메뉴 건너뛰기




Volumn 1473, Issue , 2016, Pages 48-55

On the feasibility to conduct gradient liquid chromatography separations in narrow-bore columns at pressures up to 2000 bar

Author keywords

2.1 mm ID; Gradient elution; Narrow bore columns; Preloaded gradient; Ultra high pressure; Viscous heating

Indexed keywords

CAPILLARY FLOW; CHROMATOGRAPHIC ANALYSIS; PUMPS;

EID: 84994631257     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2016.10.008     Document Type: Article
Times cited : (10)

References (38)
  • 1
    • 25944442284 scopus 로고
    • Ultimate limits in high-pressure liquid chromatography
    • [1] Halasz, I., Endele, R., Asshauer, J., Ultimate limits in high-pressure liquid chromatography. J. Chromatogr., 112, 1975, 37.
    • (1975) J. Chromatogr. , vol.112 , pp. 37
    • Halasz, I.1    Endele, R.2    Asshauer, J.3
  • 2
    • 0003017403 scopus 로고
    • Band spreading in liquid chromatography: general plate height equation and a method for the evaluation of the individual plate height contributions
    • [2] Horvath, Cs., Lin, H.-J., Band spreading in liquid chromatography: general plate height equation and a method for the evaluation of the individual plate height contributions. J. Chromatogr., 149, 1978, 43.
    • (1978) J. Chromatogr. , vol.149 , pp. 43
    • Horvath, C.1    Lin, H.-J.2
  • 3
    • 0000297576 scopus 로고
    • Influence of thermal conditions on the efficiency of high-performance liquid chromatographic columns
    • [3] Poppe, H., Kraak, J.C., Huber, J.F.K., Van den Berg, J.H.M., Influence of thermal conditions on the efficiency of high-performance liquid chromatographic columns. Chromatographia, 14, 1981, 515.
    • (1981) Chromatographia , vol.14 , pp. 515
    • Poppe, H.1    Kraak, J.C.2    Huber, J.F.K.3    Van den Berg, J.H.M.4
  • 4
    • 0001609681 scopus 로고
    • Influence of thermal conditions on the efficiency of high-performance liquid chromatographic columns
    • [4] Poppe, H., Kraak, J.C., Influence of thermal conditions on the efficiency of high-performance liquid chromatographic columns. J. Chromatogr., 282, 1983, 399.
    • (1983) J. Chromatogr. , vol.282 , pp. 399
    • Poppe, H.1    Kraak, J.C.2
  • 5
    • 33645975885 scopus 로고    scopus 로고
    • Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm I.D. columns
    • [5] de Villiers, A., Lauer, H., Szucs, R., Goodall, S., Sandra, P., Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm I.D. columns. J. Chromatogr. A, 1113, 2009, 84.
    • (2009) J. Chromatogr. A , vol.1113 , pp. 84
    • de Villiers, A.1    Lauer, H.2    Szucs, R.3    Goodall, S.4    Sandra, P.5
  • 6
    • 23944464010 scopus 로고    scopus 로고
    • Effects of high pressure in liquid chromatography
    • [6] Martin, M., Guiochon, G., Effects of high pressure in liquid chromatography. J. Chromatogr. A, 1090, 2005, 16.
    • (2005) J. Chromatogr. A , vol.1090 , pp. 16
    • Martin, M.1    Guiochon, G.2
  • 7
    • 33749258520 scopus 로고    scopus 로고
    • Effects of the thermal heterogeneity of the column on chromatographic results
    • [7] Gritti, F., Guiochon, G., Effects of the thermal heterogeneity of the column on chromatographic results. J. Chromatogr. A, 1131, 2006, 151.
    • (2006) J. Chromatogr. A , vol.1131 , pp. 151
    • Gritti, F.1    Guiochon, G.2
  • 8
    • 33845411125 scopus 로고    scopus 로고
    • Measurement of the axial and radial temperature profiles of a chromatographic column: influence of thermal insulation on column efficiency
    • [8] Gritti, F., Guiochon, G., Measurement of the axial and radial temperature profiles of a chromatographic column: influence of thermal insulation on column efficiency. J. Chromatogr. A, 1138, 2007, 141.
    • (2007) J. Chromatogr. A , vol.1138 , pp. 141
    • Gritti, F.1    Guiochon, G.2
  • 9
    • 34247271306 scopus 로고    scopus 로고
    • Performance of idealized column structures under high pressure
    • [9] Neue, U.D., Kele, M., Performance of idealized column structures under high pressure. J. Chromatogr. A, 1149, 2007, 236.
    • (2007) J. Chromatogr. A , vol.1149 , pp. 236
    • Neue, U.D.1    Kele, M.2
  • 10
    • 63649105157 scopus 로고    scopus 로고
    • Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 m and 5 m) columns in reversed-phase high-performance liquid chromatography
    • [10] Fallas, M.M., Hadley, M.R., McCalley, D.V., Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 m and 5 m) columns in reversed-phase high-performance liquid chromatography. J. Chromatogr. A, 1216, 2009, 3961.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 3961
    • Fallas, M.M.1    Hadley, M.R.2    McCalley, D.V.3
  • 11
    • 63449127156 scopus 로고    scopus 로고
    • Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 m and 5 m) columns in reversed-phase high-performance liquid chromatography
    • [11] Cabooter, D., Lestremau, F., de Villiers, A., Broeckhoven, K., Lynen, F., Sandra, P., Desmet, G., Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 m and 5 m) columns in reversed-phase high-performance liquid chromatography. J. Chromatogr. A, 1216, 2009, 3895.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 3895
    • Cabooter, D.1    Lestremau, F.2    de Villiers, A.3    Broeckhoven, K.4    Lynen, F.5    Sandra, P.6    Desmet, G.7
  • 12
    • 80053946563 scopus 로고    scopus 로고
    • Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating
    • [12] Novakova, L., Veuthey, J.L., Guillarme, D., Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating. J. Chromatogr. A, 1218, 2011, 7971.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 7971
    • Novakova, L.1    Veuthey, J.L.2    Guillarme, D.3
  • 14
    • 84938743712 scopus 로고    scopus 로고
    • High-speed isocratic and gradient liquid-chromatography separations at 1500 bar
    • [14] De Vos, J., De Pra, M., Desmet, G., Swart, R., Edge, T., Steiner, F., Eeltink, S., High-speed isocratic and gradient liquid-chromatography separations at 1500 bar. J. Chromatogr. A 1409 (2015), 138–145.
    • (2015) J. Chromatogr. A , vol.1409 , pp. 138-145
    • De Vos, J.1    De Pra, M.2    Desmet, G.3    Swart, R.4    Edge, T.5    Steiner, F.6    Eeltink, S.7
  • 15
    • 0031569131 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns
    • [15] MacNair, J.E., Lewis, K.C., Jorgenson, J.W., Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. Anal. Chem., 69, 1997, 983.
    • (1997) Anal. Chem. , vol.69 , pp. 983
    • MacNair, J.E.1    Lewis, K.C.2    Jorgenson, J.W.3
  • 16
    • 0033082675 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0-m particles
    • [16] MacNair, J.E., Patel, K.D., Jorgenson, J.W., Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0-m particles. Anal. Chem., 71, 1999, 700.
    • (1999) Anal. Chem. , vol.71 , pp. 700
    • MacNair, J.E.1    Patel, K.D.2    Jorgenson, J.W.3
  • 17
    • 0035387613 scopus 로고    scopus 로고
    • Very high pressure gradient LC/MS/MS
    • [17] Tolley, L., Jorgenson, J.W., Moseley, A., Very high pressure gradient LC/MS/MS. Anal. Chem., 73, 2001, 2985.
    • (2001) Anal. Chem. , vol.73 , pp. 2985
    • Tolley, L.1    Jorgenson, J.W.2    Moseley, A.3
  • 18
    • 4544276272 scopus 로고    scopus 로고
    • Use of 1.5-m porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography
    • [18] Mellors, J.S., Jorgenson, J.W., Use of 1.5-m porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography. Anal. Chem., 76, 2004, 5441.
    • (2004) Anal. Chem. , vol.76 , pp. 5441
    • Mellors, J.S.1    Jorgenson, J.W.2
  • 20
    • 84901069996 scopus 로고    scopus 로고
    • Extending the limits of operating pressure of narrow-bore column liquid chromatography instrumentation
    • [20] De Pauw, R., Degreef, B., Ritchie, H., Eeltink, S., Desmet, G., Broeckhoven, K., Extending the limits of operating pressure of narrow-bore column liquid chromatography instrumentation. J. Chromatogr. A, 1347, 2014, 56.
    • (2014) J. Chromatogr. A , vol.1347 , pp. 56
    • De Pauw, R.1    Degreef, B.2    Ritchie, H.3    Eeltink, S.4    Desmet, G.5    Broeckhoven, K.6
  • 21
    • 77349092305 scopus 로고    scopus 로고
    • Towards a solution for viscous heating in ultra-high pressure liquid chromatography using intermediate cooling
    • [21] Broeckhoven, K., Billen, J., Verstraeten, M., Choikhet, K., Dittmann, M., Rozing, G., Desmet, G., Towards a solution for viscous heating in ultra-high pressure liquid chromatography using intermediate cooling. J. Chromatogr. A, 1217, 2010, 2022.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 2022
    • Broeckhoven, K.1    Billen, J.2    Verstraeten, M.3    Choikhet, K.4    Dittmann, M.5    Rozing, G.6    Desmet, G.7
  • 22
    • 79251616078 scopus 로고    scopus 로고
    • Kinetic performance limits of constant pressure versus constant flow rate gradient elution separations. Part I: Theory
    • [22] Broeckhoven, K., Verstraeten, M., Choikhet, K., Dittmann, M., Witt, K., Desmet, G., Kinetic performance limits of constant pressure versus constant flow rate gradient elution separations. Part I: Theory. J. Chromatogr. A, 1218, 2011, 1153.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 1153
    • Broeckhoven, K.1    Verstraeten, M.2    Choikhet, K.3    Dittmann, M.4    Witt, K.5    Desmet, G.6
  • 23
    • 79251616078 scopus 로고    scopus 로고
    • Kinetic performance limits of constant pressure versus constant flow rate gradient elution separations. Part I: Theory
    • [23] Verstraeten, M., Broeckhoven, K., Choikhet, K., Dittmann, M., Witt, K., Desmet, G., Kinetic performance limits of constant pressure versus constant flow rate gradient elution separations. Part I: Theory. J. Chromatogr. A, 1218, 2011, 1170.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 1170
    • Verstraeten, M.1    Broeckhoven, K.2    Choikhet, K.3    Dittmann, M.4    Witt, K.5    Desmet, G.6
  • 24
    • 84992393080 scopus 로고    scopus 로고
    • Doctoral dissertation, Development and Application of Gradient Ultrahigh Pressure Liquid Chromatography for Separations of Complex Biological Mixtures
    • The University of North Carolina Chapel Hill
    • [24] Link, J.C., Doctoral dissertation, Development and Application of Gradient Ultrahigh Pressure Liquid Chromatography for Separations of Complex Biological Mixtures. 2004, The University of North Carolina, Chapel Hill.
    • (2004)
    • Link, J.C.1
  • 25
    • 33644755630 scopus 로고    scopus 로고
    • Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures
    • [25] Eschelbach, J.W., Jorgenson, J.W., Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures. Anal. Chem. 78 (2006), 1697–1706.
    • (2006) Anal. Chem. , vol.78 , pp. 1697-1706
    • Eschelbach, J.W.1    Jorgenson, J.W.2
  • 26
    • 78049383226 scopus 로고    scopus 로고
    • Capillary liquid chromatography at ultrahigh pressures
    • [26] Jorgenson, J.W., Capillary liquid chromatography at ultrahigh pressures. Annu. Rev. Anal. Chem. 3 (2010), 129–150.
    • (2010) Annu. Rev. Anal. Chem. , vol.3 , pp. 129-150
    • Jorgenson, J.W.1
  • 27
    • 84867471479 scopus 로고    scopus 로고
    • Potential advantage of constant pressure versus constant flow gradient chromatography for the analysis of small molecules
    • [27] Gritti, F., Stankovich, J.J., Guiochon, G., Potential advantage of constant pressure versus constant flow gradient chromatography for the analysis of small molecules. J. Chromatogr. A, 1263, 2012, 51.
    • (2012) J. Chromatogr. A , vol.1263 , pp. 51
    • Gritti, F.1    Stankovich, J.J.2    Guiochon, G.3
  • 28
    • 53649095170 scopus 로고    scopus 로고
    • Influence of pressure and temperature on the physico-chemical properties of mobile phase mixtures commonly used in high-performance liquid chromatography
    • [28] Billen, J., Broeckhoven, K., Liekens, A., Choikhet, K., Rozing, G., Desmet, G., Influence of pressure and temperature on the physico-chemical properties of mobile phase mixtures commonly used in high-performance liquid chromatography. J. Chromatogr. A, 1210, 2008, 30.
    • (2008) J. Chromatogr. A , vol.1210 , pp. 30
    • Billen, J.1    Broeckhoven, K.2    Liekens, A.3    Choikhet, K.4    Rozing, G.5    Desmet, G.6
  • 29
    • 77953716491 scopus 로고    scopus 로고
    • The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation
    • [29] Broeckhoven, K., Cabooter, D., Lynen, F., Sandra, P., Desmet, G., The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation. J. Chromatogr., 1217, 2010, 2787.
    • (2010) J. Chromatogr. , vol.1217 , pp. 2787
    • Broeckhoven, K.1    Cabooter, D.2    Lynen, F.3    Sandra, P.4    Desmet, G.5
  • 30
    • 53749097442 scopus 로고    scopus 로고
    • Investigation of the effect of pressure on retention of small molecules using reversed-phase ultra-high-pressure liquid chromatography
    • [30] Fallas, M.M., Neue, U.D., Hadley, M.R., McCalley, D.V., Investigation of the effect of pressure on retention of small molecules using reversed-phase ultra-high-pressure liquid chromatography. J. Chromatogr. A, 1209, 2008, 195.
    • (2008) J. Chromatogr. A , vol.1209 , pp. 195
    • Fallas, M.M.1    Neue, U.D.2    Hadley, M.R.3    McCalley, D.V.4
  • 31
    • 84922065619 scopus 로고    scopus 로고
    • Comparison and optimization of different peak integration methods to determine the variance of unretained and extra-column peaks
    • [31] Vanderheyden, Y., Broeckhoven, K., Desmet, G., Comparison and optimization of different peak integration methods to determine the variance of unretained and extra-column peaks. J. Chromatogr. A, 1364, 2014, 140.
    • (2014) J. Chromatogr. A , vol.1364 , pp. 140
    • Vanderheyden, Y.1    Broeckhoven, K.2    Desmet, G.3
  • 32
    • 58149110780 scopus 로고    scopus 로고
    • Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequence in two-dimensional high-performance liquid chromatography
    • [32] Shalliker, R.A., Guiochon, G., Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequence in two-dimensional high-performance liquid chromatography. J. Chromatogr. A, 1216, 2009, 787.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 787
    • Shalliker, R.A.1    Guiochon, G.2
  • 33
    • 84994671201 scopus 로고    scopus 로고
    • [33] http://www.bronkhorst.com/files/coriolis/downloads/brochures-en/mini_coriflow.pdf.
  • 34
    • 33847321521 scopus 로고    scopus 로고
    • The bandwidth in gradient elution chromatography with a retained organic modifier
    • [34] Gritti, F., Guiochon, G., The bandwidth in gradient elution chromatography with a retained organic modifier. J. Chromatogr. A 1145 (2007), 67–82.
    • (2007) J. Chromatogr. A , vol.1145 , pp. 67-82
    • Gritti, F.1    Guiochon, G.2
  • 35
    • 56949100347 scopus 로고    scopus 로고
    • Experimental band compression factor of a neutral compound under high pressure gradient elution
    • [35] Gritti, F., Guiochon, G., Experimental band compression factor of a neutral compound under high pressure gradient elution. J. Chromatogr. A 1215 (2008), 64–73.
    • (2008) J. Chromatogr. A , vol.1215 , pp. 64-73
    • Gritti, F.1    Guiochon, G.2
  • 36
    • 59049099547 scopus 로고    scopus 로고
    • Numerical and analytical solutions for the column length-dependent band broadening originating from axisymmetrical trans-column velocity gradients
    • [36] Broeckhoven, K., Desmet, G., Numerical and analytical solutions for the column length-dependent band broadening originating from axisymmetrical trans-column velocity gradients. J. Chromatogr. A, 1216, 2009, 1325.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 1325
    • Broeckhoven, K.1    Desmet, G.2
  • 37
    • 20444445469 scopus 로고    scopus 로고
    • Theory of peak capacity in gradient elution
    • [37] Neue, U., Theory of peak capacity in gradient elution. J. Chromatogr. A, 1079, 2005, 153.
    • (2005) J. Chromatogr. A , vol.1079 , pp. 153
    • Neue, U.1
  • 38
    • 39749086470 scopus 로고    scopus 로고
    • Peak capacity in unidimensional chromatography
    • [38] Neue, U., Peak capacity in unidimensional chromatography. J. Chromatogr. A, 1184, 2008, 170.
    • (2008) J. Chromatogr. A , vol.1184 , pp. 170
    • Neue, U.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.