메뉴 건너뛰기




Volumn 54, Issue 10, 2016, Pages e281-e283

Optimal collection tubes for plasma glucose determination: Confusion reigns supreme

Author keywords

Citrate; Glycolysis; Plasma glucose

Indexed keywords

GLUCOSE; GLUCOSE BLOOD LEVEL;

EID: 84987719147     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2016-0137     Document Type: Letter
Times cited : (7)

References (10)
  • 1
    • 84962420556 scopus 로고    scopus 로고
    • Classification and diagnosis of diabetes
    • American Diabetes Association. Standards of medical care in diabetes 2016. Classification and Diagnosis of Diabetes. Diabetes Care 2016;39(Suppl 1):S13-22.
    • (2016) Diabetes Care , vol.39 , pp. S13-S22
  • 2
    • 80051988751 scopus 로고    scopus 로고
    • Position statement executive summary: Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, et al. National Academy of Clinical Biochemistry. Position statement executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 2011;34:1419-23.
    • (2011) Diabetes Care , vol.34 , pp. 1419-1423
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3    Bruns, D.E.4    Horvath, A.R.5    Kirkman, M.S.6
  • 3
    • 43449138195 scopus 로고    scopus 로고
    • Stabilization of glucose in blood specimens: Mechanism of delay in fluoride inhibition of glycolysis
    • Mikesh LM, Bruns DE. Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis. Clin Chem 2008;54:930-2.
    • (2008) Clin Chem , vol.54 , pp. 930-932
    • Mikesh, L.M.1    Bruns, D.E.2
  • 6
    • 84898967908 scopus 로고    scopus 로고
    • Better blood collection tubes for plasma glucose: Ready for prime time?
    • Szöke D, Valente C, Panteghini M. Better blood collection tubes for plasma glucose: ready for prime time? Clin Chem Lab Med 2014;52:e87-9.
    • (2014) Clin Chem Lab Med , vol.52 , pp. e87-e89
    • Szöke, D.1    Valente, C.2    Panteghini, M.3
  • 7
    • 84900310157 scopus 로고    scopus 로고
    • The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing - The impact upon patient results
    • Norman M, Jones I. The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing - The impact upon patient results. Clin Biochem 2014;47:683-5.
    • (2014) Clin Biochem , vol.47 , pp. 683-685
    • Norman, M.1    Jones, I.2
  • 8
    • 84987733720 scopus 로고    scopus 로고
    • Glycolysis inhibition and reliable plasma glucose results: Is the clinical impact carefully considered?
    • Pasqualetti S, Szöke D, Valente C, Panteghini M. Glycolysis inhibition and reliable plasma glucose results: is the clinical impact carefully considered? Clin Chem Lab Med 2015;53:S104.
    • (2015) Clin Chem Lab Med , vol.53 , pp. S104
    • Pasqualetti, S.1    Szöke, D.2    Valente, C.3    Panteghini, M.4
  • 9
    • 84924755738 scopus 로고    scopus 로고
    • What is the most suitable blood collection tube for glucose estimation?
    • Dimeski G, Yow KS, Brown NN. What is the most suitable blood collection tube for glucose estimation? Ann Clin Biochem 2014;52:270-5.
    • (2014) Ann Clin Biochem , vol.52 , pp. 270-275
    • Dimeski, G.1    Yow, K.S.2    Brown, N.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.