메뉴 건너뛰기




Volumn 21, Issue 4, 2015, Pages 491-500

Subjective Evaluation of a Semi-Automatic Optical See-Through Head-Mounted Display Calibration Technique

Author keywords

Calibration; eye tracking; INDICA; OST HMD; SPAAM; user study

Indexed keywords

AUGMENTED REALITY; AUTOMATION; HELMET MOUNTED DISPLAYS; QUALITY CONTROL; RECYCLING; SENSORY PERCEPTION; STREET TRAFFIC CONTROL;

EID: 84961318603     PISSN: 10772626     EISSN: None     Source Type: Journal    
DOI: 10.1109/TVCG.2015.2391856     Document Type: Article
Times cited : (29)

References (27)
  • 1
    • 79956287889 scopus 로고    scopus 로고
    • Parameter estimation variance of the single point active alignment method in optical see-through head mounted display calibration
    • M. Axholt, M. A. Skoglund, S. D. O'Connell, M. Cooper, and S. R. Ellis. Parameter estimation variance of the single point active alignment method in optical see-through head mounted display calibration. In Proceedings of the IEEE Virtual Reality Conference, pages 27-34, 2011.
    • (2011) Proceedings of the IEEE Virtual Reality Conference , pp. 27-34
    • Axholt, M.1    Skoglund, M.A.2    O'Connell, S.D.3    Cooper, M.4    Ellis, S.R.5
  • 5
    • 84926004684 scopus 로고    scopus 로고
    • Corneal imaging revisited: An overview of corneal reflection analysis and applications
    • A. N. C. Nitschke and H. Takemura. Corneal imaging revisited: An overview of corneal reflection analysis and applications. In Information and Media Technologies, volume 8, pages 389-406, 2013.
    • (2013) Information and Media Technologies , vol.8 , pp. 389-406
    • Nitschke, A.N.C.1    Takemura, H.2
  • 7
    • 41549153477 scopus 로고    scopus 로고
    • Usability engineering for augmented reality: Employing user-based studies to inform design
    • May/June
    • J. L. Gabbard and J. E. Swan. Usability engineering for augmented reality: Employing user-based studies to inform design. IEEE Transactions Visualization and Computer Graphics, 14(3):513-525, May/June 2008.
    • (2008) IEEE Transactions Visualization and Computer Graphics , vol.14 , Issue.3 , pp. 513-525
    • Gabbard, J.L.1    Swan, J.E.2
  • 10
    • 79960212786 scopus 로고    scopus 로고
    • An automated calibration method for non-see-through head mounted displays
    • S. J. Gilson, A. W. Fitzgibbon, and A. Glennerster. An automated calibration method for non-see-through head mounted displays. Journal of Neuroscience Methods, 199(2):328-335, 2011.
    • (2011) Journal of Neuroscience Methods , vol.199 , Issue.2 , pp. 328-335
    • Gilson, S.J.1    Fitzgibbon, A.W.2    Glennerster, A.3
  • 14
    • 84900340682 scopus 로고    scopus 로고
    • Interaction-free calibration for optical see-through head-mounted displays based on 3d eye localization
    • march
    • Y. Itoh and G. Klinker. Interaction-free calibration for optical see-through head-mounted displays based on 3d eye localization. In Proceedings of the IEEE Symposium on 3D User Interfaces, pages 75-82, march 2014.
    • (2014) Proceedings of the IEEE Symposium on 3D User Interfaces , pp. 75-82
    • Itoh, Y.1    Klinker, G.2
  • 15
    • 84945128507 scopus 로고    scopus 로고
    • Performance and sensitivity analysis of indica: Interaction-free display calibration for optical see-through head-mounted displays
    • Sept.
    • Y. Itoh and G. Klinker. Performance and sensitivity analysis of indica: Interaction-free display calibration for optical see-through head-mounted displays. In Proceedings of the IEEE International Symposium on Mixed and Augmented Reality, pages 171-176, Sept. 2014.
    • (2014) Proceedings of the IEEE International Symposium on Mixed and Augmented Reality , pp. 171-176
    • Itoh, Y.1    Klinker, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.