메뉴 건너뛰기




Volumn 36, Issue 7, 2016, Pages 1244-1256

Comparison of non-invasive MRI measurements of cerebral blood flow in a large multisite cohort

Author keywords

Cerebral blood flow; labeling efficiency; phase contrast magnetic resonance imaging; pseudo continuous arterial spin labeling; semi automated vessel segmentation

Indexed keywords

ADULT; ARTERIAL BLOOD; ARTERY BLOOD FLOW; ARTICLE; BLOOD FLOW VELOCITY; BRAIN BLOOD FLOW; COHORT ANALYSIS; FEMALE; HUMAN; IMAGE PROCESSING; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PHASE CONTRAST MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PSEUDO CONTINUOUS ARTERIAL SPIN LABELING; SPIN LABELING; BRAIN ARTERY; BRAIN CIRCULATION; BRAIN MAPPING; CLINICAL TRIAL; DIAGNOSTIC IMAGING; MAGNETIC RESONANCE ANGIOGRAPHY; MULTICENTER STUDY; PHYSIOLOGY; PROCEDURES;

EID: 84976869027     PISSN: 0271678X     EISSN: 15597016     Source Type: Journal    
DOI: 10.1177/0271678X16646124     Document Type: Article
Times cited : (52)

References (43)
  • 1
    • 77956268844 scopus 로고    scopus 로고
    • MRI estimation of global brain oxygen consumption rate
    • Jain V, Langham MC, and Wehrli FW. MRI estimation of global brain oxygen consumption rate. J Cereb Blood Flow Metab 2010; 30: 1598-1607
    • (2010) J Cereb Blood Flow Metab , vol.30 , pp. 1598-1607
    • Jain, V.1    Langham, M.C.2    Wehrli, F.W.3
  • 2
    • 0001922222 scopus 로고
    • The determination of cerebral blood flow in man by the use of nitrous oxide in low concentrations
    • Kety SS, and Schmidt CF. The determination of cerebral blood flow in man by the use of nitrous oxide in low concentrations. Am J Physiol 1945; 143: 53-66
    • (1945) Am J Physiol , vol.143 , pp. 53-66
    • Kety, S.S.1    Schmidt, C.F.2
  • 3
    • 0021030757 scopus 로고
    • Brain blood flow measured with intravenous H2(15)O i Theory, and error analysis
    • Herscovitch P, Markham J, and Raichle ME. Brain blood flow measured with intravenous H2(15)O. I. Theory, and error analysis. J Nucl Med 1983; 24: 782-789
    • (1983) J Nucl Med , vol.24 , pp. 782-789
    • Herscovitch, P.1    Markham, J.2    Raichle, M.E.3
  • 4
    • 79952952333 scopus 로고    scopus 로고
    • Cerebral blood flow, and the injured brain: How should we monitor, and manipulate it?
    • Dagal A, and Lam AM. Cerebral blood flow, and the injured brain: how should we monitor, and manipulate it?. Curr Opin Anaesthesiol 2011; 24: 131-137
    • (2011) Curr Opin Anaesthesiol , vol.24 , pp. 131-137
    • Dagal, A.1    Lam, A.M.2
  • 5
    • 68449096237 scopus 로고    scopus 로고
    • Arterial spin-labeled perfusion MRI in basic, and clinical neuroscience
    • Detre JA, Wang J, Wang Z, et al. Arterial spin-labeled perfusion MRI in basic, and clinical neuroscience. Curr Opin Neurol 2009; 22: 348-355
    • (2009) Curr Opin Neurol , vol.22 , pp. 348-355
    • Detre, J.A.1    Wang, J.2    Wang, Z.3
  • 6
    • 0026542167 scopus 로고
    • Magnetic resonance imaging of perfusion using spin inversion of arterial water
    • Williams DS, Detre JA, Leigh JS, et al. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci U S A 1992; 89: 212-216
    • (1992) Proc Natl Acad Sci U S A , vol.89 , pp. 212-216
    • Williams, D.S.1    Detre, J.A.2    Leigh, J.S.3
  • 8
    • 0026877346 scopus 로고
    • Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: Accounting for transit time, and cross-relaxation
    • Zhang W, Williams DS, Detre JA, et al. Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: accounting for transit time, and cross-relaxation. Magn Reson Med 1992; 25: 362-371
    • (1992) Magn Reson Med , vol.25 , pp. 362-371
    • Zhang, W.1    Williams, D.S.2    Detre, J.A.3
  • 9
    • 0028395925 scopus 로고
    • Tissue specific perfusion imaging using arterial spin labeling
    • Detre JA, Zhang W, Roberts DA, et al. Tissue specific perfusion imaging using arterial spin labeling. NMR Biomed 1994; 7: 75-82
    • (1994) NMR Biomed , vol.7 , pp. 75-82
    • Detre, J.A.1    Zhang, W.2    Roberts, D.A.3
  • 10
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-Time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, and Detre JA. Reduced transit-Time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996; 16: 1236-1249
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 11
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • Buxton RB, Frank LR, Wong EC, et al. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med 1998; 40: 383-396
    • (1998) Magn Reson Med , vol.40 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3
  • 12
    • 0031848388 scopus 로고    scopus 로고
    • A theoretical, and experimental comparison of continuous, and pulsed arterial spin labeling techniques for quantitative perfusion imaging
    • Wong EC, Buxton RB, and Frank LR. A theoretical, and experimental comparison of continuous, and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magn Reson Med 1998; 40: 348-355
    • (1998) Magn Reson Med , vol.40 , pp. 348-355
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 13
    • 84919839320 scopus 로고    scopus 로고
    • Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group, and the European consortium for ASL in dementia
    • Alsop DC, Detre JA, Golay X, et al. Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group, and the European consortium for ASL in dementia. Magn Reson Med 2015; 73: 102-116
    • (2015) Magn Reson Med , vol.73 , pp. 102-116
    • Alsop, D.C.1    Detre, J.A.2    Golay, X.3
  • 14
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flowdriven inversion for arterial spin labeling using pulsed radio frequency, and gradient fields
    • Dai W, Garcia D, de Bazelaire C, et al. Continuous flowdriven inversion for arterial spin labeling using pulsed radio frequency, and gradient fields. Magn Reson Med 2008; 60: 1488-1497
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.1    Garcia, D.2    De Bazelaire, C.3
  • 15
    • 77649122097 scopus 로고    scopus 로고
    • Estimation of labeling efficiency in pseudocontinuous arterial spin labeling
    • Aslan S, Xu F, Wang PL, et al. Estimation of labeling efficiency in pseudocontinuous arterial spin labeling. Magn Reson Med 2010; 63: 765-771
    • (2010) Magn Reson Med , vol.63 , pp. 765-771
    • Aslan, S.1    Xu, F.2    Wang, P.L.3
  • 16
    • 0036288135 scopus 로고    scopus 로고
    • Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
    • Spilt A, Box FM, Van der Geest RJ, et al. Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging. J Magn Reson Imaging 2002; 16: 1-5
    • (2002) J Magn Reson Imaging , vol.16 , pp. 1-5
    • Spilt, A.1    Box, F.M.2    Van Der Geest, R.J.3
  • 17
    • 0029964887 scopus 로고    scopus 로고
    • Measuring blood flow by nontriggered 2D phase-contrast MR angiography
    • Bakker CJ, Hartkamp MJ, and Mali WP. Measuring blood flow by nontriggered 2D phase-contrast MR angiography. Magn Reson Imaging 1996; 14: 609-614
    • (1996) Magn Reson Imaging , vol.14 , pp. 609-614
    • Bakker, C.J.1    Hartkamp, M.J.2    Mali, W.P.3
  • 18
    • 77956365291 scopus 로고    scopus 로고
    • Multiphase pseudocontinuous arterial spin labeling (MP-PCASL) for robust quantification of cerebral blood flow
    • Jung Y, Wong EC, and Liu TT. Multiphase pseudocontinuous arterial spin labeling (MP-PCASL) for robust quantification of cerebral blood flow. Magn Reson Med 2010; 64: 799-810
    • (2010) Magn Reson Med , vol.64 , pp. 799-810
    • Jung, Y.1    Wong, E.C.2    Liu, T.T.3
  • 19
    • 84875275149 scopus 로고    scopus 로고
    • Comparison of 2D, and 3D single-shot ASL perfusion fMRI sequences
    • Vidorreta M, Wang Z, Rodriguez I, et al.comparison of 2D, and 3D single-shot ASL perfusion fMRI sequences. Neuroimage 2013; 66: 662-671
    • (2013) Neuroimage , vol.66 , pp. 662-671
    • Vidorreta, M.1    Wang, Z.2    Rodriguez, I.3
  • 20
    • 0025056547 scopus 로고
    • Cerebral blood flow, blood volume, and oxygen utilization Normal values, and effect of age
    • Pt 1
    • Leenders KL, Perani D, Lammertsma AA, et al. Cerebral blood flow, blood volume, and oxygen utilization. Normal values, and effect of age. Brain 1990; 113(Pt 1): 27-47
    • (1990) Brain , vol.113 , pp. 27-47
    • Leenders, K.L.1    Perani, D.2    Lammertsma, A.A.3
  • 22
    • 84862502320 scopus 로고    scopus 로고
    • Longitudinal reproducibility, and accuracy of pseudo-continuous arterial spin labeled perfusion MR imaging in typically developing children
    • Jain V, Duda J, Avants B, et al. Longitudinal reproducibility, and accuracy of pseudo-continuous arterial spin labeled perfusion MR imaging in typically developing children. Radiology 2012; 263: 527-536
    • (2012) Radiology , vol.263 , pp. 527-536
    • Jain, V.1    Duda, J.2    Avants, B.3
  • 23
    • 38349131004 scopus 로고    scopus 로고
    • Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx
    • Wang Z, Aguirre GK, Rao H, et al. Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx. Magn Reson Imaging 2008; 26: 261-269
    • (2008) Magn Reson Imaging , vol.26 , pp. 261-269
    • Wang, Z.1    Aguirre, G.K.2    Rao, H.3
  • 24
    • 84868641708 scopus 로고    scopus 로고
    • Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts, and global signal fluctuations
    • Wang Z. Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts, and global signal fluctuations. Magn Reson Imaging 2012; 30: 1409-1415
    • (2012) Magn Reson Imaging , vol.30 , pp. 1409-1415
    • Wang, Z.1
  • 25
    • 15944405346 scopus 로고    scopus 로고
    • Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: Feasibility study
    • Wang J, Zhang Y, Wolf RL, et al. Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: Feasibility study. Radiology 2005; 235: 218-228
    • (2005) Radiology , vol.235 , pp. 218-228
    • Wang, J.1    Zhang, Y.2    Wolf, R.L.3
  • 26
    • 4243184848 scopus 로고    scopus 로고
    • Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
    • Lu H, Clingman C, Golay X, et al. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med 2004; 52: 679-682
    • (2004) Magn Reson Med , vol.52 , pp. 679-682
    • Lu, H.1    Clingman, C.2    Golay, X.3
  • 27
    • 0037371755 scopus 로고    scopus 로고
    • Effects of hematocrit, and oxygen saturation level on blood spin-lattice relaxation
    • Silvennoinen MJ, Kettunen MI, and Kauppinen RA. Effects of hematocrit, and oxygen saturation level on blood spin-lattice relaxation. Magn Reson Med 2003; 49: 568-571
    • (2003) Magn Reson Med , vol.49 , pp. 568-571
    • Silvennoinen, M.J.1    Kettunen, M.I.2    Kauppinen, R.A.3
  • 28
    • 84866512103 scopus 로고    scopus 로고
    • Accuracy, and reliability of automated gray matter segmentation pathways on real, and simulated structural magnetic resonance images of the human brain
    • Eggert LD, Sommer J, Jansen A, et al. Accuracy, and reliability of automated gray matter segmentation pathways on real, and simulated structural magnetic resonance images of the human brain. PloS One 2012; 7: e45081
    • (2012) PloS One , vol.7 , pp. e45081
    • Eggert, L.D.1    Sommer, J.2    Jansen, A.3
  • 29
    • 0036516482 scopus 로고    scopus 로고
    • The problem of functional localization in the human brain
    • Brett M, Johnsrude IS, and Owen AM. The problem of functional localization in the human brain. Nat Rev Neurosci 2002; 3: 243-249
    • (2002) Nat Rev Neurosci , vol.3 , pp. 243-249
    • Brett, M.1    Johnsrude, I.S.2    Owen, A.M.3
  • 30
    • 0036846571 scopus 로고    scopus 로고
    • Method to correct for the effects of limited spatial resolution in phase-contrast flow MRI measurements
    • Lagerstrand KM, Lehmann H, Starck G, et al. Method to correct for the effects of limited spatial resolution in phase-contrast flow MRI measurements. Magn Reson Med 2002; 48: 883-889
    • (2002) Magn Reson Med , vol.48 , pp. 883-889
    • Lagerstrand, K.M.1    Lehmann, H.2    Starck, G.3
  • 31
    • 0029270436 scopus 로고
    • Correction of partial-volume effects in phase-contrast flow measurements
    • Tang C, Blatter DD, and Parker DL. Correction of partial-volume effects in phase-contrast flow measurements. J Magn Reson Imaging 1995; 5: 175-180
    • (1995) J Magn Reson Imaging , vol.5 , pp. 175-180
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 32
    • 0027969245 scopus 로고
    • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography
    • Hamilton CA. Correction of partial volume inaccuracies in quantitative phase contrast MR angiography. Magn Reson Imaging 1994; 12: 1127-1130
    • (1994) Magn Reson Imaging , vol.12 , pp. 1127-1130
    • Hamilton, C.A.1
  • 33
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts, and implementation
    • Lotz J, Meier C, Leppert A, et al. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts, and implementation. Radiographics 2002; 22: 651-671
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3
  • 35
    • 0025967701 scopus 로고
    • A bedside test for cerebral autoregulation using transcranial Doppler ultrasound
    • Giller CA. A bedside test for cerebral autoregulation using transcranial Doppler ultrasound. Acta Neurochir (Wien) 1991; 108: 7-14
    • (1991) Acta Neurochir (Wien) , vol.108 , pp. 7-14
    • Giller, C.A.1
  • 36
    • 0026736678 scopus 로고
    • Rapid autoregulation of cerebral blood flow: A laser-Doppler flowmetry study
    • Florence G, and Seylaz J. Rapid autoregulation of cerebral blood flow: a laser-Doppler flowmetry study. J Cereb Blood Flow Metab 1992; 12: 674-680
    • (1992) J Cereb Blood Flow Metab , vol.12 , pp. 674-680
    • Florence, G.1    Seylaz, J.2
  • 37
    • 33750854607 scopus 로고    scopus 로고
    • Transfer function analysis of dynamic cerebral autoregulation in humans
    • Pt2
    • Zhang R, Zuckerman JH, Giller CA, et al. Transfer function analysis of dynamic cerebral autoregulation in humans. Am J Physiol 1998; 274(1 Pt 2): H233-H241
    • (1998) Am J Physiol , vol.274 , Issue.1 , pp. H233-H241
    • Zhang, R.1    Zuckerman, J.H.2    Giller, C.A.3
  • 38
    • 65549160648 scopus 로고    scopus 로고
    • Physiological modulations in arterial spin labeling perfusion magnetic resonance imaging
    • Wu WC, Edlow BL, Elliot MA, et al. Physiological modulations in arterial spin labeling perfusion magnetic resonance imaging. IEEE Transac Med imaging 2009; 28: 703-709
    • (2009) IEEE Transac Med Imaging , vol.28 , pp. 703-709
    • Wu, W.C.1    Edlow, B.L.2    Elliot, M.A.3
  • 39
    • 0033624185 scopus 로고    scopus 로고
    • H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans
    • Ye FQ, Berman KF, Ellmore T, et al. H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans. Magn Reson Med 2000; 44: 450-456
    • (2000) Magn Reson Med , vol.44 , pp. 450-456
    • Ye, F.Q.1    Berman, K.F.2    Ellmore, T.3
  • 40
    • 77949708300 scopus 로고    scopus 로고
    • Reliability, and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T, and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease
    • Xu G, Rowley HA, Wu GM, et al. Reliability, and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T, and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease. NMR Biomed 2010; 23: 286-293
    • (2010) NMR Biomed , vol.23 , pp. 286-293
    • Xu, G.1    Rowley, H.A.2    Wu, G.M.3
  • 41
    • 84905500255 scopus 로고    scopus 로고
    • Comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography, and arterial spin labeling magnetic resonance imaging
    • Zhang K, Herzog H, Mauler J, et al.comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography, and arterial spin labeling magnetic resonance imaging. J Cereb Blood Flow Metab 2014; 34: 1373-1380
    • (2014) J Cereb Blood Flow Metab , vol.34 , pp. 1373-1380
    • Zhang, K.1    Herzog, H.2    Mauler, J.3
  • 42
    • 79953245746 scopus 로고    scopus 로고
    • Test-retest reliability of arterial spin labeling with common labeling strategies
    • Chen Y, Wang DJ, and Detre JA. Test-retest reliability of arterial spin labeling with common labeling strategies. J Magn Reson Imaging 2011; 33: 940-949
    • (2011) J Magn Reson Imaging , vol.33 , pp. 940-949
    • Chen, Y.1    Wang, D.J.2    Detre, J.A.3
  • 43
    • 84866734160 scopus 로고    scopus 로고
    • Pseudocontinuous arterial spin labeling with optimized tagging efficiency
    • Shin DD, Liu TT, Wong EC, et al. Pseudocontinuous arterial spin labeling with optimized tagging efficiency. Magn Resona Med 2012; 68: 1135-1144
    • (2012) Magn Resona Med , vol.68 , pp. 1135-1144
    • Shin, D.D.1    Liu, T.T.2    Wong, E.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.