1
-
-
0028318225
-
Accuracy of stereolithographic models of human anatomy
-
Barker, T.M., Earwaker, W.J.S., Lisle, D.A. Accuracy of stereolithographic models of human anatomy Australasian Radiology 38 2 1994 106-11
-
(1994)
Australasian Radiology
, vol.38
, Issue.2
, pp. 106-11
-
-
Barker, T.M.1
Earwaker, W.J.S.2
Lisle, D.A.3
-
2
-
-
0030756975
-
Stereolithographic models derived from X-ray computed tomography reproduction accuracy
-
Bouyssie, J.F., Bouyssie, S., Sharrock, P., Duran, D. Stereolithographic models derived from X-ray computed tomography reproduction accuracy Surgical and Radiologic Anatomy 19 3 1997 193-9
-
(1997)
Surgical and Radiologic Anatomy
, vol.19
, Issue.3
, pp. 193-9
-
-
Bouyssie, J.F.1
Bouyssie, S.2
Sharrock, P.3
Duran, D.4
-
3
-
-
0036005914
-
Analysis of errors in medical rapid prototyping models
-
Choi, J.Y., Choi, J.H., Kim, N.K., Kim, Y., Lee, J.K., Kim, M.K., Lee, J.H., Kim, M.J. Analysis of errors in medical rapid prototyping models International Journal of Oral and Maxillofacial Surgery 31 1 2002 23-32
-
(2002)
International Journal of Oral and Maxillofacial Surgery
, vol.31
, Issue.1
, pp. 23-32
-
-
Choi, J.Y.1
Choi, J.H.2
Kim, N.K.3
Kim, Y.4
Lee, J.K.5
Kim, M.K.6
Lee, J.H.7
Kim, M.J.8
-
4
-
-
74549199759
-
-
(adapted from: Buikstra and Ubelaker (1994) and Moore-Jansen et al. (1994), ANTH 6 - Forensic Anthropology)
-
Garwin, A. Measuring Adult Human Remains 2006 (adapted from: Buikstra and Ubelaker (1994) and Moore-Jansen et al. (1994), ANTH 6 - Forensic Anthropology)
-
(2006)
Measuring Adult Human Remains
-
-
Garwin, A.1
-
5
-
-
74549145414
-
-
Centro de Pesquisas Renato Archer Campinas available at: www.cenpra.gov.br/promed/software.htm
-
InVesalius InVesalius Software Centro de Pesquisas Renato Archer Campinas 2008 available at: www.cenpra.gov.br/promed/software.htm
-
(2008)
InVesalius Software
-
-
Invesalius1
-
6
-
-
0029966684
-
A comparison of three-dimensional computed tomography scans and stereolithographic models for evaluation of craniofacial anomalies
-
Kragskov, J., Sindet-Pedersen, S., Gyldensted, C., Jensen, K.L. A comparison of three-dimensional computed tomography scans and stereolithographic models for evaluation of craniofacial anomalies Journal of Oral and Maxillofacial Surgery 54 4 1996 402-12
-
(1996)
Journal of Oral and Maxillofacial Surgery
, vol.54
, Issue.4
, pp. 402-12
-
-
Kragskov, J.1
Sindet-Pedersen, S.2
Gyldensted, C.3
Jensen, K.L.4
-
7
-
-
0026653434
-
Reproducibility of three-dimensional CT-assisted model production in the maxillofacial area
-
Lill, W., Solar, P., Ulm, C., Watzek, G., Blahout, R., Matejka, M. Reproducibility of three-dimensional CT-assisted model production in the maxillofacial area British Journal of Oral and Maxillofacial Surgery 30 4 1992 233-6
-
(1992)
British Journal of Oral and Maxillofacial Surgery
, vol.30
, Issue.4
, pp. 233-6
-
-
Lill, W.1
Solar, P.2
Ulm, C.3
Watzek, G.4
Blahout, R.5
Matejka, M.6
-
8
-
-
74549150471
-
-
Materialise Leuven available at: www.materialise.com/magics
-
Materialise Magics v9.9 Materialise Leuven 2004 available at: www.materialise.com/magics
-
(2004)
Magics v9.9
-
-
Materialise1
-
9
-
-
3042686101
-
Fused deposition models from CT scans
-
Meakin, J.R., Shepherd, D.E.T., Hukins, D.W.L. Fused deposition models from CT scans British Journal of Radiology 77 918 2004 504-7
-
(2004)
British Journal of Radiology
, vol.77
, Issue.918
, pp. 504-7
-
-
Meakin, J.R.1
Shepherd, D.E.T.2
Hukins, D.W.L.3
-
10
-
-
55649104197
-
Dimensional accuracy of the skull models produced by rapid prototyping technology using stereolithography apparatus
-
Nizam, A., Gopal, R.N., Naing, L., Hakim, A.B., Samsudin, A.R. Dimensional accuracy of the skull models produced by rapid prototyping technology using stereolithography apparatus Orofacial Sciences 1 2006 60-6
-
(2006)
Orofacial Sciences
, vol.1
, pp. 60-6
-
-
Nizam, A.1
Gopal, R.N.2
Naing, L.3
Hakim, A.B.4
Samsudin, A.R.5
-
11
-
-
6544243874
-
Stereolithography versus milled three-dimensional models: Comparison of production method, indication, and accuracy
-
Santler, G., Karcher, H., Gaggl, A., Kern, R. Stereolithography versus milled three-dimensional models: comparison of production method, indication, and accuracy Computer Aided Surgery 3 5 1998 248-56
-
(1998)
Computer Aided Surgery
, vol.3
, Issue.5
, pp. 248-56
-
-
Santler, G.1
Karcher, H.2
Gaggl, A.3
Kern, R.4
-
12
-
-
0141831249
-
Accuracy of implant placement with a stereolithographic surgical guide
-
Sarment, D.P., Sukovic, P., Clinthorne, N. Accuracy of implant placement with a stereolithographic surgical guide International Journal of Oral and Maxillofacial Implants 18 4 2003 571-7
-
(2003)
International Journal of Oral and Maxillofacial Implants
, vol.18
, Issue.4
, pp. 571-7
-
-
Sarment, D.P.1
Sukovic, P.2
Clinthorne, N.3
-
13
-
-
74549207860
-
-
Stratasys Eden Prairie, MN available at: www.stratasys.com
-
Stratasys Insight, V3.1 Stratasys Eden Prairie, MN 2004 available at: www.stratasys.com
-
(2004)
Insight, V3.1
-
-
Stratasys1
|