메뉴 건너뛰기




Volumn 74, Issue 8, 2016, Pages 1608-1612

A Novel Method of Orbital Floor Reconstruction Using Virtual Planning, 3-Dimensional Printing, and Autologous Bone

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ARTICLE; BLOWOUT FRACTURE; BONE GRAFT; CASE REPORT; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; COST EFFECTIVENESS ANALYSIS; DIPLOPIA; ENOPHTHALMOS; EYE PAIN; EYE SWELLING; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGING SOFTWARE; IN VIVO STUDY; MATHEMATICAL ANALYSIS; MIDDLE AGED; ORBIT FRACTURE; ORBIT RECONSTRUCTION; ORBITAL FLOOR IMPLANT; SPLINE INTERPOLATION; SURGICAL TECHNIQUE; THREE DIMENSIONAL PRINTING; VIRTUAL PLANNING; AUTOTRANSPLANTATION; BONE TRANSPLANTATION; CYCLING; DIAGNOSTIC IMAGING; ILIAC BONE; INJURIES; ORBIT IMPLANT; ORBITAL FRACTURES; OSTEOSYNTHESIS; PROCEDURES; PROSTHESIS DESIGN; RECONSTRUCTIVE SURGERY; TRANSPLANTATION; X-RAY COMPUTED TOMOGRAPHY;

EID: 84967102070     PISSN: 02782391     EISSN: 15315053     Source Type: Journal    
DOI: 10.1016/j.joms.2016.03.044     Document Type: Article
Times cited : (38)

References (11)
  • 1
    • 33750234043 scopus 로고    scopus 로고
    • Reconstruction of internal orbital wall fracture with iliac crest free bone graft: Clinical, computed tomography, and magnetic resonance imaging follow-up study
    • 1 Kontio, R.K., Laine, P., Salo, A., et al. Reconstruction of internal orbital wall fracture with iliac crest free bone graft: Clinical, computed tomography, and magnetic resonance imaging follow-up study. Plast Reconstr Surg, 118, 2006, 6.
    • (2006) Plast Reconstr Surg , vol.118 , pp. 6
    • Kontio, R.K.1    Laine, P.2    Salo, A.3
  • 4
    • 84908250573 scopus 로고    scopus 로고
    • Verification of the usability of a navigation method in dental implant surgery: In vitro comparison with the stereolithographic surgical guide template method
    • 4 Kang, S.-H., Lee, J.-W., Lim, S.-H., et al. Verification of the usability of a navigation method in dental implant surgery: In vitro comparison with the stereolithographic surgical guide template method. J Craniomaxillofac Surg, 42, 2014, 7.
    • (2014) J Craniomaxillofac Surg , vol.42 , pp. 7
    • Kang, S.-H.1    Lee, J.-W.2    Lim, S.-H.3
  • 5
    • 84925248751 scopus 로고    scopus 로고
    • Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning
    • 5 Mazzoni, S., Bianchi, A., Schiariti, G., et al. Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning. J Oral Maxillofac Surg, 73, 2015, 4.
    • (2015) J Oral Maxillofac Surg , vol.73 , pp. 4
    • Mazzoni, S.1    Bianchi, A.2    Schiariti, G.3
  • 6
    • 84870179848 scopus 로고    scopus 로고
    • Materials used for reconstruction after orbital floor fracture
    • 6 Avashia, Y.J., Sastry, A., Fan, K.L., et al. Materials used for reconstruction after orbital floor fracture. J Craniofac Surg, 23(Suppl 1), 2012, 7.
    • (2012) J Craniofac Surg , vol.23 , pp. 7
    • Avashia, Y.J.1    Sastry, A.2    Fan, K.L.3
  • 7
    • 84919836293 scopus 로고    scopus 로고
    • Rapid prototyped patient specific implants for reconstruction of orbital wall defects
    • 7 Stoor, P., Suomalainen, A., Lindqvist, C., et al. Rapid prototyped patient specific implants for reconstruction of orbital wall defects. J Craniomaxillofac Surg, 42, 2014, 8.
    • (2014) J Craniomaxillofac Surg , vol.42 , pp. 8
    • Stoor, P.1    Suomalainen, A.2    Lindqvist, C.3
  • 8
    • 38049096133 scopus 로고    scopus 로고
    • Second generation (low modulus) titanium alloys in total hip arthroplasty
    • 8 Schuh, A., Bigoney, J., Hönle, W., et al. Second generation (low modulus) titanium alloys in total hip arthroplasty. Materwiss Werksttech, 38, 2007, 12.
    • (2007) Materwiss Werksttech , vol.38 , pp. 12
    • Schuh, A.1    Bigoney, J.2    Hönle, W.3
  • 9
    • 84992588683 scopus 로고    scopus 로고
    • Biomechanical properties of the human orbital floor for selection of reconstruction materials using a mathematical engineering model
    • [master's thesis] University of Groningen Groningen, The Netherlands Available at:
    • 9 Ong, H., Biomechanical properties of the human orbital floor for selection of reconstruction materials using a mathematical engineering model. [master's thesis], 2012, University of Groningen, Groningen, The Netherlands Available at: http://irs.ub.rug.nl/dbi/53f59f60d8234.
    • (2012)
    • Ong, H.1
  • 10
    • 84858138954 scopus 로고    scopus 로고
    • Orbital stress analysis, Part IV: Use of a “stiffness-graded” biodegradable implants to repair orbital blow-out fracture
    • 10 Al-Sukhun, J., Penttila, H., Ashammakhi, N., Orbital stress analysis, Part IV: Use of a “stiffness-graded” biodegradable implants to repair orbital blow-out fracture. J Craniofac Surg, 23, 2012, 1.
    • (2012) J Craniofac Surg , vol.23 , pp. 1
    • Al-Sukhun, J.1    Penttila, H.2    Ashammakhi, N.3
  • 11
    • 84989225403 scopus 로고    scopus 로고
    • The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing
    • 11 van Eijnatten, M., Rijkhorst, E.-J., Hofman, M., et al. The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing. Dentomaxillofac Radiol, 45, 2016, 5.
    • (2016) Dentomaxillofac Radiol , vol.45 , pp. 5
    • van Eijnatten, M.1    Rijkhorst, E.-J.2    Hofman, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.