Volumn 32, Issue 7, 2016, Pages 853-861

Production tolerance of additive manufactured polymeric objects for clinical applications

Author keywords

Accuracy; Additive manufacturing; Dentistry; Rapid prototyping; Selective laser sintering; Stereolithography

Indexed keywords

COMPUTER AIDED MANUFACTURING; DENTISTRY; LASER HEATING; MANUFACTURE; RAPID PROTOTYPING; REVERSE ENGINEERING; SINTERING; STEREOLITHOGRAPHY;

EID: 84964318826     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2016.03.020     Document Type: Article
Times cited : (95)

References (17)
  • 1
  • 2
    • 84355161961 scopus 로고    scopus 로고
    • The future of dental devices is digital
    • R. van Noort The future of dental devices is digital Dent Mater 28 2012 3 12 10.1016/j.dental.2011.10.014
    • (2012) Dent Mater , vol.28 , pp. 3-12
    • Van Noort, R.1
  • 4
    • 84949546633 scopus 로고    scopus 로고
    • Rapid prototyping technologies and their applications in prosthodontics, a review of literature
    • K. Torabi, E. Farjood, and S. Hamedani Rapid prototyping technologies and their applications in prosthodontics, a review of literature J Dent (Shiraz) 16 2015 1 9
    • (2015) J Dent (Shiraz) , vol.16 , pp. 1-9
    • Torabi, K.1    Farjood, E.2    Hamedani, S.3
  • 5
    • 77954978493 scopus 로고    scopus 로고
    • A method for performance evaluation of RE/RP systems in dentistry
    • M. Germani, R. Raffaeli, and A. Mazzoli A method for performance evaluation of RE/RP systems in dentistry Rapid Prototyp J 16 2010 345 355 10.1108/13552541011065740
    • (2010) Rapid Prototyp J , vol.16 , pp. 345-355
    • Germani, M.1    Raffaeli, R.2    Mazzoli, A.3
  • 6
    • 84884202561 scopus 로고    scopus 로고
    • Accuracy of medical models made by additive manufacturing (rapid manufacturing)
    • M. Salmi, K.-S. Paloheimo, J. Tuomi, J. Wolff, and A. Mäkitie Accuracy of medical models made by additive manufacturing (rapid manufacturing) J Cranio-Maxillofac Surg 1 2013 7 10.1016/j.jcms.2012.11.041
    • (2013) J Cranio-Maxillofac Surg , vol.1 , pp. 7
    • Salmi, M.1    Paloheimo, K.-S.2    Tuomi, J.3    Wolff, J.4    Mäkitie, A.5
  • 8
    • 0037103659 scopus 로고    scopus 로고
    • Analysis of the surface roughness and dimensional accuracy capability of fused deposition modelling processes
    • C.J.L. Pérez Analysis of the surface roughness and dimensional accuracy capability of fused deposition modelling processes Int J Prod Res 40 2002 2865 2881 10.1080/00207540210146099
    • (2002) Int J Prod Res , vol.40 , pp. 2865-2881
    • Pérez, C.J.L.1
  • 9
    • 74549117834 scopus 로고    scopus 로고
    • Error analysis of FDM fabricated medical replicas
    • I. Katatny El, S.H. Masood, and Y.S. Morsi Error analysis of FDM fabricated medical replicas Rapid Prototyp J 16 2010 36 43 10.1108/13552541011011695
    • (2010) Rapid Prototyp J , vol.16 , pp. 36-43
    • Katatny El, I.1    Masood, S.H.2    Morsi, Y.S.3
  • 11
    • 61549113133 scopus 로고    scopus 로고
    • Dimensional error of selective laser sintering, three-dimensional printing and PolyJet™ models in the reproduction of mandibular anatomy
    • D. Ibrahim, T.L. Broilo, C. Heitz, M.G. de Oliveira, H.W. de Oliveira, S.M.W. Nobre, and et al. Dimensional error of selective laser sintering, three-dimensional printing and PolyJet™ models in the reproduction of mandibular anatomy J Cranio-Maxillofac Surg 37 2009 167 173 10.1016/j.jcms.2008.10.008
    • (2009) J Cranio-Maxillofac Surg , vol.37 , pp. 167-173
    • Ibrahim, D.1    Broilo, T.L.2    Heitz, C.3    De Oliveira, M.G.4    De Oliveira, H.W.5    Nobre, S.M.W.6
  • 12
    • 54349093059 scopus 로고    scopus 로고
    • Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction
    • D.N. Silva, M.G. de Oliveira, E. Meurer, M.I. Meurer, J.V.L. da Silva, and A. Santa-Bárbara Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction J Cranio-Maxillofac Surg 36 2008 443 449 10.1016/j.jcms.2008.04.003
    • (2008) J Cranio-Maxillofac Surg , vol.36 , pp. 443-449
    • Silva, D.N.1    De Oliveira, M.G.2    Meurer, E.3    Meurer, M.I.4    Da Silva, J.V.L.5    Santa-Bárbara, A.6
  • 13
    • 84924037989 scopus 로고    scopus 로고
    • Sensitivity analysis of geometric errors in additive manufacturing medical models
    • J.M. Pinto, C. Arrieta, M.E. Andia, S. Uribe, J. Ramos-Grez, A. Vargas, and et al. Sensitivity analysis of geometric errors in additive manufacturing medical models Med Eng Phys 37 2015 328 334 10.1016/j.medengphy.2015.01.009
    • (2015) Med Eng Phys , vol.37 , pp. 328-334
    • Pinto, J.M.1    Arrieta, C.2    Andia, M.E.3    Uribe, S.4    Ramos-Grez, J.5    Vargas, A.6
  • 14
    • 0038488528 scopus 로고    scopus 로고
    • Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible
    • A. Örtorp, T. Jemt, T. Bäck, and T. Jälevik Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible Int J Prosthodont 16 2003 194 200
    • (2003) Int J Prosthodont , vol.16 , pp. 194-200
    • Örtorp, A.1    Jemt, T.2    Bäck, T.3    Jälevik, T.4
  • 15
    • 0031132089 scopus 로고    scopus 로고
    • Tolerance measurements of various implant components
    • T. Ma, J.I. Nicholls, and J.E. Rubenstein Tolerance measurements of various implant components JoMI 12 1997 371 375
    • (1997) JoMI , vol.12 , pp. 371-375
    • Ma, T.1    Nicholls, J.I.2    Rubenstein, J.E.3
  • 17
    • 0033162835 scopus 로고    scopus 로고
    • Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks
    • J.E. Rubenstein, and T. Ma Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks JoMI 14 1999 491 495
    • (1999) JoMI , vol.14 , pp. 491-495
    • Rubenstein, J.E.1    Ma, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.