메뉴 건너뛰기




Volumn 279, Issue 1, 2016, Pages 185-194

Quantitative features of liver lesions, lung nodules, and renal stones at multi-detector row CT examinations: Dependency on radiation dose and reconstruction algorithm

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ANALYSIS; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; IMAGING SOFTWARE; LIVER INJURY; LUNG NODULE; MALE; MULTICENTER STUDY (TOPIC); MULTIDETECTOR COMPUTED TOMOGRAPHY; NEPHROLITHIASIS; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUANTITATIVE ANALYSIS; RADIATION DOSE; RETROSPECTIVE STUDY; STONE ANALYSIS; TUMOR VOLUME; ALGORITHM; CLINICAL TRIAL; COMPUTER ASSISTED DIAGNOSIS; LIVER DISEASE; LUNG DISEASE; MIDDLE AGED; MULTICENTER STUDY; RADIOGRAPHY; VERY ELDERLY;

EID: 84962881129     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2015150892     Document Type: Article
Times cited : (95)

References (22)
  • 4
    • 57849117384 scopus 로고    scopus 로고
    • New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
    • Eisenhauer EA, Therasse P, Bogaerts J, et al. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). Eur J Cancer 2009;45(2):228-247.
    • (2009) Eur J Cancer , vol.45 , Issue.2 , pp. 228-247
    • Eisenhauer, E.A.1    Therasse, P.2    Bogaerts, J.3
  • 5
    • 84919461263 scopus 로고    scopus 로고
    • Comparison of the quantitative CT imaging bio-markers of idiopathic pulmonary fbrosis at baseline and early change with an interval of 7 months
    • Kim HJ, Brown MS, Chong D, et al. Comparison of the quantitative CT imaging bio-markers of idiopathic pulmonary fbrosis at baseline and early change with an interval of 7 months. Acad Radiol 2015;22(1):70-80.
    • (2015) Acad Radiol , vol.22 , Issue.1 , pp. 70-80
    • Kim, H.J.1    Brown, M.S.2    Chong, D.3
  • 6
    • 56449104997 scopus 로고    scopus 로고
    • Imaging as a tumor biomarker in oncology drug trials for lung cancer: The FDA perspective
    • Petrick N, Brown DG, Suleiman O, Myers KJ. Imaging as a tumor biomarker in oncology drug trials for lung cancer: the FDA perspective. Clin Pharmacol Ther 2008; 84(4):523-525.
    • (2008) Clin Pharmacol Ther , vol.84 , Issue.4 , pp. 523-525
    • Petrick, N.1    Brown, D.G.2    Suleiman, O.3    Myers, K.J.4
  • 7
    • 84890089763 scopus 로고    scopus 로고
    • Locally advanced squamous cell carcinoma of the head and neck: CT texture and histogram analysis allow independent prediction of overall survival in patients treated with induction chemotherapy
    • Zhang H, Graham CM, Elci O, et al. Locally advanced squamous cell carcinoma of the head and neck: CT texture and histogram analysis allow independent prediction of overall survival in patients treated with induction chemotherapy. Radiology 2013;269 (3):801-809.
    • (2013) Radiology , vol.269 , Issue.3 , pp. 801-809
    • Zhang, H.1    Graham, C.M.2    Elci, O.3
  • 8
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007;34(11):4526-4544.
    • (2007) Med Phys , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 9
    • 84920141704 scopus 로고    scopus 로고
    • Diagnostic performance of an advanced modeled iterative reconstruction algorithm for low-contrast detectability with a third-generation dual-source multidetec-tor CT scanner: Potential for radiation dose reduction in a multireader study
    • Solomon J, Mileto A, Ramirez Giraldo JC, Samei E. Diagnostic performance of an advanced modeled iterative reconstruction algorithm for low-contrast detectability with a third-generation dual-source multidetec-tor CT scanner: potential for radiation dose reduction in a multireader study. Radiology 2015;275(3):735-745.
    • (2015) Radiology , vol.275 , Issue.3 , pp. 735-745
    • Solomon, J.1    Mileto, A.2    Ramirez Giraldo, J.C.3    Samei, E.4
  • 10
    • 84870903463 scopus 로고    scopus 로고
    • Abdominal CT with model-based iterative reconstruction (MBIR): Initial results of a prospective trial comparing ultralow-dose with standard-dose imaging
    • Pickhardt PJ, Lubner MG, Kim DH, et al. Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. AJR Am J Roentgenol 2012;199(6):1266-1274.
    • (2012) AJR Am J Roentgenol , vol.199 , Issue.6 , pp. 1266-1274
    • Pickhardt, P.J.1    Lubner, M.G.2    Kim, D.H.3
  • 11
    • 84919340238 scopus 로고    scopus 로고
    • Evaluating iterative reconstruction performance in computed tomography
    • Chen B, Ramirez Giraldo JC, Solomon J, Samei E. Evaluating iterative reconstruction performance in computed tomography. Med Phys 2014;41(12):121913.
    • (2014) Med Phys , vol.41 , Issue.12 , pp. 121913
    • Chen, B.1    Ramirez Giraldo, J.C.2    Solomon, J.3    Samei, E.4
  • 12
    • 84858293727 scopus 로고    scopus 로고
    • Iterative reconstruction methods in X-ray CT
    • Beister M, Kolditz D, Kalender WA. Iterative reconstruction methods in X-ray CT. Phys Med 2012;28(2):94-108.
    • (2012) Phys Med , vol.28 , Issue.2 , pp. 94-108
    • Beister, M.1    Kolditz, D.2    Kalender, W.A.3
  • 13
    • 84878499351 scopus 로고    scopus 로고
    • Performance of iterative image reconstruction in CT of the paranasal sinuses: A phantom study
    • Schulz B, Beeres M, Bodelle B, et al. Performance of iterative image reconstruction in CT of the paranasal sinuses: a phantom study. AJNR Am J Neuroradiol 2013;34(5): 1072-1076.
    • (2013) AJNR Am J Neuroradiol , vol.34 , Issue.5 , pp. 1072-1076
    • Schulz, B.1    Beeres, M.2    Bodelle, B.3
  • 14
    • 84920761559 scopus 로고    scopus 로고
    • Task-based measures of image quality and their relation to radiation dose and patient risk
    • Barrett HH, Myers KJ, Hoeschen C, Ku-pinski MA, Little MP. Task-based measures of image quality and their relation to radiation dose and patient risk. Phys Med Biol 2015;60(2):R1-R75.
    • (2015) Phys Med Biol , vol.60 , Issue.2 , pp. R1-R75
    • Barrett, H.H.1    Myers, K.J.2    Hoeschen, C.3    Ku-Pinski, M.A.4    Little, M.P.5
  • 15
    • 84879284577 scopus 로고    scopus 로고
    • Precision of iodine quan-tifcation in hepatic CT: Effects of iterative reconstruction with various imaging parameters
    • Chen B, Marin D, Richard S, Husarik D, Nelson R, Samei E. Precision of iodine quan-tifcation in hepatic CT: effects of iterative reconstruction with various imaging parameters. AJR Am J Roentgenol 2013;200(5): W475-W482.
    • (2013) AJR Am J Roentgenol , vol.200 , Issue.5 , pp. W475-W482
    • Chen, B.1    Marin, D.2    Richard, S.3    Husarik, D.4    Nelson, R.5    Samei, E.6
  • 16
    • 84902437339 scopus 로고    scopus 로고
    • Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods
    • Chen B, Christianson O, Wilson JM, Samei E. Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods. Med Phys 2014;41(7):071909.
    • (2014) Med Phys , vol.41 , Issue.7 , pp. 071909
    • Chen, B.1    Christianson, O.2    Wilson, J.M.3    Samei, E.4
  • 17
    • 84889633438 scopus 로고    scopus 로고
    • Volumetric quantifca-tion of lung nodules in CT with iterative reconstruction (ASiR and MBIR)
    • Chen B, Barnhart H, Richard S, Robins M, Colsher J, Samei E. Volumetric quantifca-tion of lung nodules in CT with iterative reconstruction (ASiR and MBIR). Med Phys 2013;40(11):111902.
    • (2013) Med Phys , vol.40 , Issue.11 , pp. 111902
    • Chen, B.1    Barnhart, H.2    Richard, S.3    Robins, M.4    Colsher, J.5    Samei, E.6
  • 18
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 2009;193(3):764-771.
    • (2009) AJR Am J Roentgenol , vol.193 , Issue.3 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3    Kujak, J.L.4    Lawder, H.J.5    Pavlicek, W.6
  • 19
    • 84871759658 scopus 로고    scopus 로고
    • Iterative reconstruction methods in two different MDCT scanners: Physical metrics and 4-Alternative forced-choice detectability experiments-A phantom approach
    • Miéville FA, Gudinchet F, Brunelle F, Bochud FO, Verdun FR. Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments-a phantom approach. Phys Med 2013;29(1):99-110.
    • (2013) Phys Med , vol.29 , Issue.1 , pp. 99-110
    • Miéville, F.A.1    Gudinchet, F.2    Brunelle, F.3    Bochud, F.O.4    Verdun, F.R.5
  • 20
    • 54049152738 scopus 로고    scopus 로고
    • Medical image analysis of 3D CT images based on extension of Haralick texture features
    • Tesar L, Shimizu A, Smutek D, Kobatake H, Nawano S. Medical image analysis of 3D CT images based on extension of Haralick texture features. Comput Med Imaging Graph 2008;32(6):513-520.
    • (2008) Comput Med Imaging Graph , vol.32 , Issue.6 , pp. 513-520
    • Tesar, L.1    Shimizu, A.2    Smutek, D.3    Kobatake, H.4    Nawano, S.5
  • 22
    • 84908079635 scopus 로고    scopus 로고
    • A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging
    • Solomon J, Samei E. A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging. Phys Med Biol 2014;59(21):6637-6657.
    • (2014) Phys Med Biol , vol.59 , Issue.21 , pp. 6637-6657
    • Solomon, J.1    Samei, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.