메뉴 건너뛰기




Volumn 23, Issue 9, 2016, Pages 1004-1013

The Use of Very Low Concentrations of High-sensitivity Troponin T to Rule Out Acute Myocardial Infarction Using a Single Blood Test

(25)  Body, Richard a,b   Mueller, Christian c   Giannitsis, Evangelos d   Christ, Michael e   Ordonez Llanos, Jorge f   de Filippi, Christopher R g   Nowak, Richard h   Panteghini, Mauro i   Jernberg, Tomas j   Plebani, Mario k   Verschuren, Franck l   French, John K m   Christenson, Robert g   Weiser, Silvia n   Bendig, Garnet n   Dilba, Peter n   Lindahl, Bertil o   Nowak, Richard M p   Horner, Daniel p   Dolci, Alberto p   more..


Author keywords

[No Author keywords available]

Indexed keywords

TROPONIN I; TROPONIN T;

EID: 84986596660     PISSN: 10696563     EISSN: 15532712     Source Type: Journal    
DOI: 10.1111/acem.13012     Document Type: Article
Times cited : (65)

References (17)
  • 1
    • 84856068587 scopus 로고    scopus 로고
    • Analytical characteristics of high-sensitivity cardiac troponin assays
    • Apple FS, Collinson PO; IFCC Task Force on Clinical Applications of Cardiac Biomarkers. Analytical characteristics of high-sensitivity cardiac troponin assays. Clin Chem 2011;58:54–61.
    • (2011) Clin Chem , vol.58 , pp. 54-61
    • Apple, F.S.1    Collinson, P.O.2
  • 2
    • 69349099937 scopus 로고    scopus 로고
    • Early diagnosis of myocardial infarction with sensitive cardiac troponin assays
    • Reichlin T, Hochholzer W, Bassetti S, et al. Early diagnosis of myocardial infarction with sensitive cardiac troponin assays. N Engl J Med 2009;361:858–67.
    • (2009) N Engl J Med , vol.361 , pp. 858-867
    • Reichlin, T.1    Hochholzer, W.2    Bassetti, S.3
  • 3
    • 84867362492 scopus 로고    scopus 로고
    • Third universal definition of myocardial infarction
    • Thygesen K, Alpert JS, Jaffe AS, et al. Third universal definition of myocardial infarction. J Am Coll Cardiol 2012;60:1581–98.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1581-1598
    • Thygesen, K.1    Alpert, J.S.2    Jaffe, A.S.3
  • 4
    • 67649370543 scopus 로고    scopus 로고
    • Limit of blank, limit of detection and limit of quantitation
    • Armbruster D, Pry T. Limit of blank, limit of detection and limit of quantitation. Clin Biochem Rev 2008;29(Suppl 1):S49–S52.
    • (2008) Clin Biochem Rev , vol.29 , pp. S49-S52
    • Armbruster, D.1    Pry, T.2
  • 5
    • 84921908439 scopus 로고    scopus 로고
    • Diagnostic accuracy of single baseline measurement of Elecsys troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis
    • Zhelev Z, Hyde C, Youngman E, et al. Diagnostic accuracy of single baseline measurement of Elecsys troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ 2015;350:h15–h15.
    • (2015) BMJ , vol.350 , pp. h15
    • Zhelev, Z.1    Hyde, C.2    Youngman, E.3
  • 6
    • 84902138306 scopus 로고    scopus 로고
    • Undetectable high sensitivity troponin T level in the emergency department and risk of myocardial infarction
    • Bandstein N, Ljung R, Johansson M, Holzmann MJ. Undetectable high sensitivity troponin T level in the emergency department and risk of myocardial infarction. J Am Coll Cardiol 2014;63:2569–78.
    • (2014) J Am Coll Cardiol , vol.63 , pp. 2569-2578
    • Bandstein, N.1    Ljung, R.2    Johansson, M.3    Holzmann, M.J.4
  • 7
    • 84937417944 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin t concentrations below the limit of detection to exclude acute myocardial infarction: a prospective evaluation
    • Body R, Burrows G, Carley S, et al. High-sensitivity cardiac troponin t concentrations below the limit of detection to exclude acute myocardial infarction: a prospective evaluation. Clin Chem 2015;61:983–9.
    • (2015) Clin Chem , vol.61 , pp. 983-989
    • Body, R.1    Burrows, G.2    Carley, S.3
  • 8
    • 84970005872 scopus 로고    scopus 로고
    • Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction using high-sensitivity cardiac troponin T
    • [Epub ahead of print]
    • Mueller C, Giannitsis E, Christ M, et al. Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction using high-sensitivity cardiac troponin T. Ann Emerg Med 2016 [Epub ahead of print].
    • (2016) Ann Emerg Med
    • Mueller, C.1    Giannitsis, E.2    Christ, M.3
  • 9
    • 0034690309 scopus 로고    scopus 로고
    • Missed diagnoses of acute cardiac ischaemia in the emergency department
    • Pope JH, Aufderheide TP, Ruthazer R, et al. Missed diagnoses of acute cardiac ischaemia in the emergency department. N Engl J Med 2000;342:1163–70.
    • (2000) N Engl J Med , vol.342 , pp. 1163-1170
    • Pope, J.H.1    Aufderheide, T.P.2    Ruthazer, R.3
  • 10
    • 84555195443 scopus 로고    scopus 로고
    • Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction
    • Keller T, Zeller T, Ojeda F, et al. Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. JAMA 2011;306:2684–93.
    • (2011) JAMA , vol.306 , pp. 2684-2693
    • Keller, T.1    Zeller, T.2    Ojeda, F.3
  • 11
    • 84971619896 scopus 로고    scopus 로고
    • 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation
    • Roffi M, Patrono C, Collet JP, et al. 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J 2016;37:267–315.
    • (2016) Eur Heart J , vol.37 , pp. 267-315
    • Roffi, M.1    Patrono, C.2    Collet, J.P.3
  • 12
    • 84866103717 scopus 로고    scopus 로고
    • One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
    • Reichlin T, Schindler C, Drexler B, et al. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Arch Intern Med 2012;172:1211–8.
    • (2012) Arch Intern Med , vol.172 , pp. 1211-1218
    • Reichlin, T.1    Schindler, C.2    Drexler, B.3
  • 13
    • 33645052177 scopus 로고    scopus 로고
    • The association between hospital overcrowding and mortality among patients admitted via Western Australian emergency departments
    • Spirivulis PC, Da Silva JA, Jacobs IG, Frazer AR, Jelinek GA. The association between hospital overcrowding and mortality among patients admitted via Western Australian emergency departments. Med J Austral 2006;184:208–12.
    • (2006) Med J Austral , vol.184 , pp. 208-212
    • Spirivulis, P.C.1    Da Silva, J.A.2    Jacobs, I.G.3    Frazer, A.R.4    Jelinek, G.A.5
  • 14
    • 84861607690 scopus 로고    scopus 로고
    • 2-hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker
    • Than M, Cullen L, Aldous S, et al. 2-hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker. J Am Coll Cardiol 2012;59:2091–8.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2091-2098
    • Than, M.1    Cullen, L.2    Aldous, S.3
  • 15
    • 80053394975 scopus 로고    scopus 로고
    • Can the HEART score safely reduce stress testing and cardiac imaging in patients at low risk for major adverse cardiac events?
    • Mahler SA, Hiestand BC, Goff DC, Hoekstra JW, Miller CD. Can the HEART score safely reduce stress testing and cardiac imaging in patients at low risk for major adverse cardiac events? Crit Pathw Cardiol 2011;10:128–33.
    • (2011) Crit Pathw Cardiol , vol.10 , pp. 128-133
    • Mahler, S.A.1    Hiestand, B.C.2    Goff, D.C.3    Hoekstra, J.W.4    Miller, C.D.5
  • 16
    • 84879921302 scopus 로고    scopus 로고
    • What is an acceptable risk of major adverse cardiac event in chest pain patients soon after discharge from the emergency department?
    • Than M, Herbert M, Flaws D, et al. What is an acceptable risk of major adverse cardiac event in chest pain patients soon after discharge from the emergency department? Int J Cardiol 2013;166:752–4.
    • (2013) Int J Cardiol , vol.166 , pp. 752-754
    • Than, M.1    Herbert, M.2    Flaws, D.3
  • 17
    • 84960327828 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study
    • Shah AS, Anand A, Sandoval Y, et al. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet 2015;386:2481–8.
    • (2015) Lancet , vol.386 , pp. 2481-2488
    • Shah, A.S.1    Anand, A.2    Sandoval, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.