1
-
-
0027411978
-
MRI-guided noninvasive ultrasound surgery
-
Hynynen K, Darkazanli A, Unger E, Schenck JF: MRI-guided noninvasive ultrasound surgery. Med Phys. 1993, 20: 107-15. 10.1118/1.597093.
-
(1993)
Med Phys
, vol.20
, pp. 107-115
-
-
Hynynen, K.1
Darkazanli, A.2
Unger, E.3
Schenck, J.F.4
-
2
-
-
27144503075
-
The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population
-
Illing RO, Kennedy JE, Wu F, ter Haar GR, Protheroe AS, Friend PJ, Gleeson FV, Cranston DW, Phillips RR, Middleton MR: The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population. Br J Cancer. 2005, 93: 890-5. 10.1038/sj.bjc.6602803.
-
(2005)
Br J Cancer
, vol.93
, pp. 890-895
-
-
Illing, R.O.1
Kennedy, J.E.2
Wu, F.3
ter Haar, G.R.4
Protheroe, A.S.5
Friend, P.J.6
Gleeson, F.V.7
Cranston, D.W.8
Phillips, R.R.9
Middleton, M.R.10
-
3
-
-
16844382450
-
High-intensity focused ultrasound in the treatment of solid tumours
-
Kennedy JE: High-intensity focused ultrasound in the treatment of solid tumours. Nat Rev Cancer. 2005, 5: 321-7. 10.1038/nrc1591.
-
(2005)
Nat Rev Cancer
, vol.5
, pp. 321-327
-
-
Kennedy, J.E.1
-
4
-
-
21044451307
-
Extracorporeal high intensity focused ultrasound treatment for patients with breast cancer
-
Wu F, Wang ZB, Zhu H, Chen WZ, Zou JZ, Bai J, Li KQ, Jin CB, Xie FL, Su HB: Extracorporeal high intensity focused ultrasound treatment for patients with breast cancer. Breast Cancer Res Treat. 2005, 92: 51-60. 10.1007/s10549-004-5778-7.
-
(2005)
Breast Cancer Res Treat
, vol.92
, pp. 51-60
-
-
Wu, F.1
Wang, Z.B.2
Zhu, H.3
Chen, W.Z.4
Zou, J.Z.5
Bai, J.6
Li, K.Q.7
Jin, C.B.8
Xie, F.L.9
Su, H.B.10
-
5
-
-
33947155852
-
High intensity focused ultrasound: past, present and future
-
ter Haar G, Coussios C: High intensity focused ultrasound: past, present and future. Int J Hyperthermia. 2007, 23: 85-7. 10.1080/02656730601185924.
-
(2007)
Int J Hyperthermia
, vol.23
, pp. 85-87
-
-
ter Haar, G.1
Coussios, C.2
-
6
-
-
44449158246
-
Magnetic resonance imaging-guided focused ultrasound ablation of uterine fibroids: early clinical experience
-
Mikami K, Murakami T, Okada A, Osuga K, Tomoda K, Nakamura H: Magnetic resonance imaging-guided focused ultrasound ablation of uterine fibroids: early clinical experience. Radiat Med. 2008, 26: 198-205. 10.1007/s11604-007-0215-6.
-
(2008)
Radiat Med
, vol.26
, pp. 198-205
-
-
Mikami, K.1
Murakami, T.2
Okada, A.3
Osuga, K.4
Tomoda, K.5
Nakamura, H.6
-
7
-
-
0242523861
-
Preliminary experience using high intensity focused ultrasound for the treatment of patients with advanced stage renal malignancy
-
Wu F, Wang ZB, Chen WZ, Bai J, Zhu H, Qiao TY: Preliminary experience using high intensity focused ultrasound for the treatment of patients with advanced stage renal malignancy. J Urol. 2003, 170: 2237-40. 10.1097/01.ju.0000097123.34790.70.
-
(2003)
J Urol
, vol.170
, pp. 2237-2240
-
-
Wu, F.1
Wang, Z.B.2
Chen, W.Z.3
Bai, J.4
Zhu, H.5
Qiao, T.Y.6
-
8
-
-
1642601566
-
High-intensity focused ultrasound for the treatment of liver tumours
-
Kennedy JE, Wu F, ter Haar GR, Gleeson FV, Phillips RR, Middleton MR, Cranston D: High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics. 2004, 42: 931-5. 10.1016/j.ultras.2004.01.089.
-
(2004)
Ultrasonics
, vol.42
, pp. 931-935
-
-
Kennedy, J.E.1
Wu, F.2
ter Haar, G.R.3
Gleeson, F.V.4
Phillips, R.R.5
Middleton, M.R.6
Cranston, D.7
-
9
-
-
11144354898
-
Extracorporeal high intensity focused ultrasound ablation in the treatment of 1,038 patients with solid carcinomas in China: an overview
-
Wu F, Wang ZB, Chen WZ, Wang W, Gui Y, Zhang M, Zheng G, Zhou Y, Xu G, Li M, Zhang C, Ye H, Feng R: Extracorporeal high intensity focused ultrasound ablation in the treatment of 1,038 patients with solid carcinomas in China: an overview. Ultrason Sonochem. 2004, 11: 149-54. 10.1016/j.ultsonch.2004.01.011.
-
(2004)
Ultrason Sonochem
, vol.11
, pp. 149-154
-
-
Wu, F.1
Wang, Z.B.2
Chen, W.Z.3
Wang, W.4
Gui, Y.5
Zhang, M.6
Zheng, G.7
Zhou, Y.8
Xu, G.9
Li, M.10
Zhang, C.11
Ye, H.12
Feng, R.13
-
10
-
-
0026090542
-
The threshold for thermally significant cavitation in dog's thigh muscle in vivo
-
Hynynen K: The threshold for thermally significant cavitation in dog's thigh muscle in vivo. Ultrasound Med Biol. 1991, 17: 157-69. 10.1016/0301-5629(91)90123-E.
-
(1991)
Ultrasound Med Biol
, vol.17
, pp. 157-169
-
-
Hynynen, K.1
-
11
-
-
0035673103
-
Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material
-
Holt RG, Roy RA: Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. Ultrasound Med Biol. 2001, 27: 1399-412. 10.1016/S0301-5629(01)00438-0.
-
(2001)
Ultrasound Med Biol
, vol.27
, pp. 1399-1412
-
-
Holt, R.G.1
Roy, R.A.2
-
12
-
-
0037458224
-
MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh
-
Sokka SD, King R, Hynynen K: MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh. Phys Med Biol. 2003, 48: 223-41. 10.1088/0031-9155/48/2/306.
-
(2003)
Phys Med Biol
, vol.48
, pp. 223-241
-
-
Sokka, S.D.1
King, R.2
Hynynen, K.3
-
13
-
-
1042275628
-
Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies
-
Melodelima D, Chapelon JY, Theillere Y, Cathignol D: Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies. Ultrasound Med Biol. 2004, 30: 103-11. 10.1016/j.ultrasmedbio.2003.09.005.
-
(2004)
Ultrasound Med Biol
, vol.30
, pp. 103-111
-
-
Melodelima, D.1
Chapelon, J.Y.2
Theillere, Y.3
Cathignol, D.4
-
15
-
-
39049103980
-
Applications of acoustics and cavitation to noninvasive therapy and drug delivery
-
Coussios CC, Roy RA: Applications of acoustics and cavitation to noninvasive therapy and drug delivery. Annu Rev Fluid Mech. 2008, 40: 395-420. 10.1146/annurev.fluid.40.111406.102116.
-
(2008)
Annu Rev Fluid Mech
, vol.40
, pp. 395-420
-
-
Coussios, C.C.1
Roy, R.A.2
-
16
-
-
62849091749
-
Temporal and spatial detection of HIFU-induced inertial and hot-vapor cavitation with a diagnostic ultrasound system
-
Farny CH, Holt RG, Roy RA: Temporal and spatial detection of HIFU-induced inertial and hot-vapor cavitation with a diagnostic ultrasound system. Ultrasound Med Biol. 2009, 35: 603-15. 10.1016/j.ultrasmedbio.2008.09.025.
-
(2009)
Ultrasound Med Biol
, vol.35
, pp. 603-615
-
-
Farny, C.H.1
Holt, R.G.2
Roy, R.A.3
-
17
-
-
76649128713
-
The correlation between bubble-enhanced HIFU heating and cavitation power
-
Farny CH, Glynn Holt R, Roy RA: The correlation between bubble-enhanced HIFU heating and cavitation power. IEEE Trans Biomed Eng. 2010, 57: 175-84.
-
(2010)
IEEE Trans Biomed Eng
, vol.57
, pp. 175-184
-
-
Farny, C.H.1
Glynn Holt, R.2
Roy, R.A.3
-
18
-
-
0036815531
-
Spontaneous homogeneous nucleation, inertial cavitation and the safety of diagnostic ultrasound
-
Church CC: Spontaneous homogeneous nucleation, inertial cavitation and the safety of diagnostic ultrasound. Ultrasound Med Biol. 2002, 28: 1349-64. 10.1016/S0301-5629(02)00579-3.
-
(2002)
Ultrasound Med Biol
, vol.28
, pp. 1349-1364
-
-
Church, C.C.1
-
19
-
-
28844454163
-
Investigation of intensity thresholds for ultrasound tissue erosion
-
Xu Z, Fowlkes JB, Ludomirsky A, Cain CA: Investigation of intensity thresholds for ultrasound tissue erosion. Ultrasound Med Biol. 2005, 31: 1673-82. 10.1016/j.ultrasmedbio.2005.07.016.
-
(2005)
Ultrasound Med Biol
, vol.31
, pp. 1673-1682
-
-
Xu, Z.1
Fowlkes, J.B.2
Ludomirsky, A.3
Cain, C.A.4
-
20
-
-
74849103216
-
Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound
-
Canney MS, Khokhlova VA, Bessonova OV, Bailey MR, Crum LA: Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound. Ultrasound Med Biol. 2010, 36: 250-67. 10.1016/j.ultrasmedbio.2009.09.010.
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 250-267
-
-
Canney, M.S.1
Khokhlova, V.A.2
Bessonova, O.V.3
Bailey, M.R.4
Crum, L.A.5
-
21
-
-
33644661412
-
Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom
-
Khokhlova VA, Bailey MR, Reed JA, Cunitz BW, Kaczkowski PJ, Crum LA: Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom. J Acoust Soc Am. 2006, 119: 1834-48. 10.1121/1.2161440.
-
(2006)
J Acoust Soc Am
, vol.119
, pp. 1834-1848
-
-
Khokhlova, V.A.1
Bailey, M.R.2
Reed, J.A.3
Cunitz, B.W.4
Kaczkowski, P.J.5
Crum, L.A.6
-
22
-
-
64649085548
-
Magnetic resonance imaging of boiling induced by high intensity focused ultrasound
-
Khokhlova TD, Canney MS, Lee D, Marro KI, Crum LA, Khokhlova VA, Bailey MR: Magnetic resonance imaging of boiling induced by high intensity focused ultrasound. J Acoust Soc Am. 2009, 125: 2420-31. 10.1121/1.3081393.
-
(2009)
J Acoust Soc Am
, vol.125
, pp. 2420-2431
-
-
Khokhlova, T.D.1
Canney, M.S.2
Lee, D.3
Marro, K.I.4
Crum, L.A.5
Khokhlova, V.A.6
Bailey, M.R.7
-
23
-
-
33745586048
-
Contrast-agent-enhanced ultrasound thermal ablation
-
Tung YS, Liu HL, Wu CC, Ju KC, Chen WS, Lin WL: Contrast-agent-enhanced ultrasound thermal ablation. Ultrasound Med Biol. 2006, 32: 1103-10. 10.1016/j.ultrasmedbio.2006.04.005.
-
(2006)
Ultrasound Med Biol
, vol.32
, pp. 1103-1110
-
-
Tung, Y.S.1
Liu, H.L.2
Wu, C.C.3
Ju, K.C.4
Chen, W.S.5
Lin, W.L.6
-
24
-
-
34047209031
-
Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo
-
Luo W, Zhou X, Ren X, Zheng M, Zhang J, He G: Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo. J Ultrasound Med. 2007, 26: 469-76.
-
(2007)
J Ultrasound Med
, vol.26
, pp. 469-476
-
-
Luo, W.1
Zhou, X.2
Ren, X.3
Zheng, M.4
Zhang, J.5
He, G.6
-
25
-
-
51649085740
-
Ablation of high intensity focused ultrasound combined with SonoVue on rabbit VX2 liver tumors: assessment with conventional gray-scale US, conventional color/power Doppler US, contrast-enhanced color Doppler US, and contrast-enhanced pulse-inversion harmonic US
-
Luo W, Zhou X, He G, Li Q, Zheng X, Fan Z, Liu Q, Yu M, Han Z, Zhang J, Qian Y: Ablation of high intensity focused ultrasound combined with SonoVue on rabbit VX2 liver tumors: assessment with conventional gray-scale US, conventional color/power Doppler US, contrast-enhanced color Doppler US, and contrast-enhanced pulse-inversion harmonic US. Ann Surg Oncol. 2008, 15: 2943-53. 10.1245/s10434-008-0032-x.
-
(2008)
Ann Surg Oncol
, vol.15
, pp. 2943-2953
-
-
Luo, W.1
Zhou, X.2
He, G.3
Li, Q.4
Zheng, X.5
Fan, Z.6
Liu, Q.7
Yu, M.8
Han, Z.9
Zhang, J.10
Qian, Y.11
-
26
-
-
33846973649
-
Acoustic techniques for assessing the Optison destruction threshold
-
Porter TM, Smith DA, Holland CK: Acoustic techniques for assessing the Optison destruction threshold. J Ultrasound Med. 2006, 25: 1519-29.
-
(2006)
J Ultrasound Med
, vol.25
, pp. 1519-1529
-
-
Porter, T.M.1
Smith, D.A.2
Holland, C.K.3
-
27
-
-
35348919991
-
Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery
-
Ferrara K, Pollard R, Borden M: Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery. Annu Rev Biomed Eng. 2007, 9: 415-47. 10.1146/annurev.bioeng.8.061505.095852.
-
(2007)
Annu Rev Biomed Eng
, vol.9
, pp. 415-447
-
-
Ferrara, K.1
Pollard, R.2
Borden, M.3
-
28
-
-
25444496930
-
Nucleating cavitation from laser-illuminated nano-particles
-
Farny CH, Wu TM, Holt RG, Murray TW, Roy RA: Nucleating cavitation from laser-illuminated nano-particles. Acoust Res Lett Onl. 2005, 6: 138-43. 10.1121/1.1897823.
-
(2005)
Acoust Res Lett Onl
, vol.6
, pp. 138-143
-
-
Farny, C.H.1
Wu, T.M.2
Holt, R.G.3
Murray, T.W.4
Roy, R.A.5
-
29
-
-
77958154455
-
An in vitro study of a phase-shift nanoemulsion: a potential nucleation agent for bubble-enhanced HIFU tumor ablation
-
Zhang P, Porter T: An in vitro study of a phase-shift nanoemulsion: a potential nucleation agent for bubble-enhanced HIFU tumor ablation. Ultrasound Med Biol. 2010, 36: 1856-66. 10.1016/j.ultrasmedbio.2010.07.001.
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 1856-1866
-
-
Zhang, P.1
Porter, T.2
-
30
-
-
80052195856
-
Formulation and acoustic studies of a new phase-shift agent for diagnostic and therapeutic ultrasound
-
Sheeran PS, Luois S, Dayton PA, Matsunaga TO: Formulation and acoustic studies of a new phase-shift agent for diagnostic and therapeutic ultrasound. Langmuir. 2011, 27: 10412-20. 10.1021/la2013705.
-
(2011)
Langmuir
, vol.27
, pp. 10412-10420
-
-
Sheeran, P.S.1
Luois, S.2
Dayton, P.A.3
Matsunaga, T.O.4
-
31
-
-
68549099545
-
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
-
Rapoport NY, Kennedy AM, Shea JE, Scaife CL, Nam KH: Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles. J Control Release. 2009, 138: 268-76. 10.1016/j.jconrel.2009.05.026.
-
(2009)
J Control Release
, vol.138
, pp. 268-276
-
-
Rapoport, N.Y.1
Kennedy, A.M.2
Shea, J.E.3
Scaife, C.L.4
Nam, K.H.5
-
32
-
-
34548543375
-
Anomalous pH dependent stability behavior of surfactant-free nonpolar oil drops in aqueous electrolyte solutions
-
Clasohm LY, Vakarelski IU, Dagastine RR, Chan DY, Stevens GW, Grieser F: Anomalous pH dependent stability behavior of surfactant-free nonpolar oil drops in aqueous electrolyte solutions. Langmuir. 2007, 23: 9335-40. 10.1021/la701568r.
-
(2007)
Langmuir
, vol.23
, pp. 9335-9340
-
-
Clasohm, L.Y.1
Vakarelski, I.U.2
Dagastine, R.R.3
Chan, D.Y.4
Stevens, G.W.5
Grieser, F.6
-
33
-
-
0001364228
-
Tensions des vapeurs; nouvelle relation entre les tensions et les temperatures
-
Antoine C: Tensions des vapeurs; nouvelle relation entre les tensions et les temperatures. Comptes Rendus des Seances de l'Academie des Sci. 1888, 107: 681-4.
-
(1888)
Comptes Rendus des Seances de l'Academie des Sci
, vol.107
, pp. 681-684
-
-
Antoine, C.1
-
34
-
-
0024755521
-
To estimate vapor pressure easily: Antoine coefficients relate vapor pressure to temperature for almost 700 major organic compounds
-
Yaws CL, Yang HC: To estimate vapor pressure easily: Antoine coefficients relate vapor pressure to temperature for almost 700 major organic compounds. Hydrocarb Process. 1989, 68: 65-8.
-
(1989)
Hydrocarb Process
, vol.68
, pp. 65-68
-
-
Yaws, C.L.1
Yang, H.C.2
-
35
-
-
0034281706
-
Acoustic droplet vaporization for therapeutic and diagnostic applications
-
Kripfgans OD, Fowlkes JB, Miller DL, Eldevik OP, Carson PL: Acoustic droplet vaporization for therapeutic and diagnostic applications. Ultrasound Med Biol. 2000, 26: 1177-89. 10.1016/S0301-5629(00)00262-3.
-
(2000)
Ultrasound Med Biol
, vol.26
, pp. 1177-1189
-
-
Kripfgans, O.D.1
Fowlkes, J.B.2
Miller, D.L.3
Eldevik, O.P.4
Carson, P.L.5
-
36
-
-
0033082026
-
Dodecafluoropentane ultrasonic contrast enhancement in carotid diagnosis: preliminary results
-
Gahn G, Ackerman RH, Candia MR, Barrett KM, Lev MH, Huang AY: Dodecafluoropentane ultrasonic contrast enhancement in carotid diagnosis: preliminary results. J Ultrasound Med. 1999, 18: 101-8.
-
(1999)
J Ultrasound Med
, vol.18
, pp. 101-108
-
-
Gahn, G.1
Ackerman, R.H.2
Candia, M.R.3
Barrett, K.M.4
Lev, M.H.5
Huang, A.Y.6
-
37
-
-
0034000453
-
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
-
Maeda H, Wu J, Sawa T, Matsumura Y, Hori K: Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review. J Control Release. 2000, 65: 271-84. 10.1016/S0168-3659(99)00248-5.
-
(2000)
J Control Release
, vol.65
, pp. 271-284
-
-
Maeda, H.1
Wu, J.2
Sawa, T.3
Matsumura, Y.4
Hori, K.5
-
38
-
-
34249820576
-
Multifunctional nanocarriers
-
Torchilin VP: Multifunctional nanocarriers. Adv Drug Deliv Rev. 2006, 58: 1532-55. 10.1016/j.addr.2006.09.009.
-
(2006)
Adv Drug Deliv Rev
, vol.58
, pp. 1532-1555
-
-
Torchilin, V.P.1
-
39
-
-
26444550641
-
Gel phantom for use in high-intensity focused ultrasound dosimetry
-
Lafon C, Zderic V, Noble ML, Yuen JC, Kaczkowski PJ, Sapozhnikov OA, Chavrier F, Crum LA, Vaezy S: Gel phantom for use in high-intensity focused ultrasound dosimetry. Ultrasound Med Biol. 2005, 31: 1383-9. 10.1016/j.ultrasmedbio.2005.06.004.
-
(2005)
Ultrasound Med Biol
, vol.31
, pp. 1383-1389
-
-
Lafon, C.1
Zderic, V.2
Noble, M.L.3
Yuen, J.C.4
Kaczkowski, P.J.5
Sapozhnikov, O.A.6
Chavrier, F.7
Crum, L.A.8
Vaezy, S.9
-
40
-
-
34147182208
-
Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique
-
Maruvada S, Harris GR, Herman BA, King RL: Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique. J Acoust Soc Am. 2007, 121: 1434-9. 10.1121/1.2431332.
-
(2007)
J Acoust Soc Am
, vol.121
, pp. 1434-1439
-
-
Maruvada, S.1
Harris, G.R.2
Herman, B.A.3
King, R.L.4
-
41
-
-
34250343029
-
Acoustic droplet vaporization threshold: effects of pulse duration and contrast agent
-
Lo AH, Kripfgans OD, Carson PL, Rothman ED, Fowlkes JB: Acoustic droplet vaporization threshold: effects of pulse duration and contrast agent. IEEE Trans Ultrason Ferroelectr Freq Control. 2007, 54: 933-46.
-
(2007)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.54
, pp. 933-946
-
-
Lo, A.H.1
Kripfgans, O.D.2
Carson, P.L.3
Rothman, E.D.4
Fowlkes, J.B.5
-
42
-
-
51849129996
-
Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field
-
Morris H, Rivens I, Shaw A, Haar GT: Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field. Phys Med Biol. 2008, 53: 4759-76. 10.1088/0031-9155/53/17/020.
-
(2008)
Phys Med Biol
, vol.53
, pp. 4759-4776
-
-
Morris, H.1
Rivens, I.2
Shaw, A.3
Haar, G.T.4
-
43
-
-
78751617768
-
Real-time monitoring of high-intensity focused ultrasound lesion formation using acousto-optic sensing
-
Lai P, McLaughlan JR, Draudt AB, Murray TW, Cleveland RO, Roy RA: Real-time monitoring of high-intensity focused ultrasound lesion formation using acousto-optic sensing. Ultrasound Med Biol. 2011, 37: 239-52. 10.1016/j.ultrasmedbio.2010.11.004.
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 239-252
-
-
Lai, P.1
McLaughlan, J.R.2
Draudt, A.B.3
Murray, T.W.4
Cleveland, R.O.5
Roy, R.A.6
-
44
-
-
79960952556
-
Decafluorobutane as a phase-change contrast agent for low-energy extravascular ultrasonic imaging
-
Sheeran PS, Wong VP, Luois S, McFarland RJ, Ross WD, Feingold S, Matsunaga TO, Dayton PA: Decafluorobutane as a phase-change contrast agent for low-energy extravascular ultrasonic imaging. Ultrasound Med Biol. 2011, 37: 1518-30. 10.1016/j.ultrasmedbio.2011.05.021.
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 1518-1530
-
-
Sheeran, P.S.1
Wong, V.P.2
Luois, S.3
McFarland, R.J.4
Ross, W.D.5
Feingold, S.6
Matsunaga, T.O.7
Dayton, P.A.8
-
45
-
-
79952737205
-
HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat
-
Kyriakou Z, Corral-Baques MI, Amat A, Coussios CC: HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat. Ultrasound Med Biol. 2011, 37: 568-79. 10.1016/j.ultrasmedbio.2011.01.001.
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 568-579
-
-
Kyriakou, Z.1
Corral-Baques, M.I.2
Amat, A.3
Coussios, C.C.4
-
46
-
-
0025953643
-
Surface modification of haemoglobin-containing liposomes with polyethylene glycol prevents liposome aggregation in blood plasma
-
Yoshioka H: Surface modification of haemoglobin-containing liposomes with polyethylene glycol prevents liposome aggregation in blood plasma. Biomaterials. 1991, 12: 861-4. 10.1016/0142-9612(91)90075-L.
-
(1991)
Biomaterials
, vol.12
, pp. 861-864
-
-
Yoshioka, H.1
-
47
-
-
0035137152
-
Phase behavior and aggregate structure in mixtures of dioleoylphosphatidylethanolamine and poly(ethylene glycol)-lipids
-
Johnsson M, Edwards K: Phase behavior and aggregate structure in mixtures of dioleoylphosphatidylethanolamine and poly(ethylene glycol)-lipids. Biophys J. 2001, 80: 313-23. 10.1016/S0006-3495(01)76016-X.
-
(2001)
Biophys J
, vol.80
, pp. 313-323
-
-
Johnsson, M.1
Edwards, K.2
-
48
-
-
0025341615
-
Amphipathic polyethyleneglycols effectively prolong the circulation time of liposomes
-
Klibanov AL, Maruyama K, Torchilin VP, Huang L: Amphipathic polyethyleneglycols effectively prolong the circulation time of liposomes. FEBS Lett. 1990, 268: 235-7. 10.1016/0014-5793(90)81016-H.
-
(1990)
FEBS Lett
, vol.268
, pp. 235-237
-
-
Klibanov, A.L.1
Maruyama, K.2
Torchilin, V.P.3
Huang, L.4
-
49
-
-
0028055226
-
Effect of liposome size on the circulation time and intraorgan distribution of amphipathic poly(ethylene glycol)-containing liposomes
-
Litzinger DC, Buiting AM, van Rooijen N, Huang L: Effect of liposome size on the circulation time and intraorgan distribution of amphipathic poly(ethylene glycol)-containing liposomes. Biochim Biophys Acta. 1994, 1190: 99-107. 10.1016/0005-2736(94)90038-8.
-
(1994)
Biochim Biophys Acta
, vol.1190
, pp. 99-107
-
-
Litzinger, D.C.1
Buiting, A.M.2
van Rooijen, N.3
Huang, L.4
-
50
-
-
0025731906
-
Liposomes containing synthetic lipid derivatives of poly(ethylene glycol) show prolonged circulation half-lives in vivo
-
Allen TM, Hansen C, Martin F, Redemann C, Yau-Young A: Liposomes containing synthetic lipid derivatives of poly(ethylene glycol) show prolonged circulation half-lives in vivo. Biochim Biophys Acta. 1991, 1066: 29-36. 10.1016/0005-2736(91)90246-5.
-
(1991)
Biochim Biophys Acta
, vol.1066
, pp. 29-36
-
-
Allen, T.M.1
Hansen, C.2
Martin, F.3
Redemann, C.4
Yau-Young, A.5
-
51
-
-
0037681850
-
Pharmacokinetics of pegylated liposomal Doxorubicin: review of animal and human studies
-
Gabizon A, Shmeeda H, Barenholz Y: Pharmacokinetics of pegylated liposomal Doxorubicin: review of animal and human studies. Clin Pharmacokinet. 2003, 42: 419-36. 10.2165/00003088-200342050-00002.
-
(2003)
Clin Pharmacokinet
, vol.42
, pp. 419-436
-
-
Gabizon, A.1
Shmeeda, H.2
Barenholz, Y.3
-
52
-
-
56949085275
-
Feasibility of using ultrasound contrast agents to increase the size of thermal lesions induced by non-focused transducers: in vitro demonstration in tissue mimicking phantom
-
Lafon C, Murillo-Rincon A, Goldenstedt C, Chapelon JY, Mithieux F, Owen NR, Cathignol D: Feasibility of using ultrasound contrast agents to increase the size of thermal lesions induced by non-focused transducers: in vitro demonstration in tissue mimicking phantom. Ultrasonics. 2009, 49: 172-8. 10.1016/j.ultras.2008.07.013.
-
(2009)
Ultrasonics
, vol.49
, pp. 172-178
-
-
Lafon, C.1
Murillo-Rincon, A.2
Goldenstedt, C.3
Chapelon, J.Y.4
Mithieux, F.5
Owen, N.R.6
Cathignol, D.7
-
53
-
-
67650999516
-
Ablation of high-intensity focused ultrasound assisted with SonoVue on Rabbit VX2 liver tumors: sequential findings with histopathology, immunohistochemistry, and enzyme histochemistry
-
Luo W, Zhou X, Yu M, He G, Zheng X, Li Q, Liu Q, Han Z, Zhang J, Qian Y: Ablation of high-intensity focused ultrasound assisted with SonoVue on Rabbit VX2 liver tumors: sequential findings with histopathology, immunohistochemistry, and enzyme histochemistry. Ann Surg Oncol. 2009, 16: 2359-68. 10.1245/s10434-009-0419-3.
-
(2009)
Ann Surg Oncol
, vol.16
, pp. 2359-2368
-
-
Luo, W.1
Zhou, X.2
Yu, M.3
He, G.4
Zheng, X.5
Li, Q.6
Liu, Q.7
Han, Z.8
Zhang, J.9
Qian, Y.10
-
54
-
-
22144456765
-
Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue
-
Kaneko Y, Maruyama T, Takegami K, Watanabe T, Mitsui H, Hanajiri K, Nagawa H, Matsumoto Y: Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue. Eur Radiol. 2005, 15: 1415-20. 10.1007/s00330-005-2663-7.
-
(2005)
Eur Radiol
, vol.15
, pp. 1415-1420
-
-
Kaneko, Y.1
Maruyama, T.2
Takegami, K.3
Watanabe, T.4
Mitsui, H.5
Hanajiri, K.6
Nagawa, H.7
Matsumoto, Y.8
-
55
-
-
0035001175
-
Use of overpressure to assess the role of bubbles in focused ultrasound lesion shape in vitro
-
Bailey MR, Couret LN, Sapozhnikov OA, Khokhlova VA, ter Haar G, Vaezy S, Shi X, Martin R, Crum LA: Use of overpressure to assess the role of bubbles in focused ultrasound lesion shape in vitro. Ultrasound Med Biol. 2001, 27: 695-708. 10.1016/S0301-5629(01)00342-8.
-
(2001)
Ultrasound Med Biol
, vol.27
, pp. 695-708
-
-
Bailey, M.R.1
Couret, L.N.2
Sapozhnikov, O.A.3
Khokhlova, V.A.4
ter Haar, G.5
Vaezy, S.6
Shi, X.7
Martin, R.8
Crum, L.A.9
-
56
-
-
77955345890
-
A study of bubble activity generated in ex vivo tissue by high intensity focused ultrasound
-
McLaughlan J, Rivens I, Leighton T, Ter Haar G: A study of bubble activity generated in ex vivo tissue by high intensity focused ultrasound. Ultrasound Med Biol. 2010, 36: 1327-44. 10.1016/j.ultrasmedbio.2010.05.011.
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 1327-1344
-
-
McLaughlan, J.1
Rivens, I.2
Leighton, T.3
Ter Haar, G.4
-
57
-
-
0034037755
-
The intensity dependence of lesion position shift during focused ultrasound surgery
-
Meaney PM, Cahill MD, ter Haar GR: The intensity dependence of lesion position shift during focused ultrasound surgery. Ultrasound Med Biol. 2000, 26: 441-50. 10.1016/S0301-5629(99)00161-1.
-
(2000)
Ultrasound Med Biol
, vol.26
, pp. 441-450
-
-
Meaney, P.M.1
Cahill, M.D.2
ter Haar, G.R.3
|