메뉴 건너뛰기




Volumn 34, Issue 8, 2014, Pages 1373-1380

Comparison of cerebral blood flow acquired by simultaneous [ 15O]water positron emission tomography and arterial spin labeling magnetic resonance imaging

Author keywords

arterial spin labeling; cerebral blood flow; magnetic resonance imaging; MR PET; positron emission tomography

Indexed keywords

OXYGEN 15; WATER;

EID: 84905500255     PISSN: 0271678X     EISSN: 15597016     Source Type: Journal    
DOI: 10.1038/jcbfm.2014.92     Document Type: Article
Times cited : (128)

References (37)
  • 1
    • 0021030757 scopus 로고
    • Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis
    • Herscovitch P, Markham J, Raichle ME. Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis. J Nucl Med 1983; 24: 782-789.
    • (1983) J Nucl Med , vol.24 , pp. 782-789
    • Herscovitch, P.1    Markham, J.2    Raichle, M.E.3
  • 2
    • 77949708300 scopus 로고    scopus 로고
    • Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease
    • Xu G, Rowley HA, Wu G, Alsop DC, Shankaranarayanan A, Dowling M et al. Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease. NMR Biomed 2010; 23: 286-293.
    • (2010) NMR Biomed , vol.23 , pp. 286-293
    • Xu, G.1    Rowley, H.A.2    Wu, G.3    Alsop, D.C.4    Shankaranarayanan, A.5    Dowling, M.6
  • 3
    • 84875516774 scopus 로고    scopus 로고
    • Comparison of regional cerebral blood flow responses to hypoglycemia using pulsed arterial spin labeling and positron emission tomography
    • Arbelaez AM, Su Y, Thomas JB, Hauch AC, Hershey T, Ances BM. Comparison of regional cerebral blood flow responses to hypoglycemia using pulsed arterial spin labeling and positron emission tomography. PLoS One 2013; 8: e60085.
    • (2013) PLoS One , vol.8
    • Arbelaez, A.M.1    Su, Y.2    Thomas, J.B.3    Hauch, A.C.4    Hershey, T.5    Ances, B.M.6
  • 4
    • 13844276067 scopus 로고    scopus 로고
    • Human brain: Reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging
    • Jahng GH, Song E, Zhu XP, Matson GB, Weiner MW, Schuff N. Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging. Radiology 2005; 234: 909-916.
    • (2005) Radiology , vol.234 , pp. 909-916
    • Jahng, G.H.1    Song, E.2    Zhu, X.P.3    Matson, G.B.4    Weiner, M.W.5    Schuff, N.6
  • 5
    • 22744443729 scopus 로고    scopus 로고
    • Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
    • Gunther M, Oshio K, Feinberg DA. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 2005; 54: 491-498.
    • (2005) Magn Reson Med , vol.54 , pp. 491-498
    • Gunther, M.1    Oshio, K.2    Feinberg, D.A.3
  • 6
    • 73949087194 scopus 로고    scopus 로고
    • Arterial spin labeling perfusion MRI at multiple delay times: A correlative study with (H2O)-O-15 positron emission tomography in patients with symptomatic carotid artery occlusion
    • Bokkers RPH, Bremmer JP, van Berckel BNM, Lammertsma AA, Hendrikse J, Pluim JPW et al. Arterial spin labeling perfusion MRI at multiple delay times: a correlative study with (H2O)-O-15 positron emission tomography in patients with symptomatic carotid artery occlusion. J Cereb Blood Flow Metab 2010; 30: 222-229.
    • (2010) J Cereb Blood Flow Metab , vol.30 , pp. 222-229
    • Bokkers, R.P.H.1    Bremmer, J.P.2    Van Berckel, B.N.M.3    Lammertsma, A.A.4    Hendrikse, J.5    Pluim, J.P.W.6
  • 7
    • 84862062930 scopus 로고    scopus 로고
    • Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography
    • Henriksen OM, Larsson HB, Hansen AE, Gruner JM, Law I, Rostrup E. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography. J Magn Reson Imaging 2012; 35: 1290-1299.
    • (2012) J Magn Reson Imaging , vol.35 , pp. 1290-1299
    • Henriksen, O.M.1    Larsson, H.B.2    Hansen, A.E.3    Gruner, J.M.4    Law, I.5    Rostrup, E.6
  • 8
    • 75749158516 scopus 로고    scopus 로고
    • Arterial transit time effects in pulsed arterial spin labeling CBF mapping: Insight from a PET and MR study in normal human subjects
    • Qiu M, Paul Maguire R, Arora J, Planeta-Wilson B, Weinzimmer D, Wang J et al. Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects. Magn Reson Med 2010; 63: 374-384.
    • (2010) Magn Reson Med , vol.63 , pp. 374-384
    • Qiu, M.1    Paul Maguire, R.2    Arora, J.3    Planeta-Wilson, B.4    Weinzimmer, D.5    Wang, J.6
  • 9
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields
    • Dai WY, Garcia D, de Bazelaire C, Alsop DC. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 2008; 60: 1488-1497.
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.Y.1    Garcia, D.2    De Bazelaire, C.3    Alsop, D.C.4
  • 10
    • 35948969225 scopus 로고    scopus 로고
    • A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
    • Wu WC, Fernandez-Seara M, Detre JA, Wehrli FW, Wang J. A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling. Magn Reson Med 2007; 58: 1020-1027.
    • (2007) Magn Reson Med , vol.58 , pp. 1020-1027
    • Wu, W.C.1    Fernandez-Seara, M.2    Detre, J.A.3    Wehrli, F.W.4    Wang, J.5
  • 12
    • 0033624185 scopus 로고    scopus 로고
    • H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans
    • Ye FQ, Berman KF, Ellmore T, Esposito G, van Horn JD, Yang Y et al. H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans. Magn Reson Med 2000; 44: 450-456.
    • (2000) Magn Reson Med , vol.44 , pp. 450-456
    • Ye, F.Q.1    Berman, K.F.2    Ellmore, T.3    Esposito, G.4    Van Horn, J.D.5    Yang, Y.6
  • 13
    • 0025016510 scopus 로고
    • Caffeine and human cerebral blood flow: A positron emission tomography study
    • Cameron OG, Modell JG, Hariharan M. Caffeine and human cerebral blood flow: a positron emission tomography study. Life Sci 1990; 47: 1141-1146.
    • (1990) Life Sci , vol.47 , pp. 1141-1146
    • Cameron, O.G.1    Modell, J.G.2    Hariharan, M.3
  • 15
    • 84864739396 scopus 로고    scopus 로고
    • Cerebral perfusion differences between drowsy and nondrowsy individuals after acute sleep restriction
    • Poudel GR, Innes CRH, Jones RD. Cerebral perfusion differences between drowsy and nondrowsy individuals after acute sleep restriction. Sleep 2012; 35: 1085-1096.
    • (2012) Sleep , vol.35 , pp. 1085-1096
    • Poudel, G.R.1    Innes, C.R.H.2    Jones, R.D.3
  • 22
    • 77649122097 scopus 로고    scopus 로고
    • Estimation of labeling efficiency in pseudocontinuous arterial spin labeling
    • Aslan S, Xu F, Wang PL, Uh J, Yezhuvath US, van Osch M et al. Estimation of labeling efficiency in pseudocontinuous arterial spin labeling. Magn Reson Med 2010; 63: 765-771.
    • (2010) Magn Reson Med , vol.63 , pp. 765-771
    • Aslan, S.1    Xu, F.2    Wang, P.L.3    Uh, J.4    Yezhuvath, U.S.5    Van Osch, M.6
  • 24
    • 67649185917 scopus 로고    scopus 로고
    • Template based attenuation correction for PET in MR-PET scanners
    • Rota Kops E, Herzog H. Template based attenuation correction for PET in MR-PET scanners. IEEE NSS-MIC Conference Record 2008; 3786-3789.
    • (2008) IEEE NSS-MIC Conference Record , pp. 3786-3789
    • Rota Kops, E.1    Herzog, H.2
  • 25
    • 0036322886 scopus 로고    scopus 로고
    • Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain
    • Tzourio-Mazoyer N, Landeau B, Papathanassiou D, Crivello F, Etard O, Delcroix N et al. Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain. Neuroimage 2002; 15: 273-289.
    • (2002) Neuroimage , vol.15 , pp. 273-289
    • Tzourio-Mazoyer, N.1    Landeau, B.2    Papathanassiou, D.3    Crivello, F.4    Etard, O.5    Delcroix, N.6
  • 26
    • 0021861387 scopus 로고
    • Normal average value of cerebral blood flow in younger adults is 50 ml/100 g/min
    • Lassen NA. Normal average value of cerebral blood flow in younger adults is 50 ml/100 g/min. J Cereb Blood Flow Metab 1985; 5: 347-349.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 347-349
    • Lassen, N.A.1
  • 27
    • 0023430879 scopus 로고
    • Positron emission tomographic measurement of cerebral blood-flow and permeability surface-area product of water using [O-15]water and [C-11]butanol
    • Herscovitch P, Raichle ME, Kilbourn MR, Welch MJ. Positron emission tomographic measurement of cerebral blood-flow and permeability surface-area product of water using [O-15]water and [C-11]butanol. J Cereb Blood Flow Metab 1987; 7: 527-542.
    • (1987) J Cereb Blood Flow Metab , vol.7 , pp. 527-542
    • Herscovitch, P.1    Raichle, M.E.2    Kilbourn, M.R.3    Welch, M.J.4
  • 28
    • 0029967308 scopus 로고    scopus 로고
    • Quantitation of regional cerebral blood flow with 15O-butanol and positron emission tomography in humans
    • Herzog H, Seitz RJ, Tellmann L, Rota Kops E, Julicher F, Schlaug G et al. Quantitation of regional cerebral blood flow with 15O-butanol and positron emission tomography in humans. J Cereb Blood Flow Metab 1996; 16: 645-649.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 645-649
    • Herzog, H.1    Seitz, R.J.2    Tellmann, L.3    Rota Kops, E.4    Julicher, F.5    Schlaug, G.6
  • 29
    • 41849090440 scopus 로고    scopus 로고
    • Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling
    • van Gelderen P, de Zwart JA, Duyn JH. Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling. Magn Reson Med 2008; 59: 788-795.
    • (2008) Magn Reson Med , vol.59 , pp. 788-795
    • Van Gelderen, P.1    De Zwart, J.A.2    Duyn, J.H.3
  • 30
    • 79961003493 scopus 로고    scopus 로고
    • Intra- and multicenter reproducibility of pulsed, continuous and pseudocontinuous arterial spin labeling methods for measuring cerebral perfusion
    • Gevers S, van Osch MJ, Bokkers RP, Kies DA, Teeuwisse WM, Majoie CB et al. Intra- and multicenter reproducibility of pulsed, continuous and pseudocontinuous arterial spin labeling methods for measuring cerebral perfusion. J Cereb Blood Flow Metab 2011; 31: 1706-1715.
    • (2011) J Cereb Blood Flow Metab , vol.31 , pp. 1706-1715
    • Gevers, S.1    Van Osch, M.J.2    Bokkers, R.P.3    Kies, D.A.4    Teeuwisse, W.M.5    Majoie, C.B.6
  • 33
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • Petersen ET, Lim T, Golay X. Model-free arterial spin labeling quantification approach for perfusion MRI. Magn Reson Med 2006; 55: 219-232.
    • (2006) Magn Reson Med , vol.55 , pp. 219-232
    • Petersen, E.T.1    Lim, T.2    Golay, X.3
  • 35
    • 70449240950 scopus 로고
    • Cerebral blood flow and oxygen consumption in man
    • Lassen NA. Cerebral blood flow and oxygen consumption in man. Physiol Rev 1959; 39: 183-238.
    • (1959) Physiol Rev , vol.39 , pp. 183-238
    • Lassen, N.A.1
  • 36
    • 0036714079 scopus 로고    scopus 로고
    • Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography
    • Carroll TJ, Teneggi V, Jobin M, Squassante L, Treyer V, Hany TF et al. Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography. J Cereb Blood Flow Metab 2002; 22: 1149-1156.
    • (2002) J Cereb Blood Flow Metab , vol.22 , pp. 1149-1156
    • Carroll, T.J.1    Teneggi, V.2    Jobin, M.3    Squassante, L.4    Treyer, V.5    Hany, T.F.6
  • 37
    • 0344900036 scopus 로고    scopus 로고
    • Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
    • Floyd TF, Ratcliffe SJ, Wang JJ, Resch B, Detre JA. Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories. J Magn Reson Imaging 2003; 18: 649-655.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 649-655
    • Floyd, T.F.1    Ratcliffe, S.J.2    Wang, J.J.3    Resch, B.4    Detre, J.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.