-
1
-
-
65949125091
-
Stabilization of glucose in blood samples: Why it matters [editorial]
-
Bruns DE, Knowler WC. Stabilization of glucose in blood samples: why it matters [editorial]. Clin Chem 2009;55: 850-2.
-
(2009)
Clin Chem
, vol.55
, pp. 850-852
-
-
Bruns, D.E.1
Knowler, W.C.2
-
2
-
-
17744400689
-
Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus
-
Stahl M, Jørgensen LG, Hyltoft Petersen P, Brandslund I, De Fine Olivarius N, Borch-Johnsen K. Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus. Scand J Clin Lab Invest 2001;61: 169-80.
-
(2001)
Scand J Clin Lab Invest
, vol.61
, pp. 169-180
-
-
Stahl, M.1
Jørgensen, L.G.2
Hyltoft Petersen, P.3
Brandslund, I.4
De Fine Olivarius, N.5
Borch-Johnsen, K.6
-
3
-
-
43449138195
-
Stabilization of glucose in blood specimens: Mechanism of delay in fluoride inhibition of glycolysis [Letter]
-
Mikesh L, Bruns DE. Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis [Letter]. Clin Chem 2008;54: 930-1.
-
(2008)
Clin Chem
, vol.54
, pp. 930-931
-
-
Mikesh, L.1
Bruns, D.E.2
-
4
-
-
0016661815
-
Sodium iodoacetate as an antiglycolytic agent in blood samples
-
Marbach EP, McLean M, Scharn M, Jones T. Sodium iodoacetate as an antiglycolytic agent in blood samples. Clin Chem 1975;21: 1810-2.
-
(1975)
Clin Chem
, vol.21
, pp. 1810-1812
-
-
Marbach, E.P.1
McLean, M.2
Scharn, M.3
Jones, T.4
-
5
-
-
0034051043
-
The preanalytic phase: An important component of laboratory medicine
-
Narayanan S. The pre-analytic phase: an important component of laboratory medicine. Am J Clin Pathol 2000;113: 429-52. (Pubitemid 30217392)
-
(2000)
American Journal of Clinical Pathology
, vol.113
, Issue.3
, pp. 429-452
-
-
Narayanan, S.1
-
6
-
-
34447319106
-
Glycolysis inhibitors negatively bias blood glucose measurements: Potential impact on the reported prevalence of diabetes mellitus
-
DOI 10.1136/jcp.2006.039925
-
Waring WS, Evans LE, Kirkpatrick CT. Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus. J Clin Pathol 2007;60: 820-3. (Pubitemid 47056914)
-
(2007)
Journal of Clinical Pathology
, vol.60
, Issue.7
, pp. 820-823
-
-
Waring, W.S.1
Evans, L.E.2
Kirkpatrick, C.T.3
-
7
-
-
84888109473
-
-
4th ed. Weinheim: Wiley-VCH Verlag GmbH&Co
-
Guder WG, Narayanan S, Wisser H, Zawta B. editors, Take a lavender tube! In: Diagnostic samples: from the patient to the laboratory, 4th ed. Weinheim: Wiley-VCH Verlag GmbH&Co, 2009: 36-7.
-
(2009)
Take A Lavender Tube! In: Diagnostic Samples: From the Patient to the Laboratory
, pp. 36-37
-
-
Guder, W.G.1
Narayanan, S.2
Wisser, H.3
Zawta, B.4
-
8
-
-
0023270239
-
D-Mannose as a preservative of glucose in blood samples
-
Nakashima K, Takei H, Nasu Y, Andoh Y. D-Mannose as a preservative of glucose in blood samples. Clin Chem 1987;33: 708-10. (Pubitemid 17155703)
-
(1987)
Clinical Chemistry
, vol.33
, Issue.5
, pp. 708-710
-
-
Nakashima, K.1
Takei, H.2
Nasu, Y.3
Andoh, Y.4
-
9
-
-
0026576971
-
D-Mannose as a preservative of glucose in blood samples
-
Chan AY, Ho CS, Chan TY, Swaminathan R. D-Mannose as a preservative of glucose in blood samples. Clin Chem 1992;38: 411-3.
-
(1992)
Clin Chem
, vol.38
, pp. 411-413
-
-
Chan, A.Y.1
Ho, C.S.2
Chan, T.Y.3
Swaminathan, R.4
-
10
-
-
0023819702
-
A new methjod of inhibiting glycolysis in blood samples
-
DOI 10.1016/0009-8981(88)90125-8
-
Uchida K, Matuse R, Toyoda E, Okuda S, Tomita S. A new method of inhibiting glycolysis in blood samples. Clin Chim Acta 1988;172: 101-8. (Pubitemid 18051970)
-
(1988)
Clinica Chimica Acta
, vol.172
, Issue.1
, pp. 101-108
-
-
Uchida, K.1
Matuse, R.2
Toyoda, E.3
Okuda, S.4
Tomita, S.5
-
11
-
-
65949094591
-
Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
-
Gambino R, Piscitelli J, Ackattupathil TA, Theriault JL, Andrin RD, Sanfilippo ML, et al. Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis. Clin Chem 2009;55: 1019-21.
-
(2009)
Clin Chem
, vol.55
, pp. 1019-1021
-
-
Gambino, R.1
Piscitelli, J.2
Ackattupathil, T.A.3
Theriault, J.L.4
Andrin, R.D.5
Sanfilippo, M.L.6
-
12
-
-
84888087568
-
What diagnostic tests should be used to define glycaemic status
-
World Health Organization. Geneva: WHO
-
World Health Organization. What diagnostic tests should be used to define glycaemic status. In: Definition and diagnosis of diabetes mellitus and intermediate hyperglycemia. Geneva: WHO, 2006: 29-30.
-
(2006)
Definition and Diagnosis of Diabetes Mellitus and Intermediate Hyperglycemia
, pp. 29-30
-
-
-
14
-
-
34249800348
-
Diabetes y embarazo. Guía asistencial 2006
-
Bartha JL, Cerqueira MJ, González-González NL, Jáñez M, Mozas J, Ramírez O, et al. Diabetes y embarazo. Guía asistencial 2006 (Diabetes and pregnancy. Clinical guidelines 2006). Prog Obstet Ginecol 2007;50: 249-64.
-
(2007)
Prog Obstet Ginecol
, vol.50
, pp. 249-264
-
-
Bartha, J.L.1
Cerqueira, M.J.2
González-González, N.L.3
Jáñez, M.4
Mozas, J.5
Ramírez, O.6
-
15
-
-
75149180515
-
Standards of medical care in diabetes - 2010
-
SUPPL. 1
-
Standards of medical care in diabetes - 2010. Diabetes Care 2010;33(Suppl 1):S11-61.
-
(2010)
Diabetes Care
, vol.33
-
-
-
16
-
-
48649089665
-
-
Analytical Quality Committee, Spanish Society of Clinical Chemistry and Molecular Pathology (SEQC), Accessed on April 2011
-
Minchinela J, Ricós C, Perich C, Fernández-Calle P, Álvarez V, Domenech M, et al. Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum). The 2012 update. Analytical Quality Committee, Spanish Society of Clinical Chemistry and Molecular Pathology (SEQC). Available from: http://www.westgard. com/biodatabase1.htm. Accessed on April 2011.
-
Biological Variation Database, and Quality Specifications for Imprecision, Bias and Total Error (Desirable and Minimum). The 2012 Update
-
-
Minchinela, J.1
Ricós, C.2
Perich, C.3
Fernández-Calle, P.4
Álvarez, V.5
Domenech, M.6
-
17
-
-
79957715132
-
Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. [Special Report]
-
Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. [Special Report].Clin Chem 2011;57:e1-47.
-
(2011)
Clin Chem
, vol.57
-
-
Sacks, D.B.1
Arnold, M.2
Bakris, G.L.3
Bruns, D.E.4
Horvath, A.R.5
Kirkman, M.S.6
-
18
-
-
84888081665
-
Kokemuksia uudesta glykolyysin estäjästä veren/plasman glukoosimäärityksessä
-
Mäkinen K. Kokemuksia uudesta glykolyysin estäjästä veren/plasman glukoosimäärityksessä (Experiences of new glicólisis inhibitors in blood plasma determination). Kliin Lab 1992;4: 85-8.
-
(1992)
Kliin Lab
, vol.4
, pp. 85-88
-
-
Mäkinen, K.1
-
19
-
-
0018602014
-
Classification and diagnosis of diabetes mellitus and other categories of glucose intolerance
-
National Diabetes Data Group
-
National Diabetes Data Group. Classification and diagnosis of diabetes mellitus and other categories of glucose intolerance. Diabetes 1979;28: 1039-57.
-
(1979)
Diabetes
, vol.28
, pp. 1039-1057
-
-
-
21
-
-
77649254579
-
International Association of Diabetes and Pregnancy Study Groups recommendations on the diagnosis and classification of hyperglycemia in pregnancy
-
International Association of Diabetes and Pregnancy Study Groups Consensus Panel
-
International Association of Diabetes and Pregnancy Study Groups Consensus Panel, Metzger BE, Gabbe SG, Persson B, Buchanan TA, Catalano PA, et al. International Association of Diabetes and Pregnancy Study Groups recommendations on the diagnosis and classification of hyperglycemia in pregnancy. Diabetes Care 2010;33:676-82.
-
(2010)
Diabetes Care
, vol.33
, pp. 676-682
-
-
Metzger, B.E.1
Gabbe, S.G.2
Persson, B.3
Buchanan, T.A.4
Catalano, P.A.5
|