Volumn 63, Issue 2, 2016, Pages 336-351

Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound

Author keywords

Backscatter coefficients; envelope statistics; quantitative ultrasound; tissue characterization

Indexed keywords

BACKSCATTERING; BIOPSY; CLASSIFICATION (OF INFORMATION); DIAGNOSIS; DISEASE CONTROL; DISEASES; IMAGING TECHNIQUES; PARAMETERIZATION; SHEAR FLOW; SHEAR WAVES; STATISTICS; TISSUE; ULTRASONIC APPLICATIONS;

EID: 84962030620     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2015.2513958     Document Type: Review
Times cited : (290)

References (167)
  • 1
    • 0029182394 scopus 로고
    • The first clinical X-ray made in America-100 years
    • P. K. Spiegel, "The first clinical X-ray made in America-100 years," Amer. J. Roentgenol., vol. 164, pp. 241-243, 1995.
    • (1995) Amer. J. Roentgenol. , vol.164 , pp. 241-243
    • Spiegel, P.K.1
  • 3
    • 77952050391 scopus 로고    scopus 로고
    • Solving the overdiagnosis dilemma
    • L. Esserman and I. Thompson, "Solving the overdiagnosis dilemma," J. Nat. Cancer Inst., vol. 102, pp. 582-583, 2010.
    • (2010) J. Nat. Cancer Inst. , vol.102 , pp. 582-583
    • Esserman, L.1    Thompson, I.2
  • 4
    • 70349419536 scopus 로고    scopus 로고
    • Image-detected breast cancer: State-of-the-art diagnosis and treatment
    • M. Silverstein et al., "Image-detected breast cancer: State-of-the-art diagnosis and treatment," J. Amer. Coll. Surg., vol. 209, pp. 504-520, 2009.
    • (2009) J. Amer. Coll. Surg. , vol.209 , pp. 504-520
    • Silverstein, M.1
  • 5
    • 84882295434 scopus 로고    scopus 로고
    • Quantitative ultrasound techniques and improvements to diagnostic ultrasonic imaging
    • M. L. Oelze, "Quantitative ultrasound techniques and improvements to diagnostic ultrasonic imaging," in Proc IEEE Ultrason. Symp., Dresden, Germany, pp. 232-239, 2012.
    • (2012) Proc. IEEE Ultrason. Symp., Dresden, Germany , pp. 232-239
    • Oelze, M.L.1
  • 9
    • 0020736522 scopus 로고
    • Theoretical framework for spectrum analysis in ultrasonic tissue characterization
    • F. L. Lizzi, M. Greenebaum, E. J. Feleppa, and M. Elbaum, "Theoretical framework for spectrum analysis in ultrasonic tissue characterization," J. Acoust. Soc. Amer., vol. 73, pp. 1366-1373, 1983.
    • (1983) J. Acoust. Soc. Amer. , vol.73 , pp. 1366-1373
    • Lizzi, F.L.1    Greenebaum, M.2    Feleppa, E.J.3    Elbaum, M.4
  • 10
    • 0025343519 scopus 로고
    • Describing small-scale structure in random media using pulse-echo ultrasound
    • M. F. Insana, R. F. Wagner, D. G. Brown, and T. J. Hall, "Describing small-scale structure in random media using pulse-echo ultrasound," J. Acoust. Soc. Amer., vol. 87, pp. 179-192, 1990.
    • (1990) J. Acoust. Soc. Amer. , vol.87 , pp. 179-192
    • Insana, M.F.1    Wagner, R.F.2    Brown, D.G.3    Hall, T.J.4
  • 11
    • 79959587248 scopus 로고    scopus 로고
    • On the estimation of backscatter coefficients using single-element focused transducers
    • R. J. Lavarello, G. Ghoshal, and M. L. Oelze, "On the estimation of backscatter coefficients using single-element focused transducers," J. Acoust. Soc. Amer., vol. 129, pp. 2903-2911, 2011.
    • (2011) J. Acoust. Soc. Amer. , vol.129 , pp. 2903-2911
    • Lavarello, R.J.1    Ghoshal, G.2    Oelze, M.L.3
  • 12
    • 0025230571 scopus 로고
    • Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors
    • L. X. Yao, J. A. Zagzebski, and E. L. Madsen, "Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors," Ultrason. Imaging, vol. 12, pp. 58-70, 1990.
    • (1990) Ultrason. Imaging , vol.12 , pp. 58-70
    • Yao, L.X.1    Zagzebski, J.A.2    Madsen, E.L.3
  • 13
    • 0031195059 scopus 로고    scopus 로고
    • An approach for measuring ultrasonic backscattering from biological tissues with focused transducers
    • Jul.
    • S. H. Wang and K. K. Shung, "An approach for measuring ultrasonic backscattering from biological tissues with focused transducers," IEEE Trans. Biomed. Eng., vol. BME-44, no. 7, pp. 549-554, Jul. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , Issue.7 BME-44 , pp. 549-554
    • Wang, S.H.1    Shung, K.K.2
  • 14
    • 0036714292 scopus 로고    scopus 로고
    • Characterization of tissue microstructure using ultrasonic backscatter: Theory and technique for optimization using a Gaussian form factor
    • M. L. Oelze, J. F. Zachary, and W. D. O'Brien Jr., "Characterization of tissue microstructure using ultrasonic backscatter: Theory and technique for optimization using a Gaussian form factor," J. Acoust. Soc. Amer., vol. 112, pp. 1202-1211, 2002.
    • (2002) J. Acoust. Soc. Amer. , vol.112 , pp. 1202-1211
    • Oelze, M.L.1    Zachary, J.F.2    O'Brien, Jr.W.D.3
  • 16
    • 84938208238 scopus 로고    scopus 로고
    • Experimental application of ultrafast imaging to spectral tissue characterization
    • J. Garcia-Duitama, B. Chayer, A. Han, D. Garcia, M. L. Oelze, and G. Cloutier, "Experimental application of ultrafast imaging to spectral tissue characterization," Ultrasound Med. Biol., vol. 41, no. 9, pp. 2506-2519, 2015.
    • (2015) Ultrasound Med. Biol. , vol.41 , Issue.9 , pp. 2506-2519
    • Garcia-Duitama, J.1    Chayer, B.2    Han, A.3    Garcia, D.4    Oelze, M.L.5    Cloutier, G.6
  • 17
    • 2942689376 scopus 로고    scopus 로고
    • Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter
    • M. L. Oelze and W. D. O'Brien Jr., "Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter," J. Acoust. Soc. Amer., vol. 115, pp. 3226-3234, 2004.
    • (2004) J. Acoust. Soc. Amer. , vol.115 , pp. 3226-3234
    • Oelze, M.L.1    O'Brien, Jr.W.D.2
  • 18
    • 0029760044 scopus 로고    scopus 로고
    • Precision and accuracy of acoustospectrographic parameters
    • H. J. Huisman and J. M. Thijssen, "Precision and accuracy of acoustospectrographic parameters," Ultrasound Med. Biol., vol. 22, pp. 855-871, 1996.
    • (1996) Ultrasound Med. Biol. , vol.22 , pp. 855-871
    • Huisman, H.J.1    Thijssen, J.M.2
  • 20
    • 9644254231 scopus 로고    scopus 로고
    • Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gateedge correction factor
    • M. L. Oelze and W. D. O'Brien Jr., "Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gateedge correction factor," J. Acoust. Soc. Amer., vol. 116, pp. 3212-3223, 2004.
    • (2004) J. Acoust. Soc. Amer. , vol.116 , pp. 3212-3223
    • Oelze, M.L.1    O'Brien, W. D.2
  • 21
    • 84908144695 scopus 로고
    • The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms
    • Jun.
    • P. D. Welch, "The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms," IEEE Trans. Audio Electroacoust., vol. U-15, no. 2, pp. 70-73, Jun. 1967.
    • (1967) IEEE Trans. Audio Electroacoust. , Issue.2 U-15 , pp. 70-73
    • Welch, P.D.1
  • 22
    • 78650371603 scopus 로고    scopus 로고
    • Improved scatterer property estimates from ultrasound backscatter using gate-edge correction and a pseudo-Welch technique
    • Dec.
    • G. Ghoshal and M. L. Oelze, "Improved scatterer property estimates from ultrasound backscatter using gate-edge correction and a pseudo-Welch technique," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 12, pp. 2828-2832, Dec. 2010.
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.12 , pp. 2828-2832
    • Ghoshal, G.1    Oelze, M.L.2
  • 23
    • 77952560080 scopus 로고    scopus 로고
    • Trade-offs in data acquisition and processing parameters for backscatter and scatterer size estimations
    • Feb.
    • W. Liu and J. A. Zagzebski, "Trade-offs in data acquisition and processing parameters for backscatter and scatterer size estimations," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 2, pp. 340-352, Feb. 2010.
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.2 , pp. 340-352
    • Liu, W.1    Zagzebski, J.A.2
  • 24
    • 84869069574 scopus 로고    scopus 로고
    • Performance of various spectral estimation methods on backscatter coefficient estimation under data size limitations
    • I. M. Rosado-Mendez, K. Nam, T. J. Hall, and J. A. Zagzebski, "Performance of various spectral estimation methods on backscatter coefficient estimation under data size limitations," in Proc. IEEE Ultrason. Symp., Orlando, FL, USA, pp. 49-53, 2011.
    • (2011) Proc. IEEE Ultrason. Symp., Orlando, FL, USA , pp. 49-53
    • Rosado-Mendez, I.M.1    Nam, K.2    Hall, T.J.3    Zagzebski, J.A.4
  • 25
    • 84938196478 scopus 로고    scopus 로고
    • Statistics of scatterer property estimates
    • J. Mamou and M. L. Oelze, Eds. New York, NY, USA: Springer
    • M. L. Oelze, "Statistics of scatterer property estimates," in Quantitative Ultrasound in Soft Tissues, J. Mamou and M. L. Oelze, Eds. New York, NY, USA: Springer, 2013.
    • (2013) Quantitative Ultrasound in Soft Tissues
    • Oelze, M.L.1
  • 26
    • 0030040070 scopus 로고    scopus 로고
    • Error bounds on ultrasonic scatterer size estimates
    • P. Chaturvedit and M. F. Insana, "Error bounds on ultrasonic scatterer size estimates," J. Acoust. Soc. Amer., vol. 100, pp. 392-399, 1996.
    • (1996) J. Acoust. Soc. Amer. , vol.100 , pp. 392-399
    • Chaturvedit, P.1    Insana, M.F.2
  • 27
    • 0030734458 scopus 로고    scopus 로고
    • Bayesian and least squares approaches to ultrasonic scatterer size image formation
    • Jan.
    • P. Chaturvedit andM. F. Insana, "Bayesian and least squares approaches to ultrasonic scatterer size image formation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 44, no. 1, pp. 152-160, Jan. 1997.
    • (1997) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.44 , Issue.1 , pp. 152-160
    • Chaturvedit, P.1    Insana, M.F.2
  • 28
    • 3042528696 scopus 로고    scopus 로고
    • Improved parametric imaging of scatterer size estimates using angular compounding
    • Jun.
    • A. L. Gerig, T. Varghese, and J. A. Zagzebski, "Improved parametric imaging of scatterer size estimates using angular compounding," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 51, no. 6, pp. 708-715, Jun. 2004.
    • (2004) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.51 , Issue.6 , pp. 708-715
    • Gerig, A.L.1    Varghese, T.2    Zagzebski, J.A.3
  • 30
    • 77955015301 scopus 로고    scopus 로고
    • Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms
    • J. J.,erson et al., "Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms," Ultrason. Imaging, vol. 32, pp. 48-64, 2010.
    • (2010) Ultrason. Imaging , vol.32 , pp. 48-64
    • Erson, J.J.1
  • 31
    • 77954514901 scopus 로고    scopus 로고
    • Cross-imaging platform comparison of ultrasonic backscatter coefficient measurements of live rat tumors
    • L. A.Wirtzfeld et al., "Cross-imaging platform comparison of ultrasonic backscatter coefficient measurements of live rat tumors," J. Ultrasound Med., vol. 29, pp. 1117-1123, 2010.
    • (2010) J. Ultrasound Med. , vol.29 , pp. 1117-1123
    • Wirtzfeld, A.L.1
  • 32
    • 84861082838 scopus 로고    scopus 로고
    • Ultrasonic attenuation and backscatter coefficient estimates of rodent-tumor mimicking structures: Comparison of results among clinical scanners
    • K. Nam et al., "Ultrasonic attenuation and backscatter coefficient estimates of rodent-tumor mimicking structures: Comparison of results among clinical scanners," Ultrason. Imaging, vol. 33, pp. 233-250, 2011.
    • (2011) Ultrason. Imaging , vol.33 , pp. 233-250
    • Nam, K.1
  • 33
    • 84866285550 scopus 로고    scopus 로고
    • Cross-imaging system comparison of backscatter coefficient estimates from tissue-mimicking sample
    • K. Nam et al., "Cross-imaging system comparison of backscatter coefficient estimates from tissue-mimicking sample," J. Acoust. Soc. Amer., vol. 132, pp. 1319-1324, 2012.
    • (2012) J. Acoust. Soc. Amer. , vol.132 , pp. 1319-1324
    • Nam, K.1
  • 36
    • 0020062460 scopus 로고
    • Evaluation of backscattering coefficients for excised human tissues: Results, interpretation, and associated measurements
    • D. Nicholas, "Evaluation of backscattering coefficients for excised human tissues: Results, interpretation, and associated measurements," Ultrasound Med. Biol., vol. 8, pp. 17-28, 1982.
    • (1982) Ultrasound Med. Biol. , vol.8 , pp. 17-28
    • Nicholas, D.1
  • 37
    • 0022534694 scopus 로고
    • The use of angular scattering measurements to estimate structural parameters of human and animal tissues
    • D. K. Nassiri and C. R. Hill, "The use of angular scattering measurements to estimate structural parameters of human and animal tissues," J. Acoust. Soc. Amer., vol. 79, pp. 2048-2054, 1986.
    • (1986) J. Acoust. Soc. Amer. , vol.79 , pp. 2048-2054
    • Nassiri, D.K.1    Hill, C.R.2
  • 38
    • 0026095758 scopus 로고
    • Identifying acoustic scattering sources in normal renal parenchyma from the anisotropy in acoustic properties
    • M. F. Insana, T. J. Hall, and J. L. Fishback, "Identifying acoustic scattering sources in normal renal parenchyma from the anisotropy in acoustic properties," Ultrasound Med. Biol., vol. 17, pp. 613-626, 1991.
    • (1991) Ultrasound Med. Biol. , vol.17 , pp. 613-626
    • Insana, M.F.1    Hall, T.J.2    Fishback, J.L.3
  • 39
    • 0026782122 scopus 로고
    • Identifying acoustic scattering sources in normal renal parenchyma in vivo by varying arterial and ureteral pressures
    • M. F. Insana, J. G. Wood, and T. J. Hall, "Identifying acoustic scattering sources in normal renal parenchyma in vivo by varying arterial and ureteral pressures," Ultrasound Med. Biol., vol. 18, pp. 587-599, 1992.
    • (1992) Ultrasound Med. Biol. , vol.18 , pp. 587-599
    • Insana, M.F.1    Wood, J.G.2    Hall, T.J.3
  • 40
    • 79955396170 scopus 로고    scopus 로고
    • Quantitative ultrasound estimates from populations of scatterer with continuous size distributions
    • Apr.
    • R. Lavarello and M. L. Oelze, "Quantitative ultrasound estimates from populations of scatterer with continuous size distributions," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 58, no. 4, pp. 744-753, Apr. 2011.
    • (2011) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.58 , Issue.4 , pp. 744-753
    • Lavarello, R.1    Oelze, M.L.2
  • 41
    • 84866708930 scopus 로고    scopus 로고
    • Quantitative ultrasound estimates from populations of scatterers with continuous size distributions-Effects of size estimator algorithm
    • Sep.
    • R. Lavarello and M. L. Oelze, "Quantitative ultrasound estimates from populations of scatterers with continuous size distributions-Effects of size estimator algorithm," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 59, no. 9, pp. 2066-2076, Sep. 2012.
    • (2012) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.59 , Issue.9 , pp. 2066-2076
    • Lavarello, R.1    Oelze, M.L.2
  • 42
    • 38849154555 scopus 로고    scopus 로고
    • Extended three-dimensional impedance map methods for identifying ultrasonic scattering sites
    • J. Mamou, M. L. Oelze,W. D. O'Brien Jr., J. F. Zachary, "Extended three-dimensional impedance map methods for identifying ultrasonic scattering sites," J. Acoust. Soc. Amer., vol. 123, pp. 1195-1208, 2008.
    • (2008) J. Acoust. Soc. Amer. , vol.123 , pp. 1195-1208
    • Mamou, J.1    Oelze, M.L.2    O'Brien, Jr.W.D.3    Zachary, J.F.4
  • 43
    • 71049142243 scopus 로고    scopus 로고
    • Biomedical ultrasound imaging from 1 to 1000 MHz
    • M. Kolios, "Biomedical ultrasound imaging from 1 to 1000 MHz," Can. Acoust., vol. 37, pp. 35-42, 2009.
    • (2009) Can. Acoust. , vol.37 , pp. 35-42
    • Kolios, M.1
  • 44
    • 84922260489 scopus 로고    scopus 로고
    • Structure function for highconcentration biophantoms of polydisperse scatterer sizes
    • Feb.
    • A. Han and W. D. O'Brien Jr., "Structure function for highconcentration biophantoms of polydisperse scatterer sizes," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 62, no. 2, pp. 303-318, Feb. 2015.
    • (2015) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.62 , Issue.2 , pp. 303-318
    • Han, A.1    O'Brien, Jr.W.D.2
  • 45
    • 85032751562 scopus 로고    scopus 로고
    • Perspectives on biomedical quantitative ultrasound imaging
    • May
    • J. Mamou, M. L. Oelze, W. D. O'Brien Jr., J. F. Zachary, "Perspectives on biomedical quantitative ultrasound imaging," IEEE Signal Process. Mag., vol. 23, no. 3, pp. 112-116, May 2006.
    • (2006) IEEE Signal Process. Mag. , vol.23 , Issue.3 , pp. 112-116
    • Mamou, J.1    Oelze, M.L.2    O'Brien, Jr.W.D.3    Zachary, J.F.4
  • 46
    • 14844342757 scopus 로고    scopus 로고
    • Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms
    • T. A. Bigelow, M. L. Oelze, and W. D. O'Brien Jr., "Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms," J. Acoust. Soc. Amer., vol. 117, pp. 1431-1439, 2005.
    • (2005) J. Acoust. Soc. Amer. , vol.117 , pp. 1431-1439
    • Bigelow, T.A.1    Oelze, M.L.2    O'Brien, Jr.W.D.3
  • 47
    • 54049123217 scopus 로고    scopus 로고
    • Hybrid spectral domain method for attenuation slope estimation
    • K. Hyungsuk and T. Varghese, "Hybrid spectral domain method for attenuation slope estimation," Ultrasound Med. Biol., vol. 34, pp. 1808-1819, 2008.
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 1808-1819
    • Hyungsuk, K.1    Varghese, T.2
  • 48
    • 82955198419 scopus 로고    scopus 로고
    • Simultaneous backscatter and attenuation estimation using a least squares method with constraints
    • K. Nam, J. A. Zagzebski, and T. J. Hall, "Simultaneous backscatter and attenuation estimation using a least squares method with constraints," Ultrasound Med. Biol., vol. 37, pp. 2096-2104, 2011.
    • (2011) Ultrasound Med. Biol. , vol.37 , pp. 2096-2104
    • Nam, K.1    Zagzebski, J.A.2    Hall, T.J.3
  • 49
    • 0036096812 scopus 로고    scopus 로고
    • Frequency-dependent attenuationcompensation functions for ultrasonic signals backscattered from
    • random media
    • M. L. Oelze and W. D. O'Brien Jr., "Frequency-dependent attenuationcompensation functions for ultrasonic signals backscattered from random media," J. Acoust. Soc. Amer., vol. 111, pp. 2308-2319, 2002.
    • (2002) J. Acoust. Soc. Amer. , vol.111 , pp. 2308-2319
    • Oelze, M.L.1    O'Brien, Jr.W.D.2
  • 50
    • 73949154082 scopus 로고    scopus 로고
    • Improved parameter estimates based on the homodyned K distribution
    • Nov.
    • D. P. Hruska and M. L. Oelze, "Improved parameter estimates based on the homodyned K distribution," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 11, pp. 2471-2481, Nov. 2009.
    • (2009) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.56 , Issue.11 , pp. 2471-2481
    • Hruska, D.P.1    Oelze, M.L.2
  • 51
    • 77953909941 scopus 로고    scopus 로고
    • A critical review and uniformized representation of statistical distributions modeling the ultrasound echo envelope
    • F. Destrempes and G. Cloutier, "A critical review and uniformized representation of statistical distributions modeling the ultrasound echo envelope," Ultrasound Med. Biol., vol. 36, pp. 1037-1051, 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 1037-1051
    • Destrempes, F.1    Cloutier, G.2
  • 52
    • 0029456955 scopus 로고
    • K distribution model of ultrasound speckle: Fractional order SNRs and log compression variance
    • V. Dutt and J. F. Greenleaf, "K distribution model of ultrasound speckle: Fractional order SNRs and log compression variance," in Proc. IEEE Ultrason. Symp., 1995, pp. 1375-1378.
    • (1995) Proc. IEEE Ultrason. Symp. , pp. 1375-1378
    • Dutt, V.1    Greenleaf, J.F.2
  • 53
    • 0028618935 scopus 로고
    • Ultrasound echo envelope analysis using a homodyned K distribution signal model
    • V. Dutt and J. F. Greenleaf, "Ultrasound echo envelope analysis using a homodyned K distribution signal model," Ultrason. Imaging, vol. 16, pp. 265-287, 1994.
    • (1994) Ultrason. Imaging , vol.16 , pp. 265-287
    • Dutt, V.1    Greenleaf, J.F.2
  • 54
    • 0017022589 scopus 로고
    • A model for non-Rayleigh sea echo
    • Nov.
    • E. Jakeman and P. N. Pusey, "A model for non-Rayleigh sea echo," IEEE Trans. Antennas Propag., vol. AP-24, no. 6, pp. 806-814, Nov. 1976.
    • (1976) IEEE Trans. Antennas Propag. , Issue.6 AP-24 , pp. 806-814
    • Jakeman, E.1    Pusey, P.N.2
  • 55
    • 0002613968 scopus 로고
    • On the statistics of K-distributed noise
    • E. Jakeman, "On the statistics of K-distributed noise," J. Phys. A, Math. Gen., vol. 13, pp. 31-48, 1980.
    • (1980) J. Phys. A, Math. Gen. , vol.13 , pp. 31-48
    • Jakeman, E.1
  • 56
    • 84885068768 scopus 로고    scopus 로고
    • Estimation method of the homodyned K distribution based on the mean intensity and two log moments
    • F. Destrempes, J. Poreé, and G. Cloutier, "Estimation method of the homodyned K distribution based on the mean intensity and two log moments," SIAM J. Imaging Sci., vol. 6, pp. 1499-1530, 2013.
    • (2013) SIAM J. Imaging Sci. , vol.6 , pp. 1499-1530
    • Destrempes, F.1    Poreé, J.2    Cloutier, G.3
  • 58
    • 0017515490 scopus 로고
    • A statistical model for urban radio propagation
    • Jul.
    • H. Suzuki, "A statistical model for urban radio propagation," IEEE Trans. Commun., vol. C-25, no. 7, pp. 673-680, Jul. 1977.
    • (1977) IEEE Trans. Commun. , Issue.7 C-25 , pp. 673-680
    • Suzuki, H.1
  • 59
    • 0035263390 scopus 로고    scopus 로고
    • Classification of ultrasonic B-mode images of breast masses using Nakagami distribution
    • Mar.
    • P. M. Shankar, V. A. Dumane, J. M. Ried, and V. Genis, "Classification of ultrasonic B-mode images of breast masses using Nakagami distribution," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 2, pp. 569-580, Mar. 2001.
    • (2001) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.48 , Issue.2 , pp. 569-580
    • Shankar, P.M.1    Dumane, V.A.2    Ried, J.M.3    Genis, V.4
  • 60
    • 0035498435 scopus 로고    scopus 로고
    • Ultrasonic tissue characterization using a generalized Nakagami model
    • Nov.
    • P. M. Shankar, "Ultrasonic tissue characterization using a generalized Nakagami model," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 6, pp. 1716-1720, Nov. 2001.
    • (2001) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.48 , Issue.6 , pp. 1716-1720
    • Shankar, P.M.1
  • 61
    • 58149260412 scopus 로고    scopus 로고
    • Classification of breast masses by ultrasonic Nakagami imaging: A feasibility study
    • P. H. Tsui, C. K. Yeh, C. C. Chang, and Y. Y. Liao, "Classification of breast masses by ultrasonic Nakagami imaging: A feasibility study," Phys. Med. Biol., vol. 53, pp. 6027-6044, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6027-6044
    • Tsui, P.H.1    Yeh, C.K.2    Chang, C.C.3    Liao, Y.Y.4
  • 62
    • 81855164724 scopus 로고    scopus 로고
    • Using ultrasound Nakagami imaging to assess liver fibrosis in rats
    • M. C. Ho et al., "Using ultrasound Nakagami imaging to assess liver fibrosis in rats," Ultrasonics, vol. 52, pp. 215-222, 2012.
    • (2012) Ultrasonics , vol.52 , pp. 215-222
    • Ho, M.C.1
  • 63
    • 84882236390 scopus 로고    scopus 로고
    • Potential of ultrasound Nakagami imaging in clinical tissue characterization
    • P. H. Tsui, "Potential of ultrasound Nakagami imaging in clinical tissue characterization," J. Med. Ultrasound, vol. 21, pp. 51-53, 2013.
    • (2013) J. Med. Ultrasound , vol.21 , pp. 51-53
    • Tsui, P.H.1
  • 64
    • 84922683636 scopus 로고    scopus 로고
    • Monitoring radiofrequency ablation using real-time ultrasound Nakagami imaging combined with frequency and temporal compounding techniques
    • Z. Zhou, S. Wu, C. Y. Wang, H. Y. Ma, C. C. Lin, and P. H. Tsui, "Monitoring radiofrequency ablation using real-time ultrasound Nakagami imaging combined with frequency and temporal compounding techniques," PLoS One, vol. 10, pp. 1-15, 2015.
    • (2015) PLoS One , vol.10 , pp. 1-15
    • Zhou, Z.1    Wu, S.2    Wang, C.Y.3    Ma, H.Y.4    Lin, C.C.5    Tsui, P.H.6
  • 65
    • 3142716010 scopus 로고    scopus 로고
    • Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10-58 MHz: Experimental results
    • G. Cloutier, M. Daronat, D. Savéry, D. Garcia, L. G. Durand, and F. S. Foster, "Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10-58 MHz: Experimental results," J. Acoust. Soc. Amer., vol. 116, pp. 566-577, 2004.
    • (2004) J. Acoust. Soc. Amer. , vol.116 , pp. 566-577
    • Cloutier, G.1    Daronat, M.2    Savéry, D.3    Garcia, D.4    Durand, L.G.5    Foster, F.S.6
  • 66
    • 84913619507 scopus 로고    scopus 로고
    • Artifact reduction of ultrasound Nakagami imaging by combining multifocus image reconstruction and the noiseassisted correlation algorithm
    • P. H. Tsui and Y. W. Tsai, "Artifact reduction of ultrasound Nakagami imaging by combining multifocus image reconstruction and the noiseassisted correlation algorithm," Ultrason. Imaging, vol. 37, pp. 53-69, 2015.
    • (2015) Ultrason. Imaging , vol.37 , pp. 53-69
    • Tsui, P.H.1    Tsai, Y.W.2
  • 67
  • 68
    • 0021645096 scopus 로고
    • Regional differences in the cyclic variation of myocardial backscatter that parallels regional differences in contractile performance
    • J. G. Mottley, R. M. Glueck, J. E. Perez, B. E. Sobel, and J. G. Miller, "Regional differences in the cyclic variation of myocardial backscatter that parallels regional differences in contractile performance," J. Acoust. Soc. Amer., vol. 76, pp. 1617-1623, 1984.
    • (1984) J. Acoust. Soc. Amer. , vol.76 , pp. 1617-1623
    • Mottley, J.G.1    Glueck, R.M.2    Perez, J.E.3    Sobel, B.E.4    Miller, J.G.5
  • 69
    • 0021485130 scopus 로고
    • Effects of myocardial contraction on ultrasonic backscatter before and after ischemia
    • B. Barzilai, E. I. Madaras, B. E. Sobel, J. G. Miller, and J. E. Perez, "Effects of myocardial contraction on ultrasonic backscatter before and after ischemia," Amer. J. Physiol., vol. 247, pp. H478-H483, 1984.
    • (1984) Amer. J. Physiol. , vol.247 , pp. H478-H483
    • Barzilai, B.1    Madaras, E.I.2    Sobel, B.E.3    Miller, J.G.4    Perez, J.E.5
  • 70
    • 0344878645 scopus 로고
    • Clinical tissue characterization: Online determination of magnitude and time delay of myocardial backscatter
    • J. Mobley, C. Banta, H. Gusssak, J. E. Perez, and J. G. Miller, "Clinical tissue characterization: Online determination of magnitude and time delay of myocardial backscatter," Video J. Echocardiogr., vol. 5, pp. 40-48, 1995.
    • (1995) Video J. Echocardiogr. , vol.5 , pp. 40-48
    • Mobley, J.1    Banta, C.2    Gusssak, H.3    Perez, J.E.4    Miller, J.G.5
  • 71
    • 58849122177 scopus 로고    scopus 로고
    • Intrinsic myoarchitectural differences between the left and right ventricals of fetal human hearts: An ultrasonic backscatter feasibility study
    • M. R. Holland, A. Gibson, C. Kirschner, D. Hicks, A. Ludomirsky, and G. Singh, "Intrinsic myoarchitectural differences between the left and right ventricals of fetal human hearts: An ultrasonic backscatter feasibility study," J. Amer. Soc. Echocardiogr., vol. 22, pp. 170-176, 2009.
    • (2009) J. Amer. Soc. Echocardiogr. , vol.22 , pp. 170-176
    • Holland, M.R.1    Gibson, A.2    Kirschner, C.3    Hicks, D.4    Ludomirsky, A.5    Singh, G.6
  • 72
    • 34548098633 scopus 로고    scopus 로고
    • Measurements of the cyclic variation of myocardial backscatter from two-dimensional echocardiographic images as an approach for characterizing diabetic cardiomyopathy
    • M. R. Holland et al., "Measurements of the cyclic variation of myocardial backscatter from two-dimensional echocardiographic images as an approach for characterizing diabetic cardiomyopathy," J. Cardiometab. Syndr., vol. 1, pp. 149-152, 2007.
    • (2007) J. Cardiometab. Syndr. , vol.1 , pp. 149-152
    • Holl, M.R.1
  • 73
    • 6344253031 scopus 로고    scopus 로고
    • Potential relationships among myocardial stiffness, the measured level of myocardial backscatter (image brightness"), and the magnitude of the systemic variation of backscatter (cyclic variation) over the heart cycle
    • M. R. Holland, K. D. Wallace, and J. G. Miller, "Potential relationships among myocardial stiffness, the measured level of myocardial backscatter ("image brightness"), and the magnitude of the systemic variation of backscatter (cyclic variation) over the heart cycle," J. Amer. Soc. Echocardiogr., vol. 17, pp. 1131-1137, 2004.
    • (2004) J. Amer. Soc. Echocardiogr. , vol.17 , pp. 1131-1137
    • Holland, M.R.1    Wallace, K.D.2    Miller, J.G.3
  • 74
    • 0026506429 scopus 로고
    • Abnormal myocardial acoustic properties in diabetic patients and their correlation with the severity of the disease
    • J. E. Perez et al., "Abnormal myocardial acoustic properties in diabetic patients and their correlation with the severity of the disease," J. Amer. Coll. Cardiol., vol. 19, pp. 1154-1162, 1992.
    • (1992) J. Amer. Coll. Cardiol. , vol.19 , pp. 1154-1162
    • Perez, J.E.1
  • 75
    • 0028946936 scopus 로고
    • Increased echodensity of myocardial wall in the diabetic heart: An ultrasound tissue characterization study
    • V. D. Bello et al., "Increased echodensity of myocardial wall in the diabetic heart: An ultrasound tissue characterization study," J. Amer. Coll. Cardiol., vol. 25, pp. 1408-1415, 1995.
    • (1995) J. Amer. Coll. Cardiol. , vol.25 , pp. 1408-1415
    • Bello, V.D.1
  • 76
    • 0024449113 scopus 로고
    • Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients
    • M. R. Milunski et al., "Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients," Circulation, vol. 80, pp. 491-503, 1989.
    • (1989) Circulation , vol.80 , pp. 491-503
    • Milunski, M.R.1
  • 77
    • 0037199424 scopus 로고    scopus 로고
    • Prognostic significance of ultrasound myocardial tissue characterization in patients with cardiac amyloidosis
    • J. Koyama, P. A. Ray-Sequin, and R. H. Falk, "Prognostic significance of ultrasound myocardial tissue characterization in patients with cardiac amyloidosis," Circulation, vol. 106, pp. 556-561, 2002.
    • (2002) Circulation , vol.106 , pp. 556-561
    • Koyama, J.1    Ray-Sequin, P.A.2    Falk, R.H.3
  • 78
    • 0038639602 scopus 로고    scopus 로고
    • Ultrasound tissue characterization detects preclinical myocardial structural changes in children affected by Duchenne muscular dystrophy
    • V. Giglio et al., "Ultrasound tissue characterization detects preclinical myocardial structural changes in children affected by Duchenne muscular dystrophy," J. Amer. Coll. Cardiol., vol. 42, pp. 309-316, 2003.
    • (2003) J. Amer. Coll. Cardiol. , vol.42 , pp. 309-316
    • Giglio, V.1
  • 79
    • 34249863855 scopus 로고    scopus 로고
    • Myocardial ultrasound tissue characterization in patients with chronic renal failure
    • M. Salvetti et al., "Myocardial ultrasound tissue characterization in patients with chronic renal failure," J. Amer. Soc. Nephrol., vol. 18, pp. 1953-1958, 2007.
    • (2007) J. Amer. Soc. Nephrol. , vol.18 , pp. 1953-1958
    • Salvetti, M.1
  • 80
    • 68949099453 scopus 로고    scopus 로고
    • Quantitative analysis of the magnitude and time delay of the cyclic variation of myocardial backscatter from asymptomatic type 2 diabetes mellitus subjects
    • A. A. Gibson et al., "Quantitative analysis of the magnitude and time delay of the cyclic variation of myocardial backscatter from asymptomatic type 2 diabetes mellitus subjects," Ultrasound Med. Biol., vol. 35, pp. 1458-1467, 2009.
    • (2009) Ultrasound Med. Biol. , vol.35 , pp. 1458-1467
    • Gibson, A.A.1
  • 81
    • 79954628173 scopus 로고    scopus 로고
    • Bayesian parameter estimation for characterizing the cyclic variation of echocardiographic backscatter to assess the hearts of asymptomatic type 2 diabetes mellitus subjects
    • C. C.,erson, A. A. Gibson, J. E. Schaffer, L. R. Peterson, M. R. Holland, and J. G. Miller, "Bayesian parameter estimation for characterizing the cyclic variation of echocardiographic backscatter to assess the hearts of asymptomatic type 2 diabetes mellitus subjects," Ultrasound Med. Biol., vol. 37, pp. 805-812, 2011.
    • (2011) Ultrasound Med. Biol. , vol.37 , pp. 805-812
    • Erson, C.C.1    Gibson, A.A.2    Schaffer, J.E.3    Peterson, L.R.4    Holland, M.R.5    Miller, J.G.6
  • 82
    • 2942609260 scopus 로고    scopus 로고
    • Differentiation and characterization of mammary fibroadenomas and 4T1 carcinomas using ultrasound parametric imaging
    • Jun.
    • M. L. Oelze, J. F. Zachary, and W. D. O'Brien Jr., "Differentiation and characterization of mammary fibroadenomas and 4T1 carcinomas using ultrasound parametric imaging," IEEE Trans. Med. Imag., vol. 23, no. 6, pp. 764-771, Jun. 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.23 , Issue.6 , pp. 764-771
    • Oelze, M.L.1    Zachary, J.F.2    O'Brien, Jr.W.D.3
  • 83
    • 33750724543 scopus 로고    scopus 로고
    • Examination of cancer in mouse models using quantitative ultrasound
    • M. L. Oelze and J. F. Zachary, "Examination of cancer in mouse models using quantitative ultrasound," Ultrasound Med. Biol., vol. 11, pp. 1639-1648, 2006.
    • (2006) Ultrasound Med. Biol. , vol.11 , pp. 1639-1648
    • Oelze, M.L.1    Zachary, J.F.2
  • 85
    • 0036829798 scopus 로고    scopus 로고
    • Parametric imaging of rat mammary tumors in vivo for the purposes of tissue characterization
    • M. L. Oelze, J. F. Zachary, and W. D. O'Brien Jr., "Parametric imaging of rat mammary tumors in vivo for the purposes of tissue characterization," J. Ultrasound Med., vol. 21, pp. 1201-1210, 2002.
    • (2002) J. Ultrasound Med. , vol.21 , pp. 1201-1210
    • Oelze, M.L.1    Zachary, J.F.2    O'Brien, Jr.W.D.3
  • 86
    • 84877096321 scopus 로고    scopus 로고
    • Quantitative ultrasound evaluation of tumour cell death response in locally advanced breast cancer patients receiving chemotherapy
    • A. Sadeghi-Naini et al., "Quantitative ultrasound evaluation of tumour cell death response in locally advanced breast cancer patients receiving chemotherapy," Clin. Cancer Res., vol. 19, pp. 2163-2174, 2013.
    • (2013) Clin. Cancer Res. , vol.19 , pp. 2163-2174
    • Sadeghi-Naini, A.1
  • 87
    • 84920929648 scopus 로고    scopus 로고
    • Non-invasive evaluation of breast cancer response to chemotherapy using quantitative ultrasonic backscatter parameters
    • L. Sannachi et al., "Non-invasive evaluation of breast cancer response to chemotherapy using quantitative ultrasonic backscatter parameters," Med. Imag. Anal., vol. 20, pp. 224-236, 2015.
    • (2015) Med. Imag. Anal. , vol.20 , pp. 224-236
    • Sannachi, L.1
  • 88
    • 84930834885 scopus 로고    scopus 로고
    • The added value of statistical modeling of backscatter properties in the management of breast lesions at ultrasound
    • Jun.
    • I. Trop et al., "The added value of statistical modeling of backscatter properties in the management of breast lesions at ultrasound," Radiology, vol. 275, no. 3, pp. 666-674, Jun. 2015.
    • (2015) Radiology , vol.275 , Issue.3 , pp. 666-674
    • Trop, I.1
  • 89
    • 84887823597 scopus 로고    scopus 로고
    • Characterization of thyroid cancer in mouse models using highfrequency quantitative ultrasound techniques
    • R. J. Lavarello, W. R. Ridgway, S. S. Sarwate, and M. L. Oelze, "Characterization of thyroid cancer in mouse models using highfrequency quantitative ultrasound techniques," Ultrasound Med. Biol., vol. 39, pp. 2333-2341, 2013.
    • (2013) Ultrasound Med. Biol. , vol.39 , pp. 2333-2341
    • Lavarello, R.J.1    Ridgway, W.R.2    Sarwate, S.S.3    Oelze, M.L.4
  • 91
    • 20144372793 scopus 로고    scopus 로고
    • Targeted expression of BRAFV600E in thyroid cells of transgenic mice results in papillary thyroid cancers that undergo dedifferentiation
    • J. A. Knauf et al., "Targeted expression of BRAFV600E in thyroid cells of transgenic mice results in papillary thyroid cancers that undergo dedifferentiation," Cancer Res., vol. 65, pp. 4238-4245, 2005.
    • (2005) Cancer Res. , vol.65 , pp. 4238-4245
    • Knauf, J.A.1
  • 92
    • 6444245375 scopus 로고    scopus 로고
    • Mice with a mutation in thyroid hormone receptor gene spontaneously develop thyroid carcinoma: A mouse model of thyroid carcinogenesis
    • H. Suzuki, M. C. Willingham, and S. Cheng, "Mice with a mutation in thyroid hormone receptor gene spontaneously develop thyroid carcinoma: A mouse model of thyroid carcinogenesis," Thyroid, vol. 12, pp. 963-969, 2002.
    • (2002) Thyroid , vol.12 , pp. 963-969
    • Suzuki, H.1    Willingham, M.C.2    Cheng, S.3
  • 93
    • 17644388485 scopus 로고    scopus 로고
    • Recent developments in tissue-type imaging (TTI) for planning and monitoring treatment of prostate cancer
    • E. J. Feleppa et al., "Recent developments in tissue-type imaging (TTI) for planning and monitoring treatment of prostate cancer," Ultrason. Imaging, vol. 26, pp. 163-172, 2004.
    • (2004) Ultrason. Imaging , vol.26 , pp. 163-172
    • Feleppa, E.J.1
  • 94
    • 0013290186 scopus 로고    scopus 로고
    • Ultrasonic spectrum-analysis and neural-network classification as a basis for ultrasonic imaging to target brachytherapy of prostate cancer
    • E. J. Feleppa et al., "Ultrasonic spectrum-analysis and neural-network classification as a basis for ultrasonic imaging to target brachytherapy of prostate cancer," Brachytherapy, vol. 1, pp. 48-53, 2002.
    • (2002) Brachytherapy , vol.1 , pp. 48-53
    • Feleppa, E.J.1
  • 95
    • 0035733544 scopus 로고    scopus 로고
    • Spectrum-analysis and neural networks for imaging to detect and treat prostate cancer
    • E. J. Feleppa et al., "Spectrum-analysis and neural networks for imaging to detect and treat prostate cancer," Ultrason. Imaging, vol. 23, pp. 135-146, 2001.
    • (2001) Ultrason. Imaging , vol.23 , pp. 135-146
    • Feleppa, E.J.1
  • 96
    • 0033755545 scopus 로고    scopus 로고
    • Three-dimensional ultrasound analyses of the prostate
    • E. J. Feleppa et al., "Three-dimensional ultrasound analyses of the prostate," Mol. Urol., vol. 4, pp. 133-139, 2001.
    • (2001) Mol. Urol. , vol.4 , pp. 133-139
    • Feleppa, E.J.1
  • 97
    • 77952840242 scopus 로고    scopus 로고
    • Prostate-cancer imaging using machine-learning classifiers: Potential value for guiding biopsies, targeting therapy, and monitoring treatment
    • E. J. Feleppa, M. J. Rondeau, P. Lee, and C. R. Porter, "Prostate-cancer imaging using machine-learning classifiers: Potential value for guiding biopsies, targeting therapy, and monitoring treatment," in Proc. IEEE Ultrason. Symp., Piscataway, NJ, USA, 2009, pp. 527-529.
    • (2009) Proc. IEEE Ultrason. Symp., Piscataway, NJ, USA , pp. 527-529
    • Feleppa, E.J.1    Rondeau, M.J.2    Lee, P.3    Porter, C.R.4
  • 98
    • 54949132919 scopus 로고    scopus 로고
    • Ultrasonic tissue-type imaging of the prostate: Implications for biopsy and treatment guidance
    • E. J. Feleppa, "Ultrasonic tissue-type imaging of the prostate: Implications for biopsy and treatment guidance," Cancer Biomarkers, vol. 4, pp. 201-212, 2008.
    • (2008) Cancer Biomarkers , vol.4 , pp. 201-212
    • Feleppa, E.J.1
  • 99
    • 84879125875 scopus 로고    scopus 로고
    • Three-dimensional quantitative ultrasound for detecting lymph node metastases
    • E. Saegusa-Beecroft et al., "Three-dimensional quantitative ultrasound for detecting lymph node metastases," J. Surg. Res., vol. 183, pp. 258-269, 2013.
    • (2013) J. Surg. Res. , vol.183 , pp. 258-269
    • Saegusa-Beecroft, E.1
  • 100
    • 79851479629 scopus 로고    scopus 로고
    • Three-dimensional high-frequency backscatter and envelope quantification of cancerous human lymph nodes
    • J. Mamou et al., "Three-dimensional high-frequency backscatter and envelope quantification of cancerous human lymph nodes," Ultrasound Med. Biol., vol. 37, pp. 345-357, 2011.
    • (2011) Ultrasound Med. Biol. , vol.37 , pp. 345-357
    • Mamou, J.1
  • 101
    • 76749141247 scopus 로고    scopus 로고
    • Three-dimensional high-frequency characterization of cancerous lymph nodes
    • J. Mamou et al., "Three-dimensional high-frequency characterization of cancerous lymph nodes," Ultrasound Med. Biol., vol. 36, pp. 361-375, 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 361-375
    • Mamou, J.1
  • 102
    • 77952793778 scopus 로고    scopus 로고
    • Three-dimensional high-frequency characterization of excised human lymph nodes
    • J. Mamou et al., "Three-dimensional high-frequency characterization of excised human lymph nodes," in Proc. IEEE Ultrason. Symp., Piscataway, NJ, USA, 2009, pp. 45-48.
    • (2009) Proc. IEEE Ultrason. Symp., Piscataway, NJ, USA , pp. 45-48
    • Mamou, J.1
  • 103
    • 84882312152 scopus 로고    scopus 로고
    • Lymph Explorer: A new GUI using 3D high-frequency quantitative ultrasound methods to guide pathologists towards metastatic regions in human lymph nodes
    • J. Mamou et al., "Lymph Explorer: A new GUI using 3D high-frequency quantitative ultrasound methods to guide pathologists towards metastatic regions in human lymph nodes," in Proc. IEEE Ultrason. Symp., Dresden, Germany, 2012, pp. 2340-2343.
    • (2012) Proc. IEEE Ultrason. Symp., Dresden, Germany , pp. 2340-2343
    • Mamou, J.1
  • 104
    • 0023106195 scopus 로고
    • Quantitative estimation of liver attenuation and echogenicity: Normal state versus diffuse liver disease
    • B. S. Garra, M. F. Insana, T. H. Shawker, and M. A. Russell, "Quantitative estimation of liver attenuation and echogenicity: Normal state versus diffuse liver disease," Radiology, vol. 162, pp. 61-67, 1987.
    • (1987) Radiology , vol.162 , pp. 61-67
    • Garra, B.S.1    Insana, M.F.2    Shawker, T.H.3    Russell, M.A.4
  • 105
    • 0025866714 scopus 로고
    • Ultrasound attenuation and texture analysis of diffuse liver disease: Methods and preliminary results
    • B. J. Oosterveld, J. M. Thijssen, P. C. Hartman, R. L. Romijn, and G. J. E. Rosenbusch, "Ultrasound attenuation and texture analysis of diffuse liver disease: Methods and preliminary results," Phys. Med. Biol., vol. 36, pp. 1039-1064, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1039-1064
    • Oosterveld, B.J.1    Thijssen, J.M.2    Hartman, P.C.3    Romijn, R.L.4    Rosenbusch, G.J.E.5
  • 106
    • 84863094444 scopus 로고    scopus 로고
    • Transcutaneous vs. Intraoperative quantitative ultrasound for staging bovine hepatic steatosis
    • G. Weijers et al., "Transcutaneous vs. intraoperative quantitative ultrasound for staging bovine hepatic steatosis," Ultrasound Med. Biol., vol. 38, pp. 1404-1413, 2012.
    • (2012) Ultrasound Med. Biol. , vol.38 , pp. 1404-1413
    • Weijers, G.1
  • 108
    • 70449158340 scopus 로고
    • A simple method for the isolation and purification of total lipids from animal tissues
    • J. Folch, M. Lees, and G. H. Sloane-Stanley, "A simple method for the isolation and purification of total lipids from animal tissues," J. Biol. Chem., vol. 226, pp. 497-509, 1957.
    • (1957) J. Biol. Chem. , vol.226 , pp. 497-509
    • Folch, J.1    Lees, M.2    Sloane-Stanley, G.H.3
  • 109
    • 84931574623 scopus 로고    scopus 로고
    • Noninvasive diagnosis of nonalcoholic fatty liver disease and quantification of liver fat using a new quantitative ultrasound technique
    • S. C. Lin et al., "Noninvasive diagnosis of nonalcoholic fatty liver disease and quantification of liver fat using a new quantitative ultrasound technique," Clin. Gastroenterol. Hepatol., vol. 13, pp. 1337-1345, 2015.
    • (2015) Clin. Gastroenterol. Hepatol. , vol.13 , pp. 1337-1345
    • Lin, S.C.1
  • 110
    • 34548431810 scopus 로고    scopus 로고
    • Prediction and prevention of recurrent spontaneous preterm birth
    • C. Y. Spong, "Prediction and prevention of recurrent spontaneous preterm birth," Obstet. Gynecol., vol. 110, pp. 405-415, 2007.
    • (2007) Obstet. Gynecol. , vol.110 , pp. 405-415
    • Spong, C.Y.1
  • 111
    • 37449004386 scopus 로고    scopus 로고
    • Preterm birth 1-epidemiology and causes of preterm birth
    • R. L. Goldenberg, J. F. Culhane, J. D. Iams, and R. Romero, "Preterm birth 1-epidemiology and causes of preterm birth," Lancet, vol. 371, pp. 75-84, 2008.
    • (2008) Lancet , vol.371 , pp. 75-84
    • Goldenberg, R.L.1    Culhane, J.F.2    Iams, J.D.3    Romero, R.4
  • 112
    • 77955435638 scopus 로고    scopus 로고
    • Quantitative ultrasound assessment of cervical microstructure
    • H. Feltovich, K. Nam, and T. J. Hall, "Quantitative ultrasound assessment of cervical microstructure," Ultrason. Imaging, vol. 32, pp. 131-142, 2010.
    • (2010) Ultrason. Imaging , vol.32 , pp. 131-142
    • Feltovich, H.1    Nam, K.2    Hall, T.J.3
  • 115
    • 77955435638 scopus 로고    scopus 로고
    • Quantitative ultrasound assessment of cervical microstructure
    • H. Feltovich, K. Nam, and T. J. Hall, "Quantitative ultrasound assessment of cervical microstructure," Ultrason. Imaging, vol. 32, pp. 131-142, 2010.
    • (2010) Ultrason. Imaging , vol.32 , pp. 131-142
    • Feltovich, H.1    Nam, K.2    Hall, T.J.3
  • 117
    • 84873342350 scopus 로고    scopus 로고
    • Quantitative imaging of the cervix: Setting the bar
    • H. Feltovich and T. J. Hall, "Quantitative imaging of the cervix: Setting the bar," Ultrasound Obstet. Gynecol., vol. 41, pp. 121-128, 2013.
    • (2013) Ultrasound Obstet. Gynecol. , vol.41 , pp. 121-128
    • Feltovich, H.1    Hall, T.J.2
  • 118
    • 84884767607 scopus 로고    scopus 로고
    • Nonlinear optical microscopy and ultrasound imaging of human cervical structure
    • L. M. Reusch et al., "Nonlinear optical microscopy and ultrasound imaging of human cervical structure," J. Biomed. Opt., vol. 18, p. 031110, 2013.
    • (2013) J. Biomed. Opt. , vol.18 , pp. 031110
    • Reusch, L.M.1
  • 119
    • 0034485819 scopus 로고    scopus 로고
    • Paclitaxel-induced apoptosis and mitotic arrest assessed by serial fine-needle aspiration: Implications for early prediction of breast cancer response to neoadjuvant treatment
    • W. F. Symmans et al., "Paclitaxel-induced apoptosis and mitotic arrest assessed by serial fine-needle aspiration: Implications for early prediction of breast cancer response to neoadjuvant treatment," Clin. Cancer Res., vol. 6, pp. 4610-4617, 2000.
    • (2000) Clin. Cancer Res. , vol.6 , pp. 4610-4617
    • Symmans, W.F.1
  • 120
    • 34247240410 scopus 로고    scopus 로고
    • Radiotherapy response in oral squamous carcinoma cell lines: Evaluation of apoptotic proteins as prognostic factors
    • K. Roberg, A. C. Jonsson, R. Grenman, and L. Norberg-Spaak, "Radiotherapy response in oral squamous carcinoma cell lines: Evaluation of apoptotic proteins as prognostic factors," Head Neck, vol. 29, pp. 325-334, 2007.
    • (2007) Head Neck , vol.29 , pp. 325-334
    • Roberg, K.1    Jonsson, A.C.2    Grenman, R.3    Norberg-Spaak, L.4
  • 121
    • 0030791041 scopus 로고    scopus 로고
    • Ultrasonic biomicroscopy of viable, dead and apoptotic cells
    • G. J. Czarnota et al., "Ultrasonic biomicroscopy of viable, dead and apoptotic cells," Ultrasound Med. Biol., vol. 23, pp. 961-965, 1997.
    • (1997) Ultrasound Med. Biol. , vol.23 , pp. 961-965
    • Czarnota, G.J.1
  • 122
    • 0032854611 scopus 로고    scopus 로고
    • Ultrasound imaging of apoptosis: High-resolution non-invasive monitoring of programmed cell death in vitro, in situ and in vivo
    • G. J. Czarnota et al., "Ultrasound imaging of apoptosis: High-resolution non-invasive monitoring of programmed cell death in vitro, in situ and in vivo," Brit. J. Cancer, vol. 81, pp. 520-527, 1999.
    • (1999) Brit. J. Cancer , vol.81 , pp. 520-527
    • Czarnota, G.J.1
  • 124
    • 4143097134 scopus 로고    scopus 로고
    • An investigation of backscatter power spectra from cells, cell pellets and microspheres
    • M. C. Kolios et al., "An investigation of backscatter power spectra from cells, cell pellets and microspheres," in Proc. IEEE Ultrason. Symp., Honolulu, HI, USA, 2003, pp. 752-757.
    • (2003) Proc. IEEE Ultrason. Symp., Honolulu, HI, USA , pp. 752-757
    • Kolios, M.C.1
  • 125
    • 23644433197 scopus 로고    scopus 로고
    • Monitoring structural changes in cells with highfrequency ultrasound signal statistics
    • A. S. Tunis, G. J. Czarnota, A. Giles, M. D. Sherar, J. W. Hunt, and M. C. Kolios, "Monitoring structural changes in cells with highfrequency ultrasound signal statistics," Ultrasound Med. Biol., vol. 31, pp. 878-881, 2005.
    • (2005) Ultrasound Med. Biol. , vol.31 , pp. 878-881
    • Tunis, A.S.1    Czarnota, G.J.2    Giles, A.3    Sherar, M.D.4    Hunt, J.W.5    Kolios, M.C.6
  • 127
    • 63449122523 scopus 로고    scopus 로고
    • Quantitative ultrasound characterization of responses to radiotherapy in cancer mouse models
    • R. M. Vlad, S. Brand, A. Giles, M. C. Kolios, and G. J. Czarnota, "Quantitative ultrasound characterization of responses to radiotherapy in cancer mouse models," Clin. Cancer Res., vol. 15, pp. 2067-2075, 2009.
    • (2009) Clin. Cancer Res. , vol.15 , pp. 2067-2075
    • Vlad, R.M.1    Brand, S.2    Giles, A.3    Kolios, M.C.4    Czarnota, G.J.5
  • 128
    • 79952202644 scopus 로고    scopus 로고
    • Ultrasound imaging of apoptosis: Spectroscopic detection of DNA-damage effects at high and low frequencies
    • R. M. Vlad, M. C. Kolios, and G. J. Czarnota, "Ultrasound imaging of apoptosis: Spectroscopic detection of DNA-damage effects at high and low frequencies," Methods Mol. Biol., vol. 682, pp. 165-187, 2011.
    • (2011) Methods Mol. Biol. , vol.682 , pp. 165-187
    • Vlad, R.M.1    Kolios, M.C.2    Czarnota, G.J.3
  • 129
    • 84881645876 scopus 로고    scopus 로고
    • Low-frequency quantitative ultrasound imaging of cell death in vivo
    • A. Sadeghi-Naini et al., "Low-frequency quantitative ultrasound imaging of cell death in vivo," Med. Phys., vol. 40, p. 082901, 2013.
    • (2013) Med. Phys. , vol.40 , pp. 082901
    • Sadeghi-Naini, A.1
  • 132
    • 0016413594 scopus 로고
    • Diagnosis of urethral flow parameters by ultrasonic backscatter
    • Jan.
    • R. J. Albright and J. H. Harris, "Diagnosis of urethral flow parameters by ultrasonic backscatter," IEEE Trans. Biomed. Eng., vol. BME-22, no. 1, pp. 1-11, Jan. 1975.
    • (1975) IEEE Trans. Biomed. Eng., Vol. BME-22 , Issue.1 , pp. 1-11
    • Albright, R.J.1    Harris, J.H.2
  • 133
    • 0015625563 scopus 로고
    • Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sine-wave bursts
    • R. A. Sigelmann and J. M. Reid, "Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sine-wave bursts," J. Acoust. Soc. Amer., vol. 53, p. 1351, 1973.
    • (1973) J. Acoust. Soc. Amer. , vol.53 , pp. 1351
    • Sigelmann, R.A.1    Reid, J.M.2
  • 134
    • 0343396560 scopus 로고    scopus 로고
    • Parameters of red blood cell aggregation as correlates of the inflammatory state
    • R. B. Ami et al., "Parameters of red blood cell aggregation as correlates of the inflammatory state," Amer. J. Physiol. Heart Circ. Physiol., vol. 280, pp. H1982-H1988, 2001.
    • (2001) Amer. J. Physiol. Heart Circ. Physiol. , vol.280 , pp. H1982-H1988
    • Ami, R.B.1
  • 135
    • 0023780814 scopus 로고
    • Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentration
    • Y. W. Yuan and K. K. Shung, "Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentration," J. Acoust. Soc. Amer., vol. 84, pp. 1195-1200, 1988.
    • (1988) J. Acoust. Soc. Amer. , vol.84 , pp. 1195-1200
    • Yuan, Y.W.1    Shung, K.K.2
  • 136
    • 0028072946 scopus 로고
    • Analysis of ultrasonic scattering in blood via a
    • continuum approach
    • K. K. Shung and I. Y. Kuo, "Analysis of ultrasonic scattering in blood via a continuum approach," Ultrasound Med. Biol., vol. 20, pp. 623-627, 1994.
    • (1994) Ultrasound Med. Biol. , vol.20 , pp. 623-627
    • Shung, K.K.1    Kuo, I.Y.2
  • 137
    • 0026065017 scopus 로고
    • Polydisperse scattering theory and comparisons with data for red blood cells
    • N. E. Berger, R. J. Lucas, and V. Twersky, "Polydisperse scattering theory and comparisons with data for red blood cells," J. Acoust. Soc. Amer., vol. 89, pp. 1394-1401, 1991.
    • (1991) J. Acoust. Soc. Amer. , vol.89 , pp. 1394-1401
    • Berger, N.E.1    Lucas, R.J.2    Twersky, V.3
  • 138
    • 0001002733 scopus 로고
    • Low-frequency scattering by correlated distributions of randomly oriented particles
    • V. Twersky, "Low-frequency scattering by correlated distributions of randomly oriented particles," J. Acoust. Soc. Amer., vol. 81, pp. 1609-1618, 1987.
    • (1987) J. Acoust. Soc. Amer. , vol.81 , pp. 1609-1618
    • Twersky, V.1
  • 139
    • 84967840986 scopus 로고
    • Low-frequency scattering by mixtures of correlated nonspherical particles
    • V. Twersky, "Low-frequency scattering by mixtures of correlated nonspherical particles," J. Acoust. Soc. Amer., vol. 84, pp. 409-415, 1988.
    • (1988) J. Acoust. Soc. Amer. , vol.84 , pp. 409-415
    • Twersky, V.1
  • 140
    • 0036214741 scopus 로고    scopus 로고
    • Simulation of ultrasound backscattering by red blood cell aggregates: Effect of shear rate and anisotropy
    • I. Fontaine, D. Savery, and G. Cloutier, "Simulation of ultrasound backscattering by red blood cell aggregates: Effect of shear rate and anisotropy," Biophys. J., vol. 82, pp. 1696-1710, 2002.
    • (2002) Biophys. J. , vol.82 , pp. 1696-1710
    • Fontaine, I.1    Savery, D.2    Cloutier, G.3
  • 141
    • 34547450230 scopus 로고    scopus 로고
    • Experimental ultrasound characterization of red blood cell aggregation using the structure factor size estimator
    • F. T. Yu and G. Cloutier, "Experimental ultrasound characterization of red blood cell aggregation using the structure factor size estimator," J. Acoust. Soc. Amer., vol. 122, pp. 645-656, 2007.
    • (2007) J. Acoust. Soc. Amer. , vol.122 , pp. 645-656
    • Yu, F.T.1    Cloutier, G.2
  • 142
    • 76349125319 scopus 로고    scopus 로고
    • Ultrasound characterization of red blood cell aggregation with intervening attenuating tissue-mimicking phantoms
    • E. Franceschini, F. T. Yu, F. Destrempes, and G. Cloutier, "Ultrasound characterization of red blood cell aggregation with intervening attenuating tissue-mimicking phantoms," J. Acoust. Soc. Amer., vol. 127, pp. 1104-1115, 2010.
    • (2010) J. Acoust. Soc. Amer. , vol.127 , pp. 1104-1115
    • Franceschini, E.1    Yu, F.T.2    Destrempes, F.3    Cloutier, G.4
  • 143
    • 84880958359 scopus 로고    scopus 로고
    • Ultrasound monitoring of RBC aggregation as a real-time marker of the inflammatory response in a cardiopulmonary bypass swine model
    • J. Tripette, A. Y. Denault, L. Allard, B. Chayer, L. P. Perrault, and G. Cloutier, "Ultrasound monitoring of RBC aggregation as a real-time marker of the inflammatory response in a cardiopulmonary bypass swine model," Crit. Care Med., vol. 41, pp. e171-e178, 2013.
    • (2013) Crit. Care Med. , vol.41 , pp. e171-e178
    • Tripette, J.1    Denault, A.Y.2    Allard, L.3    Chayer, B.4    Perrault, L.P.5    Cloutier, G.6
  • 144
    • 79952056552 scopus 로고    scopus 로고
    • A local increase in red blood cell aggregation can trigger deep vein thrombosis: Evidence based on quantitative cellular ultrasound imaging
    • F. T. Yu, J. K. Armstrong, J. Tripette, H. J. Meiselman, and G. Cloutier, "A local increase in red blood cell aggregation can trigger deep vein thrombosis: Evidence based on quantitative cellular ultrasound imaging," J. Thromb. Haemost., vol. 9, pp. 481-488, 2011.
    • (2011) J. Thromb. Haemost. , vol.9 , pp. 481-488
    • Yu, F.T.1    Armstrong, J.K.2    Tripette, J.3    Meiselman, H.J.4    Cloutier, G.5
  • 145
    • 84928403093 scopus 로고    scopus 로고
    • In vivo venous assessment of red blood cell aggregate sizes in diabetic patients with a quantitative cellular ultrasound imaging method: Proof of concept
    • e0124712(1)-e0124712(12)
    • J. Tripette, L. C. Nguyen, L. Allard, P. Robillard, G. Soulez, and G. Cloutier, "In vivo venous assessment of red blood cell aggregate sizes in diabetic patients with a quantitative cellular ultrasound imaging method: Proof of concept," PLoS One, vol. 10, pp. e0124712(1)-e0124712(12), 2015.
    • (2015) PLoS One , vol.10
    • Tripette, J.1    Nguyen, L.C.2    Allard, L.3    Robillard, P.4    Soulez, G.5    Cloutier, G.6
  • 146
    • 84856991221 scopus 로고    scopus 로고
    • Forward problem study of an effective medium model for ultrasound blood characterization
    • Dec.
    • E. Franceschini, B. Metzger, and G. Cloutier, "Forward problem study of an effective medium model for ultrasound blood characterization," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 58, no. 12, pp. 2668-2679, Dec. 2011.
    • (2011) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.58 , Issue.12 , pp. 2668-2679
    • Franceschini, E.1    Metzger, B.2    Cloutier, G.3
  • 147
    • 84887389740 scopus 로고    scopus 로고
    • Comparison of three scattering models for ultrasound blood characterization
    • Nov.
    • E. Franceschini, R. K. Saha, and G. Cloutier, "Comparison of three scattering models for ultrasound blood characterization," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 60, no. 11, pp. 2321-2334, Nov. 2013.
    • (2013) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.60 , Issue.11 , pp. 2321-2334
    • Franceschini, E.1    Saha, R.K.2    Cloutier, G.3
  • 148
    • 0032875680 scopus 로고    scopus 로고
    • Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements
    • E. L. Madsen et al., "Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements," J. Ultrasound Med., vol. 18, pp. 615-631, 1999.
    • (1999) J. Ultrasound Med. , vol.18 , pp. 615-631
    • Madsen, E.L.1
  • 149
    • 24144460550 scopus 로고    scopus 로고
    • Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz
    • K. A. Wear et al., "Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz," J. Ultrasound Med., vol. 24, pp. 1235-1250, 2005.
    • (2005) J. Ultrasound Med. , vol.24 , pp. 1235-1250
    • Wear, K.A.1
  • 150
    • 79959838707 scopus 로고    scopus 로고
    • Properties of phantom tissue like polymethylpentene in the frequency range 20-70 MHz
    • E. L. Madsen, M. E. Deaner, and J. Mehi, "Properties of phantom tissue like polymethylpentene in the frequency range 20-70 MHz," Ultrasound Med. Biol., vol. 37, pp. 1327-1339, 2011.
    • (2011) Ultrasound Med. Biol. , vol.37 , pp. 1327-1339
    • Madsen, E.L.1    Deaner, M.E.2    Mehi, J.3
  • 151
    • 80052495608 scopus 로고    scopus 로고
    • Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range
    • M. M. McCormick, E. L. Mdsen, M. E. Deaner, and T. Varghese, "Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range," J. Acoust. Soc. Amer., vol. 130, pp. 737-743, 2011.
    • (2011) J. Acoust. Soc. Amer. , vol.130 , pp. 737-743
    • McCormick, M.M.1    Mdsen, E.L.2    Deaner, M.E.3    Varghese, T.4
  • 152
    • 24944467368 scopus 로고    scopus 로고
    • Signal processing strategies that improve performance and understanding of the quantitative ultrasound spectral fit algorithm
    • T. A. Bigelow and W. D. O'Brien Jr., "Signal processing strategies that improve performance and understanding of the quantitative ultrasound spectral fit algorithm," J. Acoust. Soc. Amer., vol. 118, pp. 1808-1819, 2005.
    • (2005) J. Acoust. Soc. Amer. , vol.118 , pp. 1808-1819
    • Bigelow, T.A.1    O'Brien, W.D.2
  • 153
    • 79954459174 scopus 로고    scopus 로고
    • A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes
    • Y. Labyed and T. A. Bigelow, "A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes," J. Acoust. Soc. Amer., vol. 129, pp. 2316-2324, 2011.
    • (2011) J. Acoust. Soc. Amer. , vol.129 , pp. 2316-2324
    • Labyed, Y.1    Bigelow, T.A.2
  • 154
    • 84880340713 scopus 로고    scopus 로고
    • Taskoriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method
    • I. M. Rosado-Mendez, K. Nam, T. J. Hall, and J. A. Zagzebski, "Taskoriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method," Ultrason. Imaging, vol. 35, pp. 214-234, 2013.
    • (2013) Ultrason. Imaging , vol.35 , pp. 214-234
    • Rosado-Mendez, I.M.1    Nam, K.2    Hall, T.J.3    Zagzebski, J.A.4
  • 155
    • 84873203487 scopus 로고    scopus 로고
    • Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners
    • K. Nam et al., "Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners," Ultrason. Imaging, vol. 34, pp. 209-221, 2012.
    • (2012) Ultrason. Imaging , vol.34 , pp. 209-221
    • Nam, K.1
  • 156
    • 84875291008 scopus 로고    scopus 로고
    • Method for estimating total attenuation from a spatial map of attenuation slope for quantitative ultrasound imaging
    • A. D. Pawlicki andW. D. O'Brien Jr., "Method for estimating total attenuation from a spatial map of attenuation slope for quantitative ultrasound imaging," Ultrason. Imaging, vol. 35, pp. 162-172, 2013.
    • (2013) Ultrason. Imaging , vol.35 , pp. 162-172
    • Pawlicki, A.D.1    O'Brien, Jr.W.D.2
  • 157
    • 84863672554 scopus 로고    scopus 로고
    • Time domain attenuation estimation method from ultrasonic backscattered signals
    • G. Ghoshal and M. L. Oelze, "Time domain attenuation estimation method from ultrasonic backscattered signals," J. Acoust. Soc. Amer., vol. 132, pp. 533-543, 2012.
    • (2012) J. Acoust. Soc. Amer. , vol.132 , pp. 533-543
    • Ghoshal, G.1    Oelze, M.L.2
  • 158
    • 84861526572 scopus 로고    scopus 로고
    • Optimization of the algorithms for estimating the ultrasonic attenuation along the propagation path
    • Y. Labyed and T. A. Bigelow, "Optimization of the algorithms for estimating the ultrasonic attenuation along the propagation path," Ultrasonics, vol. 52, pp. 720-729, 2012.
    • (2012) Ultrasonics , vol.52 , pp. 720-729
    • Labyed, Y.1    Bigelow, T.A.2
  • 159
    • 77951039609 scopus 로고    scopus 로고
    • Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source
    • Apr.
    • T. A. Bigelow, "Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source," IEEE Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 4, pp. 900-907, Apr. 2010.
    • (2010) IEEE Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.4 , pp. 900-907
    • Bigelow, T.A.1
  • 160
    • 84955038759 scopus 로고
    • Sound scattering by solid cylinders and spheres
    • J. J. Faran Jr., "Sound scattering by solid cylinders and spheres," J. Acoust. Soc. Amer., vol. 23, p. 405, 1951.
    • (1951) J. Acoust. Soc. Amer. , vol.23 , pp. 405
    • Faran, Jr.J.J.1
  • 161
    • 79958000079 scopus 로고    scopus 로고
    • Analysis of human fibroadenomas using impedance maps
    • Jun.
    • A. J. Dapore et al., "Analysis of human fibroadenomas using impedance maps," IEEE Trans. Med. Imag., vol. 30, no. 6, pp. 1206-1213, Jun. 2011.
    • (2011) IEEE Trans. Med. Imag. , vol.30 , Issue.6 , pp. 1206-1213
    • Dapore, A.J.1
  • 162
    • 12344298662 scopus 로고    scopus 로고
    • Identifying ultrasonic scattering sites from three-dimensional impedance maps
    • J. Mamou, M. L. Oelze, W. D. O'Brien Jr., J. F. Zachary, "Identifying ultrasonic scattering sites from three-dimensional impedance maps," J. Acoust. Soc. Amer., vol. 117, pp. 413-423, 2005.
    • (2005) J. Acoust. Soc. Amer. , vol.117 , pp. 413-423
    • Mamou, J.1    Oelze, M.L.2    O'Brien, Jr.W.D.3    Zachary, J.F.4
  • 163
    • 80054065112 scopus 로고    scopus 로고
    • Effects of cell spatial organization and size distribution on ultrasound backscattering
    • Oct.
    • R. Saha and M. C. Kolios, "Effects of cell spatial organization and size distribution on ultrasound backscattering," IEEE Ultrason. Ferroelectr. Freq. Control, vol. 58, no. 10, pp. 2118-2131, Oct. 2011.
    • (2011) IEEE Ultrason. Ferroelectr. Freq. Control , vol.58 , Issue.10 , pp. 2118-2131
    • Saha, R.1    Kolios, M.C.2
  • 164
    • 84903148306 scopus 로고    scopus 로고
    • Structure factor model for understanding the measured backscatter coefficients from concentrated cell pellet biophantoms
    • E. Franceschini, R. Guillermin, F. Tournaire, S. Roffino, E. Lamy, and J. F. Landrier, "Structure factor model for understanding the measured backscatter coefficients from concentrated cell pellet biophantoms," J. Acoust. Soc. Amer., vol. 135, pp. 3620-3631, 2014.
    • (2014) J. Acoust. Soc. Amer. , vol.135 , pp. 3620-3631
    • Franceschini, E.1    Guillermin, R.2    Tournaire, F.3    Roffino, S.4    Lamy, E.5    Landrier, J.F.6
  • 165
    • 84903692646 scopus 로고    scopus 로고
    • Modeling the envelope statistics of three-dimensional high-frequency ultrasound echo signals from dissected human lymph nodes
    • T. M. Bui et al., "Modeling the envelope statistics of three-dimensional high-frequency ultrasound echo signals from dissected human lymph nodes," Jpn. J. Appl. Phys., vol. 53, 2014.
    • (2014) Jpn. J. Appl. Phys. , vol.53
    • Bui, T.M.1
  • 166
    • 84879816265 scopus 로고    scopus 로고
    • Probing red blood cell morphology using high-frequency photoacoustics
    • E. M. Strohm, E. S. L. Berndl, and M. C. Kolios, "Probing red blood cell morphology using high-frequency photoacoustics," Biophys. J., vol. 105, pp. 59-67, 2013.
    • (2013) Biophys. J. , vol.105 , pp. 59-67
    • Strohm, E.M.1    Berndl, E.S.L.2    Kolios, M.C.3
  • 167
    • 84896931790 scopus 로고    scopus 로고
    • The functional pitch of an organ: Quantification of tissue texture with photoacoustic spectrum analysis
    • G. Xu et al., "The functional pitch of an organ: Quantification of tissue texture with photoacoustic spectrum analysis," Radiology, vol. 271, pp. 248-254, 2014.
    • (2014) Radiology , vol.271 , pp. 248-254
    • Xu, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.