, C, M. Wacker & C. Xu (2007). “Registration of cardiac SPECT/CT data through weighted intensity co-occurrence priors”, Medical Image Computing and Computer-Assisted Intervention, Brisbane, Australia: 725-733.
-
(2007)
Medical Image Computing and Computer-Assisted Intervention, Brisbane, Australia
, pp. 725-733
-
-
Guetter, C.1
Wacker, M.2
Xu, C.3
-
44
-
-
52949153932
-
Feature-based rectal contour propagation from planning CT to cone beam CT
-
Xie, Y., M. Chao, P. Lee, et al. (2008). “Feature-based rectal contour propagation from planning CT to cone beam CT”, Medical Physics 35(10): 4450-4459.
-
(2008)
Medical Physics
, vol.35
, Issue.10
, pp. 4450-4459
-
-
Xie, Y.1
Chao, M.2
Lee, P.3
-
45
-
-
67649532160
-
Tissue feature-based and segmented deformable image registration for improved modeling of the shear movement of the lungs
-
Xie, Y., M. Chao & L. Xing (2009). “Tissue feature-based and segmented deformable image registration for improved modeling of the shear movement of the lungs”, International Journal of Radiation Oncology Biology Physics 74(4): 1256-1265.
-
(2009)
International Journal of Radiation Oncology Biology Physics
, vol.74
, Issue.4
, pp. 1256-1265
-
-
Xie, Y.1
Chao, M.2
Xing, L.3
-
46
-
-
23744491662
-
A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images
-
Jan, M. L., K. S. Chuang, G. W. Chen, et al. (2005). “A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images”, IEEE Transaction on Medical Imaging 24(7): 886-893.
-
(2005)
IEEE Transaction on Medical Imaging
, vol.24
, Issue.7
, pp. 886-893
-
-
Jan, M.L.1
Chuang, K.S.2
Chen, G.W.3
-
47
-
-
0142148117
-
Development of external fiducial markers for image registration in small animal SPECT/CT
-
Sakdinawat, A. E., K. Iwata & A. B. Hwang (2002). “Development of external fiducial markers for image registration in small animal SPECT/CT”, IEEE Nuclear Science Symposium, Conference Record, Norflok, VA,1-3: 842-845.
-
(2002)
IEEE Nuclear Science Symposium, Conference Record, Norflok, VA
, vol.1-3
, pp. 842-845
-
-
Sakdinawat, A.E.1
Iwata, K.2
Hwang, A.B.3
-
48
-
-
33645367215
-
On the spatial statistics of optical flow
-
Beijing, China, Proceedings, 1&2
-
Roth, S. & M. Black (2005). On the spatial statistics of optical flow. 10th International Journal of Computer Vision, Beijing, China, Proceedings, 1&2: 42-49.
-
(2005)
10Th International Journal of Computer Vision
, pp. 42-49
-
-
Roth, S.1
Black, M.2
-
49
-
-
84947739847
-
Multi-modal volume registration using joint intensity distributions
-
Leventon, M. & E. Grimson (1998). “Multi-modal volume registration using joint intensity distributions”, Medical Image Computing and Computer-Assisted Intervention, Cambridge, Massachusetts, 1496: 1057-1066.
-
(1998)
Medical Image Computing and Computer-Assisted Intervention, Cambridge, Massachusetts
, vol.1496
, pp. 1057-1066
-
-
Leventon, M.1
Grimson, E.2
-
50
-
-
84944056680
-
-
Medical Image Computing and Computer-Assisted Intervention, Tokyo, Japan
-
Chung, A. C. S., W. M. Wells, A. Norbash, et al. (2002). “Multi-modal image registration by minimising Kullback-Leibler distance”, Medical Image Computing and Computer-Assisted Intervention, Tokyo, Japan, 2489: 525-532.
-
(2002)
Multi-Modal Image Registration by Minimising Kullback-Leibler Distance
, pp. 525-532
-
-
Chung, A.C.S.1
Wells, W.M.2
Norbash, A.3
-
51
-
-
20344386222
-
“Multiresolution image registration based on Kullback-Leibler distance”, Medical Image Computing and Computer-Assisted Intervention, St
-
Gan, R., J. Wu, A. C. S. Chung, et al. (2004). “Multiresolution image registration based on Kullback-Leibler distance”, Medical Image Computing and Computer-Assisted Intervention, St. Malo, France, 3216: 599-606.
-
(2004)
Malo, France
, vol.3216
, pp. 599-606
-
-
Gan, R.1
Wu, J.2
Chung, A.C.S.3
-
52
-
-
33845577818
-
-
New York, NY
-
Cremers, D., C. Guetter & C. Xu (2006). “Nonparametric priors on the space of joint intensity distributions for non-rigid multi-modal image registration”, Computer Vision & Pattern Recognition, New York, NY, 2: 1777-1783.
-
(2006)
Nonparametric Priors on the Space of Joint Intensity Distributions for Non-Rigid Multi-Modal Image registration”, Computer Vision & Pattern Recognition
, vol.2
, pp. 1777-1783
-
-
Cremers, D.1
Guetter, C.2
Xu, C.3
-
53
-
-
3042535216
-
Distinctive Image Features from Scale-Invariant Keypoints
-
Lowe, D. G. (2004). “Distinctive Image Features from Scale-Invariant Keypoints”, International Jounal of Computer Vision 60 (2): 91-110.
-
(2004)
International Jounal of Computer Vision
, vol.60
, Issue.2
, pp. 91-110
-
-
Lowe, D.G.1
-
54
-
-
0033284915
-
Object Recognition from Local Scale-Invariant Features
-
Lowe, D. G. (1999). “Object Recognition from Local Scale-Invariant Features”, Proceeding of the International Conference on Computer Vision, Corfu, Greece, 2: 1150.
-
(1999)
Proceeding of the International Conference on Computer Vision, Corfu, Greece
, vol.2
, pp. 1150
-
-
Lowe, D.G.1
-
55
-
-
52949153932
-
Feature-Based Rectal Contour Propagation from Planning CT to Cone Beam CT
-
Xie, Y., M. Chao, P. Lee, et al. (2008). “Feature-Based Rectal Contour Propagation from Planning CT to Cone Beam CT”, Medical Physics 35(10): 4450-4459.
-
(2008)
Medical Physics
, vol.35
, Issue.10
, pp. 4450-4459
-
-
Xie, Y.1
Chao, M.2
Lee, P.3
-
57
-
-
33749394280
-
A general learning framework for non-rigid image registration”, Medical Imaging and Augmented Reality
-
Wu, G., F. Qi & D. Shen (2006). “A general learning framework for non-rigid image registration”, Medical Imaging and Augmented Reality, Lecture Notes in Computer Science, 4091: 219-227.
-
(2006)
Lecture Notes in Computer Science
, vol.4091
, pp. 219-227
-
-
Wu, G.1
Qi, F.2
Shen, D.3
-
59
-
-
9244236565
-
Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: A deformable registration and validation study
-
Lian, J., L. Xing, S. Hunjan, et al. (2004). “Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: A deformable registration and validation study”, Medical Physics 31(11): 3087-3094.
-
(2004)
Medical Physics
, vol.31
, Issue.11
, pp. 3087-3094
-
-
Lian, J.1
Xing, L.2
Hunjan, S.3
|