메뉴 건너뛰기




Volumn 27, Issue 7, 2016, Pages 1285-1288

A Structures for Lossless Ion Manipulations (SLIM) Module for Collision Induced Dissociation

Author keywords

Collision induced dissociation; Conveyor; Ion mobility spectrometry; Ion optics; Manipulation; Peptide fragmentation; rf Confinement

Indexed keywords

AMINO ACIDS; CONVEYORS; DISSOCIATION; EFFICIENCY; PEPTIDES;

EID: 84975740641     PISSN: 10440305     EISSN: 18791123     Source Type: Journal    
DOI: 10.1007/s13361-016-1397-x     Document Type: Article
Times cited : (14)

References (37)
  • 1
    • 70350507226 scopus 로고    scopus 로고
    • Electrospray: from ions in solution to ions in the gas phase, what we know now
    • COI: 1:CAS:528:DC%2BD1MXhsFaqtbfK
    • Kebarle, P., Verkerk, U.H.: Electrospray: from ions in solution to ions in the gas phase, what we know now. Mass Spectrom. Rev. 28, 898–917 (2009)
    • (2009) Mass Spectrom. Rev. , vol.28 , pp. 898-917
    • Kebarle, P.1    Verkerk, U.H.2
  • 2
    • 58149383790 scopus 로고    scopus 로고
    • Quantitative matrix-assisted laser desorption/ionization mass spectrometry
    • COI: 1:CAS:528:DC%2BD1MXotFWisg%3D%3D
    • Duncan, M.W., Roder, H., Hunsucker, S.W.: Quantitative matrix-assisted laser desorption/ionization mass spectrometry. Brief. Funct. Genomic. Proteomic. 7, 355–370 (2008)
    • (2008) Brief. Funct. Genomic. Proteomic. , vol.7 , pp. 355-370
    • Duncan, M.W.1    Roder, H.2    Hunsucker, S.W.3
  • 3
    • 0042854999 scopus 로고    scopus 로고
    • Proteome analysis by mass spectrometry
    • COI: 1:CAS:528:DC%2BD3sXntFSgtrY%3D
    • Ferguson, P.L., Smith, R.D.: Proteome analysis by mass spectrometry. Ann. Rev. Biophys. Biomol. Struct. 32, 399–424 (2003)
    • (2003) Ann. Rev. Biophys. Biomol. Struct. , vol.32 , pp. 399-424
    • Ferguson, P.L.1    Smith, R.D.2
  • 4
    • 84876148755 scopus 로고    scopus 로고
    • Protein analysis by shotgun/bottom-up proteomics
    • COI: 1:CAS:528:DC%2BC3sXjtVClu7g%3D
    • Zhang, Y., Fonslow, B.R., Shan, B., Baek, M.C., Yates III, J.R.: Protein analysis by shotgun/bottom-up proteomics. Chem. Rev. 113, 2343–2394 (2013)
    • (2013) Chem. Rev. , vol.113 , pp. 2343-2394
    • Zhang, Y.1    Fonslow, B.R.2    Shan, B.3    Baek, M.C.4    Yates, J.R.5
  • 6
    • 36749004371 scopus 로고    scopus 로고
    • Top-down MS, a powerful complement to the high capabilities of proteolysis proteomics
    • COI: 1:CAS:528:DC%2BD2sXhsVOnsrnK
    • McLafferty, F.W., Breuker, K., Jin, M., Han, X.M., Infusini, G., Jiang, H., Kong, X.L., Begley, T.P.: Top-down MS, a powerful complement to the high capabilities of proteolysis proteomics. FEBS J. 274, 6256–6268 (2007)
    • (2007) FEBS J. , vol.274 , pp. 6256-6268
    • McLafferty, F.W.1    Breuker, K.2    Jin, M.3    Han, X.M.4    Infusini, G.5    Jiang, H.6    Kong, X.L.7    Begley, T.P.8
  • 7
    • 48349147103 scopus 로고    scopus 로고
    • Top-down identification and characterization of biomolecules by mass spectrometry
    • COI: 1:CAS:528:DC%2BD1cXps1WlsLY%3D
    • Breuker, K., Jin, M., Han, X., Jiang, H., McLafferty, F.W.: Top-down identification and characterization of biomolecules by mass spectrometry. J. Am. Soc. Mass Spectrom. 19, 1045–1053 (2008)
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 1045-1053
    • Breuker, K.1    Jin, M.2    Han, X.3    Jiang, H.4    McLafferty, F.W.5
  • 8
    • 30144438909 scopus 로고    scopus 로고
    • Collision-induced dissociation (CID) of peptides and proteins
    • COI: 1:CAS:528:DC%2BD28XosFeruro%3D
    • Wells, J.M., McLuckey, S.A.: Collision-induced dissociation (CID) of peptides and proteins. Methods Enzymol. 402, 148–185 (2005)
    • (2005) Methods Enzymol. , vol.402 , pp. 148-185
    • Wells, J.M.1    McLuckey, S.A.2
  • 9
    • 84861990380 scopus 로고    scopus 로고
    • Selected reaction monitoring-based proteomics: workflows, potential, pitfalls, and future directions
    • COI: 1:CAS:528:DC%2BC38XotVSrurg%3D
    • Picotti, P., Aebersold, R.: Selected reaction monitoring-based proteomics: workflows, potential, pitfalls, and future directions. Nat. Methods 9, 555–566 (2012)
    • (2012) Nat. Methods , vol.9 , pp. 555-566
    • Picotti, P.1    Aebersold, R.2
  • 10
    • 84869233177 scopus 로고    scopus 로고
    • Parallel reaction monitoring for high resolution and high mass accuracy quantitative, targeted proteomics
    • Peterson, A.C., Russell, J.D., Bailey, D.J., Westphall, M.S., Coon, J.J.: Parallel reaction monitoring for high resolution and high mass accuracy quantitative, targeted proteomics. Mol. Cell. Proteom. 11, 1475–1488 (2012)
    • (2012) Mol. Cell. Proteom. , vol.11 , pp. 1475-1488
    • Peterson, A.C.1    Russell, J.D.2    Bailey, D.J.3    Westphall, M.S.4    Coon, J.J.5
  • 11
    • 84861860481 scopus 로고    scopus 로고
    • Targeted data extraction of the MS/MS spectra generated by data-independent acquisition: a new concept for consistent and accurate proteome analysis
    • Gillet, L.C., Navarro, P., Tate, S., Rost, H., Selevsek, N., Reiter, L., Bonner, R., Aebersold, R.: Targeted data extraction of the MS/MS spectra generated by data-independent acquisition: a new concept for consistent and accurate proteome analysis. Mol. Cell. Proteom. 11, O111 016717 (2012)
    • (2012) Mol. Cell. Proteom , vol.O111 , Issue.16717 , pp. 11
    • Gillet, L.C.1    Navarro, P.2    Tate, S.3    Rost, H.4    Selevsek, N.5    Reiter, L.6    Bonner, R.7    Aebersold, R.8
  • 13
    • 0035872321 scopus 로고    scopus 로고
    • Surface-induced dissociation on a MALDI-ion mobility-orthogonal time-of-flight mass spectrometer: sequencing peptides from an “in-solution” protein digest
    • COI: 1:CAS:528:DC%2BD3MXitlyntb0%3D
    • Stone, E., Gillig, K.J., Ruotolo, B., Fuhrer, K., Gonin, M., Schultz, A., Russell, D.H.: Surface-induced dissociation on a MALDI-ion mobility-orthogonal time-of-flight mass spectrometer: sequencing peptides from an “in-solution” protein digest. Anal. Chem. 73, 2233–2238 (2001)
    • (2001) Anal. Chem. , vol.73 , pp. 2233-2238
    • Stone, E.1    Gillig, K.J.2    Ruotolo, B.3    Fuhrer, K.4    Gonin, M.5    Schultz, A.6    Russell, D.H.7
  • 15
    • 0035417216 scopus 로고    scopus 로고
    • Collision-induced dissociation of mobility-separated ions using an orifice-skimmer cone at the back of a drift tube
    • COI: 1:CAS:528:DC%2BD3MXksFSnu74%3D
    • Lee, Y.J., Hoaglund-Hyzer, C.S., Taraszka, J.A., Zientara, G.A., Counterman, A.E., Clemmer, D.E.: Collision-induced dissociation of mobility-separated ions using an orifice-skimmer cone at the back of a drift tube. Anal. Chem. 73, 3549–3555 (2001)
    • (2001) Anal. Chem. , vol.73 , pp. 3549-3555
    • Lee, Y.J.1    Hoaglund-Hyzer, C.S.2    Taraszka, J.A.3    Zientara, G.A.4    Counterman, A.E.5    Clemmer, D.E.6
  • 16
    • 60549116159 scopus 로고    scopus 로고
    • Ion mobility-mass spectrometer interface for collisional activation of mobility separated ions
    • COI: 1:CAS:528:DC%2BD1cXhsV2rtLbJ
    • Fernandez-Lima, F.A., Becker, C., Gillig, K.J., Russell, W.K., Tichy, S.E., Russell, D.H.: Ion mobility-mass spectrometer interface for collisional activation of mobility separated ions. Anal. Chem. 81, 618–624 (2009)
    • (2009) Anal. Chem. , vol.81 , pp. 618-624
    • Fernandez-Lima, F.A.1    Becker, C.2    Gillig, K.J.3    Russell, W.K.4    Tichy, S.E.5    Russell, D.H.6
  • 18
    • 0242543428 scopus 로고    scopus 로고
    • A split-field drift tube for separation and efficient fragmentation of biomolecular ions
    • COI: 1:CAS:528:DC%2BD3sXnvFWksrg%3D
    • Valentine, S.J., Koeniger, S.L., Clemmer, D.E.: A split-field drift tube for separation and efficient fragmentation of biomolecular ions. Anal. Chem. 75, 6202–6208 (2003)
    • (2003) Anal. Chem. , vol.75 , pp. 6202-6208
    • Valentine, S.J.1    Koeniger, S.L.2    Clemmer, D.E.3
  • 19
  • 20
    • 40249108399 scopus 로고    scopus 로고
    • Simultaneous fragmentation of multiple ions using IMS drift time dependent collision energies
    • COI: 1:CAS:528:DC%2BD1cXjtlWjs7w%3D
    • Baker, E.S., Tang, K.Q., Danielson, W.F., Prior, D.C., Smith, R.D.: Simultaneous fragmentation of multiple ions using IMS drift time dependent collision energies. J. Am. Soc. Mass Spectrom. 19, 411–419 (2008)
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 411-419
    • Baker, E.S.1    Tang, K.Q.2    Danielson, W.F.3    Prior, D.C.4    Smith, R.D.5
  • 21
    • 77955049296 scopus 로고    scopus 로고
    • Characterization of an ion mobility-multiplexed collision-induced dissociation-tandem time-of-flight mass spectrometry approach
    • COI: 1:CAS:528:DC%2BC3cXmtFWlsLs%3D
    • Ibrahim, Y.M., Prior, D.C., Baker, E.S., Smith, R.D., Belov, M.E.: Characterization of an ion mobility-multiplexed collision-induced dissociation-tandem time-of-flight mass spectrometry approach. Int. J. Mass. Spectrom. 293, 34–44 (2010)
    • (2010) Int. J. Mass. Spectrom. , vol.293 , pp. 34-44
    • Ibrahim, Y.M.1    Prior, D.C.2    Baker, E.S.3    Smith, R.D.4    Belov, M.E.5
  • 22
    • 84896909414 scopus 로고    scopus 로고
    • Implementation of dipolar resonant excitation for collision induced dissociation with ion mobility/time-of-flight MS
    • COI: 1:CAS:528:DC%2BC2cXhtlehurg%3D
    • Webb, I.K., Chen, T.C., Danielson, W.F., Ibrahim, Y.M., Tang, K.Q., Anderson, G.A., Smith, R.D.: Implementation of dipolar resonant excitation for collision induced dissociation with ion mobility/time-of-flight MS. J. Am. Soc. Mass Spectrom. 25, 563–571 (2014)
    • (2014) J. Am. Soc. Mass Spectrom. , vol.25 , pp. 563-571
    • Webb, I.K.1    Chen, T.C.2    Danielson, W.F.3    Ibrahim, Y.M.4    Tang, K.Q.5    Anderson, G.A.6    Smith, R.D.7
  • 23
    • 84919790086 scopus 로고    scopus 로고
    • An ion mobility mass spectrometer for investigating photoisomerization and photodissociation of molecular ions
    • COI: 1:STN:280:DC%2BC2Mvjt1agug%3D%3D
    • Adamson, B.D., Coughlan, N.J., Markworth, P.B., Continetti, R.E., Bieske, E.J.: An ion mobility mass spectrometer for investigating photoisomerization and photodissociation of molecular ions. Rev. Sci. Instrum. 85, 123109 (2014)
    • (2014) Rev. Sci. Instrum. , vol.85 , pp. 123109
    • Adamson, B.D.1    Coughlan, N.J.2    Markworth, P.B.3    Continetti, R.E.4    Bieske, E.J.5
  • 25
  • 29
    • 84942626974 scopus 로고    scopus 로고
    • Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch
    • COI: 1:CAS:528:DC%2BC2MXhtlGrsrjE
    • Garimella, S.V., Ibrahim, Y.M., Webb, I.K., Ipsen, A.B., Chen, T.C., Tolmachev, A.V., Baker, E.S., Anderson, G.A., Smith, R.D.: Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch. Analyst 140, 6845–6852 (2015)
    • (2015) Analyst , vol.140 , pp. 6845-6852
    • Garimella, S.V.1    Ibrahim, Y.M.2    Webb, I.K.3    Ipsen, A.B.4    Chen, T.C.5    Tolmachev, A.V.6    Baker, E.S.7    Anderson, G.A.8    Smith, R.D.9
  • 31
    • 79951824824 scopus 로고    scopus 로고
    • Leucine enkephalin—a mass spectrometry standard
    • COI: 1:CAS:528:DC%2BC3MXkt1Siu70%3D
    • Sztaray, J., Memboeuf, A., Drahos, L., Vekey, K.: Leucine enkephalin—a mass spectrometry standard. Mass Spectrom. Rev. 30, 298–320 (2011)
    • (2011) Mass Spectrom. Rev. , vol.30 , pp. 298-320
    • Sztaray, J.1    Memboeuf, A.2    Drahos, L.3    Vekey, K.4
  • 32
    • 33751248265 scopus 로고    scopus 로고
    • Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry
    • COI: 1:CAS:528:DC%2BD28XhtVyntLbO
    • Kelly, R.T., Page, J.S., Luo, Q., Moore, R.J., Orton, D.J., Tang, K., Smith, R.D.: Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry. Anal. Chem. 78, 7796–7801 (2006)
    • (2006) Anal. Chem. , vol.78 , pp. 7796-7801
    • Kelly, R.T.1    Page, J.S.2    Luo, Q.3    Moore, R.J.4    Orton, D.J.5    Tang, K.6    Smith, R.D.7
  • 33
    • 34250713877 scopus 로고    scopus 로고
    • Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures
    • COI: 1:CAS:528:DC%2BD2sXntF2lsrc%3D
    • Baker, E.S., Clowers, B.H., Li, F.M., Tang, K., Tolmachev, A.V., Prior, D.C., Belov, M.E., Smith, R.D.: Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures. J. Am. Soc. Mass Spectrom. 18, 1176–1187 (2007)
    • (2007) J. Am. Soc. Mass Spectrom. , vol.18 , pp. 1176-1187
    • Baker, E.S.1    Clowers, B.H.2    Li, F.M.3    Tang, K.4    Tolmachev, A.V.5    Prior, D.C.6    Belov, M.E.7    Smith, R.D.8
  • 35
    • 38849203178 scopus 로고    scopus 로고
    • Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry
    • COI: 1:CAS:528:DC%2BD1cXntVKq
    • Clowers, B.H., Ibrahim, Y.M., Prior, D.C., Danielson, W.F., Belov, M.E., Smith, R.D.: Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry. Anal. Chem. 80, 612–623 (2008)
    • (2008) Anal. Chem. , vol.80 , pp. 612-623
    • Clowers, B.H.1    Ibrahim, Y.M.2    Prior, D.C.3    Danielson, W.F.4    Belov, M.E.5    Smith, R.D.6
  • 36
    • 35448967517 scopus 로고    scopus 로고
    • Ion funnel trap interface for orthogonal time-of-flight mass spectrometry
    • COI: 1:CAS:528:DC%2BD2sXhtVantr7L
    • Ibrahim, Y., Belov, M.E., Tolmachev, A.V., Prior, D.C., Smith, R.D.: Ion funnel trap interface for orthogonal time-of-flight mass spectrometry. Anal. Chem. 79, 7845–7852 (2007)
    • (2007) Anal. Chem. , vol.79 , pp. 7845-7852
    • Ibrahim, Y.1    Belov, M.E.2    Tolmachev, A.V.3    Prior, D.C.4    Smith, R.D.5
  • 37
    • 49049091208 scopus 로고    scopus 로고
    • Automated gain control ion funnel trap for orthogonal time-offlight mass spectrometry
    • COI: 1:CAS:528:DC%2BD1cXmsF2hu7k%3D
    • Ibrahim, Y.M., Belov, M.E., Liyu, A.V., Smith, R.D.: Automated gain control ion funnel trap for orthogonal time-offlight mass spectrometry. Anal. Chem. 80, 5367–5376 (2008)
    • (2008) Anal. Chem. , vol.80 , pp. 5367-5376
    • Ibrahim, Y.M.1    Belov, M.E.2    Liyu, A.V.3    Smith, R.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.