메뉴 건너뛰기




Volumn , Issue , 2014, Pages 317-320

A column-row-parallel ultrasound imaging architecture for 3d plane-wave imaging and Tx 2nd-order harmonic distortion (HD2) reduction

Author keywords

[No Author keywords available]

Indexed keywords

ARCHITECTURE; ELASTIC WAVES; FAULT TOLERANCE; HARMONIC ANALYSIS; HARMONIC DISTORTION; IMAGING SYSTEMS; MEDICAL IMAGING; ULTRASONIC IMAGING; WAVE PROPAGATION;

EID: 84910089674     PISSN: 19485719     EISSN: 19485727     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2014.0078     Document Type: Conference Paper
Times cited : (11)

References (15)
  • 1
    • 84910038352 scopus 로고
    • High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
    • S. Smith et al., "High-speed ultrasound volumetric imaging system. i. transducer design and beam steering," IEEE UFFC, 1991.
    • (1991) IEEE UFFC
    • Smith, S.1
  • 2
    • 67649537421 scopus 로고    scopus 로고
    • Minimally redundant 2-d array designs for 3-d medical ultrasound imaging
    • M. Karaman et al., "Minimally redundant 2-d array designs for 3-d medical ultrasound imaging," Medical Imaging, IEEE Trans. on, 2009.
    • (2009) Medical Imaging, IEEE Trans. on
    • Karaman, M.1
  • 3
    • 4143053716 scopus 로고    scopus 로고
    • Fully sampled matrix transducer for real time 3d ultrasonic imaging
    • B. Savord and R. Solomon, "Fully sampled matrix transducer for real time 3d ultrasonic imaging," in IEEE Ultrasonics Symposium, 2003.
    • (2003) IEEE Ultrasonics Symposium
    • Savord, B.1    Solomon, R.2
  • 4
    • 84910079763 scopus 로고    scopus 로고
    • Hybrid volume beamforming for 3-d ultrasound imaging using 2-d cmut arrays
    • B.-H. Kim et al., "Hybrid volume beamforming for 3-d ultrasound imaging using 2-d cmut arrays," in IEEE Ultrasonics Symposium, 2012.
    • (2012) IEEE Ultrasonics Symposium
    • Kim, B.-H.1
  • 5
    • 84910038350 scopus 로고    scopus 로고
    • A 256 x 256 2-d array transducer with rowcolumn addressing for 3-d rectilinear imaging
    • C. H. Seo and J. Yen, "A 256 x 256 2-d array transducer with rowcolumn addressing for 3-d rectilinear imaging," IEEE UFFC, 2009.
    • (2009) IEEE UFFC
    • Seo, C.H.1    Yen, J.2
  • 6
    • 84910079762 scopus 로고    scopus 로고
    • 3-d ultrasound imaging performance of a rowcolumn addressed 2-d array transducer: A measurement study
    • M. Rasmussen et al., "3-d ultrasound imaging performance of a rowcolumn addressed 2-d array transducer: A measurement study," IUS'13.
    • IUS'13
    • Rasmussen, M.1
  • 7
    • 48149087235 scopus 로고    scopus 로고
    • Crisscross 2d cmut array: Beamforming strategy and synthetic 3d imaging results
    • A. Savoia et al., "Crisscross 2d cmut array: Beamforming strategy and synthetic 3d imaging results," in IEEE Ultrasonics Symposium, 2007.
    • (2007) IEEE Ultrasonics Symposium
    • Savoia, A.1
  • 8
    • 84905652754 scopus 로고    scopus 로고
    • A column-row-parallel asic architecture for 3d wearable / portable medical ultrasonic imaging
    • K. Chen, H.-S. Lee, and C. Sodini, "A column-row-parallel asic architecture for 3d wearable / portable medical ultrasonic imaging," in IEEE VLSI Symposia, 2014.
    • (2014) IEEE VLSI Symposia
    • Chen, K.1    Lee, H.-S.2    Sodini, C.3
  • 9
    • 84887322148 scopus 로고    scopus 로고
    • Ultrasonic imaging transceiver design for cmut: A three-level 30-vpp pulse-shaping pulser with improved efficiency and a noise-optimized receiver
    • K. Chen, H.-S. Lee, A. Chandrakasan, and C. Sodini, "Ultrasonic imaging transceiver design for cmut: A three-level 30-vpp pulse-shaping pulser with improved efficiency and a noise-optimized receiver," Solid-State Circuits, IEEE Journal of, vol. 48, no. 11, pp. 2734-2745, 2013.
    • (2013) Solid-State Circuits, IEEE Journal of , vol.48 , Issue.11 , pp. 2734-2745
    • Chen, K.1    Lee, H.-S.2    Chandrakasan, A.3    Sodini, C.4
  • 11
    • 84910038348 scopus 로고    scopus 로고
    • Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
    • G. Montaldo et al., "Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography," IEEE UFFC, 09.
    • IEEE UFFC, 09
    • Montaldo, G.1
  • 12
    • 84910079760 scopus 로고    scopus 로고
    • Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization
    • S. Satir et al., "Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization," IEEE UFFC, 2012.
    • (2012) IEEE UFFC
    • Satir, S.1
  • 13
    • 84906337384 scopus 로고    scopus 로고
    • Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array
    • A. Novell et al., "Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array," Physics in medicine and biology, 2014.
    • (2014) Physics in Medicine and Biology
    • Novell, A.1
  • 14
    • 79956151016 scopus 로고    scopus 로고
    • Second harmonic inversion for ultrasound contrast harmonic imaging
    • M. Pasovic et al., "Second harmonic inversion for ultrasound contrast harmonic imaging," Physics in Medicine and Biology, 2011.
    • (2011) Physics in Medicine and Biology
    • Pasovic, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.