메뉴 건너뛰기




Volumn 63, Issue 1, 2017, Pages 394-402

Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I

(23)  Neumann, Johannes Tobias a,b   Sörensen, Nils Arne a   Ojeda, Francisco a   Schwemer, Tjark a   Lehmacher, Jonas a   Gönner, Saskia a   Jarsetz, Nikolas a   Keller, Till c   Schaefer, Sarina a,b   Renné, Thomas d,e   Landmesser, Ulf f   Clemmensen, Peter a,g   Makarova, Nataliya a,b   Schnabel, Renate B a,b   Zeller, Tanja a,b   Karakas, Mahir a,b   Pickering, John W h   Than, Martin h   Parsonage, William i   Greenslade, Jaimi i   more..


Author keywords

[No Author keywords available]

Indexed keywords

C REACTIVE PROTEIN; TROPONIN I; BIOLOGICAL MARKER;

EID: 85008472877     PISSN: 00099147     EISSN: 15308561     Source Type: Journal    
DOI: 10.1373/clinchem.2016.262659     Document Type: Article
Times cited : (57)

References (19)
  • 1
    • 69349100568 scopus 로고    scopus 로고
    • Sensitive troponin I assay in early diagnosis of acute myocardial infarction
    • Keller T, Zeller T, Peetz D, Tzikas S, Roth A, Czyz E, et al. Sensitive troponin I assay in early diagnosis of acute myocardial infarction. N Engl J Med 2009;361:868-77.
    • (2009) N Engl J Med , vol.361 , pp. 868-877
    • Keller, T.1    Zeller, T.2    Peetz, D.3    Tzikas, S.4    Roth, A.5    Czyz, E.6
  • 2
    • 84555195443 scopus 로고    scopus 로고
    • Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction
    • Keller T, Zeller T, Ojeda F, Tzikas S, Lillpopp L, Sinning C, et al. Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. JAMA 2011;306:2684-93.
    • (2011) JAMA , vol.306 , pp. 2684-2693
    • Keller, T.1    Zeller, T.2    Ojeda, F.3    Tzikas, S.4    Lillpopp, L.5    Sinning, C.6
  • 3
    • 84971619896 scopus 로고    scopus 로고
    • 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting Without Persistent ST-Segment Elevation of The European Society of Cardiology (ESC)
    • Roffi M, Patrono C, Collet JP, Mueller C, Valgimigli M, Andreotti F, et al. 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting Without Persistent ST-Segment Elevation Of The European Society Of Cardiology (ESC). Eur Heart J 2016;37:267-315.
    • (2016) Eur Heart J , vol.37 , pp. 267-315
    • Roffi, M.1    Patrono, C.2    Collet, J.P.3    Mueller, C.4    Valgimigli, M.5    Andreotti, F.6
  • 4
    • 85016152439 scopus 로고    scopus 로고
    • Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm
    • Neumann JT, Sorensen NA, Schwemer T, Ojeda F, Bourry R, Sciacca V, et al. Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm. JAMA Cardiol 2016;1:397-404.
    • (2016) JAMA Cardiol , vol.1 , pp. 397-404
    • Neumann, J.T.1    Sorensen, N.A.2    Schwemer, T.3    Ojeda, F.4    Bourry, R.5    Sciacca, V.6
  • 5
    • 84954306118 scopus 로고    scopus 로고
    • Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T
    • e4
    • Mueller C, Giannitsis E, Christ M, Ordonez-Llanos J, de-Filippi C, McCord J, et al. Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T. Ann Emerg Med 2016;68:76-87. e4.
    • (2016) Ann Emerg Med , vol.68 , pp. 76-87
    • Mueller, C.1    Giannitsis, E.2    Christ, M.3    Ordonez-Llanos, J.4    De-Filippi, C.5    McCord, J.6
  • 6
    • 84937812627 scopus 로고    scopus 로고
    • One-hour rule-in and ruleout of acute myocardial infarction using high-sensitivity cardiac troponin I
    • e4
    • Rubini Gimenez M, Twerenbold R, Jaeger C, Schindler C, Puelacher C, Wildi K, et al. One-hour rule-in and ruleout of acute myocardial infarction using high-sensitivity cardiac troponin I. Am J Med 2015;128:861-70. e4.
    • (2015) Am J Med , vol.128 , pp. 861-870
    • Rubini Gimenez, M.1    Twerenbold, R.2    Jaeger, C.3    Schindler, C.4    Puelacher, C.5    Wildi, K.6
  • 7
    • 84964696078 scopus 로고    scopus 로고
    • Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay
    • Reichlin T, Twerenbold R, Wildi K, Gimenez MR, Bergsma N, Haaf P, et al. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. CMAJ 2015;187:E243-52.
    • (2015) CMAJ , vol.187 , pp. E243-E252
    • Reichlin, T.1    Twerenbold, R.2    Wildi, K.3    Gimenez, M.R.4    Bergsma, N.5    Haaf, P.6
  • 8
    • 85008912351 scopus 로고    scopus 로고
    • A 1-h combination algorithm allows fast ruleout and rule-in of major adverse cardiac events
    • Mokhtari A, Borna C, Gilje P, Tydén P, Lindahl B, Nilsson HJ, et al. A 1-h combination algorithm allows fast ruleout and rule-in of major adverse cardiac events. J Am Coll Cardiol 2016;67:1531-40.
    • (2016) J Am Coll Cardiol , vol.67 , pp. 1531-1540
    • Mokhtari, A.1    Borna, C.2    Gilje, P.3    Tydén, P.4    Lindahl, B.5    Nilsson, H.J.6
  • 9
    • 80052974660 scopus 로고    scopus 로고
    • Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay
    • Body R, Carley S, McDowell G, Jaffe AS, France M, Cruickshank K, et al. Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay. J Am Coll Cardiol 2011;58:1332-9.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1332-1339
    • Body, R.1    Carley, S.2    McDowell, G.3    Jaffe, A.S.4    France, M.5    Cruickshank, K.6
  • 10
    • 84886304639 scopus 로고    scopus 로고
    • Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin
    • Rubini Gimenez M, Hoeller R, Reichlin T, Zellweger C, Twerenbold R, Reiter M, et al. Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin. Int J Cardiol 2013;168:3896-901.
    • (2013) Int J Cardiol , vol.168 , pp. 3896-3901
    • Rubini Gimenez, M.1    Hoeller, R.2    Reichlin, T.3    Zellweger, C.4    Twerenbold, R.5    Reiter, M.6
  • 11
    • 84921908439 scopus 로고    scopus 로고
    • Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: Systematic review and metaanalysis
    • Zhelev Z, Hyde C, Youngman E, Rogers M, Fleming S, Slade T, et al. Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and metaanalysis. BMJ 2015;350:h15.
    • (2015) BMJ , vol.350 , pp. h15
    • Zhelev, Z.1    Hyde, C.2    Youngman, E.3    Rogers, M.4    Fleming, S.5    Slade, T.6
  • 12
    • 84902138306 scopus 로고    scopus 로고
    • Undetectable high sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction
    • Bandstein N, Ljung R, Johansson M, Holzmann MJ. Undetectable high sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction. J Am Coll Cardiol 2014;63:2569-78.
    • (2014) J Am Coll Cardiol , vol.63 , pp. 2569-2578
    • Bandstein, N.1    Ljung, R.2    Johansson, M.3    Holzmann, M.J.4
  • 13
    • 84960327828 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: A cohort study
    • Shah AS, Anand A, Sandoval Y, Lee KK, Smith SW, Adamson PD, et al. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet 2015;386:2481-8.
    • (2015) Lancet , vol.386 , pp. 2481-2488
    • Shah, A.S.1    Anand, A.2    Sandoval, Y.3    Lee, K.K.4    Smith, S.W.5    Adamson, P.D.6
  • 15
    • 84893822597 scopus 로고    scopus 로고
    • High population prevalence of cardiac troponin I measured by a high-sensitivity assay and cardiovascular risk estimation: The MORGAM Biomarker Project Scottish Cohort
    • Zeller T, Tunstall-Pedoe H, Saarela O, Ojeda F, Schnabel RB, Tuovinen T, et al. High population prevalence of cardiac troponin I measured by a high-sensitivity assay and cardiovascular risk estimation: the MORGAM Biomarker Project Scottish Cohort. Eur Heart J 2014;35:271-81.
    • (2014) Eur Heart J , vol.35 , pp. 271-281
    • Zeller, T.1    Tunstall-Pedoe, H.2    Saarela, O.3    Ojeda, F.4    Schnabel, R.B.5    Tuovinen, T.6
  • 16
    • 84928011128 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin I in the general population-defining reference populations for the determination of the 99th percentile in the Gutenberg Health Study
    • Zeller T, Ojeda F, Brunner FJ, Peitsmeyer P, Munzel T, Binder H, et al. High-sensitivity cardiac troponin I in the general population-defining reference populations for the determination of the 99th percentile in the Gutenberg Health Study. Clin Chem Lab Med 2015;53:699-706.
    • (2015) Clin Chem Lab Med , vol.53 , pp. 699-706
    • Zeller, T.1    Ojeda, F.2    Brunner, F.J.3    Peitsmeyer, P.4    Munzel, T.5    Binder, H.6
  • 17
    • 84861607690 scopus 로고    scopus 로고
    • 2-hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: The ADAPT Trial
    • Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al. 2-hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT Trial. J Am Coll Cardiol 2012;59:2091-8.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2091-2098
    • Than, M.1    Cullen, L.2    Aldous, S.3    Parsonage, W.A.4    Reid, C.M.5    Greenslade, J.6
  • 18
    • 85008445512 scopus 로고    scopus 로고
    • Evaluation of high-sensitivity cardiac troponin I levels in patients with suspected acute coronary syndrome
    • Carlton E, Greenslade J, Cullen L, Body R, Than M, Pickering JW, et al. Evaluation of high-sensitivity cardiac troponin I levels in patients with suspected acute coronary syndrome. JAMA Cardiol 2016;1:405-12.
    • (2016) JAMA Cardiol , vol.1 , pp. 405-412
    • Carlton, E.1    Greenslade, J.2    Cullen, L.3    Body, R.4    Than, M.5    Pickering, J.W.6
  • 19
    • 2642527078 scopus 로고    scopus 로고
    • A validated prediction model for all forms of acute coronary syndrome: Estimating the risk of 6-month postdischarge death in an international registry
    • Eagle KA, Lim MJ, Dabbous OH, Pieper KS, Goldberg RJ, Van de Werf F, et al. A validated prediction model for all forms of acute coronary syndrome: Estimating the risk of 6-month postdischarge death in an international registry. JAMA 2004;291:2727-33.
    • (2004) JAMA , vol.291 , pp. 2727-2733
    • Eagle, K.A.1    Lim, M.J.2    Dabbous, O.H.3    Pieper, K.S.4    Goldberg, R.J.5    Van De Werf, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.