메뉴 건너뛰기




Volumn 5, Issue September, 2016, Pages

A novel optical microscope for imaging large embryos and tissue volumes with sub-cellular resolution throughout

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; CELL VOLUME; CONFOCAL MICROSCOPY; EMBRYO; FLUORESCENCE; FLUORESCENCE MICROSCOPY; IMAGING; MICROSCOPY; MITOSIS INDEX; MOUSE; NONHUMAN; OPTICAL RESOLUTION; ORGANOGENESIS; PHOTOLITHOTROPH; RAT; REFRACTION INDEX;

EID: 84988592796     PISSN: None     EISSN: 2050084X     Source Type: Journal    
DOI: 10.7554/eLife.18659     Document Type: Article
Times cited : (120)

References (16)
  • 2
    • 0027488041 scopus 로고
    • A light-emitting diode light standard for photo-and videomicroscopy
    • Beach JM, Duling BR. 1993. A light-emitting diode light standard for photo-and videomicroscopy. Journal of Microscopy 172:41-48. doi: 10.1111/j.1365-2818.1993.tb03391.x
    • (1993) Journal of Microscopy , vol.172 , pp. 41-48
    • Beach, J.M.1    Duling, B.R.2
  • 3
    • 84921845941 scopus 로고    scopus 로고
    • Expansion microscopy
    • Chen F, Tillberg PW, Boyden ES. 2015. Expansion microscopy. Science 347:543-548. doi: 10.1126/science.1260088
    • (2015) Science , vol.347 , pp. 543-548
    • Chen, F.1    Tillberg, P.W.2    Boyden, E.S.3
  • 6
    • 33745799031 scopus 로고    scopus 로고
    • The lithographic lens: Its history and evolution
    • Flagello DG (Ed), 6154 SPIE
    • Matsuyama T, Ohmura Y, Williamson DM. 2006. The lithographic lens: its history and evolution. In: Flagello DG (Ed). Optical Microlithography XIX. 6154 SPIE. doi: 10.1117/12.656163
    • (2006) Optical Microlithography XIX
    • Matsuyama, T.1    Ohmura, Y.2    Williamson, D.M.3
  • 8
    • 0027488040 scopus 로고
    • Image sharpness and contrast transfer in coherent confocal microscopy
    • Oldenbourg R, Terada H, Tiberio R, Inoue´ S. 1993. Image sharpness and contrast transfer in coherent confocal microscopy. Journal of Microscopy 172:31-39. doi: 10.1111/j.1365-2818.1993.tb03390.x
    • (1993) Journal of Microscopy , vol.172 , pp. 31-39
    • Oldenbourg, R.1    Terada, H.2    Tiberio, R.3    Inoue´, S.4
  • 9
    • 84961615113 scopus 로고    scopus 로고
    • Erratum: 0.5 gigapixel microscopy using a flatbed scanner: Erratum
    • Ou X, Zheng G, Yang C. 2016. Erratum: 0.5 gigapixel microscopy using a flatbed scanner: erratum. Biomedical Optics Express 7:646-647. doi: 10.1364/BOE.7.000646
    • (2016) Biomedical Optics Express , vol.7 , pp. 646-647
    • Ou, X.1    Zheng, G.2    Yang, C.3
  • 10
    • 84879384473 scopus 로고    scopus 로고
    • Wide field-of-view Talbot grid-based microscopy for multicolor fluorescence imaging
    • Pang S, Han C, Erath J, Rodriguez A, Yang C. 2013. Wide field-of-view Talbot grid-based microscopy for multicolor fluorescence imaging. Optics Express 21:14555-14565. doi: 10.1364/OE.21.014555
    • (2013) Optics Express , vol.21 , pp. 14555-14565
    • Pang, S.1    Han, C.2    Erath, J.3    Rodriguez, A.4    Yang, C.5
  • 12
    • 84979655975 scopus 로고    scopus 로고
    • A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging
    • Sofroniew NJ, Flickinger D, King J, Svoboda K. 2016. A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging. eLife 5:e14472. doi: 10.7554/eLife.14472
    • (2016) Elife , vol.5
    • Sofroniew, N.J.1    Flickinger, D.2    King, J.3    Svoboda, K.4
  • 14
    • 0023369196 scopus 로고
    • An evaluation of confocal versus conventional imaging of biological structures by fluorescence light microscopy
    • White JG, Amos WB, Fordham M. 1987. An evaluation of confocal versus conventional imaging of biological structures by fluorescence light microscopy. The Journal of Cell Biology 105:41-48. doi: 10.1083/jcb.105.1.41
    • (1987) The Journal of Cell Biology , vol.105 , pp. 41-48
    • White, J.G.1    Amos, W.B.2    Fordham, M.3
  • 15
    • 84883457396 scopus 로고    scopus 로고
    • Wide-field, high-resolution Fourier ptychographic microscopy
    • Zheng G, Horstmeyer R, Yang C. 2013b. Wide-field, high-resolution Fourier ptychographic microscopy. Nature Photonics 7:739-745. doi: 10.1038/nphoton.2013.187
    • (2013) Nature Photonics , vol.7 , pp. 739-745
    • Zheng, G.1    Horstmeyer, R.2    Yang, C.3
  • 16
    • 84889020932 scopus 로고    scopus 로고
    • 0.5 gigapixel microscopy using a flatbed scanner
    • Zheng G, Ou X, Yang C. 2013a. 0.5 gigapixel microscopy using a flatbed scanner. Biomedical Optics Express 5: 1-8. doi: 10.1364/BOE.5.000001
    • (2013) Biomedical Optics Express , vol.5 , pp. 1-8
    • Zheng, G.1    Ou, X.2    Yang, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.