메뉴 건너뛰기




Volumn 40, Issue 6, 2010, Pages 766-771

The efficacy of a new stimulation technology to increase venous flow and prevent venous stasis

Author keywords

Calf muscle stimulation; Deep vein thrombosis (DVT); Thrombo prophylaxis; Ultrasonic venous imaging; Venous stasis

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; BLOOD VOLUME; CLINICAL ARTICLE; DEEP VEIN THROMBOSIS; ELECTRODE; ELECTROSTIMULATION; FEMALE; GASTROCNEMIUS MUSCLE; HEART BEAT; HEART EJECTION FRACTION; HEART STROKE VOLUME; HUMAN; MALE; PEAK SYSTOLIC VELOCITY; POPLITEAL VEIN; PRIORITY JOURNAL; RISK FACTOR; SYSTOLIC BLOOD PRESSURE; ULTRASOUND; VEIN BLOOD FLOW; VENOUS STASIS;

EID: 78649632596     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2010.06.019     Document Type: Article
Times cited : (55)

References (15)
  • 1
    • 0000286848 scopus 로고
    • A simple way to combat the venous stasis which occurs in the lower limbs during surgical operations
    • F.S.A. Doran, M. Drury, and A. Sivyer A simple way to combat the venous stasis which occurs in the lower limbs during surgical operations Br J Surg 51 1964 486 492
    • (1964) Br J Surg , vol.51 , pp. 486-492
    • Doran, F.S.A.1    Drury, M.2    Sivyer, A.3
  • 2
    • 0014114684 scopus 로고
    • A demonstration that the risk of postoperative deep venous thrombosis is reduced by stimulating the calf muscles electrically during the operation
    • F.S.A. Doran, and H.M. White A demonstration that the risk of postoperative deep venous thrombosis is reduced by stimulating the calf muscles electrically during the operation Brit J Surg 54 1967 686 690
    • (1967) Brit J Surg , vol.54 , pp. 686-690
    • Doran, F.S.A.1    White, H.M.2
  • 3
    • 0014707552 scopus 로고
    • A clinical trial designed to test the relative value of two simple methods of reducing the risk of venous stasis in the lower limbs during surgical operations, the danger of thrombosis and a subsequent pulmonary embolus, with a survey of the problem
    • F.S.A. Doran, H.M. White, and M. Drury A clinical trial designed to test the relative value of two simple methods of reducing the risk of venous stasis in the lower limbs during surgical operations, the danger of thrombosis and a subsequent pulmonary embolus, with a survey of the problem Brit J Surg 57 1970 20 30
    • (1970) Brit J Surg , vol.57 , pp. 20-30
    • Doran, F.S.A.1    White, H.M.2    Drury, M.3
  • 4
    • 0014942668 scopus 로고
    • Prevention of postoperative leg vein thrombosis by electrical muscle stimulation:an evaluation with 125I-labelled fibrinogen
    • N.L. Browse, and D. Negus Prevention of postoperative leg vein thrombosis by electrical muscle stimulation:an evaluation with 125I-labelled fibrinogen Br Med J 3 1970 615 618
    • (1970) Br Med J , vol.3 , pp. 615-618
    • Browse, N.L.1    Negus, D.2
  • 5
    • 84965277013 scopus 로고
    • Optimal electrical stimulus for prevention of deep vein thrombosis
    • A.N. Nicolaides, V.V. Kakkar, E.S. Field, and P. Fish Optimal electrical stimulus for prevention of deep vein thrombosis Br Med J 3 1972 756 758
    • (1972) Br Med J , vol.3 , pp. 756-758
    • Nicolaides, A.N.1    Kakkar, V.V.2    Field, E.S.3    Fish, P.4
  • 6
    • 0020049969 scopus 로고
    • Electrically induced short-lasting tetanus of the calf muscles for prevention of deep vein thrombosis
    • B. Lindstrom, B.K. Korsan, O. Jonsson, B. Petruson, S. Petterson, and J. Wikstrand Electrically induced short-lasting tetanus of the calf muscles for prevention of deep vein thrombosis Br J Surg 69 1982 203 206
    • (1982) Br J Surg , vol.69 , pp. 203-206
    • Lindstrom, B.1    Korsan, B.K.2    Jonsson, O.3    Petruson, B.4    Petterson, S.5    Wikstrand, J.6
  • 7
    • 18144416154 scopus 로고    scopus 로고
    • Electro-stimulation for the prevention of deep venous thrombosis in patients with major trauma: A prospective randomized study
    • G.C. Velmahos, P. Petrone, L.S. Chen, S.E. Hanke, C.V. Brown, and D. Demetriades Electro-stimulation for the prevention of deep venous thrombosis in patients with major trauma: a prospective randomized study Surgery 137 2005 493 498
    • (2005) Surgery , vol.137 , pp. 493-498
    • Velmahos, G.C.1    Petrone, P.2    Chen, L.S.3    Hanke, S.E.4    Brown, C.V.5    Demetriades, D.6
  • 9
    • 58349083685 scopus 로고    scopus 로고
    • Effect of electro-stimulation (veinoplus) on lower limbs venous insufficiency-related symptoms during pregnancy. Preliminary study
    • A. LeTohic, H. Bastian, M. Pujo, P. Beslot, R. Mollard, and P. Madlenat Effect of electro-stimulation (veinoplus) on lower limbs venous insufficiency-related symptoms during pregnancy. Preliminary study Gynecol Obstet & Fertil 37 2009 18 24
    • (2009) Gynecol Obstet & Fertil , vol.37 , pp. 18-24
    • Letohic, A.1    Bastian, H.2    Pujo, M.3    Beslot, P.4    Mollard, R.5    Madlenat, P.6
  • 10
    • 0022800805 scopus 로고
    • Measurement of volume flow in the human common femoral artery using a duplex ultrasound system
    • P. Lewis, J.V. Psaila, W.T. Davies, B.P. Brown, and T.J. Barloon Measurement of volume flow in the human common femoral artery using a duplex ultrasound system Ultrasound Med Biol 12 1986 777 784
    • (1986) Ultrasound Med Biol , vol.12 , pp. 777-784
    • Lewis, P.1    Psaila, J.V.2    Davies, W.T.3    Brown, B.P.4    Barloon, T.J.5
  • 12
    • 0029946520 scopus 로고    scopus 로고
    • Prophylaxis against deep venous thrombosis after total knee arthroplasty. Pneumatic Pplantar compression and aspirin compared with aspirin alone
    • G.H. Westrich, and T.P. Sculco Prophylaxis against deep venous thrombosis after total knee arthroplasty. Pneumatic Pplantar compression and aspirin compared with aspirin alone J Bone Joint Surg [Am] 78-A 1996 826 834
    • (1996) J Bone Joint Surg [Am] , vol.78 , pp. 826-834
    • Westrich, G.H.1    Sculco, T.P.2
  • 13
    • 0034261541 scopus 로고    scopus 로고
    • Patient compliance and satisfaction with mechanical devices for preventing deep venous thrombosis after joint replacement
    • K.A. Robertson, A.J. Bertot, M.W. Wolfe, and R.L. Barrack Patient compliance and satisfaction with mechanical devices for preventing deep venous thrombosis after joint replacement J South Orthop Assoc. 9 3 2000 182 186
    • (2000) J South Orthop Assoc. , vol.9 , Issue.3 , pp. 182-186
    • Robertson, K.A.1    Bertot, A.J.2    Wolfe, M.W.3    Barrack, R.L.4
  • 14
    • 78049485603 scopus 로고    scopus 로고
    • Mechanical methods for thrombosis prophylaxis
    • J.A. Caprini Mechanical methods for thrombosis prophylaxis Clin Appl Thromb Hemost 2009 Oct 22 [Epub ahead of print]
    • (2009) Clin Appl Thromb Hemost
    • Caprini, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.