메뉴 건너뛰기




Volumn 33, Issue 9, 2016, Pages 638-644

Preload dependency determines the effects of phenylephrine on cardiac output in anaesthetised patients

Author keywords

[No Author keywords available]

Indexed keywords

PHENYLEPHRINE; PROPOFOL; REMIFENTANIL; VASOCONSTRICTOR AGENT;

EID: 84982851432     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0000000000000470     Document Type: Article
Times cited : (51)

References (37)
  • 1
    • 84883257383 scopus 로고    scopus 로고
    • Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: Toward an empirical definition of hypotension
    • Walsh M, Devereaux PJ, Garg AX, et al. Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: toward an empirical definition of hypotension. Anesthesiology 2013; 119:507-515.
    • (2013) Anesthesiology , vol.119 , pp. 507-515
    • Walsh, M.1    Devereaux, P.J.2    Garg, A.X.3
  • 2
    • 0027303116 scopus 로고
    • Hemodynamic and oxygen transport responses in survivors and nonsurvivors of high-risk surgery
    • Shoemaker WC, Appel PL, Kram HB. Hemodynamic and oxygen transport responses in survivors and nonsurvivors of high-risk surgery. Critical Care Med 1993; 21:977-990.
    • (1993) Critical Care Med , vol.21 , pp. 977-990
    • Shoemaker, W.C.1    Appel, P.L.2    Kram, H.B.3
  • 3
    • 79953227040 scopus 로고    scopus 로고
    • Early determinants of death due to multiple organ failure after noncardiac surgery in high-risk patients
    • Lobo SM, Rezende E, Knibel MF, et al. Early determinants of death due to multiple organ failure after noncardiac surgery in high-risk patients. Anesth Analg 2011; 112:877-883.
    • (2011) Anesth Analg , vol.112 , pp. 877-883
    • Lobo, S.M.1    Rezende, E.2    Knibel, M.F.3
  • 4
    • 79961027720 scopus 로고    scopus 로고
    • The clinical implications of isolated alpha(1) adrenergic stimulation
    • Thiele RH, Nemergut EC, Lynch C 3rd. The clinical implications of isolated alpha(1) adrenergic stimulation. Anesth Analg 2011; 113:297-304.
    • (2011) Anesth Analg , vol.113 , pp. 297-304
    • Thiele, R.H.1    Nemergut, E.C.2    Lynch, C.3
  • 5
    • 79961020663 scopus 로고    scopus 로고
    • The physiologic implications of isolated alpha(1) adrenergic stimulation
    • Thiele RH, Nemergut EC, Lynch C 3rd. The physiologic implications of isolated alpha(1) adrenergic stimulation. Anesth Analg 2011; 113: 284-296.
    • (2011) Anesth Analg , vol.113 , pp. 284-296
    • Thiele, R.H.1    Nemergut, E.C.2    Lynch, C.3
  • 6
    • 79961057496 scopus 로고    scopus 로고
    • Phenylephrine and tangible bias
    • Magder S. Phenylephrine and tangible bias. Anesth Analg 2011; 113:211-213.
    • (2011) Anesth Analg , vol.113 , pp. 211-213
    • Magder, S.1
  • 7
    • 0842344866 scopus 로고
    • Ventricular function. I. Starling?s law of the heart studied by means of simultaneous right and left ventricular function curves in the dog
    • Sarnoff SJ, Berglund E. Ventricular function. I. Starling?s law of the heart studied by means of simultaneous right and left ventricular function curves in the dog. Circulation 1954; 9:706-718.
    • (1954) Circulation , vol.9 , pp. 706-718
    • Sarnoff, S.J.1    Berglund, E.2
  • 8
    • 84864252612 scopus 로고    scopus 로고
    • Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship
    • Cannesson M, Jian Z, Chen G, et al. Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol 2012; 113:281-289.
    • (2012) J Appl Physiol , vol.113 , pp. 281-289
    • Cannesson, M.1    Jian, Z.2    Chen, G.3
  • 9
    • 35848948166 scopus 로고    scopus 로고
    • STROBE initiative: The strengthening the reporting of observational studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies
    • Von Elm E, Altman DG, Egger M, et al. STROBE Initiative: The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Ann Intern Med 2007; 147:573-577.
    • (2007) Ann Intern Med , vol.147 , pp. 573-577
    • Von Elm, E.1    Altman, D.G.2    Egger, M.3
  • 10
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162:134-138.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3
  • 11
    • 77953297681 scopus 로고    scopus 로고
    • Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: A clinical study
    • Wyler von Ballmoos M, Takala J, Roeck M, et al. Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study. Crit Care 2010; 14:R11.
    • (2010) Crit Care , vol.14 , pp. R11
    • Wyler Von Ballmoos, M.1    Takala, J.2    Roeck, M.3
  • 12
    • 79954517215 scopus 로고    scopus 로고
    • Respiratory systolic variation test in acutely impaired cardiac function for predicting volume responsiveness in pigs
    • Eichhorn V, Trepte C, Richter HP, et al. Respiratory systolic variation test in acutely impaired cardiac function for predicting volume responsiveness in pigs. Br J Anaesth 2011; 106:659-664.
    • (2011) Br J Anaesth , vol.106 , pp. 659-664
    • Eichhorn, V.1    Trepte, C.2    Richter, H.P.3
  • 13
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume
    • De Backer D, Heenen S, Piagnerelli M, et al. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005; 31:517-523.
    • (2005) Intensive Care Med , vol.31 , pp. 517-523
    • De Backer, D.1    Heenen, S.2    Piagnerelli, M.3
  • 14
    • 65549167377 scopus 로고    scopus 로고
    • Influence of respiratory rate on stroke volume variation in mechanically ventilated patients
    • De Backer D, Taccone FS, Holsten R, et al. Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology 2009; 110:1092-1097.
    • (2009) Anesthesiology , vol.110 , pp. 1092-1097
    • De Backer, D.1    Taccone, F.S.2    Holsten, R.3
  • 15
    • 78651494522 scopus 로고    scopus 로고
    • Pulse pressure variation and stroke volume variation during increased intra-Abdominal pressure: An experimental study
    • Jacques D, Bendjelid K, Duperret S, et al. Pulse pressure variation and stroke volume variation during increased intra-Abdominal pressure: an experimental study. Crit Care 2011; 15:R33.
    • (2011) Crit Care , vol.15 , pp. R33
    • Jacques, D.1    Bendjelid, K.2    Duperret, S.3
  • 16
    • 84055160934 scopus 로고    scopus 로고
    • Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance
    • Monnet X, Bleibtreu A, FerréA, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med 2012; 40:152-157.
    • (2012) Crit Care Med , vol.40 , pp. 152-157
    • Monnet, X.1    Bleibtreu, A.2    Ferré, A.3
  • 17
    • 64149105298 scopus 로고    scopus 로고
    • Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions
    • De Waal EEC, Rex S, Kruitwagen CLJJ, et al. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009; 37:510-515.
    • (2009) Crit Care Med , vol.37 , pp. 510-515
    • De Waal, E.E.C.1    Rex, S.2    Kruitwagen, C.L.J.J.3
  • 18
    • 80053322000 scopus 로고    scopus 로고
    • Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: A 'gray zone' approach
    • Cannesson M, Le Manach Y, Hofer CK, et al. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a 'gray zone' approach. Anesthesiology 2011; 115: 231-241.
    • (2011) Anesthesiology , vol.115 , pp. 231-241
    • Cannesson, M.1    Le Manach, Y.2    Hofer, C.K.3
  • 19
    • 84880541111 scopus 로고    scopus 로고
    • Effect of phenylephrine on the haemodynamic state and cerebral oxygen saturation during anaesthesia in the upright position
    • Soeding PF, Hoy S, Hoy G, et al. Effect of phenylephrine on the haemodynamic state and cerebral oxygen saturation during anaesthesia in the upright position. Br J Anaesth 2013; 111:229-234.
    • (2013) Br J Anaesth , vol.111 , pp. 229-234
    • Soeding, P.F.1    Hoy, S.2    Hoy, G.3
  • 20
    • 84859866465 scopus 로고    scopus 로고
    • Impact of phenylephrine administration on cerebral tissue oxygen saturation and blood volume is modulated by carbon dioxide in anaesthetized patients
    • Meng L, Gelb AW, Alexander BS, et al. Impact of phenylephrine administration on cerebral tissue oxygen saturation and blood volume is modulated by carbon dioxide in anaesthetized patients. Br J Anaesth 2012; 108:815-822.
    • (2012) Br J Anaesth , vol.108 , pp. 815-822
    • Meng, L.1    Gelb, A.W.2    Alexander, B.S.3
  • 21
    • 80053301861 scopus 로고    scopus 로고
    • The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal doppler cardiac output measurements
    • Meng L, Tran NP, Brenton A, et al. The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal doppler cardiac output measurements. Anesth Analg 2011; 113:751-757.
    • (2011) Anesth Analg , vol.113 , pp. 751-757
    • Meng, L.1    Tran, N.P.2    Brenton, A.3
  • 22
    • 79960476429 scopus 로고    scopus 로고
    • Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients
    • Meng L, Cannesson M, Alexander BS, et al. Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients. Br J Anaesth 2011; 107:209-217.
    • (2011) Br J Anaesth , vol.107 , pp. 209-217
    • Meng, L.1    Cannesson, M.2    Alexander, B.S.3
  • 23
    • 84872089977 scopus 로고    scopus 로고
    • Cardiac output response to norepinephrine in postoperative cardiac surgery patients: Interpretation with venous return and cardiac function curves
    • Maas JJ, Pinsky MR, de Wilde RB, et al. Cardiac output response to norepinephrine in postoperative cardiac surgery patients: interpretation with venous return and cardiac function curves. Crit Care Med 2013; 41:143-150.
    • (2013) Crit Care Med , vol.41 , pp. 143-150
    • Maas, J.J.1    Pinsky, M.R.2    De Wilde, R.B.3
  • 24
    • 43249108643 scopus 로고    scopus 로고
    • Low systemic vascular resistance state following off-pump coronary artery bypass grafting
    • Matsuura K, Imamaki M, Ishida A, et al. Low systemic vascular resistance state following off-pump coronary artery bypass grafting. Ann Thorac Cardiovasc Surg 2008; 14:15-21.
    • (2008) Ann Thorac Cardiovasc Surg , vol.14 , pp. 15-21
    • Matsuura, K.1    Imamaki, M.2    Ishida, A.3
  • 25
    • 77954968530 scopus 로고    scopus 로고
    • Early administration of norepinephrine increases cardiac preload and cardiac output in septic patients with life-Threatening hypotension
    • Hamzaoui O, Georger JF, Monnet X, et al. Early administration of norepinephrine increases cardiac preload and cardiac output in septic patients with life-Threatening hypotension. Crit Care 2010; 14:R142.
    • (2010) Crit Care , vol.14 , pp. R142
    • Hamzaoui, O.1    Georger, J.F.2    Monnet, X.3
  • 26
    • 0023215903 scopus 로고
    • Transesophageal Doppler scanning versus thermodilution during general anesthesia. An initial comparison of cardiac output techniques
    • Freund PR. Transesophageal Doppler scanning versus thermodilution during general anesthesia. An initial comparison of cardiac output techniques. Am J Surg 1986; 153:490-494.
    • (1986) Am J Surg , vol.153 , pp. 490-494
    • Freund, P.R.1
  • 27
    • 67849110105 scopus 로고    scopus 로고
    • Perioperative hemodynamic monitoring with transesophageal Doppler technology
    • Schober P, Loer SA, Schwarte LA. Perioperative hemodynamic monitoring with transesophageal Doppler technology. Anesth Analg 2009; 109:340-353.
    • (2009) Anesth Analg , vol.109 , pp. 340-353
    • Schober, P.1    Loer, S.A.2    Schwarte, L.A.3
  • 28
    • 72449160043 scopus 로고    scopus 로고
    • Transesophageal Doppler devices: A technical review
    • Schober P, Loer SA, Schwarte LA. Transesophageal Doppler devices: a technical review. J Clin Monit Comput 2009; 23:391-401.
    • (2009) J Clin Monit Comput , vol.23 , pp. 391-401
    • Schober, P.1    Loer, S.A.2    Schwarte, L.A.3
  • 29
    • 0033939067 scopus 로고    scopus 로고
    • Esophageal Doppler monitor determinations of cardiacoutput and preload during cardiac operations
    • Dicorte CJ, Latham P, Greilich PE, et al. Esophageal Doppler monitor determinations of cardiacoutput and preload during cardiac operations. Ann Thorac Surg 2000; 69:1782-1786.
    • (2000) Ann Thorac Surg , vol.69 , pp. 1782-1786
    • Dicorte, C.J.1    Latham, P.2    Greilich, P.E.3
  • 30
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, et al. Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007; 99:343-348.
    • (2007) Br J Anaesth , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3
  • 31
    • 34948909129 scopus 로고    scopus 로고
    • Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
    • Lopes MR, Oliveira MA, Pereira VO, et al. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 2007; 11:R100.
    • (2007) Crit Care , vol.11 , pp. R100
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.3
  • 32
    • 34250341289 scopus 로고    scopus 로고
    • Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload
    • Kubitz JC, Annecke T, Forkl S, et al. Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload. Br J Anaesth 2007; 98:591-597.
    • (2007) Br J Anaesth , vol.98 , pp. 591-597
    • Kubitz, J.C.1    Annecke, T.2    Forkl, S.3
  • 33
    • 33646577770 scopus 로고    scopus 로고
    • Passive leg raising predicts fluid responsiveness in the critically ill
    • Monnet X, Rienzo M, Osman D, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006; 34:1402-1407.
    • (2006) Crit Care Med , vol.34 , pp. 1402-1407
    • Monnet, X.1    Rienzo, M.2    Osman, D.3
  • 34
    • 79953221766 scopus 로고    scopus 로고
    • Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients
    • Monnet X, Jabot J, Maizel J, et al. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med 2011; 39:689-694.
    • (2011) Crit Care Med , vol.39 , pp. 689-694
    • Monnet, X.1    Jabot, J.2    Maizel, J.3
  • 35
    • 84860754347 scopus 로고    scopus 로고
    • Comparison of equipressor doses of norepinephrine, epinephrine, and phenylephrine on septic myocardial dysfunction
    • Ducrocq N, Kimmoun A, Furmaniuk A, et al. Comparison of equipressor doses of norepinephrine, epinephrine, and phenylephrine on septic myocardial dysfunction. Anesthesiology 2012; 116:1083-1091.
    • (2012) Anesthesiology , vol.116 , pp. 1083-1091
    • Ducrocq, N.1    Kimmoun, A.2    Furmaniuk, A.3
  • 36
    • 62549112546 scopus 로고    scopus 로고
    • Effects of phenylephrine on the sublingual microcirculation during cardiopulmonary bypass
    • Maier S, Hasibeder WR, Hengl C, et al. Effects of phenylephrine on the sublingual microcirculation during cardiopulmonary bypass. Br J Anaesth 2009; 102:485-491.
    • (2009) Br J Anaesth , vol.102 , pp. 485-491
    • Maier, S.1    Hasibeder, W.R.2    Hengl, C.3
  • 37
    • 84937867587 scopus 로고    scopus 로고
    • Differential effects of phenylephrine and norepinephrine on peripheral tissue oxygenation during general anaesthesia: A randomised controlled trial
    • Poterman M, Vos JJ, Vereecke HE, et al. Differential effects of phenylephrine and norepinephrine on peripheral tissue oxygenation during general anaesthesia: a randomised controlled trial. Eur J Anaesthesiol 2015; 32:571-580.
    • (2015) Eur J Anaesthesiol , vol.32 , pp. 571-580
    • Poterman, M.1    Vos, J.J.2    Vereecke, H.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.