메뉴 건너뛰기




Volumn 9720, Issue , 2016, Pages

Imaging flow cytometer using computation and spatially coded filter

Author keywords

flow cytometer; fluorescence; high throughput; imaging; microfluidic; PMT; spatial temporal transformation

Indexed keywords

BANDPASS FILTERS; BIG DATA; CELLS; CYTOLOGY; FLUORESCENCE; IMAGING TECHNIQUES; LIGHT SCATTERING; MEDICAL IMAGING; MICROFLUIDICS; PHOTOMULTIPLIERS; SPECTROSCOPY; THROUGHPUT;

EID: 84982083036     PISSN: 0277786X     EISSN: 1996756X     Source Type: Conference Proceeding    
DOI: 10.1117/12.2209401     Document Type: Conference Paper
Times cited : (3)

References (30)
  • 2
    • 0019828253 scopus 로고
    • Clinical application of flow cytometry: A review
    • Laerum, O. D., Farsund, T. Clinical application of flow cytometry: a review., Cytometry 2:1-13 (1981).
    • (1981) Cytometry , vol.2 , pp. 1-13
    • Laerum, O.D.1    Farsund, T.2
  • 3
    • 0004199763 scopus 로고
    • (ed Rost, F.) Ch. 9 Cambridge University
    • Rost, F. in Fluorescence microscopy, Vol. 2 (ed Rost, F.) Ch. 9, 1-15 (Cambridge University, 1995).
    • (1995) Fluorescence Microscopy , vol.2 , pp. 1-15
    • Rost, F.1
  • 4
    • 36549058721 scopus 로고    scopus 로고
    • High throughput microscopy: From raw images to discoveries
    • Wollman, R., Stuurman, N. High throughput microscopy: from raw images to discoveries., Journal of Cell Science 120:3715-3722 (2007).
    • (2007) Journal of Cell Science , vol.120 , pp. 3715-3722
    • Wollman, R.1    Stuurman, N.2
  • 6
    • 79955142086 scopus 로고    scopus 로고
    • Review Article: Recent advancements in optofluidic flow cytometer
    • Cho, S. H. et al. Review Article: Recent advancements in optofluidic flow cytometer., Biomicrofluidics 4:043001 (2010).
    • (2010) Biomicrofluidics , vol.4 , pp. 043001
    • Cho, S.H.1
  • 7
    • 84863938828 scopus 로고    scopus 로고
    • High-Throughput single-microparticle imaging flow analyzer
    • Goda, K. et al. High-throughput single-microparticle imaging flow analyzer., Proc Nati Acad Sci USA 109:11630-11635 (2012).
    • (2012) Proc Nati Acad Sci USA , vol.109 , pp. 11630-11635
    • Goda, K.1
  • 8
    • 77953099930 scopus 로고    scopus 로고
    • Human mammalian cell sorting using a highly integrated micro-fabricated fluorescence-activated cell sorter (?FACS)
    • Cho, S. H., Chen, C. H., Tsai, F. S., Godin, J. M., Lo, Y. H. Human mammalian cell sorting using a highly integrated micro-fabricated fluorescence-activated cell sorter (?FACS)., Lab Chip 10:1567-1573 (2010).
    • (2010) Lab Chip , vol.10 , pp. 1567-1573
    • Cho, S.H.1    Chen, C.H.2    Tsai, F.S.3    Godin, J.M.4    Lo, Y.H.5
  • 11
    • 70549106578 scopus 로고    scopus 로고
    • Microfluidic cell sorter with integrated piezoelectric actuator
    • Chen, C. H., Cho, S. H., Tsai, F., Erten, A., Lo, Y. H. Microfluidic cell sorter with integrated piezoelectric actuator., Biomedical Microdevices 11:1223-1231 (2009).
    • (2009) Biomedical Microdevices , vol.11 , pp. 1223-1231
    • Chen, C.H.1    Cho, S.H.2    Tsai, F.3    Erten, A.4    Lo, Y.H.5
  • 12
    • 84885021376 scopus 로고    scopus 로고
    • Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy
    • Diebold, E. D., Buckley, B. W., Gossett, D. R., Jalali, B. Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy., Nature Photonics 7:806-810 (2013).
    • (2013) Nature Photonics , vol.7 , pp. 806-810
    • Diebold, E.D.1    Buckley, B.W.2    Gossett, D.R.3    Jalali, B.4
  • 13
    • 82855165074 scopus 로고    scopus 로고
    • Strategies for implementing hardware-assisted high-throughput cellular image analysis
    • Tse, H. T. K. et al. Strategies for implementing hardware-assisted high-throughput cellular image analysis., J Lab Automation 16:422-430 (2011).
    • (2011) J Lab Automation , vol.16 , pp. 422-430
    • Tse, H.T.K.1
  • 15
    • 79955612530 scopus 로고    scopus 로고
    • A parrallel microfluidic cytometer for highcontent screening
    • McKenna, B. K., Evans, J. G., Cheung, M. C., Ehrlich, D. J. A parrallel microfluidic cytometer for highcontent screening., Nature Methods 8:401-3 (2011).
    • (2011) Nature Methods , vol.8 , pp. 401-403
    • McKenna, B.K.1    Evans, J.G.2    Cheung, M.C.3    Ehrlich, D.J.4
  • 17
    • 84869824905 scopus 로고    scopus 로고
    • Imaging flow cytometry: Coping with heterogeneity in biological systems
    • Barteneva, N. S., Fasler-Kan, E., Vorobjev, I. A. Imaging flow cytometry: coping with heterogeneity in biological systems., J Histochem Cytochem 60:723-733 (2012).
    • (2012) J Histochem Cytochem , vol.60 , pp. 723-733
    • Barteneva, N.S.1    Fasler-Kan, E.2    Vorobjev, I.A.3
  • 18
    • 47349112642 scopus 로고    scopus 로고
    • Quantitative image based apoptotic index measurement using multispectral imaging flow cytometry: A comparison with standard photometric methods
    • Henery, S. et al. Quantitative image based apoptotic index measurement using multispectral imaging flow cytometry: a comparison with standard photometric methods., Apoptosis 13:1054-1063 (2008).
    • (2008) Apoptosis , vol.13 , pp. 1054-1063
    • Henery, S.1
  • 20
    • 70349440973 scopus 로고    scopus 로고
    • Moving Pictures: Imaging flow cytometry for drug development
    • Elliott, G. S. Moving pictures: imaging flow cytometry for drug development., Comb Chem High Throughput Screen 12:849-859 (2009).
    • (2009) Comb Chem High Throughput Screen , vol.12 , pp. 849-859
    • Elliott, G.S.1
  • 21
    • 33646096984 scopus 로고    scopus 로고
    • Quantitative measurement of nuclear translocation events using similarity analysis of multispectral cellular images obtained in flow
    • George, T. C. et al. Quantitative measurement of nuclear translocation events using similarity analysis of multispectral cellular images obtained in flow., J Immunological Methods 311:117-129 (2006).
    • (2006) J Immunological Methods , vol.311 , pp. 117-129
    • George, T.C.1
  • 22
    • 79959722519 scopus 로고    scopus 로고
    • Fully automated on-chip imaging flow cytometry system with disposable contamination-free plastic re-cultivation chip
    • Hayashi, M. et al. Fully automated on-chip imaging flow cytometry system with disposable contamination-free plastic re-cultivation chip., Inter J Molecular Sci 12:3618-3634 (2011).
    • (2011) Inter J Molecular Sci , vol.12 , pp. 3618-3634
    • Hayashi, M.1
  • 23
    • 84939504034 scopus 로고    scopus 로고
    • Imaging cells in flow cytometer using spatial-temporal transformation
    • Han, Y., Lo, Y. H. Imaging cells in flow cytometer using spatial-temporal transformation., Scientific Reports 5:13267 (2015).
    • (2015) Scientific Reports , vol.5 , pp. 13267
    • Han, Y.1    Lo, Y.H.2
  • 24
    • 84877333982 scopus 로고    scopus 로고
    • Microflow cytometers with integrated hydrodynamic focusing
    • Frankowski, M. et al. Microflow cytometers with integrated hydrodynamic focusing., Sensors 13:4674-4693 (2013).
    • (2013) Sensors , vol.13 , pp. 4674-4693
    • Frankowski, M.1
  • 25
    • 0031036984 scopus 로고    scopus 로고
    • Cytometry in cell necrobiology: Analysis of apoptosis and accidental cell death (necrosis)
    • Darzynkiewicz, Z. et al. Cytometry in cell necrobiology: analysis of apoptosis and accidental cell death (necrosis)., Cytometry Part A 27:1-20 (1997).
    • (1997) Cytometry Part A , vol.27 , pp. 1-20
    • Darzynkiewicz, Z.1
  • 26
    • 0000858815 scopus 로고    scopus 로고
    • Optical scattering properties of soft tissue: A discrete particle model
    • Schmitt, J. M., Kumar, G. Optical scattering properties of soft tissue: a discrete particle model., Appl Opt 37:2788-2797 (1998).
    • (1998) Appl Opt , vol.37 , pp. 2788-2797
    • Schmitt, J.M.1    Kumar, G.2
  • 27
    • 0000685442 scopus 로고    scopus 로고
    • Influence of particle size and concentration on the diffuse backscattering of polarized light from tissue phantoms and biological cell suspensions
    • Hielscher, A. H., Mourant, J. R., Bigio, I. J. Influence of particle size and concentration on the diffuse backscattering of polarized light from tissue phantoms and biological cell suspensions., Appl Opt 36:125-135 (1996).
    • (1996) Appl Opt , vol.36 , pp. 125-135
    • Hielscher, A.H.1    Mourant, J.R.2    Bigio, I.J.3
  • 28
    • 0000132287 scopus 로고    scopus 로고
    • Observation of periodic fine structure in reflectance from biological tissue: A new technique for measuring nuclear size distribution
    • Perelman, L. T. et al. Observation of periodic fine structure in reflectance from biological tissue: a new technique for measuring nuclear size distribution., Phys Rev Letters 80:627-630 (1998).
    • (1998) Phys Rev Letters , vol.80 , pp. 627-630
    • Perelman, L.T.1
  • 29
    • 0001530889 scopus 로고    scopus 로고
    • Turbulent nature of refractive-index variations in biological tissue
    • Schmitt, J. M., Kumar, G. Turbulent nature of refractive-index variations in biological tissue., Opt Letters 21:1310-1312 (1996).
    • (1996) Opt Letters , vol.21 , pp. 1310-1312
    • Schmitt, J.M.1    Kumar, G.2
  • 30
    • 84905457034 scopus 로고    scopus 로고
    • A Light-Sheet microscope compatible with mobile devices for label-free intracellular imaging and biosensing
    • Wu, T. F. et al. A light-sheet microscope compatible with mobile devices for label-free intracellular imaging and biosensing., Lab Chip 14:3341-3348 (2014).
    • (2014) Lab Chip , vol.14 , pp. 3341-3348
    • Wu, T.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.