-
2
-
-
0025217716
-
A new digital phased array system for dynamic focusing and steering with reduced sampling rate
-
T. K. Song and S. B. Park, "A new digital phased array system for dynamic focusing and steering with reduced sampling rate," Ultrason. Imaging, vol. 12, no. 1, pp. 1-16, 1990.
-
(1990)
Ultrason. Imaging
, vol.12
, Issue.1
, pp. 1-16
-
-
Song, T.K.1
Park, S.B.2
-
3
-
-
74949135915
-
CMOS ultrasound transceiver chip for high-resolution ultrasonic imaging systems
-
I. Kim, H. Kim, F. Griggio, R. L. Tutwiler, T. N. Jackson, S. T. McKinstry, K. Choi, "CMOS ultrasound transceiver chip for high-resolution ultrasonic imaging systems," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 5, pp. 293-303, 2009.
-
(2009)
IEEE Trans. Biomed. Circuits Syst.
, vol.3
, Issue.5
, pp. 293-303
-
-
Kim, I.1
Kim, H.2
Griggio, F.3
Tutwiler, R.L.4
Jackson, T.N.5
McKinstry, S.T.6
Choi, K.7
-
4
-
-
0025806883
-
Elastography: A squantitative method for imaging the elasticity of biological tissues
-
J. Ophir, I. Cespedes, H. Ponnekanti, Y. Yazdi, X. Li, "Elastography: a squantitative method for imaging the elasticity of biological tissues," Ultrason. Imaging, vol. 13, no. 2, pp. 111-134, 1991.
-
(1991)
Ultrason. Imaging
, vol.13
, Issue.2
, pp. 111-134
-
-
Ophir, J.1
Cespedes, I.2
Ponnekanti, H.3
Yazdi, Y.4
Li, X.5
-
5
-
-
79957796366
-
Volumetric flow measurement using an implantable CMUT array
-
M. Wang and J. Chen, "Volumetric flow measurement using an implantable CMUT array," IEEE Trans. Biomed. Circuits Syst., vol. 5, no. 3, pp. 214-222, 2011.
-
(2011)
IEEE Trans. Biomed. Circuits Syst.
, vol.5
, Issue.3
, pp. 214-222
-
-
Wang, M.1
Chen, J.2
-
6
-
-
0141527406
-
Adaptive clutter filtering for ultrasound color flow imaging
-
Y. Yoo, R. Managuli, Y. Kim, "Adaptive clutter filtering for ultrasound color flow imaging," Ultrasound Med. Biol., vol. 29, no. 9, pp. 1311-1320, 2003.
-
(2003)
Ultrasound Med. Biol.
, vol.29
, Issue.9
, pp. 1311-1320
-
-
Yoo, Y.1
Managuli, R.2
Kim, Y.3
-
7
-
-
79951960871
-
Point-of-Care ultrasonography
-
C. L. Moore and J. A. Copel, "Point-of-Care ultrasonography," New Eng. J. Med., vol. 364, no. 8, pp. 749-757, 2011.
-
(2011)
New Eng. J. Med.
, vol.364
, Issue.8
, pp. 749-757
-
-
Moore, C.L.1
Copel, J.A.2
-
8
-
-
0032282560
-
Portable ultrasound device for battlefield trauma
-
J.-J. Hwang, J. Quistgaard, J. Souquet, L. A. Crum, "Portable ultrasound device for battlefield trauma," in Proc. IEEE Ultrason. Symp., 1998.
-
(1998)
Proc IEEE Ultrason. Symp.
-
-
Hwang, J.-J.1
Quistgaard, J.2
Souquet, J.3
Crum, L.A.4
-
9
-
-
67649344813
-
A mobile medical device for point-of-care applications
-
S.-W. Yang, H.-C. Yoon, J. Cho, S.-B. Kye, T.-K. Song, "A mobile medical device for point-of-care applications," in Proc. IEEE Ultrason. Symp., 2008, pp. 1346-1349.
-
(2008)
Proc IEEE Ultrason. Symp.
, pp. 1346-1349
-
-
Yang, S.-W.1
Yoon, H.-C.2
Cho, J.3
Kye, S.-B.4
Song, T.-K.5
-
10
-
-
48149109759
-
Single-chip solution for ultrasound imaging systems: Initial results
-
A. Agarwal, T. Fukuoka, F. K. Schneider, Y. Yoo, F. Baluyot, Y. Kim, "Single-chip solution for ultrasound imaging systems: Initial results," in Proc. IEEE Ultrason. Symp., 2007, pp. 1563-1566.
-
(2007)
Proc IEEE Ultrason. Symp.
, pp. 1563-1566
-
-
Agarwal, A.1
Fukuoka, T.2
Schneider, F.K.3
Yoo, Y.4
Baluyot, F.5
Kim, Y.6
-
11
-
-
33745511584
-
New demodulation filter in digital phase rotation beamforming
-
F. K. Schneider, Y. Yoo, A. Agarwal, L. M. Koh, Y. Kim, "New demodulation filter in digital phase rotation beamforming," Ultrasonics, vol. 44, no. 3, pp. 265-271, 2006.
-
(2006)
Ultrasonics
, vol.44
, Issue.3
, pp. 265-271
-
-
Schneider, F.K.1
Yoo, Y.2
Agarwal, A.3
Koh, L.M.4
Kim, Y.5
-
12
-
-
34548099972
-
New demodulation method for efficient phase-rotation-based beamforming
-
A. Agarwal, Y. Yoo, F. K. Schneider, G. Changqing, K. L. Mong, K. Yongmin, "New demodulation method for efficient phase-rotation-based beamforming," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 54, no. 8, pp. 1656-1668, 2007.
-
(2007)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.54
, Issue.8
, pp. 1656-1668
-
-
Agarwal, A.1
Yoo, Y.2
Schneider, F.K.3
Changqing, G.4
Mong, K.L.5
Yongmin, K.6
-
13
-
-
77949669364
-
A fully programmable computing architecture for medical ultrasound machines
-
F. K. Schneider, A. Agarwal, Y. M. Yoo, T. Fukuoka, Y. Kim, "A fully programmable computing architecture for medical ultrasound machines," IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 2, pp. 538-540, 2010.
-
(2010)
IEEE Trans. Inf. Technol. Biomed.
, vol.14
, Issue.2
, pp. 538-540
-
-
Schneider, F.K.1
Agarwal, A.2
Yoo, Y.M.3
Fukuoka, T.4
Kim, Y.5
-
14
-
-
84865213587
-
A single FPGA-based portable ultrasound imaging system for point-of-care applications
-
G. D. Kim, C. Yoon, S. B. Kye, Y. Lee, J. Kang, Y. Yoo, T.-K. Song, "A single FPGA-based portable ultrasound imaging system for point-of-care applications," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 59, no. 7, pp. 1386-1394, 2012.
-
(2012)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.59
, Issue.7
, pp. 1386-1394
-
-
Kim, G.D.1
Yoon, C.2
Kye, S.B.3
Lee, Y.4
Kang, J.5
Yoo, Y.6
Song, T.-K.7
-
15
-
-
34250202556
-
A fractional filter-based beamformer architecture using postfiltering approach to minimize hardware complexity
-
J. Cho, J.-Y. Lee, J.-H. Song, Y. Kim, T.-K. Song, "A fractional filter-based beamformer architecture using postfiltering approach to minimize hardware complexity," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 54, no. 5, pp. 1076-1079, 2007.
-
(2007)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.54
, Issue.5
, pp. 1076-1079
-
-
Cho, J.1
Lee, J.-Y.2
Song, J.-H.3
Kim, Y.4
Song, T.-K.5
-
16
-
-
0021445103
-
A comparison of efficient beamforming algorithms
-
R. Mucci, "A comparison of efficient beamforming algorithms," IEEE Trans. Acoust., Speech, Signal Process, vol. 32, no. 3, pp. 548-558, 1984.
-
(1984)
IEEE Trans. Acoust., Speech, Signal Process
, vol.32
, Issue.3
, pp. 548-558
-
-
Mucci, R.1
-
17
-
-
0014891050
-
Sampling and interpolation of bandlimited signals by quadrature methods
-
O. D. Grace and S. P. Pitt, "Sampling and interpolation of bandlimited signals by quadrature methods," J. Acoust. Soc. Amer., vol. 48, pp. 1311-1318, 1970.
-
(1970)
J. Acoust. Soc. Amer.
, vol.48
, pp. 1311-1318
-
-
Grace, O.D.1
Pitt, S.P.2
-
18
-
-
0026945778
-
Digital beamforming in ultrasound
-
B. D. Steinberg, "Digital beamforming in ultrasound," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 39, no. 6, pp. 716-721, 1992.
-
(1992)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.39
, Issue.6
, pp. 716-721
-
-
Steinberg, B.D.1
-
19
-
-
78751668742
-
Time-sharing bilinear delay interpolation for ultrasound dynamic receive beamformer
-
H.-Y. Sohn, J. Kang, J. Cho, T.-K. Song, Y. Yoo, "Time-sharing bilinear delay interpolation for ultrasound dynamic receive beamformer," Electron Lett., vol. 47, no. 2, pp. 89-91, 2011.
-
(2011)
Electron Lett.
, vol.47
, Issue.2
, pp. 89-91
-
-
Sohn, H.-Y.1
Kang, J.2
Cho, J.3
Song, T.-K.4
Yoo, Y.5
-
21
-
-
79957949874
-
The new efficient multi-beamforming method based on multi-access register block on a post-fractional filtering architecture
-
Mar. 26
-
J. Kang, G.-D. Kim, C. Yoon, Y. Yoo, T.-K. Song, "The new efficient multi-beamforming method based on multi-access register block on a post-fractional filtering architecture," Proc. SPIE, vol. 7968, Mar. 26, 2011, 796815.
-
(2011)
Proc. SPIE
, vol.7968
, pp. 796815
-
-
Kang, J.1
Kim, G.-D.2
Yoon, C.3
Yoo, Y.4
Song, T.-K.5
-
23
-
-
68249161931
-
Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imaging
-
J. H. Chang, L. Sun, J. T. Yen, K. K. Shung, "Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imaging," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 56, no. 7, pp. 1490-1497, 2009.
-
(2009)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.56
, Issue.7
, pp. 1490-1497
-
-
Chang, J.H.1
Sun, L.2
Yen, J.T.3
Shung, K.K.4
-
25
-
-
84884798252
-
An efficient pulse compression method of chirp-coded excitation in medical ultrasound imaging
-
C. Yoon, W. Lee, J. H. Chang, T.-K. Song, Y. Yoo, "An efficient pulse compression method of chirp-coded excitation in medical ultrasound imaging," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 60, no. 10, pp. 2225-2229, 2013.
-
(2013)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.60
, Issue.10
, pp. 2225-2229
-
-
Yoon, C.1
Lee, W.2
Chang, J.H.3
Song, T.-K.4
Yoo, Y.5
-
26
-
-
29144534581
-
Cross-correlation of long binary signals with longer mismatched filters
-
N. Levanon, "Cross-correlation of long binary signals with longer mismatched filters," IEEE Proc.-Radar Sonar Nav., vol. 152, pp. 377-382, 2005.
-
(2005)
IEEE Proc.-Radar Sonar Nav.
, vol.152
, pp. 377-382
-
-
Levanon, N.1
-
27
-
-
84861097158
-
Adaptive dynamic quadrature demodulation with autoregressive spectral estimation in ultrasound imaging
-
D.-Y. Lee, Y. Yoo, T.-K. Song, J. H. Chang, "Adaptive dynamic quadrature demodulation with autoregressive spectral estimation in ultrasound imaging," Biomed. Signal Process. Control, vol. 7, no. 4, pp. 371-378, 2011.
-
(2011)
Biomed. Signal Process. Control
, vol.7
, Issue.4
, pp. 371-378
-
-
Lee, D.-Y.1
Yoo, Y.2
Song, T.-K.3
Chang, J.H.4
-
28
-
-
76049096503
-
Frequency compounded imaging with a high-frequency dual element transducer
-
J. H. Chang, H. H. Kim, J. Lee, K. K. Shung, "Frequency compounded imaging with a high-frequency dual element transducer," Ultrasonics, vol. 50, pp. 453-457, 2010.
-
(2010)
Ultrasonics
, vol.50
, pp. 453-457
-
-
Chang, J.H.1
Kim, H.H.2
Lee, J.3
Shung, K.K.4
-
29
-
-
84869038138
-
Adaptive frequency compounding for speckle reduction
-
I. Song, C. Yoon, G. Kim, Y. Yoo, J. Chang, "Adaptive frequency compounding for speckle reduction," in Proc. IEEE Ultrason. Symp., 2011, pp. 1435-1438.
-
(2011)
Proc IEEE Ultrason. Symp.
, pp. 1435-1438
-
-
Song, I.1
Yoon, C.2
Kim, G.3
Yoo, Y.4
Chang, J.5
-
30
-
-
43849101988
-
Space variant ultrasound frequency compounding based on noise characteristics
-
Y. Erez, Y. Y. Schechner, D. Adam, "Space variant ultrasound frequency compounding based on noise characteristics," Ultrasound Med. Biol., vol. 34, no. 6, pp. 981-1000, 2008.
-
(2008)
Ultrasound Med. Biol.
, vol.34
, Issue.6
, pp. 981-1000
-
-
Erez, Y.1
Schechner, Y.Y.2
Adam, D.3
-
31
-
-
47549118891
-
Adaptive clutter rejection for 3D color Doppler imaging: Preliminary clinical study
-
Y. Yoo, S. Sikdar, K. Karadayi, O. Kolokythas, Y. Kim, "Adaptive clutter rejection for 3D color Doppler imaging: preliminary clinical study," Ultrasound Med. Biol., vol. 34, no. 8, pp. 1221-1231, 2008.
-
(2008)
Ultrasound Med. Biol.
, vol.34
, Issue.8
, pp. 1221-1231
-
-
Yoo, Y.1
Sikdar, S.2
Karadayi, K.3
Kolokythas, O.4
Kim, Y.5
-
32
-
-
0036482792
-
Clutter filter design for ultrasound color flow imaging
-
S. Bjærum, H. Torp, K. Kristoffersen, "Clutter filter design for ultrasound color flow imaging," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 49, no. 2, pp. 204-216, 2002.
-
(2002)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.49
, Issue.2
, pp. 204-216
-
-
Bjærum, S.1
Torp, H.2
Kristoffersen, K.3
-
33
-
-
0032118627
-
Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming
-
G. R. Lockwood, J. R. Talman, S. S. Brunke, "Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 45, no. 4, pp. 980-988, 1998.
-
(1998)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.45
, Issue.4
, pp. 980-988
-
-
Lockwood, G.R.1
Talman, J.R.2
Brunke, S.S.3
-
35
-
-
77949491457
-
Coded excitation for ultrasound tissue harmonic imaging
-
J. Song, S. Kim, H. Y. Sohn, T. K. Song, Y. Yoo, "Coded excitation for ultrasound tissue harmonic imaging," Ultrasonics, vol. 50, no. 6, pp. 613-619, 2010.
-
(2010)
Ultrasonics
, vol.50
, Issue.6
, pp. 613-619
-
-
Song, J.1
Kim, S.2
Sohn, H.Y.3
Song, T.K.4
Yoo, Y.5
-
36
-
-
84887322148
-
Ultrasonic imaging transceiver design for CMUT: A three-level pulse-shaping pulser with improved efficiency and a noise-optimized receiver
-
K. Chen, H. S. Lee, A. P. Chandrakasan, C. G. Sodini, "Ultrasonic imaging transceiver design for CMUT: a three-level pulse-shaping pulser with improved efficiency and a noise-optimized receiver," IEEE J. Solid-State Circuits, vol. 48, no. 11, pp. 2734-2745, 2013.
-
(2013)
IEEE J. Solid-State Circuits
, vol.48
, Issue.11
, pp. 2734-2745
-
-
Chen, K.1
Lee, H.S.2
Chandrakasan, A.P.3
Sodini, C.G.4
-
37
-
-
65349145884
-
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
-
G. Montaldo, M. Tanter, J. Bercoff, N. Benech, M. Fink, "Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 56, no. 3, pp. 489-506, 2009.
-
(2009)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.56
, Issue.3
, pp. 489-506
-
-
Montaldo, G.1
Tanter, M.2
Bercoff, J.3
Benech, N.4
Fink, M.5
-
38
-
-
78751662185
-
Ultrafast compounding Doppler imaging: Providing full blood flow characterization
-
J. Bercoff, G. Montaldo, T. Loupas, D. Savery, F. Meziere, M. Fink, "Ultrafast compounding Doppler imaging: providing full blood flow characterization," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 58, no. 1, pp. 134-147, 2011.
-
(2011)
IEEE Trans. Ultrason., Ferroelectr., Freq. Control
, vol.58
, Issue.1
, pp. 134-147
-
-
Bercoff, J.1
Montaldo, G.2
Loupas, T.3
Savery, D.4
Meziere, F.5
Fink, M.6
-
39
-
-
84893853399
-
Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays
-
Dec.
-
A. Bhuyan, J. W. Choe, B. C. Lee, I. O. Wygant, A. Nikoozadeh, Ö. Oralkan, B. T. Khuri-Yakub, "Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays," IEEE Trans. Biomed. Circuits Syst., vol. 7, no. 6, pp. 796-804, Dec. 2013.
-
(2013)
IEEE Trans. Biomed. Circuits Syst.
, vol.7
, Issue.6
, pp. 796-804
-
-
Bhuyan, A.1
Choe, J.W.2
Lee, B.C.3
Wygant, I.O.4
Nikoozadeh, A.5
Oralkan, O.6
Khuri-Yakub, B.T.7
-
40
-
-
84882326255
-
Hybrid volume beamforming for 3-D ultrasound imaging using 2-D CMUT arrays
-
B. H. Kim, T. K. Song, Y. Yoo, J. H. Chang, S. Lee, Y. Kim, K. Cho, J. Song, "Hybrid volume beamforming for 3-D ultrasound imaging using 2-D CMUT arrays," in Proc. IEEE Ultrason. Symp., 2012, pp. 2246-2249.
-
(2012)
Proc IEEE Ultrason. Symp.
, pp. 2246-2249
-
-
Kim, B.H.1
Song, T.K.2
Yoo, Y.3
Chang, J.H.4
Lee, S.5
Kim, Y.6
Cho, K.7
Song, J.8
-
41
-
-
84910089674
-
A column-row-parallel ultrasound imaging architecture for 3D plane-wave imaging and Tx 2nd-order harmonic distortion (HD2) reduction
-
K. Chen, B. C. Lee, K. Thomenius, B. T. Khuri-Yakub, H. S. Lee, C. G. Sodini, "A column-row-parallel ultrasound imaging architecture for 3D plane-wave imaging and Tx 2nd-order harmonic distortion (HD2) reduction," in Proc. IEEE Ultrason. Symp., 2014, pp. 317-320.
-
(2014)
Proc IEEE Ultrason. Symp.
, pp. 317-320
-
-
Chen, K.1
Lee, B.C.2
Thomenius, K.3
Khuri-Yakub, B.T.4
Lee, H.S.5
Sodini, C.G.6
|