메뉴 건너뛰기




Volumn 10, Issue 7, 2016, Pages 7216-7224

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH

Author keywords

flexible electronics; in situ analysis; multiplexed sensing; system integration; wearable biosensors

Indexed keywords

BIOLOGICAL ORGANS; BODY FLUIDS; CALCIUM; DIAGNOSIS; FLEXIBLE ELECTRONICS; IONIZATION; MASS SPECTROMETRY; PH SENSORS; PRINTED CIRCUIT BOARDS; PRINTED CIRCUITS; SPECTROMETRY; TRANSPORT PROPERTIES; WEARABLE TECHNOLOGY;

EID: 84979946063     PISSN: 19360851     EISSN: 1936086X     Source Type: Journal    
DOI: 10.1021/acsnano.6b04005     Document Type: Article
Times cited : (542)

References (43)
  • 1
    • 0003817665 scopus 로고    scopus 로고
    • Standing Committee on the Scientific Evaluation of Dietary Reference Intakes, Food and Nutritional Board, Institute of Medicine; National Academy Press: Washington, DC
    • Young, V.; Garza, C. Dietary Reference Intakes for Calcium, Phosphorus, Magnesium, Vitamin D and Fluoride. Standing Committee on the Scientific Evaluation of Dietary Reference Intakes, Food and Nutritional Board, Institute of Medicine; National Academy Press: Washington, DC, 1997.
    • (1997) Dietary Reference Intakes for Calcium, Phosphorus, Magnesium, Vitamin D and Fluoride
    • Young, V.1    Garza, C.2
  • 3
    • 0015343751 scopus 로고
    • Metabolic Consequences of Acid-Base Disorders
    • Relman, R. S. Metabolic Consequences of Acid-Base Disorders Kidney Int. 1972, 1, 347-359 10.1038/ki.1972.46
    • (1972) Kidney Int. , vol.1 , pp. 347-359
    • Relman, R.S.1
  • 5
    • 33751329990 scopus 로고    scopus 로고
    • The pH of the Skin Surface and its Impact on the Barrier Function
    • Schmid-Wendtner, M. H.; Korting, H. C. The pH of the Skin Surface and its Impact on the Barrier Function Skin Pharmacol. Physiol. 2006, 19, 296-302 10.1159/000094670
    • (2006) Skin Pharmacol. Physiol. , vol.19 , pp. 296-302
    • Schmid-Wendtner, M.H.1    Korting, H.C.2
  • 6
    • 84978962453 scopus 로고    scopus 로고
    • Wearable Chemical Sensors: Present Challenges and Future Prospects
    • Bandodkar, A. J.; Jeerapan, I.; Wang, J. Wearable Chemical Sensors: Present Challenges and Future Prospects ACS Sens. 2016, 1, 464-482 10.1021/acssensors.6b00250
    • (2016) ACS Sens. , vol.1 , pp. 464-482
    • Bandodkar, A.J.1    Jeerapan, I.2    Wang, J.3
  • 8
    • 84884587418 scopus 로고    scopus 로고
    • User-Interactive Electronic Skin for Instantaneous Pressure Visualization
    • Wang, C.; Hwang, D.; Yu, Z.; Takei, K.; Park, J.; Chen, T.; Ma, B.; Javey, A. User-Interactive Electronic Skin for Instantaneous Pressure Visualization Nat. Mater. 2013, 12, 899-904 10.1038/nmat3711
    • (2013) Nat. Mater. , vol.12 , pp. 899-904
    • Wang, C.1    Hwang, D.2    Yu, Z.3    Takei, K.4    Park, J.5    Chen, T.6    Ma, B.7    Javey, A.8
  • 9
    • 84878731954 scopus 로고    scopus 로고
    • Flexible Polymer Transistors with High Pressure Sensitivity for Application in Electronic Skin and Health Monitoring
    • Schwartz, G.; Tee, B. C. K.; Mei, J.; Appleton, A. L.; Kim, D. H.; Wang, H.; Bao, Z. Flexible Polymer Transistors with High Pressure Sensitivity for Application in Electronic Skin and Health Monitoring Nat. Commun. 2013, 4, 1859 10.1038/ncomms2832
    • (2013) Nat. Commun. , vol.4 , pp. 1859
    • Schwartz, G.1    Tee, B.C.K.2    Mei, J.3    Appleton, A.L.4    Kim, D.H.5    Wang, H.6    Bao, Z.7
  • 13
    • 84924416863 scopus 로고    scopus 로고
    • Flexible and Wearable Human-Interactive Health-Monitoring Devices
    • Takei, K.; Honda, W.; Harada, S.; Arie, T.; Akita, S. Flexible and Wearable Human-Interactive Health-Monitoring Devices Adv. Healthcare Mater. 2015, 4, 487-500 10.1002/adhm.201400546
    • (2015) Adv. Healthcare Mater. , vol.4 , pp. 487-500
    • Takei, K.1    Honda, W.2    Harada, S.3    Arie, T.4    Akita, S.5
  • 15
    • 84905648758 scopus 로고    scopus 로고
    • Stretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat
    • Huang, X.; Liu, Y. H.; Chen, K. L.; Shin, W. J.; Lu, C. J.; Kong, G. W.; Patnaik, D.; Lee, S. H.; Cortes, J. F.; Rogers, J. A. Stretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat Small 2014, 10, 3083-3090 10.1002/smll.201400483
    • (2014) Small , vol.10 , pp. 3083-3090
    • Huang, X.1    Liu, Y.H.2    Chen, K.L.3    Shin, W.J.4    Lu, C.J.5    Kong, G.W.6    Patnaik, D.7    Lee, S.H.8    Cortes, J.F.9    Rogers, J.A.10
  • 16
  • 20
  • 22
    • 77954945205 scopus 로고    scopus 로고
    • A Wearable Electrochemical Sensor for the Real-Time Measurement of Sweat Sodium Concentration
    • Schazmann, B.; Morris, D.; Slater, C.; Beirne, S.; Fay, C.; Reuveny, R.; Moyna, N.; Diamond, D. A Wearable Electrochemical Sensor for the Real-Time Measurement of Sweat Sodium Concentration Anal. Methods 2010, 2, 342-348 10.1039/b9ay00184k
    • (2010) Anal. Methods , vol.2 , pp. 342-348
    • Schazmann, B.1    Morris, D.2    Slater, C.3    Beirne, S.4    Fay, C.5    Reuveny, R.6    Moyna, N.7    Diamond, D.8
  • 26
    • 0030121863 scopus 로고    scopus 로고
    • Fluorescent Fiber-Optic Calcium Sensor for Physiological Measurements
    • Shortreed, M.; Kopelman, R.; Kuhn, M.; Hoyland, B. Fluorescent Fiber-Optic Calcium Sensor for Physiological Measurements Anal. Chem. 1996, 68, 1414-1418 10.1021/ac950944k
    • (1996) Anal. Chem. , vol.68 , pp. 1414-1418
    • Shortreed, M.1    Kopelman, R.2    Kuhn, M.3    Hoyland, B.4
  • 28
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors
    • Bühlmann, P.; Pretsch, E.; Bakker, E. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors Chem. Rev. 1998, 98, 1593-1687 10.1021/cr970113+
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Bühlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 30
    • 19744371528 scopus 로고    scopus 로고
    • Calcium Ion-Selective Electrodes under Galvanostatic Current Control
    • Bedlechowicz, I.; Sokalski, T.; Lewenstamb, A.; Maj-zurawska, M. Calcium Ion-Selective Electrodes under Galvanostatic Current Control Sens. Actuators, B 2005, 108, 836-839 10.1016/j.snb.2004.12.092
    • (2005) Sens. Actuators, B , vol.108 , pp. 836-839
    • Bedlechowicz, I.1    Sokalski, T.2    Lewenstamb, A.3    Maj-Zurawska, M.4
  • 31
    • 0035958310 scopus 로고    scopus 로고
    • Calcium-Selective Electrode Based on Polyaniline Functionalized with Bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate
    • Lindfors, T.; Ivaska, A. Calcium-Selective Electrode Based on Polyaniline Functionalized with Bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate Anal. Chim. Acta 2001, 437, 171-182 10.1016/S0003-2670(01)00996-5
    • (2001) Anal. Chim. Acta , vol.437 , pp. 171-182
    • Lindfors, T.1    Ivaska, A.2
  • 34
    • 84897912832 scopus 로고    scopus 로고
    • A Reference Electrode Based on Polyvinyl Butyral (PVB) Polymer for Decentralized Chemical Measurements
    • Guinovart, T.; Crespo, G. A.; Rius, F. X.; Andrade, F. J. A Reference Electrode Based on Polyvinyl Butyral (PVB) Polymer for Decentralized Chemical Measurements Anal. Chim. Acta 2014, 821, 72-80 10.1016/j.aca.2014.02.028
    • (2014) Anal. Chim. Acta , vol.821 , pp. 72-80
    • Guinovart, T.1    Crespo, G.A.2    Rius, F.X.3    Andrade, F.J.4
  • 35
    • 79957607321 scopus 로고    scopus 로고
    • Exercise-Induced Trace Mineral Element Concentration in Regional versus Whole-Body Wash-Down Sweat
    • Baker, L. B.; Stofan, J. R.; Lukaski, H. C.; Horswill, C. A. Exercise-Induced Trace Mineral Element Concentration in Regional versus Whole-Body Wash-Down Sweat Int. J. Sport Nutr. Exercise Metab. 2011, 21, 233-239
    • (2011) Int. J. Sport Nutr. Exercise Metab. , vol.21 , pp. 233-239
    • Baker, L.B.1    Stofan, J.R.2    Lukaski, H.C.3    Horswill, C.A.4
  • 36
    • 0021675807 scopus 로고
    • The Calcium Hypothesis of Cystic Fibrosis
    • Katz, S.; Schoni, M. H.; Bridges, M. A. The Calcium Hypothesis of Cystic Fibrosis Cell Calcium 1984, 5, 421-440 10.1016/0143-4160(84)90021-6
    • (1984) Cell Calcium , vol.5 , pp. 421-440
    • Katz, S.1    Schoni, M.H.2    Bridges, M.A.3
  • 38
    • 0031037418 scopus 로고    scopus 로고
    • Whole Body Sweat Collection in Humans: An Improved Method with Preliminary Data on Electrolyte Content
    • Shirreffs, S. M.; Maughan, R. J. Whole Body Sweat Collection in Humans: An Improved Method with Preliminary Data on Electrolyte Content J. Appl. Physiol. 1997, 82, 336-341
    • (1997) J. Appl. Physiol. , vol.82 , pp. 336-341
    • Shirreffs, S.M.1    Maughan, R.J.2
  • 39
    • 4644241747 scopus 로고
    • Calcium Ion-Selective Electrode in which a Membrane Contacts Graphite directly
    • Ansaldi, A.; Epstein, S. I. Calcium Ion-Selective Electrode in which a Membrane Contacts Graphite directly Anal. Chem. 1973, 45, 595-596 10.1021/ac60325a015
    • (1973) Anal. Chem. , vol.45 , pp. 595-596
    • Ansaldi, A.1    Epstein, S.I.2
  • 40
    • 0016303955 scopus 로고
    • Interference by Polyamines in the Measurement of Magnesium Ion at Physiological pH with the Divalent Cation-Selective Electrode
    • Kent, P.; Bunce, S. C.; Bailey, R. A.; Aikens, D. A. Interference by Polyamines in the Measurement of Magnesium Ion at Physiological pH with the Divalent Cation-Selective Electrode Anal. Biochem. 1974, 62, 75-80 10.1016/0003-2697(74)90368-6
    • (1974) Anal. Biochem. , vol.62 , pp. 75-80
    • Kent, P.1    Bunce, S.C.2    Bailey, R.A.3    Aikens, D.A.4
  • 41
    • 0036885891 scopus 로고    scopus 로고
    • A Comparative Review of Cutaneous pH
    • Matousek, J. L.; Campbell, K. L. A Comparative Review of Cutaneous pH Adv. Vet. Dermatol. 2002, 13, 293-300 10.1046/j.1365-3164.2002.00312.x
    • (2002) Adv. Vet. Dermatol. , vol.13 , pp. 293-300
    • Matousek, J.L.1    Campbell, K.L.2
  • 42
    • 0032732362 scopus 로고    scopus 로고
    • Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor
    • Suzuki, H.; Shiroishi, H. Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor Anal. Chem. 1999, 71, 5069-5075 10.1021/ac990437t
    • (1999) Anal. Chem. , vol.71 , pp. 5069-5075
    • Suzuki, H.1    Shiroishi, H.2
  • 43
    • 0035352803 scopus 로고    scopus 로고
    • Clinical Skin Temperature Measurement to Predict Incipient Pressure Ulcers
    • Sprigle, S.; Linden, M.; McKenna, D.; Davis, K.; Riordan, B. Clinical Skin Temperature Measurement to Predict Incipient Pressure Ulcers Adv. Skin Wound Care 2001, 14, 133-137 10.1097/00129334-200105000-00010
    • (2001) Adv. Skin Wound Care , vol.14 , pp. 133-137
    • Sprigle, S.1    Linden, M.2    McKenna, D.3    Davis, K.4    Riordan, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.