-
1
-
-
0037352102
-
Epidemiological Bonn Vein study by the German society of Phlebology: Epidemiological study to investigate the prevalence and severity of chronic venous disorders in the urban and rural residential populations [German]
-
Rabe E., Pannier-Fischer E., Bromen K., Schuldt K., Stang A., Poncar C., Wittenhorst M., Bock E., Weber S., Jöckel K. H., Bonn Vein study by the German society of Phlebology: Epidemiological Bonn Vein study by the German society of Phlebology: Epidemiological study to investigate the prevalence and severity of chronic venous disorders in the urban and rural residential populations [German], Phlebologie 32(1):1-14, 2003.
-
(2003)
Phlebologie
, vol.32
, Issue.1
, pp. 1-14
-
-
Rabe, E.1
Pannier-Fischer, E.2
Bromen, K.3
Schuldt, K.4
Stang, A.5
Poncar, C.6
Wittenhorst, M.7
Bock, E.8
Weber, S.9
Jöckel, K.H.10
-
2
-
-
0141509837
-
Prevalence of chronic venous insufficiency in men and women in Poland: Multicentre cross-sectional study in 40, 095 patients
-
Jawien A., Grzela T., Ochwat A., Prevalence of chronic venous insufficiency in men and women in Poland: Multicentre cross-sectional study in 40,095 patients, Phlebology 18(3):110-122, 2003.
-
(2003)
Phlebology
, vol.18
, Issue.3
, pp. 110-122
-
-
Jawien, A.1
Grzela, T.2
Ochwat, A.3
-
3
-
-
0028314416
-
Epidemiology of varicose veins
-
Callam M. J., Epidemiology of varicose veins, The British J. Surgery 81(2):167-173, 1994.
-
(1994)
The British J. Surgery
, vol.81
, Issue.2
, pp. 167-173
-
-
Callam, M.J.1
-
4
-
-
61349112072
-
Therapeutic value of muscular counterpulsation after coronary bypass grafting operation
-
Lapanashvili L. V., Buziashvili Y. I., Matskeplishvili S. T., Lobjanidze T. G., Yoshina V. I., Kamardinov D. K., Tugeeva E. F., Bockeria L. A., Therapeutic value of muscular counterpulsation after coronary bypass grafting operation, J. Cardiac Surgery 24(2):134-140, 2009.
-
(2009)
J. Cardiac Surgery
, vol.24
, Issue.2
, pp. 134-140
-
-
Lapanashvili, L.V.1
Buziashvili, Y.I.2
Matskeplishvili, S.T.3
Lobjanidze, T.G.4
Yoshina, V.I.5
Kamardinov, D.K.6
Tugeeva, E.F.7
Bockeria, L.A.8
-
5
-
-
4644245515
-
Muscular counterpulsation: Preliminary results of a non-invasive alternative to intra-aortic balloon pump
-
Tozzi P., Corno A. F., Lapanashvili L. V., Von Segesser L. K., Muscular counterpulsation: Preliminary results of a non-invasive alternative to intra-aortic balloon pump, Eur. J. Cardio-Thoracic Surgery (Official Journal of the European Association for Cardio-Thoracic Surgery) 26(4):726-729, 2004.
-
(2004)
Eur. J. Cardio-Thoracic Surgery (Official Journal of the European Association for Cardio-Thoracic Surgery)
, vol.26
, Issue.4
, pp. 726-729
-
-
Tozzi, P.1
Corno, A.F.2
Lapanashvili, L.V.3
Von Segesser, L.K.4
-
6
-
-
34447549116
-
ECGtriggered muscular counterpulsation for treatment of low cardiac output
-
Walpoth B. H., Aregger C., Lapanashvili L., Mettler D., Carrel T., Hess O. M., ECGtriggered muscular counterpulsation for treatment of low cardiac output, The Int. J. Artifi. Organs 30(5):407-414, 2007.
-
(2007)
The Int. J. Artifi. Organs
, vol.30
, Issue.5
, pp. 407-414
-
-
Walpoth, B.H.1
Aregger, C.2
Lapanashvili, L.3
Mettler, D.4
Carrel, T.5
Hess, O.M.6
-
7
-
-
42949143672
-
ECG-triggered skeletal muscle stimulation improves hemodynamics and physical performance of heart failure patients
-
Lapanashvili L., Buziashvili Y. I., Matskeplishvili S. T., Lobjanidze T. G., Bockeria L. A., Huber P. P., Hess O. M., Walpoth B. H., ECG-triggered skeletal muscle stimulation improves hemodynamics and physical performance of heart failure patients, The Int. J. Artifi. Organs 31(3):244-251, 2008.
-
(2008)
The Int. J. Artifi. Organs
, vol.31
, Issue.3
, pp. 244-251
-
-
Lapanashvili, L.1
Buziashvili, Y.I.2
Matskeplishvili, S.T.3
Lobjanidze, T.G.4
Bockeria, L.A.5
Huber, P.P.6
Hess, O.M.7
Walpoth, B.H.8
-
8
-
-
29244450126
-
Two-year clinical outcomes after enhanced external counterpulsation (EECP) therapy in patients with refractory angina pectoris and left ventricular dysfunction (report from the International EECP Patient Registry)
-
Soran O., Kennard E. D., Kfoury A. G., Kelsey S. F., Two-year clinical outcomes after enhanced external counterpulsation (EECP) therapy in patients with refractory angina pectoris and left ventricular dysfunction (report from The International EECP Patient Registry), The Am. J. Cardiol. 97(1):17-20, 2006.
-
(2006)
The Am. J. Cardiol
, vol.97
, Issue.1
, pp. 17-20
-
-
Soran, O.1
Kennard, E.D.2
Kfoury, A.G.3
Kelsey, S.F.4
-
9
-
-
84859619613
-
Enhanced external counterpulsation improves peripheral artery function and glucose tolerance in subjects with abnormal glucose tolerance
-
(Bethesda, Md. : 1985)
-
Martin J. S., Beck D. T., Aranda J. M., Braith R. W., Enhanced external counterpulsation improves peripheral artery function and glucose tolerance in subjects with abnormal glucose tolerance, J. Applied Physiolo (Bethesda, Md. : 1985) 112(5):868-876, 2012.
-
(2012)
J. Applied Physiolo
, vol.112
, Issue.5
, pp. 868-876
-
-
Martin, J.S.1
Beck, D.T.2
Aranda, J.M.3
Braith, R.W.4
-
10
-
-
34948876413
-
Enhanced external counterpulsation and future directions: Step beyond medical management for patients with angina and heart failure
-
Manchanda A., Soran, O., Enhanced external counterpulsation and future directions: Step beyond medical management for patients with angina and heart failure, J. Am. College Cardiol. 50(16):1523-1531, 2007.
-
(2007)
J. Am. College Cardiol
, vol.50
, Issue.16
, pp. 1523-1531
-
-
Manchanda, A.1
Soran, O.2
-
11
-
-
84973279953
-
Counter pulsation by triggered electrical stimulation of leg muscles for chronic heart failure treatment, Biomedizinische Technik
-
Brensing A., Stern A., Fischer D., Richter J., Romanowski T., Born R., Roedel H., Fritzsche D., Counter pulsation by triggered electrical stimulation of leg muscles for chronic heart failure treatment, Biomedizinische Technik. Biomedical Engineering 58:343-344 (2013).
-
(2013)
Biomedical Engineering
, vol.58
, pp. 343-344
-
-
Brensing, A.1
Stern, A.2
Fischer, D.3
Richter, J.4
Romanowski, T.5
Born, R.6
Roedel, H.7
Fritzsche, D.8
-
12
-
-
78349266402
-
Computational techniques for modeling non-Newtonian flow in porous media
-
Sochi T., Computational techniques for modeling non-newtonian flow in porous media, Int. J. Model. Simul. Sci. Comput. 01(02):239-256, 2010.
-
(2010)
Int. J. Model. Simul. Sci. Comput
, vol.1
, Issue.2
, pp. 239-256
-
-
Sochi, T.1
-
13
-
-
84897111378
-
Finite element model to study the effect of exogenous buffer on calcium dynamics in dendritic spines
-
Jha A., Adlakha N., Finite element model to study the effect of exogenous buffer on calcium dynamics in dendritic spines, Int. J. Model. Simul. Sci. Comput. 05(02):1350027, 2013.
-
(2013)
Int. J. Model. Simul. Sci. Comput
, vol.5
, Issue.2
-
-
Jha, A.1
Adlakha, N.2
-
14
-
-
84883659569
-
Particlebased transparent fused visualization applied to medical volume data
-
Hasegawa K., Ojima S., Shimokubo Y., Nakata S., Hachimura K., Tanaka S., Particlebased transparent fused visualization applied to medical volume data, Int. J. Model. Simul. Sci. Comput. 04(01):1341003, 2013.
-
(2013)
Int. J. Model. Simul. Sci. Comput
, vol.4
, Issue.1
-
-
Hasegawa, K.1
Ojima, S.2
Shimokubo, Y.3
Nakata, S.4
Hachimura, K.5
Tanaka, S.6
-
16
-
-
0014579518
-
Computer simulation studies of the venous circulation
-
Snyder M. F., Rideout, V. C., Computer simulation studies of the venous circulation, IEEE Trans. Bio-Med. Eng. 16(4):325-334, 1969.
-
(1969)
IEEE Trans. Bio-Med. Eng
, vol.16
, Issue.4
, pp. 325-334
-
-
Snyder, M.F.1
Rideout, V.C.2
-
17
-
-
0014067893
-
Electrical stimulation of skeletal muscle - A study of muscle as an actuator
-
CrochetiereW. J., Vodovnik L., Reswick J. B., Electrical stimulation of skeletal muscle - A study of muscle as an actuator, Med. Biol. Eng. 5(2):111-125, 1967.
-
(1967)
Med. Biol. Eng
, vol.5
, Issue.2
, pp. 111-125
-
-
Crochetiere, W.J.1
Vodovnik, L.2
Reswick, J.B.3
-
18
-
-
77950980225
-
Popliteal blood flow and plantar flexion force due to neuromuscular electrical stimulation (nmes) of the calf muscle pump are strongly associated with NMES intensity: Engineering in medicine and biology society, 2009
-
Corley G. J., Birlea S. I., Breen P., OLaighin G., (eds), Popliteal Blood Flow and Plantar Flexion Force due to Neuromuscular Electrical Stimulation (NMES) of the Calf Muscle Pump are Strongly Associated with NMES Intensity: Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE (2009).
-
(2009)
EMBC 2009. Annual International Conference of the IEEE
-
-
Corley, G.J.1
Birlea, S.I.2
Breen, P.3
Olaighin, G.4
-
19
-
-
0003921981
-
-
Ch. C. Thomas Springfield, IL, US
-
Nyboer J., Electrical Impedance Plethysmography - The Electrical Resistive Measure of the Blood Pulse Volume, Peripheral and Central Blood Flow (Ch. C. Thomas, Springfield, IL, US, 1970).
-
(1970)
Electrical Impedance Plethysmography - The Electrical Resistive Measure of the Blood Pulse Volume, Peripheral and Central Blood Flow
-
-
Nyboer, J.1
-
20
-
-
0028946777
-
Deep vein thrombosis: Prevention in stroke patients during rehabilitation
-
Pambianco G., Orchard T., Landau P., Deep vein thrombosis: Prevention in stroke patients during rehabilitation, Arch. Phys. Med. Rehabil. 76(4):324-330, 1995.
-
(1995)
Arch. Phys. Med. Rehabil
, vol.76
, Issue.4
, pp. 324-330
-
-
Pambianco, G.1
Orchard, T.2
Landau, P.3
-
21
-
-
0034743997
-
Numerical simulation of enhanced external counterpulsation
-
Ozawa E. T., Bottom K. E., Xiao X., Kamm R. D., Numerical simulation of enhanced external counterpulsation, Ann. Biomed. Eng. 29(4):284-297, 2001.
-
(2001)
Ann. Biomed. Eng
, vol.29
, Issue.4
, pp. 284-297
-
-
Ozawa, E.T.1
Bottom, K.E.2
Xiao, X.3
Kamm, R.D.4
-
22
-
-
0842265890
-
Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic Doppler echocardiography
-
Takeuchi M., Nohtomi Y., Yoshitani H., Miyazaki C., Sakamoto K., Yoshikawa J., Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic Doppler echocardiography, J. Am. College Cardiol. 43(3):368-376, 2004.
-
(2004)
J. Am. College Cardiol
, vol.43
, Issue.3
, pp. 368-376
-
-
Takeuchi, M.1
Nohtomi, Y.2
Yoshitani, H.3
Miyazaki, C.4
Sakamoto, K.5
Yoshikawa, J.6
-
23
-
-
78649632596
-
The efficacy of a new stimulation technology to increase venous flow and prevent venous stasis
-
Griffin M., Nicolaides A. N., Bond D., Geroulakos G., Kalodiki E., The efficacy of a new stimulation technology to increase venous flow and prevent venous stasis, Eur. J. Vascular Endovascular Surgery (The Official Journal of the European Society for Vascular Surgery) 40(6):766-771, 2010.
-
(2010)
Eur. J. Vascular Endovascular Surgery (the Official Journal of the European Society for Vascular Surgery)
, vol.40
, Issue.6
, pp. 766-771
-
-
Griffin, M.1
Nicolaides, A.N.2
Bond, D.3
Geroulakos, G.4
Kalodiki, E.5
|